Trench Heating/Cooling. Katherm HK. Tested acc. to: BS EN 16430

Similar documents
AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

Highline 260i EC Waterside Fan Coil Unit

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

Total cooling capacity kw Total heating capacity kw Features

CLIMA CANAL HYBRID HEATING AND COOLING CLIMA CANAL. Compact floor recessed fancoil unit HEATING

BRIZA EC 12 HYBRID. World s slimmest fan coil HEATING AND COOLING

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

Residential comfort unit OperatiOn 2 models. new builds or existing properties. 5 operating modes COnfOrmity COmpOnents

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

42N. Room Fan Coils PRODUCT SELECTION DATA. MAINTENANCE INSTRUCTIONS Simpified installation & large options choice

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient.

Technical brochure. LTG Fans. Tangential fans Type GA 25 / TA 40. Impeller diameter 25 mm / 40 mm.

The Clima Canal is quiet even at high outputs, making it a discreet and effective heater for almost any situation

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

Water terminals from 91 to 1548 m 3 /h. from 0,5 to 9,6 kw. SysCoil Comfort. Floor and ceiling fan coil units. from 0,6 to 13,6 kw

Air Cooled Packaged Units

Carisma The Ultra Quiet Fan Coil

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

CENTRIFUGAL FAN COIL UNIT VCE

modular multi intelligent, environmental and versatile

Modular fan coil unit model PS

42GW. Hydronic Cassette Fan Coil Units PRODUCT SELECTION DATA INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EASY INSTALLATION

F Series. High-speed folding doors

BRIZA 22 HYBRID HEATING & COOLING

something new in the air Technical Bulletin

Cert. n 0545 Carisma CRC Fan Coil Unit The Ultra Quiet Fan Coil TECHNICAL GUIDE

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

PRODUCT SELECTION DATA. Performance. Flexibility. Intelligence. Energy optimisation. Acoustic optimisation. Drycoolers 09PE

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

Water terminals From 360 to 1598 m 3 /h. From 1.3 to 9.6 kw. SysQuare. Chilled water cassettes. From 1.1 to 14.0 kw

BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC

BRIZA Super slim and powerful heating, cooling

TVFC Dry and adiabatic cooling

NEW. Wall controls. YFCN Fan Coil Units. Technical Guide - for internal distribution only

product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - Air-cooled condensers 09PE

Total comfort control

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

Compact Sliding Door Operator Dor-O-Matic 2900 Series

product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE

Technical Catalogue. Cassette Fan Coils Climmy Comfort 3

Performance. Sound Levels. Impellers. Motors. Accessories

Plate mounted axial flow fans HXBR / HXTR Series

Features: Available in horizontal and vertical units

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

LTG High Performance Tangential Fans

Hydropac. Waterside Control Fan Coil Units For Horizontal and Vertical Applications. June Hydropac. Features

Swimming Pool CSR2 Heat Recovery Equipment

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

FLOOR CONVECTORS. accessories

Sales Release CDC ACB. Sales Information Only for Sales Partners of D+H Mechatronic AG CDC ACB. Availability

Ascotherm eco KC481 Heating and cooling in 4-conductor system

Slot diffusers for ceiling installation

BRIZA. Super slim and powerful heating, cooling

supplied in Form (B) configuration. Airflow over Impeller- Motor.

External venetian blinds with interlocking slats E 73/93/90 A6, C 73/93/90 A6, E 90 A5, C 90 A5 Description

Ceiling swirl diffusers

Ventilation grilles for installation into walls, sills or rectangular

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

Rosemex Products 96 VENTILATION INDUCTION UNIT

KLIMA Active Chilled Beams

High-speed folding doors. F Series

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com

EC Motor MultiZone Fan Coil Units. IXDL-Y Series l/s

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

CENTRIFLOW 3D WITH EC MOTOR >> Technical catalogue

CEILING CONCEALED SPLIT SYSTEM C SERIES


Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

Expert Design...Trusted Power

VIRTUO. Comfort ventilation boxes Self-supporting casing with lacquered

ZE Performance twin-screw extruders Boosting profitability in compounding

ROOF FAN ROOFMASTER STEC

CNVA TECHNICAL DOCUMENTATION. Active floor convector. Contents

Heat recovery ventilators with rotating exchanger, automatic control and EC motor, designed for vertical ducts and installation in technical room

ISF-AD. Inclined Floor Swirl Diffuser PRODUCT BROCHURE. Optional Features: Constant throw height adjustable airflow rate Electrical VAV operation

Electric transverse seat / tri-lateral stacker ( kg)

From domestic to commercial applications you ll find the detail you need to pinpoint which ActronAir system is most appropriate for your needs.

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Designed for Today s World

BASTONE (dual) fancoil Units

THERMOSCREENS AIR CURTAINS

CLOSE CONTROL UNITS WITH CHILLED WATER COIL

Industrial air coolers for cooling & freezing applications Cu/Al

Electric transverse seat / bi-lateral stacker ( kg) with telescopic forks

Accessories. Series REC

Mixed Flow Roof Fans (RMH)

Standard: for ceiling grid dimensions 1200 x 1200 mm, 1200 x 900 mm, 1200 x 600 mm. Other dimensions are available on demand.

Designed for Today s World

COMFORT AIR CURTAIN. SensAir

Tangential Fans Series TM and TMt Impeller Diameter 125 and 150 mm (4.92" and 5.9")

SILENT MV Ultra Quiet In-line Fans

SysCoil 2. Fan Coil Units Models SVC, SVN, SHC, SHN to 8.75kW to 4.90kW. 94 to /h

Ceiling Mount Type Ventilating Fan

Transcription:

Trench Heating/Cooling Katherm HK Tested acc. to: BS EN 16430

Improved performance The narrower trench width and shallower trench height of the totally redesigned Katherm HK delivers an optimised output range for on-demand heating and cooling from low level. With its new incremental lengths, the Katherm HK is the solution for the most diverse building requirements. Innovative The Katherm HK has been further developed in the Kampmann Research & Development Center. With revised components, like the tangential fan, high-output coil and the modified design chassis, the new Katherm HK provides optimised air flow foreven higher performance. 1 3

Hygiene-compliant It s unique! Thanks to improved condensate drainage in cooling mode, coupled with the ease of cleaning of the condensate tray, the Katherm HK is totally hygienic! Energy-efficient State-of-the-art EC tangential fans with low power consumption ensure energy-saving operation combined with low sound levels. The fixing system in the floor trench, perfected over many years, which also incorporates sound decoupling ensures that the unit can be quickly and easily removed for cleaning and maintenance. 2 3

Perfectly controlled The unit comes with a factory-fitted BMS interface to allow precise control of the performance. Air flow-optimised The arrangement and air guidance have both been optimised on the Katherm HK and guarantee maximum comfort levels in all rooms.the unit is enhanced with air flow-optimised roll-up and linear grilles. 3 3

Katherm HK at a glance 1 - Frame profile matching the grille finish 2 - Junction and control box 3 - Cleanable condensate tray 4 - Eurokonus connection 5 - Tangential fan fixing 6 - High-performance coil 7 - Air guide panels 8 - Highly efficient EC tangential fan 9 - Filter (optional) 10 - Raised floor brackets 11 - Condensate pump 12 - Roll-up grille: aluminium, natural anodised 1 6

Katherm HK with short-cut optimised air outlet The diagram shows the the air flow of short-cut optimised heating/cooling trenches in cooling mode. Façade surface temperature 28 C Reference air temperature 24 C 1800 mm (1500-2100 mm) With the short-cut optimised model the air at the façade rises significantly higher, blends and penetrates deeper into the room at a higher temperature. The result is a more even temperature distribution and higher comfort in the occupied zone. 17 C 26 C ca. 500-800 mm 750 mm The development and design of the Katherm HK have been optimised to minimise the short-cut as far as technically possible. All performance data refer to the reference air temperature measured at a distance of 2 m from 25 C CHW 6/12 C 2 m the façade, 0.75 m above floor level. Katherm HK: Short-cut optimised air outlet 2 6

Junction and control box control options: KaControl (-C1) or BMS-Interface/electromechanical (-00) incl. factory fitted transformer Condensate tray/pump for safe discharge of the condensate and simultaneous air guidance specifically designed for simple cleaning in line with the hygienic standards can be removed to the room side for ease of cleaning condensate pump (accessory) to drain condensate, if needed 3 6

Highly efficient EC tangential fan energy-saving, with flow-optimised impellers, cascaded arrangement as a continuous fan belt easily removeable, plug & play fan even air flow through convector robust and whisper-quiet motor design continuously variable control via external 0-10 V signal 4 6

Tangential fan fixing easy removal of tangential fan without tool novl coupling/cone pin system simultaneous sound decoupling Air guide panels act as a finger guard for the tangential fan, filter frame, airflow baffle, grille seat and reinforcing stay to strengthen the trench 5 6

High-performance coil made of the proven combination of copper/aluminium optimised for air flow and thermal performance Eurokonus valve connection Supply air module for inducing pre-conditioned supply air primary air volume can be adjusted max. air volume per module = 60 m³/h amount of modules selectable depending on trench length change in trench dimensions: trench width + 20 mm; trench height + 35 mm 6 6

Control options KaControl room automation KaControl technology factory-integrated for setting up entire networked systems based on the KaControl interfaces for KNX or Modbus building automation as an optional plug-in group 0 10 V analogue input for control of fan and valve via a single data point design room control unit with intuitive user navigation integrated timer program RPM max. min. 0 V 5 V 10 V 0 1.5 V = device OFF 1.5 10 V = fan speed min... 100 % BMS-Interface/electromechanical (-00) power supply: 230 V/50 Hz via factory fitted transformer fan speed control 0 100 % via 0 10 VDC BMS contact valve control, direct by BMS Control signal 0-10 VDC

Performance data according to BS EN 16430 Unit length Unit width Unit height Heat output 1) Sensible cooling output 2) Sound pressure level 3) 4) Sound power level 4) A B C 2-pipe 4-pipe 2-pipe 4-pipe [mm] [mm] [mm] [W] [W] [W] [W] [db(a)] [db(a)] 915 320 130 1442 923 286 287 27 35 1200 320 130 2483 1657 501 499 29 37 1700 320 130 4523 3054 937 931 31 39 2000 320 130 5132 3589 1068 1061 32 40 2500 320 130 7177 4996 1507 1495 33 41 3000 320 130 9223 6405 1948 1931 34 42 950 290 160 1697 1067 321 313 24 32 1200 290 160 2830 1837 542 529 26 34 1700 290 160 4526 3042 863 842 28 36 2000 290 160 5887 3978 1130 1103 29 37 2500 290 160 7584 5191 1443 1409 30 38 3000 290 160 9854 6758 1924 1878 31 39 1) Heat output per Katherm HK, with an average speed setting 60 %, at LPHW 75/65 C, room air temperature 20 C 2) Cooling output per Katherm HK, with an average speed setting 60 %, at CHW 6/12 C, room air temperature 24 C, 50 % relative humidity 3) The sound pressure levels were calculated with an assumed room insulation of 8 db(a). This corresponds to a distance of 2 m, a room volume of 100 m3 and a reverberation time of 0.5 s, at 60 % fan speed. 4) Sound pressure level < 20 db (A) and sound power level < 28 db (A) outside the usual measuring and audible range. 1 3

Dimensions Top view Unit length Unit width Unit height A B C [mm] [mm] [mm] 915 320 130 1200 320 130 1700 320 130 2000 320 130 2500 320 130 3000 320 130 950 290 160 1200 290 160 1700 290 160 2000 290 160 2500 290 160 3000 290 160 Frontview Sectional view 2 3

Cross sections Katherm HK 320, 4-pipe Katherm HKZ 320, 4-pipe, with supply air connections Katherm HK 290, 4-pipe Katherm HKZ 290, 4-pipe, with supply air connections 3 3

Choice of grilles 1 2 3 1 Aluminium, natural anodised 2 Aluminium, brass anodised 3 Aluminium, bronze anodised 4 Aluminium, bronze finish 5 Aluminium, black anodised 6 Aluminium, basalt grey painted DB 703 4 5 6 7 Stainless steel 8 Stainless steel, polished 9 Brass, natural 7 8 9 Aluminium roll-up grille, natural anodised: double T-profile roll-up grille bar dimension 18 x 5 mm (stainless steel 18 x 6 mm) bar spacing 9 mm (stainless steel 10.5 mm) connections made of corrosion-proof steel springs with spacers in a matching colour 65 % free area

Kampmann offers you the following service benefits: Benefits for you! on-site consultation design support system solutions site-surveys After Sales Service Find your contact person here: Kampmann.co.uk/contact