SPSR-115/230. Self-Powered Sensor

Similar documents
SPSR-115/230. Self-Powered Sensor

MONARCH INSTRUMENT. Instruction Manual. Portable Deluxe Stroboscopes

MONARCH INSTRUMENT. Instruction Manual. Portable Stroboscopes

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

The Efficient Solution for Pipetting up to 100 ml at once! USER'S GUIDE

Digital Engine Tachometer

POCKET-TACH 100 MONARCH INSTRUMENT Rev 1.4. Instruction Manual. Printed in the U.S.A. Monarch Instrument 2001 all rights reserved

Weatherproof Tubular Slip Ring Assembly

Photoelectric Sensors 55 Series

Installation manual FS Cradle

4 - SETTING UP THE MACROMAN CHARGING POSITION 4 Wall mounted 4 Workbench set-up 4

SSP-Series Portable Balances Operation Manual

Differential Pressure Sensors

Switching DC Power Supply

Flex current clamps A 1179 A 1257 A 1395 User Manual Version 1.6; Code No

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

Installation and user manual. 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i ENGLISH. Copyright 2013 EATON All rights reserved.

i3000s/i2000 Flex AC Current Probe

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

MODEL: PSN3. Final Control Elements. STROKE 6: 0 to 60 mm (0 to 2.36 )

SITESTAR ELECTRONICS CABINET DESCRIPTION

MANUAL. Single charger

Testing Instrumentation Gasboard 5020 for exhaust gases from petrol or LPG engines

WPS500X 500 psi /34.5 bar Automotive Pressure Transducer. User s Guide

QSI (Q-Star) Electronics Owner s Manual

Battery Charger JCB- SCH20LI.2

Perfusion Valve Controller

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

Megohmmeter Test Probe

746 Wrist Strap Tester Installation, Operation and Maintenance

Versatile and Rugged Industrial LIthium/LiPO Charger Series

Video & Power Over Coax Kit

EDI K_Instructions.qxd 28/07/ :34 Page 1 ORDER CODE: EDI K MODEL IRT537. Infrared Thermometer OPERATING MANUAL CLASS 2 LASER

Ulyser Component Maintenance Manual

WPS bar, 60 MPa, 8700 psi Hydraulic Pressure Transducer. User s Guide

HST-BL-2830MS & HST-BL-2830MS-USA

Intrinsically Safe Flashlight - Rechargeable LED Flashlight with Spot and Flood Beams

RoHS-Compliant. Watertight, Dust-Resistant Motors FPW Series

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

Model 1693, 1694 Switching DC Power Supply

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

PHOTOMULTIPLIER POWER SUPPLY MODEL 70706

Research Isometric Transducer

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

HARDWIRE SC-2 VALVE DISTORTION OWNER S MANUAL

Model Pressure range ON/OFF output Linear output

Crime-lite 2. a new and improved range of forensic light sources

Model Pressure range ON/OFF output Linear output

KSZ 10B Current Probe Calibrator. Instruction Manual

QSB (Q-Star) Electronics for QSE Electromagnetic Meter. Owner s Manual TABLE OF CONTENTS

NY 55 Mall Drive, Commack, NY LA Earl St, Torrance CA 90503

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

User Manual EN. Front Bolt

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

1000FLT. Users Manual. Fluorescent Light Tester

c-go 24V/6A 24V/8A 24V/12A

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Model DFX Doppler ultrasonic flow meter

Battery Operated Ultraviolet Paint Curing LED Light Cart Dolly - 395NM - Four Adjustable Locking

G1160A Agilent 1100 Series Multiple Purpose Switching Valve

Data Sheet P1A Pressure Sensor

Vehicle Design, Construction, and Operation

SPECIFICATION SHEET ORION ROAD LANTERN. IP66 RATED CRI. 230v /50hz

Ti300 PRO, Ti400 PRO, Ti450 PRO, Ti450 SF6, Ti480 PRO Thermal Imagers

Battery Charger JCB-FCH20LI2

WOOOM INSTRUCTION MANUAL

ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

KSZ 100B Current Probe Calibrator. Instruction Manual

720 W / 24 V On-board Battery Charger. for industrial applications. Product Data Sheet

This Regulation is established on the basis of subsections 26 (3) and (8) of the Waste Act.

LED HANDHELD SLIT LAMP

IR LED Light Bar - 16 LEDs - 48 Watts - 750/850/940 NM - Extreme Environment VDC

3-Year Limited Warranty. See the Users Manual for the full warranty.

KD1E Range Potential Indicators

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Ti200, Ti300, Ti400, Ti450, Ti480 Thermal Imagers

How to Order BS B. Nil. Bracket (End bracket, Center bracket) Nil

User Manual EN. White LED Headlight & Red Tail Bolt COMBO

EASY CHARGE Waterproof portable Battery Charger

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

Nickel Metal Hydride Battery Pack. User Handbook

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

Infrared LED Light Emitter w/ Magnetic Gooseneck Mount or 940NM - 700'L X 80'W Beam VDC

DRB-1 Series Instruction Manual

METEOROLOGICAL INSTRUMENTS

Intelligent NiMH/NiCd/Li-ion Charger TN456

REMOTE CONTROLLED DOG TRAINING COLLARS

IR LED emitter bar - 12 watts - 4 LED - 120'L x 60'W Beam VDC - Extreme Environment

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

ADN-W BA. Li-Ion Battery Pack. Instruction manual

9419 E US HWY 175, Kemp, TX Phone: Fax:

ELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

Transcription:

MONARCH INSTRUMENT Instruction Manual SPSR-115/230 SPSR-115/230 Self-Powered Sensor TTL Pulse Output 15 Columbia Drive Amherst, NH 03031 USA Phone: (603) 883-3390 Fax: (603) 886-3300 E-mail: support@monarchinstrument.com Website: www.monarchinstrument.com

Safeguards and Precautions 1. Read and follow all instructions in this manual carefully, and retain this manual for future reference. 2. Do not use this instrument in any manner inconsistent with these operating instructions or under any conditions that exceed the environmental specifications stated. 3. This instrument is not user serviceable. For technical assistance, contact the sales organization from which you purchased the product or Monarch Instrument directly. In order to comply with EU Directive 2012/19/EU on Waste Electrical and Electronic Equipment (WEEE): This product may contain material which could be hazardous to human health and the environment. DO NOT DISPOSE of this product as unsorted municipal waste. This product needs to be RECYCLED in accordance with local regulations, contact your local authorities for more information. This product may be returnable to your distributor for recycling - contact the distributor for details. NOTE: This product contains Nickel Metal Hydride (NiMH) batteries which must be recycled. Refer to the Battery Disposal section on page 4 for details. Monarch Instrument s Limited Warranty applies. See www. monarchinstrument.com for details. Warranty Registration and Extended Warranty coverage available online at www.monarchinstrument.com.

TABLE OF CONTENTS INTRODUCTION...1 FUNCTIONS AND OPERATION...1 SPSR Interface Module...1 Connections...2 Controls...2 LED Indication...3 Recharging the Batteries...3 SPSR-115/230 Series - SPSR-IM with ROS-P...3 ROS-P...3 Operating the SPSR as a triggering source...4 BATTERY DISPOSAL...4 COMPONENT SPECIFICATIONS...5 SPSR-IM Interface Module...5 ROS-P Remote Optical Sensor...6 SENSORS / OPTIONS AND ACCESSORIES...8

INTRODUCTION The SPSR-IM Self Powered Sensor Interface Module is a self-contained, rechargeable battery powered device for developing a TTL compatible one pulse per revolution output for triggering external equipment such as vibration analyzers, spectrum analyzers, stroboscopes, data acquisition equipment, tachometers, balancers, waveform analyzers and magnetic tape recorders. The SPSR-115/230 is comprised of the SPSR-IM Interface Module, which provides power to a sensor and couples the sensor to a BNC output; an input sensor with a visible red LED light source (ROS-P); and a battery recharger. SPSR-115/230 (SPSR-IM, ROS-P and Universal Recharger) Optional sensors such as an optical laser sensor (ROLS-P-not shown), infrared sensor (IRS-P), or an amplified magnetic sensor (MT- 190P) may also be combined with the IRS-P Infrared Sensor SPSR-IM Interface Module when appropriate. (See separate instructions for these configurations.) FUNCTIONS AND OPERATION SPSR Interface Module The SPSR Interface Module (SPSR-IM) provides power to the input sensor, receives and optionally inverts the return pulse signal, and provides a switch selectable positive going 0 to 5 Vdc or negative going 5 to 0 Vdc 1 MT-190P Magnetic Trigger Sensor

pulse train trigger output on a BNC connector. Connections and operation are common to all SPSR models. Fully charged internal NiMH batteries will typically provide greater than 40 hours of continuous operation. In addition, the SPSR system can be operated continuously on external power by use of the recharger/power supply or cable provided. Connections Connect the input sensor via the 1/8 [3.5 mm] phone plug to the mating connector on the SPSR-IM. This sensor may remain connected even when recharging the internal batteries of the SPSR-IM. Connect the output signal cable to the BNC connector on the opposite end of the SPSR-IM and to the external equipment to be triggered. If operating from the recharger/power supply, connect the recharger to the connector marked External DC on the SPSR-IM and connect the wall unit to the appropriate power source. When using the CA- DCSPSR cable, connect the cable to the connector marked External DC on the SPSR-IM and connect the cigarette lighter connector to the appropriate power source. Controls The Power switch on the SPSR-IM controls both the operation and the charging of the system. The unit will only charge from external power in the power OFF position. In the power ON position, the unit will operate directly from external power any time that it is being supplied. Otherwise, it functions on internal battery power. The Output Selection switch determines the polarity of the leading edge of the TTL compatible output signal. In the NON-INVERTING position, the output signal on the BNC connector will be a negative going 5 to 0 Vdc pulse derived directly from the conditioned sensor output. When the INVERTING position is switch selected, the BNC output signal will be a positive going 0 to 5 Vdc, TTL compatible. 2

3 LED Indication Unit operational = solid green Unit charging = blinking red Charging done = solid red NOTE: Short red blinks followed by long blink = Charge error, contact factory Recharging the Batteries To recharge the SPSR-IM Interface Module batteries: 1. Connect the recharger/power supply or external power cable to the External DC input connector. 2. Connect the recharger/power supply into a working ac outlet, or the external power cable to a regulated power source of 5 to 12 Vdc. 3. Be sure the Power switch is in the OFF (CHARGE) position. The red CHARGE LED will indicate that the batteries are being charged. Allow up to 4 hours to fully charge. SPSR-115/230 Series - SPSR-IM with ROS-P The SPSR-115/230 consists of the SPSR-IM Interface Module described above, an ROS-P Remote Optical Sensor with eight foot cable and mounting bracket, and a PSC-2U (115/230 Vac) external power connection. One foot of T-5 Reflective Tape is also supplied. ROS-P When connected to the SPSR-IM as described above, the ROS-P illuminates the target with a visible red light from a high intensity LED and detects the reflected pulses from the rotating reflective tape target with an internal photo-detector. The ROS-P Remote Optical Sensor is capable of detecting a reflected pulse from T-5 Reflective Tape targets at distances of up to 3 feet and angles up to 45 degrees from the target.

The sensor is supplied with a set of two M16 jam nuts and a 90 angle slotted aluminum mounting bracket. For most applications, a 1/2 square piece of T-5 Reflective Tape should be applied to a clean area on the rotating object. The sensor should be mounted and optically aligned to illuminate the reflective target once per revolution. It is recommended that the optical sensor be placed at a slight angle (approximately 10-15 degrees) from perpendicular, so that the sensor will detect only the reflected pulses from the target. The sensor should be at least 2 inches and no more than 3 feet from the target. The green LED On-Target Indicator on the ROS-P will blink at the input frequency or be continuously illuminated when properly aimed. Operating the SPSR as a triggering source Once the ROS-P input sensor is properly mounted and aligned, further connections and operation should proceed in accordance with the functions and descriptions under the SPSR Interface Module sections entitled Connections and Controls. The pulse signal on the connector marked Output provides a sharp leading edge for reliable and repeatable triggering of the connected device. This output is capable of driving a hundred feet of coax cable. Be sure to select the direction (0 to 5 Vdc or 5 to 0 Vdc) of this signal to provide the required polarity of the leading edge to properly trigger the connected equipment. BATTERY DISPOSAL Prior to disposing of the SPSR-IM, the user must remove the Nickel Metal Hydride batteries. To do this, remove the four (4) rubber feet on the bottom of the unit. This will expose four (4) screws that must be removed to dismantle the bottom case piece, exposing the batteries. Remove the batteries and place tape over the battery terminals to prevent them from shorting. The batteries 4

should be sent to a recycling center or returned to the factory. The rest of the parts may now be disposed of. NOTE: This product contains Nickel Metal Hydride (NiMH) batteries. Replace only with the same type of battery Rechargeable NiMH. COMPONENT SPECIFICATIONS SPSR-IM Interface Module Internal Batteries: Nickel Metal Hydride (NiMH) Battery Pack, 4.8 Vdc Operating Interval: >40 hours typical with ROS-P (~40mA load) Charge Time: up to 4 hours Output: TTL compatible pulse, INVERTED or NON-INVERTED switch selectable. With an ROS (negative pulse) input, the output will be a positive pulse when set to inverted or negative pulse when set to non-inverted. Optionally, the output can be open collector (external pull up is required). Bandwidth: 0 to 100 khz Battery Current Draw: 12mA with 10 kω load (operational) 9V Input Current Draw: 14mA with 10 kω load (operational) Power Supply: PSC-2U (operational/charge): Conforms to UL STD 60950-1 Certified to CSA STD C22.2 No. 60950-1-03 OR 9Vdc to 15Vdc with CA-DCSPSR Cable LED Indicator: Status indication, see LED Indication section Output Connector: BNC Connector (female) Operating Temp: 32 F to 122 F [0 C to 50 C] Weight: 8.3 oz. [235 grams] Dimensions: 5.0 x 2.5 x 1 [127 mm x 64 mm x 25 mm] 5

Remote Sensor Input Jack Recharger Jack SPSR-IM Dimensions ROS-P Remote Optical Sensor Operating Envelope: Up to 3 feet [0.9 m] and 45 from reflective target Speed Range: 1 to 250,000 RPM Illumination Source: Visible red LED, 5 Vdc @ 30 ma Operating Temp: 14 F to 158 F [-10 C to 70 C] Output Signal: 5 to 0 Vdc TTL compatible pulse On-Target Indicator: Green LED on end cap Material: 303 Stainless steel Lens: Acrylic plastic Cable Length: 8 feet [2.5 m] Standard Dimensions: Threaded Tube - 2.90 L x 0.625 diameter [M16 x 1.5 x 74 mm] supplied with two M16 jam nuts and mounting bracket 6

M16 x 1.5 Green On Target LED 2.90 [74.0mm] 0.62 [15.9mm] ROS-P and mounting bracket Dimensions Compliance: Both the SPSR-IM and ROS-P units are CE compliant. Low Voltage Directive (LVD) 2014/35/EU Electromagnetic Compatibility Directive (EMC) 2014/30/EU Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU 7

SENSORS / OPTIONS AND ACCESSORIES ROS-P ROS-P-25 ROLS-P IRS-P MT-190P EC-25P Remote Optical Sensor with 8 foot [2.5 m] cable and mounting bracket Remote Optical Sensor with 25 foot [7.6 m] cable and mounting bracket Remote Optical Laser Sensor with 8 foot [2.5 m] cable and mounting bracket Infrared Sensor with 8 foot [2.5 m] cable for use without reflective target at 0.5 inch [12.7 mm] gap (5 to 500,000 RPM) Magnetic Trigger Sensor/Amplifier with 8 foot [2.5 m] cable - 0.250 [6.4 mm] operating gap from target, 2 (L) x 5/8 [50.8 x 15.9 mm] 25 foot [7.6 m] Extension Cable for remote sensors with male 1/8 [3.5 mm] phone plug to female 1/8 [3.5 mm] connector T-5 Reflective Tape, 5 foot [1.5 m] roll, ½ inch [13 mm] wide T-5WP Waterproof Reflective Tape (honeycomb pattern), 5 foot [1.5 m] roll, 1 inch [25 mm] wide BP-R PSC-2U Replacement NiMH Battery Pack (for SPSR-IM ONLY) Universal Recharger with plugs, 115/230 Vac - 50/60 Hz CA-DCSPSR 6 foot [1.8 m] DC Adapter Cable assembly with cigarette lighter plug to operate and charge SPSR-IM from 12 Vdc 8

Check out some of our other product lines Handheld Tachometers Speed Sensors Panel Tachometers Portable Stroboscopes Temperature/ Humidity Sensors Paperless Recorders Machine Vision Stroboscopes Vibration Meters Track-It Data Loggers Printed in the U.S.A. Copyright 2018, Monarch Instrument, all rights reserved 1071-4847-116 0618