CVE2/CVSE2 CVE3/CVSE3

Similar documents
Pilot operated 2 port valve for dust collector control (pulsejet valve) Common specifications Air operated type. Solenoid valve mounted type Item OUT

PDVE4 Series PDVE4 20A 3T AC100V. Explosion proof 2 port solenoid valve for dust collector control (explosion proof pulsejet valve)

Pilot kick type 2 port solenoid valve for dry air (general purpose valve) ADK11-Z Series. NC (normally closed) type

AB41E4-Z Series. Pressure and explosion proof structure d2g4 (flame-proof grade 2, ignitability G4) NC (normally closed) type. Port size: Rc1/4, Rc3/8

Discrete air operated 2 port valve (compact cylinder valve) NC (normally closed) type

New Products. 3 Port Solenoid Valve with Spool Position Detection SNP Series

HN B G1/US B G2/US B G3

NO (normally closed) type Common supply type (port C pressurization) MPa MPa MPa C C

PD3/PDV3-20A/25A/40A Series

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

General purpose direct acting 2, 3 port solenoid valve

Pilot operated 2 port solenoid valve (general purpose valve) AP11/AP12 Series. Air, water, kerosene, oil (50 mm 2 /s or less) -10 to to 60 B

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

3GA1/2/3, 4GA1/2/3 Series Applicable cylinder bore size: ø20 to ø100

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

Vacuum pump system type

3 Port Solenoid Valve Direct Operated Poppet Type

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

New Products COMPACT PILOT OPERATED SOLENOID VALVE FOR WATER. Lightweight and large flow rate, low power consumption Improved corrosion resistance!

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

HVB/HVL. Solenoid valve for high vacuum. For vacuum, inert gas, air, nitrogen CONTENTS. Overview

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

MYB1/MYG1 Series DC12V. Metal free 2, 3 port solenoid valve for chemical liquid

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero.

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5 Port Solenoid Valve

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Coolant Valve. Air Operated/External Pilot Solenoid

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Energy efficiency and Flow

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

3MA0/3MB0. Small pneumatic valve. 3 port direct acting valve CONTENTS. Space saving Valves are compactly designed with widths of 10 mm

Discrete direct acting 3 port solenoid valve (general purpose valve) AG31/AG41 Series. Universal type Port size: Rc1/8, Rc1/4, Rc3/8

Series AV2000/3000/4000/5000

Transmitters: Relay Valve VR4151/4152

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Flow characteristics Max. (1) b Standard Specifications. P Manual override.

High Pressure Coolant Valve

Process Valve/Series VN

3 Port Solenoid Valve

Pilot Operated 2 Port Solenoid Valve for Dry Air

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

3-in-1 package (solenoid valve + governor + solenoid valve) realizes compact piping in double shutoff application.

Discrete direct acting 3 port solenoid valve (general purpose valve) Universal type Port size: Rc1/8, Rc1/4, Rc3/ to to 60 B

5 Port Solenoid Valve

3 Port Solenoid Valve

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

Series variation. Auxiliary valve. Quick exhaust, and circuit switchover valves, etc. are available. Port size (Rc) Page. Model Product appearance

Pilot Operated 2 Port Solenoid Valve for Dry Air

Free position locking flat and compact cylinder UFCD Series

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Series SYJ300/500/700

3 Port Solenoid Valve

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

Speed Controller High Flow

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Specifications VH600. Ambient temperature and operating fluid temperature. Operating angle Lubrication. Semi-standard

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

Series VP3145/3165/3185

5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type. Closed Center DS3330/DS3300. How to Order - Body Ported Type

Standard Specifications. Fluid Standard specifications. VH600 Ambient and fluid temperature Operating angle Lubrication. Optional Specifications

Plug-in manifold W4G4 Series

Transmitters: Relay Valve

Discrete direct acting 2 port solenoid valve (general purpose valve) AB31 AB41 Series NC (normally closed) type AB42 Series NO (normally open) type

The valve body is prepared in two different colors enabling the user to opt for either of the two according to operational environment.

2 port pilot operated solenoid valve

Discrete direct acting 3 port solenoid valve (general purpose valve) NC pressurization type. Port size: Rc1/8, Rc1/4, Rc3/8

Conventional specification. External Pilot air specification 0 ~ 0.7. Compact, yet keeps large capacity.» Limited space can be utilized.

F1000/F3000/F4000/F8000 Series

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VP3145/3165/3185

NAMUR Interface 5 Port Solenoid Valve

3, 5 port pilot operated valve Pneumatic valve / master valve. Discrete valve. Manifold

Coolant Valve. VNC Series. Cylinder actuation by pilot air

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Light weight clamp cylinder CAC-N32/40 Series Light weight position locking clamp cylinder UCAC-N32/40 Series

5 Port Solenoid Valve

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

Manifold Specifications Stacking Type

4F0/1/2/3 Series. Min. working pressure MPa Refer to the individual specifications below to 60 Lubrication Not required (when lubricating,

HMV/HSV. Manual switching valve. 4 port valve

Exclusively for air pressure system and air-hydro circuit control

Transcription:

Overview This is a reliable 2, 3 port coolant valve with cylinder drive method. This valve for tool machine cutting oil or coolant control incorporates a metal seal to prevent the entry of cutting chips, abrasive grains and foreign debris, and ensures highly reliable control. The air operated type and solenoid valve mounted type are available. These can be used in precise machines. Features High corrosion resistant materials Cast iron body, and stainless steel metal seal used in valve seat. NBR or FKM packing seal can be selected. Materials optimum for coolant are used. Certain operation Certain operation is enabled with external pilot air operated cylinder. Water hammer prevented (Only 2 port valve) Resistant to foreign matter A metal seal is used. Usable in flammable environment. () CVE2/CVSE2 CVE3/CVSE3 (Coolant valve) Air operated 2, 3 port valve (coolant control) CONTENTS For coolant Series variation 700 Safety precautions 702 roduct introduction 706 Low pressure (0.5 Ma and 1.0 Ma), 2 port valve CVE2, CVE22-05/10 708 CVSE2, CVSE22-05/10 708 Medium pressure (1.6 Ma and 3.0 Ma), 2 port valve CVE2, CVE22-16/30 718 CVSE2, CVSE22-16/30 718 High pressure (7.0 Ma), 2 port valve CVE2, CVE22-70 726 CVSE2, CVSE22-70 726 Medium/high pressure (3.5 Ma and 7.0 Ma), 3 port valve CVE3-35/70 732 CVSE3-35/70 732 Low pressure (0.3 Ma), 3 port valve CV3E 744 CVS3E 744 Electronic Catalog file list 746 Always read the precautions in the Introduction and page 702 before starting use. HNB/G USB/G FAB/G FGB/G FVB FWB/G FHB FLB AB AG A/ AD AK/ ADK For dry air Explosion proof HVB/ HVL SAB/ SVB N/NA/ NV CHB/G MXB/G Other G.. systems D/FAD/ J CVE/ CVSE CE/ CD Medical analysis Custom order Coolant valve Air operated 2, 3 port valve 699

Series variation Air operated 2, 3 port valve (coolant control) (Coolant valve) No. of port Category Model Working pressure range Ma Rc3/8 Rc1/2 2 port 3 port Low pressure Medium pressure High pressure Medium pressure Low pressure High pressure CVE2-***-05 CVSE2-***-05 CVE2-***-10 CVSE2-***-10 CVE2-***-16 CVSE2-***-16 CVE2-***-30 CVSE2-***-30 CVE2-***-70 CVSE2-***-70 CV3E-***-03 CVS3E-***-03 CVE3-***-35 CVSE3-***-35 CVE3-***-70 CVSE3-***-70 0 to 0.5 0 to 1.0 0 to 1.6 0 to 3.0 0 to 7.0 0 to 0.3 0 to 3.5 0 to 7.0 700

HNB/G ort size Rc3/4 Rc1 Rc1 1/4 32 flange Rc1 1/2 40 flange Rc2 50 flange 65 flange 80 flange age 708 708 708 708 718 718 718 718 726 726 744 744 732 732 732 732 USB/G FAB/G FGB/G FVB FWB/G FHB FLB AB AG A/ AD AK/ ADK For dry air Explosion proof HVB/ HVL SAB/ SVB N/NA/ NV CHB/G MXB/G Other G.. systems D/FAD/ J CVE/ CVSE CE/ CD Medical analysis Custom order Coolant valve Air operated 2, 3 port valve 701

Safety precautions Always read this section before starting use. Air operated 2, 3 port valve (coolant valve) (CVE/CVSE) Design & Selection 1. Safety designing CAUTION Leakage current from other fluid control components When operating the solenoid valve with a programmable controller, etc., check that the output leakage current from the programmable controller is within the following specifications. Failure to observe this could lead to malfunctions. CR circuit Triode AC switch rogrammable controller side C R 2. Working fluid WARNING Leakage current Solenoid valve 100 VAC : 3 ma or less 200 VAC : 1.5 ma or less 24 VDC : 1 ma or less must be maintained. Working fluid The compatibility has not been evaluated with all coolants. articularly, if coolant contains high levels of chlorine or sulfur, materials used at wetted parts could be adversely affected. Confirm the compatibility when making a selection. Non-corrosive fluids refer to fluids that do not affect or are not affected when they contact the valve's wetted part materials. Wetted part materials: cast iron (nickel plating), stainless steel, nitrile rubber or fluoro rubber, and epoxy resin adhesive. External pilot air (1) Drainage measures - Compressed air contains high levels of drainage (water, oxidized oil, tar, foreign matter) that can significantly reduce the reliability of pneumatic components. As measures against drain, improve air quality by dehumidifying with an after cooler or dryer, removing foreign matter with a filter, and removing tar with a tar removal filter, etc. (2) re-lubrication - This series is pre-lubricated, so no lubricator is required. However, once lubrication has been started, it must be continued so that the lubricant is not used up. For lubrication, use the turbine oil Class 1 ISO VG32 (#90) or equivalent. (3) Filter - Install a filter with a 5 μm or less filter element. 3. Working environment WARNING CVSE Series cannot be used in an explosive gas atmosphere. When using in an explosive gas atmosphere, change to the CVE Series, and provide a separate explosion proof solenoid valve on the pilot air circuit. If there are high levels of dust in the area, install a downwardfacing silencer or elbow joint on the exhaust port so that dust does not enter. When using in a place where water splashes on the valve, take appropriate measures to protect it. 4. How to use CAUTION ilot air pressure Use pilot air pressure in accordance with the specifications. Installation & Adjustment 1. iping CAUTION Do not pipe using the solenoid valve section. There is a risk of damage. (For solenoid valve mounted type) When piping the CVE or CVSE Series, pay attention to the supply ports on the unit and pilot operation sides. CVE2 CVE22 CVSE2/CVSE22 CVE3 CVSE3 Unit side supply port IN ilot operation side supply port X Y Y Note: ipe the unit side supply port so that the arrow on the body matches the fluid flow direction. If supplied in reverse, internal components could be damaged when the valve operates. 702

CVE/CVSE Series Individual precautions 2. Wiring CAUTION Wiring of solenoid valve mounted type (1) Refer to connections in pages 54 to 55 in the Introduction when wiring to a DIN terminal box or T type terminal box. (2) The size of the screw for the junction box outlets of the DIN terminal box can be changed from g9 to G1/2 using the optional connector below. HNB/G USB/G FAB/G FGB/G 16 Hexagon head 24 FVB FWB/G FHB g9 G1/2 : CVS2-CONNECTOR-F4-202936 FLB (3) Coil direction can be changed 180. To reverse the electrical connection direction, rotate only the coil. Do not lose internal parts when removing the coil. AB AG A/ AD AK/ ADK 1. Maintenance & inspection CAUTION ilot air pressure Use pilot air pressure in accordance with the specifications. If water hammer occurs when a 3 port coolant valve for medium/high pressure operates, reduce the noise as follows. (1) Install a metering valve on the valve IN side, then adjust the metering valve to reach the required flow. If these countermeasures fail, contact CKD. 2. Assembling & disassembling WARNING A spring is used in the cylinder cover. When disassembling this type, the spring could pop out and cause injuries, so take care. The NC (normally closed) type 2 port valve has a snap ring to prevent the spring from popping out. Do not remove the snap ring. During Use & Maintenance For dry air Explosion proof HVB/ HVL SAB/ SVB N/NA/ NV CHB/G MXB/G Other G.. systems D/FAD/ J CVE/ CVSE CE/ CD Medical analysis Custom order Coolant valve Air operated 2, 3 port valve 703

CVE/CVSE Series @ Assembling pilot solenoid valve (for solenoid valve mounted type) If the pilot solenoid valve has been disassembled, assemble it as follows. (1) Coil side Disassembling Loosen the cross headed pan head machine screw, and lift up the coil assembly. The outer spring, plunger assembly and O ring can be removed. Reassembling Set the parts in the sequence of the O ring, plunger assembly, outer spring and coil assembly. Tighten the cross headed pan head machine screw with a torque of 0.7 to 1.1 N m. (2) Cover side Disassembling Loosen the flat headed cross cut screw, and remove the cover. The valving element spring, valving element guide assembly and O ring can be removed. Reassembling Set the parts in the sequence of the O ring, valving element guide assembly, valving element spring and cover. Tighten the flat headed cross cut screw with a torque of 0.7 to 1.1 N m. Cross headed pan head machine screw Coil assembly O ring Body assembly O ring Note 2 Outer spring lunger assembly Note 1: Do not lose the components such as springs during disassembly. Note 2: The coil assembly direction can be changed 180. Loosen the cross headed pan head machine screw to change the direction. Note 3: Turbine oil is applied to the plunger as a lubricant. Valving element guide assembly Valving element spring Cover Flat headed cross cut screw of pilot solenoid valve (actuator assembly kit) for CVSE *1 CVSE2-ACTUATOR 0 Rated voltage Note 1: Indicate the coil option symbol in field *1. Note 2: Consult with your CKD Sales Representative about the solenoid valve (actuator assembly kit) for CVS3E. Gasket direction (for solenoid valve mounted type) The gasket has an orientation. Check the orientation when reassembling. Gasket ort R ort R CVSE2 NC (normally closed) type CVSE22/CVSE3 NO (normally open) type, 3 port valve 704

Air operated 2 port valve for high pressure (coolant valve) CVSE2/CVSE22-70 Series CVE2/CVE22-70 Series NC (normally closed) type, NO (normally open) type ort size: Rc3/8 to Rc1 High pressure 7.0 Ma Refer to Ending 17 for details. JIS symbol CVE2 (air operated type) : NC type X OUT IN CVE22 (air operated type) : NO type Y OUT IN CVSE2 (solenoid valve mounted type) : NC type OUT IN CVSE22 (solenoid valve mounted type) : NO type OUT IN Common specifications CVE2/CVSE2 CVE22/CVSE22 Actuation NC (normally closed) type NO (normally open) type Working fluid Coolant, other non-corrosive fluids (*1) Fluid viscosity Working pressure range mm 2 /s Ma 500 or less 0 to 7.0 Withstanding pressure (water) Ma 14 Fluid temperature Ambient temperature Valve seat leakage Mounting attitude ilot air pressure C C cm 3 /min. Ma -10 to 60 (no freezing) -10 to 60 20 or less (water) Free 0. to 0.7 *1: Fluids that do not affect cast iron (nickel plating), stainless steel, copper, nitrile rubber or fluoro rubber Electric specifications (solenoid valve mounted type common specifications) Rated voltage (*2) Apparent power (VA) ower consumption (W) Heat proof class Holding Starting AC DC 100 VAC (50/60 Hz), 110 VAC (60 Hz); 200 VAC (50/60 Hz), 220 VAC (60 Hz); 24 VDC 3.6 (50 Hz), 2.8 (60 Hz) 11 (50 Hz), 9 (60 Hz) 1.9 (50 Hz), 1.5 (60 Hz) 2.0 B rotective structure (IEC standards 529) DIN terminal box (g9) T type terminal box (G1/2) IX5 IX5 *2: Allowable voltage range must be within ±10% of the rated voltage. Individual specifications for 7.0 Ma Item CVE2(2)/CVSE2(2)-10A-70 CVE2(2)/CVSE2(2)-15A-70 CVE2(2)/CVSE2(2)-20A-70 CVE2(2)/CVSE2(2)-A-70 ort size Rc3/8 Rc1/2 Rc3/4 Rc1 Orifice (mm) 6.5 8 10.5 13 Cv flow factor 1.7 2.8 4.7 7.0 ilot Weight (kg) port size CVE2(2) CVSE2(2) 1.4 1.5 Rc1/8 2.4 2.5 3.9 4.0 6.1 6.2 726

How to order CVE2 2 20A 70 0 B CVSE2 2 15A 70 0 2G S 1 CVE2/CVSE2-70 Series CVE2 CVSE2 Symbol Descriptions A Actuation A Actuation Blank NC (normally closed) type 2 NO (normally open) type B ort size B ort size 10A Rc3/8 15A Rc1/2 20A Rc3/4 A Rc1 CVE2 (2 port) C Working pressure range C Working pressure range CVSE2 70 0 to 7.0 Ma (2 port) D Body/sealant combination D Body/sealant combination Body Sealant 0 Standard Cast iron (plating) Nitrile rubber B Option Cast iron (plating) Fluoro rubber E Coil E Coil 2G DIN terminal box (g9) 2H DIN terminal box + light (g9) 3T T type terminal box (G1/2) <Example of model number> 3R T type terminal box + light (G1/2) CVSE22-15A-70-02GS-1 F Other options F Others : CVSE2 : (2 port) *1 Option Blank No options A Actuation : NO (normally open) type *2 S Surge suppressor *3 B ort size : Rc1/2 *4 B Mounting plate C Working pressure range G : 0 to 7.0 Ma Assembly direction G Assembly D Body/sealant combination *5 direction Blank No options : Body - cast iron (plating), sealant - nitrile rubber X Cylinder cover 90 rotation E Coil : DIN terminal box (g9) Y Cylinder cover 180 rotation F Other options : Surge suppressor Z Cylinder cover 270 rotation G Assembly direction : No options R Coil 180 reverse rotation (solenoid valve mounted type) H Voltage : 100 VAC (50/60 Hz), 110 VAC (60 Hz) Refer to the following diagram for the layout drawing. *1: Indicate SB in F to select both surge suppressor and mounting plate. H Voltage H Voltage *2: The surge suppressor is mounted in the terminal box. 100 VAC (50/60 Hz) *3: A manual override (non-locking) is provided as standard for the solenoid valve 1 mounted type. 110 VAC (60 Hz) *4: The mounting plate is enclosed with the product. 200 VAC (50/60 Hz) *5: An optional assembly direction cannot be selected for the air operated type. 2 *6: Clockwise rotation angles are shown as viewed from above with IN port 220 VAC (60 Hz) facing right. 3 24 VDC G Assembly direction CVSE2 (solenoid valve mounted type) *6 Symbol Direction Blank (standard) Without rotation X Cylinder cover 90 rotation Y Cylinder cover 180 rotation Z Cylinder cover 270 rotation Arrangement R Coil reverse rotation HNB/G USB/G FAB/G FGB/G FVB FWB/G FHB FLB AB AG A/ AD AK/ ADK For dry air Explosion proof HVB/ HVL SAB/ SVB N/NA/ NV CHB/G MXB/G Other G.. systems D/FAD/ J CVE/ CVSE CE/ CD Medical analysis Custom order Coolant valve for high pressure Air operated 2 port valve 727

CVSE2-70 Series Internal structure and parts list CVSE2 6 1 2 3 7 4 5 OUT Dimensions IN 8 9 No. 1 2 3 4 5 6 7 8 9 arts name Cylinder cover iston Adaptor iston rod Body ilot solenoid valve Spring Rod packing seal Main valving element Material ADC12 A2017 SUS303 SUS304 FCD450 - SW NBR (FKM) SUS420J2 Aluminum die casting Aluminum Stainless steel Stainless steel Cast iron (plating) - iano wire Nitrile rubber (fluoro rubber) Stainless steel DIN terminal box (g9) CVSE2/CVSE22-10A~A-70-*2G N 22 53 44 15.5 Rc1/8 18 Non-locking manual override 44.5 (38) g9 Applicable cable (OD ø4.5 to ø7) E M5 Exhaust port D 2-G 2 x 2-K C L M A * Shown without optional assembly direction. A B C D E F G B F K L M N CVSE2/CVSE22-10A-70-*2G 60 28 22 92.5 159.5 63 Rc3/8 M6 thread length 9 38 20 57.5 CVSE2/CVSE22-15A-70-*2G 80 32 114 184 77 Rc1/2 M8 thread length 10 40.5 64.5 CVSE2/CVSE22-20A-70-*2G 90 40 29 136.5 210.5 95 Rc3/4 M8 thread length 10 45.5 72.5 CVSE2/CVSE22-A-70-*2G 110 48 33.5 149.5 228 113 Rc1 M12 thread length 14 49 45 82.5 728

Internal structure and parts list CVE2-70 Series CVE2 HNB/G USB/G FAB/G FGB/G 1 FVB 2 6 FWB/G 3 7 FHB 4 5 OUT Dimensions CVE2/CVE22-10A to A-70-** 8 IN No. 1 2 3 4 5 6 7 8 arts name Cylinder cover iston Adaptor iston rod Body Spring Rod packing seal Main valving element N 14.6 Material ADC12 A2017 SUS303 SUS304 FCD450 SW NBR (FKM) SUS420J2 2-Rc1/8 Aluminum die casting Aluminum Stainless steel Stainless steel Cast iron (plating) iano wire Nitrile rubber (fluoro rubber) Stainless steel FLB AB AG A/ AD AK/ ADK For dry air Explosion proof HVB/ HVL SAB/ SVB N/NA/ NV 10 CHB/G MXB/G Other G.. systems D/FAD/ J D E CVE/ CVSE 2-G CE/ CD Medical analysis 2 x 2-K L Custom order M B A F * The pilot pressurization port is port X for the NC type and port Y for the NO type. A B C D E F G K L M N CVE2/CVE22-10A-70-* CVE2/CVE22-15A-70-* CVE2/CVE22-20A-70-* CVE2/CVE22-A-70-* 60 80 90 110 28 32 40 48 22 29 33.5 88.5 110 132.5 145.5 128.5 153 179.5 197 63 77 95 113 Rc3/8 Rc1/2 Rc3/4 Rc1 M6 thread length 9 M8 thread length 10 M8 thread length 10 M12 thread length 14 38 40.5 45.5 49 20 45 46 53 61 71 C Coolant valve for high pressure Air operated 2 port valve 729

CVE2/CVSE2-70 Series Optional dimensions Mounting plate CVE2/CVE22-10A to A-70-** B / B-R / B-Y CVSE2/CVSE22 : Installation oval hole L S Q R U T * Figure shows B. Mounting plate CVE2/CVE22-10A to A-70-** B-X / B-Z CVSE2/CVSE22 : Installation oval hole L S T Q R U * Figure shows B-X. L Q R S T U CV*E2*-10A-70-*B 38 9 x 12 85 100 3.2 45 CV*E2*-15A-70-*B 40.5 11 x 15 1 145 35 3.2 62.5 CV*E2*-20A-70-*B 45.5 11 x 15 1 145 35 3.2 71.5 CV*E2*-A-70-*B 49 14 x 20 160 190 40 4 84 730

Optional dimensions CVE2/CVSE2-70 Series Optional dimensions T type terminal box (G1/2) T type terminal box with light (G1/2) CVSE2/CVSE22-*-70-* 3T 3R HNB/G USB/G (85.5) 15.5 FAB/G 35 (54.5) FGB/G FVB FWB/G FHB FLB AB AG A/ AD AK/ ADK For dry air Explosion proof HVB/ HVL SAB/ SVB N/NA/ NV CHB/G MXB/G Other G.. systems D/FAD/ J CVE/ CVSE CE/ CD Medical analysis Custom order Coolant valve for high pressure Air operated 2 port valve 36.5 46 16 G1/2 731

CVE/CVSE Series Electronic Catalog file list Air operated 2, 3 port valve (coolant control) (coolant valve) Air operated 2 port valve for low pressure (pages 714 to 716) CVE2/22-10A-5/10 CVE2/22-15A-5/10 CVE2/22-20A-5/10 CVE2/22-A-5/10 CVE2/22-32A-5/10 CVE2/22-32F-5/10 CVE2/22-40A-5/10 CVE2/22-40F-5/10 CVE2/22-50A-5/10 CVE2/22-50F-5/10 CVE2/22-65F-5/10 CVE2/22-80F-5/10 Option and accessory (mounting plate) Folder name CVE2 Folder name CVSE2 DXF Filename cve2_22_10a_5_10 cve2_22_15a_5_10 cve2_22_20a_5_10 cve2_22_a_5_10 cve2_22_32a_5_10 cve2_22_32f_5_10 cve2_22_40a_5_10 cve2_22_40f_5_10 cve2_22_50a_5_10 cve2_22_50f_5_10 cve2_22_65f_5_10 cve2_22_80f_5_10 cve2_f 2 port valve for low pressure with solenoid valve (pages 712, 713, 716) CVSE2/22-10A-5/10 CVSE2/22-15A-5/10 CVSE2/22-20A-5/10 CVSE2/22-A-5/10 CVSE2/22-32A-5/10 CVSE2/22-32F-5/10 CVSE2/22-40A-5/10 CVSE2/22-40F-5/10 CVSE2/22-50A-5/10 CVSE2/22-50F-5/10 CVSE2/22-65F-5/10 CVSE2/22-80F-5/10 Option and accessory (T type terminal box, mounting plate) DXF Filename cvse2_22_10a_5_10 cvse2_22_15a_5_10 cvse2_22_20a_5_10 cvse2_22_a_5_10 cvse2_22_32a_5_10 cvse2_22_32f_5_10 cvse2_22_40a_5_10 cvse2_22_40f_5_10 cvse2_22_50a_5_10 cvse2_22_50f_5_10 cvse2_22_65f_5_10 cvse2_22_80f_5_10 cvse2_f Electronic Catalog file list is applied to "CAD DATA 2006". MICRO CADAM Filename (GROU: CAD, USER: STDLIB) CKD-CVE2/22-10A-5/10 CKD-CVE2/22-15A-5/10 CKD-CVE2/22-20A-5/10 CKD-CVE2/22-A-5/10 CKD-CVE2/22-32A-5/10 CKD-CVE2/22-32F-5/10 CKD-CVE2/22-40A-5/10 CKD-CVE2/22-40F-5/10 CKD-CVE2/22-50A-5/10 CKD-CVE2/22-50F-5/10 CKD-CVE2/22-65F-5/10 CKD-CVE2/22-80F-5/10 CKD-CVE2-F Electronic Catalog file list is applied to "CAD DATA 2006". MICRO CADAM Filename (GROU: CAD, USER: STDLIB) CKD-CVSE2/22-10A-5/10 CKD-CVSE2/22-15A-5/10 CKD-CVSE2/22-20A-5/10 CKD-CVSE2/22-A-5/10 CKD-CVSE2/22-32A-5/10 CKD-CVSE2/22-32F-5/10 CKD-CVSE2/22-40A-5/10 CKD-CVSE2/22-40F-5/10 CKD-CVSE2/22-50A-5/10 CKD-CVSE2/22-50F-5/10 CKD-CVSE2/22-65F-5/10 CKD-CVSE2/22-80F-5/10 CKD-CVSE2-F 746

CV/CVS Series Electronic Catalog file list Air operated 3 port valve (coolant control) (coolant valve) 3 port valve for low pressure (page 745) CV3E-20A-3 CV3E-A-3 CVS3E-20A-3 CVS3E-A-3 Option and accessory (T type terminal box, mounting plate) Accessory (T type terminal box, T type terminal box + light) Folder name CV3E DXF Filename cv3e_20a_3 cv3e_a_3 cvs3e_20a_3 cvs3e_a_3 cv_e_f cvs2_f Electronic Catalog file list is applied to "CAD DATA 2006". HNB/G MICRO CADAM USB/G Filename (GROU: CAD, USER: STDLIB) CKD-CV3E-20A-3 FAB/G CKD-CV3E-A-3 CKD-CVS3E-20A-3 FGB/G CKD-CVS3E-A-3 CKD-CV*E-F FVB CKD-CVS2-F FWB/G FHB FLB AB AG A/ AD AK/ ADK For dry air Explosion proof HVB/ HVL SAB/ SVB N/NA/ NV CHB/G MXB/G Other G.. systems D/FAD/ J CVE/ CVSE CE/ CD Medical analysis Custom order Coolant valve Air operated 2, 3 port valve 747