CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Similar documents
CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

CBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls

Electromagnetic Particle Clutches and Brakes Models: POC, PHC-R, PMC-A3, POB, PRB and PTB-BL3 P Performance Manual

Safety Sentry Electronic Breakaway Switch

Gen 2 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

Preassembled Clutch/Electrically Released Brake Module

12 Volt Utility Controller for 4, 6 or 8 Brakes No P

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB Size 50, 100, 180

Warner Electric UNIBRAKE Motor Brakes

SFP-250 and SFP-400. Installation Instructions. An Altra Industrial Motion Company P-231-WE

ERD Electrically Released Brakes

Preassembled Clutch/Electrically Released Brake Module

Preassembled Clutch/Brake Module

AT Clutch Major Service Sizes 25, 55, 115

MTB II Modular Tension Brakes

Compressor Clutch Replacement Procedure

Electromagnetic Particle Brakes Model: PRB-H

Heavy Duty Industrial Foot Switches

Gen 2 Clutch/Brake UniModule UM-50, UM-100, UM-180

12 Volt Utility Controller for 4, 6, or 8 Brakes No

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

Utility Controller Hand Air Operated

TB Series Brakes Tension Control System

Compressor Clutch Replacement Procedure

Procedure to Install the New Autogap components in ER-1225 and ER825 Brake with inverted Armature Hub

Gen 2 Clutch/Brake UniModule UM-50, UM-100, UM-180

Installation & Operation Manual. Electrak 1 Series / Electromechanical Linear Actuators Limit Switch, & Potentiometer Feedback, and Long Life Models

Installation Instructions

Wrap Spring Clutches & Brakes CB & Super CB Series P-2026-WE SM592-gb-02/08

Primary Brake Spline Drive Armature PB-825, PB-1000, PB-1225, PB-1525

Electro-Brake 375, 475, 650, 825, 1000, 1225

12-1/4 x 3-1/2 Electric Wheel Brake

Service & Installation Instructions. An Altra Industrial Motion Company P WE Vented. Enclosed Version Optional

Electromagnetic Toothed Clutch E330

Installation Instructions

Pneumatic Single Disc and Dual Disc Brakes P250 and P620

Primary Brakes PB-120, PB-170, PB-250, PB-400

Advanced Technology Tension Clutches

Electro-Packs EP-170, 250, 400, 500, 825, 1000, 1525

PB-500 Pin Drive, PB-500 Spline Drive PB-650 Pin Drive

Installation & Operation Manual. Electrak 10 Series / Electromechanical Linear Actuator

Electrically Released Brakes FB-375, 475, 650

A30 Single Range Tensioncells

Installation Instructions

Hydraulic Multi-Disc Brake H420 P-2067-WE SM320gb - rev 02/09

Electrically Released Brakes FB-375, 475, 650

Electro-Module EM-50, EM-100, EM-180, EM-210, EM-215

SFC-825, SFC-1000, SFC-1225, SFC-1525 Heavy Duty Clutch Coupling and SFC-1525 High Torque Heavy Duty Clutch Coupling

Residential, TG-2000 and Commercial MagStop Clutch/Brake

Linear Actuators P-6150-WL

Hydraulic Multidisc Clutch H 110 VAR00 P-2066-WE SM301gb - rev 02/09

Pro-Series/ Electromechanical Linear Actuator

Blade Brake Clutch Application Guide P

Fan Backstop Clutches Models HFB & VFB

BULLETIN 2212 P Installation Instructions. thru 1027

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

HE1U 1248 BMS High Efficiency 1U AC to DC Power Supply Owners Guide SPECIFICATIONS

SOLAR DASH CHARGING SYSTEM USER GUIDE

BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control

Special Purpose Overrunning Clutches ep 300 thru 1027 (less Oil Seals)

INVERTER HARNESS INSTALLATION FOR FREIGHTLINER CASCADIA

AC10 Measuring System

BMRX Series ROTARY LEVEL CONTROL

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

Adjustable Torque Controls

RU BMS Power Supply and Battery Management System Owners Guide

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Lint Slide Grid Moist Air Applicator

PVI 60KW, PVI 82KW, PVI 95KW

A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS SYSTEM OPERATION GREEN INDICATOR LIGHT

Generator Start Control Module

Generator Start Control Module

TBX10A INSTALLATION/OWNER'S MANUAL 10" Sealed Enclosure with Built-in Amplifier

INSTALLATION INSTRUCTIONS

Filtered PWM Speed Control for Permanent Magnet DC Motors

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

WARNINGS, CAUTIONS AND NOTES

Size 15 thru 29 Mesur-Fil Fluid Couplings P

BLDC SPEED CONTROL INSTRUCTION MANUAL Low voltage Brushless DC control

Boston Gear Ratiotrol

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

END USER TERMS OF USE

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer

Water Jetter Units DU JT50 / DU JT100

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

Boston Gear Ratiotrol DC Motor Speed Control

SELECT DIAGNOSTIC GUIDE. INST028 Doc 3.02

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

SPC-PANEL Simplex, Single Phase Pump Control Panel

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

SAFTRONICS DF8 PLUS SERIES

Installation Instructions for Eaton Surge Protective

Installation Power Management Unit Battery Cables and Battery Harness

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

Transcription:

DIST. AUTORIZADO Plug-In Clutch/Brake Control with Solid State Switching P-29-5 19-0409 Service & Installation Instructions An Altra Industrial Motion Company

DIST. AUTORIZADO Brake (Red) and clutch (Green) indicator lights Potentiometer for anti-overlap adjustment When used with the Warner Octal Sockets, the control meets the appropriate UL and CuL certifications. Introduction The is a solid-state clutch/brake control designed for operation of all Warner Electric 90 volt DC clutches and brakes with the exception of the high torque series. It should not be used to directly power Warner Electric permanent magnet electrically released brakes as the units require an adjustable current or voltage supply to provide optimum release. The clutch/brake control is a direct plug-in replacement for the previous MCS-02-2 control. The difference between the two versions is that the has a potentiometer for adjustment of the anti overlap between clutch and brake where the MCS-02-2 was switch selectable for preset times only. Additionally, the fuse changed for a AG type for the MCS-02-2 to a 5mm type fuse on the. Also included in the are LED indicators indicating when the brake or clutch is energized. The clutch/brake control is designed to switch between a clutch/brake combination, two clutches or two brakes, one unit on at a time. Control design is such that on power up, the brake channel energizes initially, with normal switching inputs. The time delay feature is designed to minimize clutch/brake interaction by reducing clutch/brake torque overlap. Indicator LED s on the control show when the brake channel (RED) or clutch channel (GREEN) is energized. An internal fuse provides protection from overload conditions. Additionally the control is protected against output short circuit conditions. The control does not protect from AC ground loops or faults on the DC output side. Failure to follow these instructions may result in product damage, equipment damage, and serious or fatal injury to personnel. Specifications Power Input Output Fusing Switching Time Delay Dimensions Ambient Temperature Cycle Rate 120VAC ±10% 50/60 HZ 90 VDC full wave rectified. 0.50 amps maximum. 1/2 amp, 250V, 5 x 20mm internal. Replacement 45-001-06 Momentary contact, maintained contact, or solid state open collector logic. Minimum contact rating 20VDC resistive, 0.01 amps. Minimum input pulse 1 millisecond. Adjustable potentiometer for 0 to 10ms - both channels Approx. 4'' high x -1/2'' wide x 1-1/2'' deep. -20 to +122 F (-29 to +50 C) Consult the Application Engineering section of Warner Electric s Master Catalog, P-124, for capabilities in your application. Model Part No. 6002-44-001 Octal Socket, Foot Mounted 6001-101-001 Din Rail Mount Octal Socket 6001-101-002 The control mounts in one of the two optional octal sockets which are purchased separately. Wiring is made at the socket terminals. 2 Warner Electric 00-25-9050 P-29-5 19-0409

To avoid injury (or even death), always make certain all power is off before attempting to install this control or any electrical equipment. Do not touch the board if power is applied. Installation Mounting 1. Select a suitable location in the panel or cabinet where the will be located. Insure sufficient space is available for socket & wiring and control when plugged into the socket. 2. Mount the socket (foot mount) to the panel or attach the DIN Rail Mount to its track where it will be located. Make sure socket is properly secured.. Once socket is mounted and secured, proceed to the control wiring section. Dimensions DIST. AUTORIZADO.60" MAX Std. Octal Keyed Plug 1.5" (9.9) Clutch Anti-Overlap ADJ.0" MAX Brake Anti-Overlap Potentiometer.0" MAX 1.45" MAX Octal Socket P/N 6001-101-001 Purchased Separately 2.9" (60.).0" (1.) DIN Rail Mount Socket P/N 6001-101-002 Purchased Separately.1" (1) Wiring Hook-up The clutch/brake control is interchangeable with its predecessor, the MCS-02-2, but is not directly interchangeable with other Warner Electric plug-in controls. Before actual installation of the into its socket, insure all external wiring conforms to the following hook-ups: Power and Load Wiring 1. Connect the hot side of the 120 VAC power to terminal 1 of the socket and secure tightly. 2. Connect the neutral side of the 120 VAC power to terminal 5 of the socket and secure tightly. Note: The hot line must be connected to terminal 1. This line measures 120 VAC to conduit ground. The neutral line (color coded white or natural-gray) is grounded at the 120 VAC transformer and must be connected to terminal 5. This line measures zero VAC to conduit ground. A chassis ground should be provided as non-current conducting ground wire (color coded green). 120 VAC, ± 10% 50/60 Hz H N 1 5 CBC 02. Connect the two (2) wires from the clutch to terminal 2 and terminal 6 of the socket. Secure terminal 2 tightly. 4. Connect the two (2) wires from the brake to terminal 4 and terminal 6 of the socket. Securely tighten both terminals. This is a floating type power supply and is not referenced to AC ground. Under no cirmcumstances should any of the output wire leads be connected to earth or chassis ground as the unit will be destroyed. 6 2 4 90 V Clutch 90 V Brake 1.5" (9.9) 2.40" (61) Warner Electric 00-25-9050 P-29-5 19-0409

There are switching options that can be used with the clutch/brake control. Determine which switching option you will be using and wire the switching inputs for that option. Option 1 Momentary Push Button Switches DIST. AUTORIZADO 1. Connect the normally open start switch contacts to terminals and of the socket. Tighten terminal securely. 2. Connect the normally open stop switch contacts to terminals and of the socket. Tighten both terminals securely.. This completes the wiring of the. Double check all terminal wiring at this time Proceed to the start-up section of this manual. Option 2-2-wire Maintained Switching or START STOP Switches Normally open pushbutton. Momentarily contact closure. This completes the wiring of the. Double check all terminal wiring at this time. Proceed to the start-up section of this manual. Option - Solid State Switching NPN Open Collector Logic Solid StateSwitches NPN type open collector outputs, or NPN type transistor with both collector and emitter unterminated When using solid state switching, the emitter or output common of the switching device cannot be grounded. If the outputs are grounded, then either different switching devices must be used or an input isolation transformer on the AC input to the must be used, or the will be destroyed. 1. Connect the collector of the NPN output transistor or switching device to terminal of the socket for stop input. Tighten terminal securely. When using option 2 for switching input, the switch wiring must be such that in normal state the contacts are closed at power-up to insure brake output is energized. Switching can be either through a maintained type switch or relay contacts as shown above. 1. Connect a jumper wire from terminal to terminal of the socket. Tighten terminal securely. 2. Connect the collector of the NPN output transistor or switching device to terminal of the socket for start input. Tighten terminal securely.. Connect the emitter of the NPN output transistors or switching device common for both stop and start to terminal of the socket. Tighten terminal securely. 4. This completes the wiring of the. Double check all terminal wiring at this time. Proceed to the start-up section of this manual. 2. Connect the normally closed switch or normally closed relay contacts to terminal and terminal of the socket. Tighten both terminals securely. 4 Warner Electric 00-25-9050 P-29-5 19-0409

Start-Up DIST. AUTORIZADO The following procedure may be used to check out the socket and wiring installation prior to plugging in and powering the. This procedure will check for any grounding problem and prevent the control from being blown. To carry out this test, a digital voltmeter set to measure AC voltage with a range of 250 VAC is needed. 5. With control installed in socket, apply power to the. On power up, the brake output LED (Red) should be on, and the brake should be energized. 6. Cycle the control between clutch/brake channels and observe that the channel output lights switch between brake and clutch (Red LED to Green LED) and insure brake and clutch are energizing properly. 1. With the control still unplugged from the socket, apply the 120 VAC to the control socket. 2. Place one test lead of the meter to terminal 1 (hot side of 120 VAC input power) and with the other test lead of the meter measure to the other terminals of the socket. A zero volt reading should be observed between terminal 1 and all other terminals except terminal 5 which should measure the AC line voltage to the socket. A reading of other than (0) zero volts to any of the terminals (except 1 to 5) indicates some type of leakage or grounding condition and MUST be removed or the control will potentially be destroyed on power up.. Once test is complete, turn off AC power.. Start the machine and allow unit to cycle. Make any adjustment on anti-overlap potentiometer while machine is running. Adjust only enough to eliminate any interaction from one unit turning off and other unit turning on. Note: If time delay is set too high, a delay between one unit turning off and other unit turning on will be noticed. This could cause loss of control in machine function momentarily.. This completes the installation of the. 6 5 4 1 2 ACV Term 1-2 0V Term 1-0V Term 1-4 0V Term 1-5 (line voltage 120V) Term 1-6 0V Term 1-0V Term 1-0V Note: Voltages other than zero indicates problems. 4. After completion of ground fault checks is done and power off to the control socket, insert the into the octal socket. Note: The socket is keyed, so control will only go in one way. Warner Electric 00-25-9050 P-29-5 19-0409 5

DIST. AUTORIZADO Warranty Warner Electric LLC warrants that it will repair or replace (whichever it deems advisable) any product manufactured and sold by it which proves to be defective in material or workmanship within a period of one (1) year from the date of original purchase for consumer, commercial or industrial use. This warranty extends only to the original purchaser and is not transferable or assignable without Warner Electric LLC s prior consent. Warranty service can be obtained in the U.S.A. by returning any defective product, transportation charges prepaid, to the appropriate Warner Electric LLC factory. Additional warranty information may be obtained by writing the Customer Satisfaction Department, Warner Electric LLC, 449 Gardner Street, South Beloit, Illinois 6100, or by calling 15-9-1. A purchase receipt or other proof of original purchase will be required before warranty service is rendered. If found defective under the terms of this warranty, repair or replacement will be made, without charge, together with a refund for transportation costs. If found not to be defective, you will be notified and, with your consent, the item will be repaired or replaced and returned to you at your expense. This warranty covers normal use and does not cover damage or defect which results from alteration, accident, neglect, or improper installation, operation, or maintenance. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. Warner Electric LLC s obligation under this warranty is limited to the repair or replacement of the defective product and in no event shall Warner Electric LLC be liable for consequential, indirect, or incidental damages of any kind incurred by reason of the manufacture, sale or use of any defective product. Warner Electric LLC neither assumes nor authorizes any other person to give any other warranty or to assume any other obligation or liability on its behalf. WITH RESPECT TO CONSUMER USE OF THE PRODUCT, ANY IMPLIED WARRANTIES WHICH THE CONSUMER MAY HAVE ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL CONSUMER PURCHASE. WITH RESPECT TO COMMERCIAL AND INDUSTRIAL USES OF THE PRODUCT, THE FOREGOING WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES, WHETHER EXPRESSED OR IMPLIED BY OPERATION OF LAW OR OTHERWISE, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Changes in Dimensions and Specifications All dimensions and specifications shown in Warner Electric catalogs are subject to change without notice. Weights do not include weight of boxing for shipment. Certified prints will be furnished without charge on request to Warner Electric. Warner Electric LLC 449 Gardner Street South Beloit, IL 6100 15-9-1 Fax: 15-9-252 www.warnerelectric.com An Altra Industrial Motion Company P-29-5 19-0409 /0 Printed in USA