MGV25.X USER GUIDE. Ver. 3.7 INSTALLATION OPERATION AND MAINTENANCE MANUAL OF THE GEARLESS MGV25.2 MGV25.3 MGV25.5

Similar documents
MGV25.X USER GUIDE. Ver. 3.1 INSTALLATION OPERATION AND MAINTENANCE MANUAL OF THE GEARLESS MGV25.X

MG300 USER GUIDE. Ver. 3.2 INSTALLATION OPERATION AND MAINTENANCE MANUAL OF THE GEARLESS MG300.4, MG300.6, MGV30.4 AND MGV30.6

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

Position Limit Switches PLTA

Montanari Giulio & C. s.r.l.

BOX A3 TEST REL. DATE R.T. Check and Approval

NPA-CP Pendant Control Station

NPA-CP. Pendant control station. OPtiONs. FeAtures. CertiFiCAtiONs

OPERATION & MAINTENANCE MANUAL SYNCHRONOUS GEARLESS MACHINES T32S/T32/T32L

BELT CONVEYOR CB/M5 Series

Electrically Released Brakes ERS VAR11-01 FT = 4100 N

BAH series Use and Maintenance Manual

BELT CONVEYOR PNL/4 Series User and maintenance manual

USER INSTRUCTIONS FOR SLIDING DOORS

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

Automatic concealed bollards 275 H600 and 275 H800 with pit

Explosion and flame-proof cast iron electric motors

HYDRONIC LIFT SOLUTION FOR A3 AMENDMENT

Crane fork KGM/KGA and KGQ/KGL

Electrically Released Brakes ERS VAR10 SZ 5000/5000

USER'S GUIDE and Spare Parts Drawings GENERIC APPLICATIONS

Charlie Pendant Control Station

Quick Start. Flat head screwdriver. Wheel carriage x 2. M8 Nut x 2. Strap Bolt x 2. 1 x 2m Anodised Track

Hollister-Whitney Elevator Corporation

Maximum Weight = 80 kg for 2 doors; Maximum door width = 1100mm (to suit up to maximum 2120mm clear opening) Quick Start. 5 & 4mm Allen keys.

Modular Flameproof Brakes

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

Explosion and flame-proof single phase electric motors

IP 900 W/KS & IP 900 D/KS

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

Solenoid Operator 0516 / 1216

BIG Pressure switch. Products. Functioning. The device change the electric contact condition on the working characteristic pressure be attainment.

CICLÓN ATTUATORE ELETTROMECCANICO IRREVERSIBILE A BRACCIO SNODATO PER CANCELLI A BATTENTE

Rotary Limit Switches Driver FRS Series

INSTRUCTION MANUAL_1219_ENGLISH SUPER ELF X3. Operating Instructions for DORNIER looms. Robustness Reliability Quality Productivity Versatility

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Solenoid Operator 0513 / 1213

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

Declaration of Conformity

Switching DC Power Supply

OPERATING INSTRUCTIONS. ASTRO HOIST Type E89-CTO

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax

Pump Series 999 DROPSA SpA In accordance with point 1.7.4, to I, Dir 98/37 CE

Digital Pressure Regulator Sentronic PLUS Series 614

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS

PF2C Rotary Limit Switch. PF2C Rotary Limit Switch

GREENSTAR CANTIELEVER. User Guide. v4 - English

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Swing Piston Compressors and Vacuum Pumps

USE AND INSTALLATION HANDBOOK

ISTRUCTION MANUAL Italian Movements Italian Movements

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Sheet n 1 of 20 Doc. n WDMM/02/E MOD. WDMM INSTALLATION, USE AND SERVICE MANUAL. PETROL INSTRUMENTS S.r.l APRILIA (LT) - ITALY

Installation manual. English. mystrike OPENER FOR RACK-DRIVEN SLIDING MOTOR

Certificate of Incorporation (Typical)

INSTRUCTIONS FOR INSTALLATION

Operating instructions According to Directive 2014/34/EU (ATEX) Annex II p group II, equipment category 1/2D

Type 6213 EV, 6281 EV

Ex m Solenoid Operator Type 0519

MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR

Rotary Limit Switches Driver FRM Series

WEL. Manuale di installazione e manutenzione per automazioni per porte battenti. Installation and maintenance. for swing doors.

SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC)

Disclaimer: This brochure is for information only. The manufacturer reserves the right to modify specifications.

Mod: KLD6-12/35XLAS-N

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

New Machinery Directive

Ditec DOD Industrial sectional door automations

PV4 - PIV6. Submersible multistage centrifugal electro-pumps. Installation and maintenance. This manual is to be given to the end user

Automatic concealed bollards 275 H600 and 275 H800 Control station

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

POWER SUPPLY UNIT FOR 2 KW MAGNETRON TECHNICAL NOTE

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy

MV Series Motors Operation & Parts Manual

D4DL. Guard Lock Safety-door Switch. Model Number Structure

SIZING OF SOLAR GENERATOR

User Guide AMF Floor / Portrait Adaptor

ARACHNE 230V 24V- 12V

Ditec LUXO Swing gates automation (Original instruction)

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ,

VA-7450 Series. Electric Valve Actuators

VEM motors Thurm GmbH

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

Installation, operation and maintenance manual

USER INSTRUCTION FOR PROGRAMMING INVERTER FUJI FRENIC LIFT

Declaration of Conformity as per Directive 97/23/EC

Installation Instructions

Ditec PWR25H/35H Automation for hinged gates

BOX A3 TEST R. Bocconi. REL. DATE R.T. Check and Approval

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

Transcription:

MGV25.X USER GUIDE INSTALLATION OPERATION AND MAINTENANCE MANUAL OF THE GEARLESS MGV25.2 MGV25.3 MGV25.5 Ver. 3.7 MONTANARI GIULIO & C. S.r.l. 41100 MODENA (Italy) Via Bulgaria,39 Tel. +39 059 45.36.11 Fax +39 059 31.58.90 Cap.Soc. 520.000 i.v. Export MO 004935 R.E.A. di MO N. 210108 Reg.Imprese di MO Cod.fisc. e Part.IVA n. 01047170368 Identification CEE No. IT 01047170368 www.montanari-giulio.com - E-mail: info@montanari-giulio.com

Aim The aim of this manual is to provide instructions for the correct installation, use and maintenance of the GEARLESS type MGV25.2, MGV25.3 and MGV25.5 for use in passenger and freight lifts. Warning: This booklet does not contemplate the instructions for the shutting down of the entire system, but only the instructions relating to the GEARLESS, therefore before starting the installation of the gearless you must follow the instructions in this operation and maintenance manual and take precautions in accordance with the current safety standards. The Gearless motors MGV25 and all the components supplied by Montanari Giulio & C, have been tested in order to guarantee their correct operation. The Gearless motor has been tested in both empty and loaded operating conditions, in accordance with the technical specifications for velocity, car capacity load, car weight, presence or not of compensation and the type of roping requested when the order was placed. This ensures the correct operation and a minimum number of set-up operations. All responsibility is declined for any malfunctions due to installation with different characteristics, except in the case of specific approval by Montanari G. & C.

Summary: 1. References Standard 2 2. General notes 2 3. Transport 2 4. Warehouse storage 3 5. Installation 3 6. Use 11 7. Maintenance 11 8. Declaration of Conformity 13 9. Brake Certificate 14 1

MGV25 USER GUIDE MONTANARI GIULIO & C. S.r.l 1 References Standard. 1.1 The following standards are to be considered as references and are not necessarily entirely applicable to this technical instruction. (Table N 1) N Reference Type of standard Description 1 UNI 10147 E Maintenance : Terminology 2 UNI EN 81/1 E Safety rules for the construction and installation of passenger and freight lifts Table 1 2 General Notes. 2.1 The operations described in this manual must be carried out by qualified personnel, equipped with the necessary workshop tools. 2.2 Before all interventions the entire system must be put out of commission to prevent it from being used. 2.3 For all requests for spare parts or for particular instructions it is always necessary to specify the serial number, which can be found stamped next to the electrical connection terminal board. 3 Transport. 3.1 The entire gearless are packed in cases or crates. In some cases they are mounted upon wooden platforms, in order to be transported correctly on the lorry. The cases and crates are not load bearing and therefore cannot be stacked upon each other. 3.2 The unloading of the material, from the transport vehicle, must be done with equipment that is suitable for both the weight and the dimensions of the load. All the packing is designed for movement by fork lift and low lift platform trucks. 3.3 Upon the receipt of all material, check its condition. In the event of any damage do not proceed with the installation unless authorised otherwise by Montanari Giulio & C. 2

04/09/2013 Ver.3.7 4 Warehouse storage. 4.1 Preserve the gearless, even if it is still packed, in a dry place where it is protected from bad weather. 4.2 Once the packing has been removed take the necessary precautions to avoid the settling of any dust. 5 Installation. 5.1 Operating Conditions. - The gearless machine must be installed in a building or closed hoist-way. - Do not operate the gearless in an explosive atmosphere. - The ambient temperature must be within 0 C and +40 C. 5.2 Handling. The gearless MGV25 can be lifted using the holes already present on the base for the fitting of belts or chains. (Figure N 1) Lifting sample: Figure 1 Care must be taken to ensure that the gearless doesn t get knocked as the brake disc, the brake callipers and the electrical connection terminal board are particularly delicate. 3

MGV25 USER GUIDE MONTANARI GIULIO & C. S.r.l 5.3 Assembly. The gearless are ideal for assembly either with or without a machine room. The roping and therefore the load must always be orientated versus the base of the machine as shown in the diagram. (Figure N 2) MGV25.2 MGV25.3 MGV25.5 Figure 2 In the case of assembly with the machine down, and therefore with the roping and load upward, you must mount it rotated by 180 degrees. (Figure N 3) MGV25.2 MGV25.3 MGV25.5 Figure 3 4

04/09/2013 Ver.3.7 5.4 Gearless Dimension. Figure 4 MGV25.2 Figure 5 MGV25.3 Figure 6 MGV25.5 5

MGV25 USER GUIDE MONTANARI GIULIO & C. S.r.l 5.5 Brake. The gearless is provided with a disc brake that is operated by 2 independent electromechanical devices which are conform to the EN81-1 standard. The gripping callipers are pre-calibrated by the manufacturer and therefore don t require any further adjustment. Attention must be paid and if necessary precautions taken to ensure that oil or grease do not come into contact with the brake disc. Grease or oil on the brake disc can jeopardise the braking and put people in serious danger. 5.6 Lubrication. The gearless does not contain oil and is supplied with bearings that are lubricated for the life of the equipment; therefore no further lubrication is necessary. 5.7 Electric installation. The Gearless MGV25 has supplied with power cable (Figure N 7): - 3 Power Cable for U-V-W phases [1-2-3]. - 2 Power Cable for cooling fans supply (230 Vac) [F7-F8]. - 2 Cable for PTC Thermistor [T5-T6]. - 1 Ground Cable (Yellow-Green Cable). - 1 Shield Cable (Grey Cable). Figure 7 Gearless Cable 6

04/09/2013 Ver.3.7 With this configuration, the brake power supply and micro switches cables must be connected separately. Temporiti s Brake Device: (For MGV25.2 and MGV25.3 machines) This Brake has power cable within two cables; that cables can be connected directly at control panel. Figure 8 Brake of Temporiti In resting state (Electromagnet not supplied), the brake disks are locked from the surfaces movable (Green arrows in Figure N 9). In that condition the system is motionless. When motor received a moving command, the electromagnet of the brake is supplied releasing the brake disk (Green arrows in Figure N 10). Now the motor is free to moving. In the brake device there are two microswitch with two contacts; one normally open and one normally closed (Figure N 11). These contacts tell us the actual state of the brake device (See Truth table N 2). Figure 9 Brake Disk Locked Figure 10 Brake Disk Free 7

MGV25 USER GUIDE MONTANARI GIULIO & C. S.r.l Figure 11 Microswitch Brake Disk Locked Contact State Brake Disk Free Contact State Com N.O. Disconnected Com N.O. Connected Com N.C. Connected Com N.C. Disconnected Intorq s Brake Device: (For MGV25.5 machines): Table 2 Microswitch Contacts This brake device must be connected to the Booster, an electronic device that provide an overvoltage of 207 Vdc for one second and an hold voltage of 104 Vdc (Figure N 12). For major information see Booster Basic User Guide. Overvoltage 207 Vdc Power of single coil 270 W. Hold Voltage 104 Vdc Power of single coil 68 W. 8 Figure 12 Booster Half Bridge Basic

04/09/2013 Ver.3.7 In the brake device there are two couples of cables (one pair for coil); these cable must be connected in parallel and then connected at Booster device (Figure N 12 and Figure N 13). For major information see Booster Basic User Guide. Figure 13 Brake of Intorq In resting state (Electromagnet not supplied), the brake disks are locked from the surfaces movable (Green arrows in Figure N 14). In that condition the system is motionless. When motor received a moving command, the electromagnet of the brake is supplied releasing the brake disk (Azure arrows in Figure N 15). Now the motor is free to moving. In the brake device there are two microswitch with two contacts; one normally open and one normally closed. These contacts tell us the actual state of the brake device (See Truth table N 2). Figure 14 Brake Disk Locked Figure 15 Brake Disk Free 9

MGV25 USER GUIDE MONTANARI GIULIO & C. S.r.l GEARLESS MGV25 TECHNICAL CHARACTERISTICS Motor Type Pn [kw] Speed [Rpm] Vn [V] Cn [Nm] In [A] Cmax [Nm] Imax [A] Emf [V*s/rad] Poles [n ] F [Hz] R [Ohm] L [H] St. Load [Kg] I [kgm^2] Duty Cycle Weight [Kg] Typical Installation MGV25.20160 2.2 80 360 265 9 390 14.5 11 16 10.7 6.3 0.095 3400 0.2 40% 180s/h 120 408Kg 2:1 0.63m/s 320mm MGV25.22660 2.6 115 210 215 12 270 16 9 16 15.3 2 0.031 3400 0.2 40% 180s/h 120 408Kg 2:1 2m/s 320mm MGV25.20660 3.3 120 360 265 11 390 18 15 16 16 4.4 0.046 3400 0.2 40% 180s/h 120 408Kg 2:1 1m/s 320mm MGV25.20760 4.9 180 360 265 15 390 25 11.5 16 24 2.5 0.022 3400 0.2 40% 180s/h 120 408Kg 2:1 1.5m/s 320mm MGV25.30160 2.9 80 360 350 11 470 16 21 16 10.7 4.4 0.052 3400 0.25 40% 180s/h 180 544Kg 2:1 0.63m/s 320mm MGV25.30660 4.4 120 360 350 12 470 17 17 16 16 3.5 0.034 3400 0.25 40% 180s/h 180 544Kg 2:1 1m/s 320mm MGV25.30662 4.7 120 360 375 15 580 24 14 16 16 2.8 0.033 3400 0.25 40% 180s/h 180 680Kg 2:1 1m/s 320mm MGV25.30760 6.6 180 360 350 15 470 25 15 16 24 1.96 0.025 3400 0.25 40% 180s/h 180 544kg 2:1 1.5m/s 320mm MGV25.30762 7 180 360 375 20 580 34 13 16 24 1.49 0.022 3400 0.25 40% 180s/h 180 680Kg 2:1 1.5m/s 320mm MGV25.30360 10.4 255 360 390 29 580 48 7 16 34 0.75 0.013 3400 0.25 40% 180s/h 180 680Kg 2:1 2m/s 320mm MGV25.50950 3.7 60 360 590 13.5 850 20 23 16 8 3.8 0.045 3400 0.31 40% 180s/h 240 1000Kg 2:1 0.5m/s 320mm MGV25.50150 5 80 360 590 14.5 850 22.5 22 16 10.7 2.9 0.04 3400 0.31 40% 180s/h 240 1000Kg 2:1 0.63m/s 320mm MGV25.50650 6 120 360 590 20 850 30 18 16 16 1.8 0.018 3400 0.31 40% 180s/h 240 1000Kg 2:1 1m/s 320mm MGV25.50750 11.1 180 360 590 27 850 41 17 16 24 0.98 0.015 3400 0.31 40% 180s/h 240 1000Kg 2:1 1.5m/s 320mm MGV25.51050 13 210 360 590 37 850 58 9.5 16 28 0.48 0.009 3400 0.31 40% 180s/h 240 1000Kg 2:1 1.6m/s 320mm MGV25.50350 15.7 255 360 590 38 850 59 8 16 34 0.48 0.009 3400 0.31 40% 180s/h 240 1000Kg 2:1 2m/s 320mm Table 3 10

04/09/2013 Ver.3.7 6 Use. 6.1 General notes. The gearless are designed and constructed as lifting devices for lifts and hoists and respect the various sector standards. Any other use is to be considered improper. They cannot be used in systems with characteristics that are different to those agreed upon in the order (e.g. carrying capacity, velocity, etc.), Qualified and competent personnel must carry out all tests, inspections or manoeuvres that may be necessary in accordance with the current standards. 6.2 Emergency manoeuvre. The emergency manoeuvre must be made by an independent electrical device, which is capable of opening the brake and moving the gearless at a reduced velocity. It is possible to exploit the characteristics of the synchronous motor as it can slow down the car when the phases are put into short circuit. This system has some load limits and it is therefore necessary to observe several precautions. Montanari Giulio & C. can provide the information necessary to apply the aforementioned solution upon request. 7 Maintenance. 7.1 Traction/Driving pulley. Periodically, at least once a year, check the amount of wear on the cable races on the traction pulley. In the event of the cables slipping or of excessive wear contact Montanari Giulio & C. for the substitution instructions, always indicating the serial number. 7.2 Component substitution. The instructions for any eventual component substitutions must be asked for each time from the Technical Department, specifying the serial number. 11

MGV25 USER GUIDE MONTANARI GIULIO & C. S.r.l 8 Declaration of Conformity. DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY (Directive 2006/42/CE, Annex II, par. B.) Manufacturer: Montanari Giulio & C. S.r.l. Via Bulgaria n.39, 41122 Modena Person authorized to compile the relevant technical documentation: Bertoni Stefano, Montanari Giulio & C. S.r.l., Via Bulgaria n.39, 41122 Modena Model of the partly completed machinery: Gearless: MG200 MGV25 MG25S MG300 MG34S MCG150 MDD35 - MDD70 The essential requirements of this Directive are applied a fulfilled and the relevant technical documentation is compiled in accordance with part B of Annex II. The partly completed machinery comply with the following directives: 95/16/CE, 89/336/CE, 92/31/CE, 73/23/CE The Montanari Giulio & C. S.r.l. undertakes to provide, in response to a reasoned request by national authorities, relevant information on the partly completed machinery. The partly completed machinery must not be put into service until the final machinery into which it is to be incorporated has been declared in conformity with the provisions of this Directive: 2006/42/CE or 95/16/CE. Violation of the dispositions given in these technical instructions will immediately invalidate any form of guarantee Note: With regard to fulfilment of point 9.7 of reference regulation EN81-1 1998, please remember that Montanari supplies protection devices only if specifically requested by the customer. The responsible Ponanti Graziano Firma: Modena il 22/12/2009 12

04/09/2013 Ver.3.7 9 Brake Certificate. The brake has been designed in conformance with the specific requests of the EN81-1 standard. This device is therefore usable as a brake to slow down the car in combination with a suitable speed governor in the case of excessive velocity in the rising direction. The examination certificates issued by TÜV B.B. 13

MGV25 USER GUIDE MONTANARI GIULIO & C. S.r.l Temporiti s Certificates: 14

04/09/2013 Ver.3.7 15

MGV25 USER GUIDE MONTANARI GIULIO & C. S.r.l Intorq s Certificates: 16

04/09/2013 Ver.3.7 17

MONTANARI GIULIO & C. S.r.l. 41100 MODENA (Italy) Via Bulgaria,39 Tel. +39 059 45.36.11 Fax +39 059 31.58.90 Cap.Soc. 520.000 i.v. Export MO 004935 R.E.A. di MO N. 210108 Reg.Imprese di MO Cod.fisc. e Part.IVA n. 01047170368 Identification CEE No. IT 01047170368 www.montanari-giulio.com - E-mail: info@montanari-giulio.com Manuale_MGV25_ENG_Vs3_7