Bulletin NEM Combination Non-Reversing Starters Product Selection Circuit Breaker Type NEM Size Continuous mpere Rating [] Bulletin NEM starter sizes Overload relays: Eutectic supplied as standard, solid-state available as an option Circuit breaker magnetic only (instantaneous) Painted metal enclosures: Type, Type R// Stainless steel enclosures: Type /X Hazardous location enclosures: Type & Modifications factory installed ccessories field installed Service entrance rated Bulletin combination non-reversing starter consists of a Bulletin starter and a circuit breaker magnetic only (instantaneous trip) mounted in a common enclosure. Starters sizes & consists of a thermal magnetic (inverse time) circuit breaker. Table of Contents Heater Elements Starters with eutectic alloy overhead relays require heater elements. Located on page -. Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous mpere Rating Type General Purpose Type R// Rainproof, Waterproof, Dusttight Modifications... - ccessories... - Specifications... - pproximate Dimensions... - Standards Compliance UL CS C., No. Certifications Circuit Breaker Versions culus Listed (File No. E, Guide No. NKJH, NKJH) Hazardous Locations culus Listed (File No. E, Guide No. NOTH, NOTH) merican Bureau of Shipping Type R// Rainproof, Waterproof, Dusttight (Door Safety Hardware) Type /X Watertight Corrosion- Resistant Stainless Steel Motor Voltages V V V V Cat. No. Cat. No. Cat. No. Cat. No. / / - - - -F - - -J - - -C - - / / - - - -F - - -J - - -C - - -/ -/ -/ -/ - - - -F - - -J - - -C - - - - - -F - - -J - - -C - - / / -B - - -BF - - -BJ - - -BC - - / / -B - - -BF - - -BJ - - -BC - - -/ -/ -/ -/ -B - - -BF - - -BJ - - -BC - - -B - - -BF - - -BJ - - -BC - - -/ -/ -/ -/ -B - - -BF - - -BJ - - -BC - - -B - - -BF - - -BJ - - -BC - - -C - - -CF - - -CJ - - -CC - - -C - - -CF - - -CJ - - -CC - - -C - - -CF - - -CJ - - -CC - - To order starters (size ) with current limiters, add the letter C at the end of the listed cat. no. Example: Cat. No. - - -C. To order Visa-Window Breakers for certain mining applications (Canada only), add the letter V to the cat. no. Example: Cat. No. -B - -V. When controlling high efficiency motors consult your local Rockwell utomation sales office or llen-bradley distributor for proper circuit breaker selection. Coil Voltage Code The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no. Example: Cat. No. -B - - becomes Cat. No. -BB- -. For other voltages, consult your local Rockwell utomation sales office or llen-bradley distributor. [V] Common Control Transformer Control (See page - Note) C, Hz H B C V Separate Control (without transformer) HD D BD CD Overload Relay Code Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from page - to complete the cat. no. Example: Cat. No. -BB- becomes Cat. No. -BB-F-. Publication -C-EN-P -
Bulletin Line Modifications Factory Installed NEM Combination Contactors/Starters For Use on Bulletins, L,, L,, X,, X,, H, M, V,, H, M, V,, E, F, G,, E, F, G,,,,,,,,,,,,,, X, V, X, and V, Continued Control Circuit Transformers Includes Primary Fuses and Secondary Fuse uxiliary Contacts Control Circuit Overload Relays (Eutectic lloy) Description of Modification With standard capacity, or Hz With standard capacity with fuse covers With standard capacity, or Hz With standard capacity, or Hz With W extra capacity, or Hz With W extra capacity with fuse covers With W extra capacity, or Hz With W extra capacity, or Hz With V capacity With V capacity with fuse covers With W extra capacity, or Hz With W extra capacity with fuse covers With W extra capacity, or Hz With W extra capacity with fuse covers With W extra capacity, or Hz With W extra capacity with fuse covers uxiliary contact installed on contactors uxiliary contact contactor (four maximum) late break uxiliary contact installed on disconnect uxiliary contact installed on circuit breaker (external to breaker) to operate with handle (two maximum) Control circuit fuse block less transformer Suffix No. P PC P P XP XPC XP XP XXP XXPC YP YPC XYP XYPC YYP YYPC, R/X/, /X, X, R/X/, /X Bolted NEM Size N N N N N N N N N N N N N N N N N N N, R//, /X, R N N, R//, /X, R, R//, /X, R Fuse Fuse Included Fuse with Protective Cover Fuse Included C Fuses Fuses Included Fuse with Protective Cover Fuse Included C Surge suppression for V or V C Coil Terminal blocks (Cat No. -HC) Terminal blocks (Cat No. -HC) N N N N N N N N N N N N N N N N N N N N N N N -Point Block TB -Point Block TB alarm contact adder (Bulletin ) N N alarm contact adder (Bulletin ) N N Omit overload relays For Bulletins, X,, X Deduct For Bulletins, Deduct -phase Powermonitor (Timemark Model ) Bulletin (used on Bulletin ), -pole maximum On Delay Off Delay N N N N B Bolted (R, & ) Unilock ( & ) ccessories Form compelling relay (used on Bulletin ), R//, /X N N Form B auto. seq. accelerating relay for each higher speed (used on Bulletin ), R//, /X N N Form C auto. seq. decelerating relay for each higher speed (used on Bulletin ), R//, /X N N = vailable N = Not vailable Bolted suitable for Type & or Type R, &. Unilock suitable for Type & or Type R, & with the addition of a drain or a breather and drain. White LED option not available, incandescent only. For Bulletins,, and devices. One auxiliary contact is installed on each of the two contactors. a N N N N Publication -C-EN-P -
Bulletin Line NEM Specifications NEM Non-Combination and Combination Contactors/Starters Short Circuit Rating Combination contactors and starters with disconnect switch: Bulletin,,, E, F, G, and X Combination Contactors and Starters with Disconnect Switch: Bulletin,,, E, F, G, and X vailable Short Circuit mperes RMS NEM Size Fuse Type Symmetrical [] H, K H, K J, R L L Combination Lighting Contactors with Disconnect Switch: Bulletin L vailable Short Circuit mperes RMS Lighting Contactor Rating [] Fuse Type Symmetrical [] H, K H, K J, R Combination Contactors and Starters with Circuit Breaker: Bulletin,,, E, F, G, and X vailable Short Circuit mperes RMS NEM Size Symmetrical [], R, R//, /X (stainless) Unilock R,, & Bolted R,, &, R, R//, /X (stainless) Unilock R,, & Unilock R,, & Bolted R,, & R, R// Combination Lighting Contactors with Circuit Breaker: Bulletin L vailable Short Circuit mperes RMS Lighting Contactor Rating [] Symmetrical [], R, R//, /X (stainless) Unilock R,, & Bolted R,, &, R, R//, /X (stainless) Unilock R,, & Unilock R,, & Bolted R,, & For the most up-to-date SCCRs, please see the on-line Industrial Controls catalog at www.ab.com/catalogs. - Publication -C-EN-P
Bulletin Line NEM Specifications NEM Non-Combination and Combination Contactors/Starters C Coil Data Operating Volt mperes Burden [V] Hz Coils NEM Size Inrush Sealed Heat Dissipation [W].. & P. ( poles). ( poles). ( poles) ( poles) ( poles). ( poles). (Series L).. (Interposing relay).. Economized DC Coil (Interposing relay).. Economized DC Coil (Interposing relay).. Economized DC Coil (Interposing relay). Coil Operating Limits % This rating is for the size contactor coil only. ll starters are shipped with an interposing relay as standard. Size starters are shipped with a V control circuit transformer and an interposing relay with a V Voltage is then rectified to DC for the contactor Size starters are shipped with a V control circuit transformer and an interposing relay with a V Voltage is then rectified to DC for the contactor Size starters are shipped with a V control circuit transformer and an interposing relay with a V Voltage is then rectified to DC for the contactor uxiliary Contacts (NEM and P) Bulletin, C Rating Designation Maximum Voltage or Hz Maximum C Contact Rating Per Pole [] Continuous Carrying Current [V] Make Break [] Make Break.. Maximum DC Contact Rating Per Pole for, uxiliary Contacts (Maximum Continuous Carrying Current is ) DC Rating Designation V DC V DC V DC P.. (Requires Contacts in Series). (Requires Contacts in Series) Publication -C-EN-P -
Bulletin Line pproximate Dimensions For NEM C Contactors/Starters pproximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Type /X (Enclosure Codes "C") Stainless Steel Industrial Use Enclosures for Bulletins, L,, L,, L,,,,,, M,, M, E, F, G, E, F, G, E, F, and G NEM Size Bulletin No...., L,, L,,...,, M, M, E, F, G, E, F, G,, L,, L,,,, E, F, G, L,, L,,,, E, F, G, E, F, G LP,, L,,,,, E, F, G, F, G, E, F, G, L,,, E, F, G, L,, E, F, G, L,,,, E, L Height. () () () () B Width. (). () (). () C Depth. (). (). () D. (). (). () E (). () F () (). () G Handle Depth H J Sizes,, and have one top mounting hole located on the center line. ll sizes in large enclosures have two top mounting holes located as shown. Fusible disconnect switch with Class J fuses. Type (Enclosure Codes "J") Stainless Steel Industrial Use Horizontal Enclosures for Bulletins H and H. (). () (). (). (). (). (). (). (). (). (). (). (). (). (). () (.) pprox. Shipping Weight [lb (kg)] (.) (.) (.) (.) -/ (.) - (.) / (.) / (.) / (.) -/ (.) -/ (.) -/ (.) -/ () -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) () -/ (.) / (.) dia. Mtg. Holes - Publication -C-EN-P