MODEL 2001 HERMETI-CHECK OPERATING INSTRUCTIONS

Similar documents
User s Manual. Automatic Switch-Mode Battery Charger

1) READ THE M500 INSTRUCTIONS CAREFULLY TO GET A FULL UNDERSTANDING OF THE M500 AND HOW IT OPERATES.

Service and Parts Manual. NO LONGER IN PRODUCTION Some service parts may not be available for this product. Otolaryngology Chair.

GFM-40ac COMPLIANCE WESTUSA. Ground Circuit Tester. Instruction Manual

Coil Inserter Module

ACL 780/781 Economy Combo Tester

NIGHT-LITE PRO II. Electrical System Troubleshooting Guide and Procedures

60 Series Engine Controls

Electronic Refrigerator Diagnostics

HIGH PRESSURE AIR COMPRESSOR SYSTEM MODEL #: 091-9HP-220 INPUT:

Advanced EasyStart Troubleshooting

SECTION 4 ELECTRIC MOTORS UNIT 20 TROUBLESHOOTING ELECTRIC MOTORS UNIT OBJECTIVES 3/21/2012

SECTION 4 ELECTRIC MOTORS UNIT 20 TROUBLESHOOTING ELECTRIC MOTORS

Model 6275RC 50% Duty Cycle Compressor

DC TO AC POWER INVERTER PWRIC150012W INSTRUCTION MANUAL

Product Catalog EYLANDER ELECTRIC INC.

AC Anywhere. User Manual. Power Inverter. (Class II product) Please read the installation and operations instructions before using the Power Inverters

DC TO AC POWER INVERTER PWRINV150W INSTRUCTION MANUAL

Product Data Sheet : LIGHTHAWK 6 CELL

OPERATING INSTRUCTIONS BULLETIN MODEL DA750 March MAGNETIC INSPECTION UNIT

GF-30AC. Ground Circuit Tester COMPLIANCE WESTUSA. Instruction Manual

4 in 1 POWER STATION Model: 7226

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

OWNER'S MANUAL POWER BOOSTER. Rechargeable 12 Volt DC power supply. Item # Enclose copy of original sales receipt

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

Which one? All are capable of doing the job

ATD-5921 RECHARGEABLE 12 VOLT 18 AMP/HOUR JUMP START OWNERS MANUAL

INSTALLATION & OPERATION MANUAL

ATD-5925 RECHARGEABLE 12 VOLT 18 AMP/HOUR JUMP START WITH BUILT-IN 260 PSI AIR COMPRESSOR OWNERS MANUAL

E.S.P. Embedded Sensing Probes for Motor Brushes

Electricity. Teacher/Parent Notes.

LG Air conditioning CAC and Multi Split unit Fault code sheet Universal and Multi Split Units

TESCO THE EASTERN SPECIALTY COMPANY Date: 05/04/15 Canal Street and Jefferson Avenue Bristol, PA 19007

J.E. ADAMS INDUSTRIES OWNERS MANUAL VACUUMS AIR/VACUUMS AIR/WATER/VACUUMS

"ELECTRICAL SAFETY IN THE LABORATORY"

ATD-5928 RECHARGEABLE 12 VOLT 22 AMP/HOUR JUMP START OWNERS MANUAL

348002K/348012K Manifold Block Style Service Manual 12/2000

CI 3000 Coil Inserter

Battery Control Center - Diesel

Technical Information and Diagnostic Guide

RigMaster Power Service and Repair Manual Document # S901009

Micro-Air Corporation Route 526 Allentown, NJ 08501

COOKSON OWNER'S MANUAL

SUPERIOR PERFORMANCE

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

LABORATORY SAFETY SERIES: Electrical Safety

INSTALLATION CLAMP-ON FORK MOUNTED DRIVING LIGHTS 5015

Northwest RV Supply Manual Compliments of Printed From TROUBLESHOOTING

Model: PI-140 Power Inverter Converts 12V DC battery power to 120V AC household power

INSTALLATION INSTRUCTIONS

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

STARTING SYSTEM TEST STARTING SYSTEM

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC260N & BC335 OPERATING & MAINTENANCE INSTRUCTIONS

DC TO AC PURE SINE POWER INVERTER PWRI18012S INSTRUCTION MANUAL

INSTALLATION CONSTELLATION DRIVING LIGHTS 5009

Battery Tester. GxT Incorporated, Cheboygan MI, U.S.A. All Rights Reserved E040-01G. 40 & 42HD Operator s Manual

HT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option

PRODUCT OPERATING MANUAL

A/C COMPRESSOR CLUTCH

The engine is running. DTC P0351, P0352, P0353, and P0354 run continuously once the above condition has been met.

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

OWNER S MANUAL PORTABLE POWER COMPACT & ROBUST

INSTALLATION FORK MOUNTED DRIVING LIGHTS 5008

MASTER SALT SAND SPREADER WIRELESS CONTROL MANUAL

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

FAULT CODE 451 Injector Metering Rail Number 1 Pressure Sensor Circuit - Voltage Above Normal or Shorted to High Source

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS. Frames 143T - 449T

STARTING SYSTEMS 8B - 1 STARTING SYSTEMS CONTENTS

Model Volt-Amp-Wattmeter INSTRUCTION MANUAL

6300 Series Owner/Operator Manual

JUMPSTART MODEL NO: JS900/JS910 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & GC10/16

COLDWATER LAKE FACILITIES DUPLEX PUMP STATION

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

FlexCharger Battery Chargers

OWNER S MANUAL POWER INVERTER

O W N E R ' S M A N U A L

JUMPSTART MODEL NO: JS1000, JS1010 & JS1224 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: , & GC0514

How to bias: MTS3200, MTS3212 Rev A 8/1/2008 carvinservice.com

EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners

INSTALLATION CONSTELLATION DRIVING LIGHTS 5009

DEALER SERVICE BULLETIN

Service Bulletin Trucks

GRD502-B Flow Chart 02/05/09

OBAE, OBAEXU, ON BOARD Battery Chargers

LEAD ACID BATTERY CHARGER

Operating Manual Includes Pumps: PG-9000 Part #R809606

Operating Instructions

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.

HEAVY DUTY ONBOARD AIR SYSTEM

Installation Bulletin Number: IB-5111 Rev: A Date: Feb 2014 Affected Parts: K

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

Biasing the Vintage Series (Nomad, BelAir, VT50, Vintage 33)

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

Shock Tube Saver System Installation and Operation Manual Duke Part No Rev. B

MEDIUM DUTY ONBOARD AIR SYSTEM

Transcription:

MODEL 2001 HERMETI-CHECK OPERATING INSTRUCTIONS Model 2001 HERMETI-CHECK tests all single phase compressors up to 5 HP, 110, 220, or 277 volts. The HERMETI-CHECK comes equipped with a built in 200 micro farad start capacitor. Read these instructions carefully before using the instrument. The HERMETI-CHECK is a precision electrical test instrument. If treated with reasonable care, it should provide a long life of satisfactory service. Keep the instrument free of dirt, grease and moisture and protect it from excessive shock or vibration. This instrument is intended for use only by qualified air conditioning and refrigeration service technicians. Exercise extreme caution while using this unit. Make sure the system being tested is disconnected from power when making connections to the HERMETI- CHECK. STANDARD ACCESSORIES Compressor Test Clips: RED, WHITE, BLACK, and GREEN leads wired directly to the instrument which terminates in alligator clips. Used to start and compressors and test windings. #2136 220 Volt Adapter Leads: Standard female receptacle terminating in alligator clips. Adapts the instrument plug to 220 volt power source. #2186 Capacitor Test Leads: White leads with alligator clips terminating into banana plug. Used to test capacitors. SETUP Before connecting the HERMETI-CHECK to power, make connections to the compressor as follows: 1. Disconnect all system wiring from compressor terminals. 2. Connect RED test clip to RUN terminal. 3. Connect WHITE test clip to START terminal. 4. Connect BLACK test clip to COMMON terminal.

5. Connect GREEN test clip to COMPRESSOR CASE. 6. Set COMPRESSOR TYPE switch to proper setting for compressor being tested. 7. Set POWER switch to OFF. 8. Connect HERMETI-CHECK to power supply of correct voltage for the compressor. For 220 V compressors use the 220V Adapter leads. NOTE: The green lead of the 220 V Adapter Leads must be connected to proper ground. DO NOT CONNECT TO COMPRESSOR CASE. 1. Set POWER switch to TEST. TESTING WINDINGS 2. OPEN TEST: Set OPEN TEST switch to RUN WINDING. If red lamp glows, circuit is complete and winding is not open. Repeat with switch set to START WINDING. 3. GROUND TEST: DO NOT TOUCH COMPRESSOR DURING GROUND TEST. Push GROUND TEST switch to the right. If red lamp glows, windings are grounded to the compressor case and the unit must be replaced. If red lamp does not glow the compressor is not grounded and further tests may be performed. STARTING THE COMPRESSOR If windings test OK and are not grounded, compressor may be started with the HERMETI-CHECK. Make sure the instrument is connected to the correct voltage for the compressor. 1. Set COMPRESSOR TYPE switch to proper setting. 2. Push START switch to right and hold. 3. Set POWER switch to RUN.

4. Release START switch when compressor starts. DO NOT REVERSE THIS PROCEDURE. Compressor should start unless it is tied up. 5. Run winding (line) volts, start winding volts and running amperes can be measured while the compressor is operating by setting the slide switch to the proper position. (RUN VOLTS, START VOLTS, AMPS). 6. Normal ranges are 0-600VAC and 0-50 A. If low ranges (150 VAC 10 A) are desired, push LOW RANGES switch. IF COMPRESSOR STARTS If the compressor will start and run with the HERMETIC-CHECK and did not run with the regular system connections, the fault lies with the capacitor, relay, overload or other system controls or wiring. Start capacitors and relays can be checked by substitution. Checking Start Capacitor Substitute the HERMETIC-CHECK start capacitor for the system capacitor. 1. Reconnect all original system wiring to the compressor. 2. Set POWER switch to OFF position. The instrument does not need to be plugged in. 3. Discharge system capacitor and disconnect from system wiring. 4. "Plug one of the WHITE capacitor test leads into the BLACK banana jack labeled INTERNAL START CAPACITOR. 5. Attach the WHITE capacitor test lead to one of the system terminals where the system start capacitor was connected (not to the capacitor itself). 6. Attach the RED test clip (used for run terminal during starting) to the other system terminal where the start capacitor was connected. 7. Set COMPRESSOR TYPE switch to CAP START. 8. Turn on the compressor to see if it will start with the HERMETI-CHECK start capacitor.

Checking System Relay: If the compressor still does not start, replace the system relay with the HERMETI-CHECK START switch. 1. Reconnect all original system wiring to the compressor. 2. Set POWER switch to OFF. The instrument does not need to be plugged in for this procedure. 3. Reconnect system start capacitor. 4. Connect RED test clip to power terminal of the relay (L terminal of current relay; 1 terminal of potential relay). 5. Disconnect wire from start winding relay terminal (S terminal of current relay; 2 terminal of potential relay) and attach WHITE test clip to wire. 6. Set COMPRESSOR TYPE switch to SPLIT PHASE. 7. Apply power to the system and push START switch to the right to start system. IF COMPRESSOR IS TIED UP The following techniques may be used to try to free a stuck compressor. The methods are presented in order of increasing danger to both compressor and operator. Use caution and consider safety first as you perform them. Poke Start: Split phase compressors that start hard may be helped by setting the COMPRESSOR TYPE switch to CAP START. The added poke of the starting capacitor may free up the compressor. A hard start kit should be installed for future starting. Reverse Start: Interchanging run and start windings for starting is often thought to free some stuck compressors. Theory says it's hopeless, but you can try by turning REVERSING SWITCH from REGULAR to REVERSE, then attempting to start the compressor. Follow instructions under "STARTING THE COMPRESSOR". Return switch to REGULAR position after test. Jump Start: 110V compressors may free themselves if they are given a jolt 220 V. Follow starting instructions under "STARTING THE COMPRESSOR" but connect the HERMETI-CHECK to 220 V. If compressor starts, do not run on 220 V for more than a few seconds.

OTHER TESTING FUNCTIONS Checking Run Capacitor: Once the system starts properly, the run capacitor can be tested. 1. Disconnect system wiring from run capacitor. 2. Connect Model 2001 to compressor as described in "SET UP". 3. Start compressor (see "STARTING THE COMPRESSOR") and record the run winding amperage without run capacitor. 4. Turn compressor off and disconnect the HERMETI-CHECK from power source. 5. Plug WHITE capacitor test lead into WHITE and RED JACKS labeled "EXTERNAL RUN CAPACITOR". 6. Connect WHITE test lead clips to run capacitor terminals. 7. Reconnect HERMETI-CHECK to power source. 8. Start compressor and record the run winding amperage with run capacitor. If amperage draw decreases with run capacitor connected, run capacitor is OK. REPAIR RETURN INFORMATION Please include a detailed description of the malfunction and proof of purchase. Estimates may be requested in advance. All repairs must be carefully packaged and returned to place of purchase or shipped prepaid to the factory.

REPLACEMENT PARTS 2109 Switch CAP START-SPLIT PHASE 2110 Switch: GROUND TEST 2112 Switch: POWER (RUN TEST) 2113 Switch: OPEN TEST 2114 Switch: START 2115 Switch: REVERSING 2116 Start capacitor 2136 220V Adapter Leads 2186 capacitor leads