VIA 2 LED PENDANT DIRECT/INDIRECT W W W. L U M E N W E R X. C O M

Similar documents
LUMINAIRE ID DIRECT OPTICS INDIRECT OPTICS LIGHT SOURCE CRI DIRECT LUMEN PACKAGES. LED - high performance LED

DESCRIPTION PROJECT: Via 2 features our Asymmetrical Lens Optic for smooth, comfortable

CAVA CURVE LED PENDANT DIRECT/INDIRECT W W W. L U M E N W E R X. C O M

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. LED - high performance LED

AXLE LED PENDANT ASYMMETRIC W W W. L U M E N W E R X. C O M

VIA 4 LED PENDANT DIRECT/INDIRECT W W W. L U M E N W E R X. C O M

VIA 4 LED RECESSED W W W. L U M E N W E R X. C O M

DESCRIPTION PROJECT: Vega is an efficient architectural LED troffer with a distinctive luminous shielding that features a median textured

VIA 2 PLUS RECESSED W W W. L U M E N W E R X. C O M

AXLE LED PENDANT ASYMMETRIC W W W. L U M E N W E R X. C O M

REVO LED PENDANT DIRECT/INDIRECT W W W. L U M E N W E R X. C O M

DESCRIPTION PROJECT: Axle is an elegant and compact LED linear accent luminaire providing efficient asymmetric light distribution.

POP CORE ROUND 24 LED

AXLE LED WALL ASYMMETRIC INDIRECT W W W. L U M E N W E R X. C O M

RIM 72" RIM 24" File Name: RIM-ROUND-PENDANT-SPEC Page: 1 / 9

Project. Type. Notes. (1) D dimming (0-10V) 5% standard

PENDANT ASYMMETRIC MOUNT - DIRECT. Project. Type. Notes

WALL MOUNT - DIRECT/INDIRECT

SLIM PENDANT DIRECT. Project. Type. Notes. Ordering Guide PERFORMANCE PER LINEAR FOOT AT 3500K 1 / 8. axislighting.com. Shown with VL optic

RECESSED T-Bar & Drywall. Project. Type. Notes 23 15/16" 23 7/8" SIDE VIEW. culus Listed Type I.C.

twig SurroundLite TM WALL SEMI-INDIRECT Project Type Notes Ordering Guide PERFORMANCE PER LINEAR FOOT AT 3500K 1 / 7 axislighting.

light FULL BLEED APPLICATION SHOT RENDERING

Outputs between listed min and max are available. Consult factory for outputs outside of the listed range. Applies to both UP & DOWN.

light

PENDANT MOUNT - DIRECT

RECESSED T-Bar & Drywall. Project. Type. Notes AULED 14 SO

RECESSED T-BAR & DRYWALL. Project. Type. Notes. 0.5 StepLens. StepLens

PENDANT ASYMMETRIC MOUNT

PENDANT MOUNT - DIRECT/INDIRECT

WALL MOUNT DIRECT/INDIRECT. Project. Type. Notes

RECESSED ASYMMETRIC MOUNT. Project. Type. Notes TECHZONE TM AND LOGIX TM COMPATIBLE

Outputs between listed min and max are available. Consult factory for outputs outside of the listed range.

PENDANT MOUNT - DIRECT. Project. Type. Notes

Applies to both UP & DOWN. Outputs between listed min and max are available. Consult factory for other lumen packages

WALL MOUNT DIRECT. Project. Type. Notes

Cubic SurroundLite TM

2 1/2. Applies to both UP & DOWN. Specify quantity. Requires 8" blank See integrated controls guide for more details.

light

SURFACE MOUNTED. Project. Type. Notes. culus Listed Type I.C.

Cubic SurroundLite TM

FULL BLEED APPLICATION SHOT RENDERING

PENDANT MOUNT. Project. Type. Notes

PENDANT MOUNT - DIRECT. Project. Type. Notes

PERIMETER - RECESSED. Regressed 3" BMPRLED OPRI ( 1) 14 PRODUCT ID LINEAR OR CORNER QTY TOTAL LENGTH. 3D VIEW - Inside Corner Pattern

PERIMETER - RECESSED. Flush BBPRLED OPRI ( 1) 14 PRODUCT ID LINEAR OR CORNER QTY TOTAL LENGTH. 3D VIEW - Inside Corner Pattern

light J ANATOMY or CLEAN CANTILEVER Sleek square aluminum tube cantilever arms allow integral powerfeed to an electrical junction box.

SURFACE ASYMMETRIC MOUNT. Project. Type. Notes

SURFACE MOUNT. Project. Type. Notes

PENDANT ASYMMETRIC MOUNT - DIRECT. Project. Type. Notes

IC 4 5 YEAR RECESSED MOUNT. Project. Type. Notes 1 9/16 PERFORMANCE PER LINEAR FOOT AT 4000K CONTROL SENSORS

Project. Type. Notes. C custom UNV universal BI bi-level dimming +NL(#) night light circuit (7) O other (6) +GTD(#) generator transfer device (7)

WALL LO-OUTPUT. Project. Type. Notes

CLUSTERS PLANAR DOWNLIGHT W W W. L U M E N W E R X. C O M

CLUSTERS LINEAR DOWNLIGHT W W W. L U M E N W E R X. C O M

RECESSED T-Bar & Drywall. Project. Type. Notes 47 15/16" 47 7/8" 48" between T-Bar SIDE VIEW

SURFACE MOUNT. See page 3 for DLC Approved options

RECESSED T-Bar & Drywall. Project. Type. Notes. 3 7/8" 98mm

RECESSED - WITH StepLens OPTION. TECHZONE TM AND LOGIX TM COMPATIBLE for more info see page 4 See page 2 for DLC Approved Options

Notes: 4 3/4" 121mm. (1) Compatible with Redwood systems

WALL MOUNT - DIRECT/INDIRECT 0.25" Glo Lens 0.25"

RECESSED MOUNT. Outputs between listed min and max are available. Consult factory for outputs outside of the listed range.

Project. Type. Notes PRODUCT ID NOM.LUMENS/FT CRI COLOUR TEMP. SHIELDING LENGTH/FT FINISH VOLTAGE

Please consult factory for other lumen packages

PENDANT SEMI-DIRECT. Applies to both UP & DOWN. Consult factory for other lumen packages

SURFACE FLUSH FLUSH 5 1 / / /4 2 1 /16

REGOLO 1. RP11 Direct

SURFACE MOUNT. (2) D dimming (0-10V) 5% standard

Luminaire PROFILE-SPOKE Ind. Up Dn Control (PS3-B) Type. Project. Notes. Performance Summary OPTIONS 4S D 76 W 3S D 57 W

Finelite, Inc Whipple Road Union City, CA / Fax: 510 /

Project. Type. Notes 8' (96") 8' (96") ALL ORDERS MUST BE SUBMITTED WITH DRAWINGS INDICATING DIMENSIONS, ANGLES AND DIAMETER

CLARA CLA SUSPENDED, WALL, SURFACE

5 YEAR CONTROL SENSORS

NOVENTA NV3.5 SUSPENDED, WALL, SURFACE, RECESSED. STANDARD SIZES 3.5" Aperture corner profile Configurable in individual straight run sections

Signal White is standard finish

8' (96") 8' (96") ALL ORDERS MUST BE SUBMITTED WITH DRAWINGS INDICATING DIMENSIONS, ANGLES AND DIAMETER

Project. Type. Notes. (3) D dimming (0-10V) 5% standard

Project. Type. Notes PRODUCT ID NOM.LUMENS/FT CRI COLOUR TEMP. SHIELDING LENGTH/FT FINISH

Notes: 4 3/4" 121mm. (1) Compatible with Redwood systems. See integrated controls guide for further details

Luminaire PROFILE-SPOKE 15 UP 85 DN LED (PS1-D) Type. Notes. Performance Summary D OPTIONS 3S A 28 W B 34 W C 44 W D 57 W

Notes: 4" 102mm. (1) Compatible with Redwood systems

STUD TM 3 Linear LED luminaire- T-bar Mount

HP-4 WW-R. Finelite, Inc Whipple Road Union City, CA / Fax: 510 /

EX3. Project Name _ K. R_x_ Rectangle. MAC JB Junction Box Movable AC

RECESSED MOUNT. 2 StepLens

PRODUCT ID OPTICS LENGTH/FT LAMP LAMP CONFIGURATION FINISH VOLTAGE ARW

FINELITE 10 Year LED Warranty

PRODUCT ID NOM.LUMENS/FT CRI COLOUR TEMP. SHIELDING LENGTH/FT FINISH VOLTAGE PRLED

EX3B. Project Name _ K 4000K. R_x_ Rectangle. MAC JB Junction Box Movable AC

FINA F48B 48 Direct and Uplight Architectural Round

HP-2 WW-R. Finelite, Inc Whipple Road Union City, CA / Fax: 510 /

Linear. TruGroove recessed

Rail 4 RM4DI (Formerly Grande) LED. Pendant. Direct/Indirect

FINA F48 48 Direct and Uplight Architectural Round

Stail RMEP8 LED. Pendant

Linear. TruGroove Recessed

SURFACE - LINEAR - FLUSH

Project Name. 23-3/4 (603.3mm)

Project Name. 24 (609.6mm)

Notes: Indirect. 5 1/2" 140mm. 5 1/32 128mm

PENDANT - LINEAR WITH COMBINED DISTRIBUTIONS

Transcription:

Shown with HLO optics ORDER GUIDE Integrated track DESCRIPTION PROJECT: Elegant and flexible, the Via 2 / pendant features the option of our Widespread TYPE: Optics for smooth ceiling brightness. NOTES: Via 2 / can be configured in discrete luminaires, continuous runs, and patterns, with a wide range of lumen packages, color choices, and electrical and controls options. Via 2 / is part of the larger Via family, which includes visually coordinated recessed and mounted luminaires, as well as other light distributions, including wall Widespread Optics washing and asymmetric optics. up to 123 lm/w performance VIA2PDI HLO LED LUMINAIRE ID DIRECT OPTICS INDIRECT OPTICS LIGHT SOURCE CRI DIRECT LUMEN PACKAGES VIA2PDI - via 2" pendant HLO - High-Efficiency WIO - Widespread indirect optics LED - high performance LED 80-80CRI 350 - min. low output 350lm/ft direct/indirect Lambertian Optic CLO - Clear Lambertian Optic 90-90CRI 500 - medium output 500lm/ft 750 - max. high output 750lm/ft #### - other required lm/ft INDIRECT LUMEN PACKAGES COLOR TEMP. LUMINAIRE LENGTH VOLTAGE DRIVER 350 - min. low output 350lm/ft (for CLO only) 500 - medium output 500lm/ft 750 - max. high output 750lm/ft 1000 - max. high output 1000lm/ft (for WIO only) #### - other required lm/ft 30-3000k 35-3500k 40-4000k Standard sections - 2', 3', 4', 5', 8' & 12' For all other specify length #FT - nominal length in feet #IN - length in inches Continuous Run - for luminaires over 12' Minimum Individual section 2' 120-120V 277-277V UNV - 120V-277V 347-347V (not available with Lutron) D1-1% dimming 0-10V DA - Dali LTEA2W - Lutron 1% - 2 wires 120V LDE1 - Lutron 1% Eco Dim to Off LDE5 - Lutron 5% EcoSystem ELECTRICAL MOUNTING FINISH CONTROLS OPTIONS 1-1 circuit 2-2 circuits +#EB - emergency battery (min 8' fixture, except Lutron) +#EM - emergency light circuit +#NL - night light circuit +GTD### - generator transfer 53WAC36 - power 5" + non power 3" white canopy (36" air craft cable) 55WSW18 - power 5" + non power 5" white canopy & stem (18" stem) For all other options refer to our Pendant Mounting Guide W - matte white AL - aluminum B - matte black CF# - custom finish specify RAL# INDIVIDUAL CONTROLS OMS - Onboard Occupancy ODS - Onboard Daylight OCS - Onboard Occupancy & Daylight GROUPED CONTROLS LSC - Local system NSC - Network system FU - fuse ITR - integrated track (consult factory) TB# - T-bar caddy clip specify grid size TG# - Tegular caddy clip specify grid size ST - Screw Slots caddy clip CU - custom device, 120V or 277V See page 2 for ordering code detailed information CROSS SECTION VIA2PDI-CLO - air craft cable VIA2PDI-CLO - stem VIA2PDI-WIO - air craft cable VIA2PDI-WIO - stem File Name: VIA2-PENDANT-DIRECT-INDIRECT-SPEC Page: 1 / 10

OPTICS Widespread Optics (WIO) - The LumenWerx Widespread Optic (WIO) uses two vertically oriented LED arrays that couple light into the edges of a linear light guide. A specially designed TIR/microstructure extracts light into the desired batwing distribution. Peak intensity hits at 120º while suppressing direct uplight. Peak-tozenith intensity ratio is 2:1, outstanding for a narrow luminaire. The Widespread Optic produces noticeably smoother ceiling brightness than a typical lambertian uplight distribution, permitting generally wider spacing as well. LIGHT SOURCE - LED Custom linear array of mid-flux LED's are cartridge-mounted with quick-connect wiring to facilitate service and thermal management. Available in 3000K, 3500K and 4000K with a minimum 80 CRI and an option for 90 CRI with elevated R9 value. consistency maintained to within 3 SDCM. LEDs operated at reduced drive current to optimize efficacy and lumen maintenance. All LEDs have been tested in accordance with IESNA LM-80-08 and the results have shown L80 lumen maintenance greater than 60,000 hours. Absolute product photometry is measured and presented in accordance with IESNA LM-79, unless otherwise indicated. AT 4000K WIO High Output (4000 ) 120º Peak Angle 18"-30" Optimal distance from ceiling low output 4000K 51 1400 4000 5400 106 medium output 4000K 55 2000 4000 6000 109 high output 4000K 66.5 3000 4000 7000 105 Medium Output (3000 ) SPACE CALCULATION Room: 36'Wx36'Lx12'H Suspension: 36" Fixture spacing: 14'x18' VIA2PDI-HLO-WIO-LED-80-500-500-40-4FT Lumen Output: 500 lm/ft Lumen Output: 500 lm/ft : 108 LLF: 0.9 LPD: 0.528Watt/Sq.Ft. For Workplane: Avg Illuminance = 39.34FC Uniformity Max/Min = 2.71 Uniformity Avg/Min = 1.78 For Ceiling: Avg Illuminance = 31.05FC Uniformity Max/Min = 4.67 Uniformity Avg/Min = 2.55 High Efficiency Lambertian Optic (HLO) - Matte white side reflectors combined with High-Efficiency Lambertian Optic (HLO) shielding of diffusing 0.075" thick acrylic with up to 88% transmission and good source obscuration. Luminaire brightness is controlled by the flux-to-shielding area ratio. low output 4000K 41.5 1400 3000 4400 106 medium output 4000K 46 2000 3000 5000 109 high output 4000K 57 3000 3000 6000 105 CLO Medium Output (2000 ) low output 4000K 28 1400 2000 3400 122 medium output 4000K 33.5 2000 2000 4000 120 high output 4000K 42.5 3000 2000 5000 117 Low Output (1400 ) low output 4000K 23 1400 1400 2800 123 medium output 4000K 28.5 2000 1400 3400 120 high output 4000K 37.5 3000 1400 4400 117 File Name: VIA2-PENDANT-DIRECT-INDIRECT-SPEC Page: 2 / 10

LUMINAIRE LENGTH Via 2 is made up of standard 2, 3, 4, 5, 8 and 12 foot sections that may be joined together to create longer continuous run lengths. Exact run length must be noted in the product code. The minimum individual section available is 2 foot. All individual sections are joined together onsite using the joiner kits provided. LumenWerx offers joiner kits that are extremely simple to work with in the field and result in a fixture that appears virtually seamless with no light leak at any connection. MOUNTING OPTIONS Fixtures can be pendant-mounted, using aircraft cables, or stem-mounted. Unless otherwise specified, LumenWerx provides the following hardware: For cable-mounted fixtures - 53WAC36 (5" white canopy for all power mounting point, 3" white canopy for non power mounting point, and a 36" cable) For stem mounted fixtures - 55WSW18 (5" white canopy for all power mounting point, and non power mounting point, and a 18" white stem) Caddy clips, if required specify under OPTIONS For all other options, see our website for a detailed Pendant Mounting Guide FINISH Interior - 95%, reflective matte powder coated white paint Exterior - matte white, matte black or aluminum powder coating. Custom finishes are also available. joining system Via 2 direct/indirect CLO CONTROLS LumenWerx offers several options for integrating occupancy and daylight controls. Whether a sensors control its own fixture or is part of a group of fixtures, lights can be automatically controlled according to different energy saving strategies. With individual Controls, an on-board sensor controls the fixture in which it is installed. Depending on the length, more than one sensor may be necessary and may control the entire fixture, or just a section. With Grouped Controls, on-board or remote sensor are part of a either a local or network sensor infrastructure. It s possible to scale the controls, from a switch to a fixture setup, to a room or a whole building Occupancy and or daylight harvesting. joining system Via 2 direct/indirect Wide Spread ELECTRICAL Factory-set, adjustable output current LED driver with universal (120-277VAC) input. Dimmable from 100% to 1% with 0-10V dimming control. Rated life (90% survivorship) of 50,000 hours at 50ºC max. ambient (and 70ºC max. case) temperature. At maximum driver load: Efficiency>84%, PF>0.9, THD<20%. Other specifiable options include Lutron Hi-Lume 1% (specify 2-wire, or Ecosystem Dim-to-Off), Lutron 5-Series (5% Ecosystem), DMX (RDM compatible) and DALI protocol drivers. All of our standard 0-10V drivers are NEMA 410 compliant. EMERGENCY Factory installed long life high temperature recyclable Ni-Cad battery pack with test switch and charge indicator, minimum of 90 minutes operation, up to 1000 lumens per 4ft (25ºC) emergency lighting output. Recharge time of 24 hours. INDIVIDUAL CONTROLS Individual controls are integrated into the fixture and are therefore easy to use and allow for a cleaner looking space as no ceiling or wall-mounted sensors are required. Individual controls can be one of three types (OMS) Occupancy, (ODS) Daylight Harvesting (Photocell), or (OCS) combined occupancy and daylight harvesting. These controls will be installed with factory settings, but most offer field adjustability with regular tools or manufacturer supplied configuration tools. 2" Location of an Onboard control GROUPED CONTROLS Local systems permit added flexibility and interconnectivity. Each fixture can now become part of a group of fixtures and be controlled by On-Board or remote sensors as well as wireless switches or controllers. With this architecture, it is now possible to have fewer fixtures with On-Board sensor which control all of the fixtures of the lighting zone. In order to have grouped controls programmed in factory, it is required that a floor layout with requested grouping and functionality be supplied. Field commissioning is also possible but must be requested and discussed before final Purchase Order is placed. Network Controls, Lumenwerx fixtures are compatible with most popular BMS integration protocols such as DALI, DMX, EnOcean, BACnet, Enlighted and Lutron Ecosystem just to name a few. Field commissioning is usually required and details must be discussed before final Purchase Order is placed. File Name: VIA2-PENDANT-DIRECT-INDIRECT-SPEC Page: 3 / 10

Please contact our controls department at controls@lumenwerx.com for further assistance. OPTIONS ITR - integrated track Multiple track systems manufactured by others, are offered in Via 2, in individual, or runs, with or without LED integrated sections. Detailed specifications of the track system must be supplied. For other mounting options, please consult factory. CERTIFICATIONS ETL - Rated for Indoor Dry/Damp locations. Conforms to UL Standard 1598 and certified to CAN/CSA Standard C22.2 No. 250.0. WARRANTY LumenWerx provides a five-year limited warranty of electrical and mechanical performance of the luminaires, including the LED boards, drivers, and auxiliary electronics. LumenWerx will repair or replace defective luminaires or components at our discretion, provided they have been installed and operated in accordance with our specifications. Other limitations apply, please refer to the full warranty on our website. VIA2-ITR - air craft cable VIA2-ITR - stem CONSTRUCTION Housing - Extruded Aluminum (0.095" nominal) up to 90% Recycled Content Interior brackets - Die formed cold rolled sheet steel 18 gauge thick Joining system - Die cast Zinc (0.95" nominal) Reflectors - Extruded Aluminum (0.075 nominal) up to 95% reflective matte Light guide - Clear PMMA Laminated with microstructure film formed into optical TIR/extraction form End caps - Die cast Aluminum (0.95" nominal) Hanger - Chromed Griplock securely attached with spring steel hardware in end caps and/or joiners Air craft cable suspension - 7x7 braids Aluminum air craft cable 0.06" thick Stem - 0.5" diameter threaded steel tube matte white or aluminum powder coating. Custom finishes are also available WEIGHT Via 2 4ft - 10.68lbs - 4.85kg Via 2 8ft - 22.03lbs - 10kg Via 2 12ft - 32.60lbs - 14.8kg File Name: VIA2-PENDANT-DIRECT-INDIRECT-SPEC Page: 4 / 10

PERFORMANCE WITH INDIRECT WIO WIDESPREAD 500 LUMEN PER FOOT 1525 low output 3000K 35 1400 2000 3400 97 low output 3500K 34.5 1400 2000 3400 99 low output 4000K 33.5 1400 2000 3400 101 1525 medium output 3000K 39 2000 2000 4000 103 medium output 3500K 38 2000 2000 4000 105 medium output 4000K 37 2000 2000 4000 108 1525 high output 3000K 51 3000 2000 5000 98 high output 3500K 50 3000 2000 5000 100 high output 4000K 48 3000 2000 5000 104 File Name: VIA2-PENDANT-DIRECT-INDIRECT-SPEC Page: 5 / 10

PERFORMANCE WITH INDIRECT WIO WIDESPREAD 750 LUMEN PER FOOT 1525 low output 3000K 44 1400 3000 4400 100 low output 3500K 43 1400 3000 4400 102 low output 4000K 41.5 1400 3000 4400 106 1525 medium output 3000K 48.5 2000 3000 5000 103 medium output 3500K 47.5 2000 3000 5000 105 medium output 4000K 46 2000 3000 5000 109 1525 high output 3000K 60.5 3000 3000 6000 99 high output 3500K 59.5 3000 3000 6000 101 high output 4000K 57 3000 3000 6000 105 File Name: VIA2-PENDANT-DIRECT-INDIRECT-SPEC Page: 6 / 10

PERFORMANCE WITH INDIRECT WIO WIDESPREAD 1000 LUMEN PER FOOT 1525 low output 3000K 53.5 1400 4000 5400 101 low output 3500K 52.5 1400 4000 5400 103 low output 4000K 51 1400 4000 5400 106 1525 medium output 3000K 58.5 2000 4000 6000 103 medium output 3500K 57 2000 4000 6000 105 medium output 4000K 55 2000 4000 6000 109 1525 high output 3000K 70 3000 4000 7000 100 high output 3500K 68.5 3000 4000 7000 102 high output 4000K 66.5 3000 4000 7000 105 File Name: VIA2-PENDANT-DIRECT-INDIRECT-SPEC Page: 7 / 10

PERFORMANCE WITH INDIRECT CLO 350 LUMEN PER FOOT 143 287 430 573 low output 3000K 24 1400 1400 2800 117 low output 3500K 23.5 1400 1400 2800 119 low output 4000K 23 1400 1400 2800 123 195 390 584 779 medium output 3000K 29.5 2000 1400 3400 115 medium output 3500K 29 2000 1400 3400 117 medium output 4000K 28.5 2000 1400 3400 120 292 584 877 1169 high output 3000K 39.5 3000 1400 4400 111 high output 3500K 39 3000 1400 4400 113 high output 4000K 37.5 3000 1400 4400 117 File Name: VIA2-PENDANT-DIRECT-INDIRECT-SPEC Page: 8 / 10

PERFORMANCE WITH INDIRECT CLO 500 LUMEN PER FOOT 205 410 615 819 low output 3000K 29.5 1400 2000 3400 116 low output 3500K 29 1400 2000 3400 118 low output 4000K 28 1400 2000 3400 122 205 410 614 819 medium output 3000K 35 2000 2000 4000 115 medium output 3500K 34.5 2000 2000 4000 116 medium output 4000K 33.5 2000 2000 4000 120 292 584 877 1169 high output 3000K 45 3000 2000 5000 111 high output 3500K 44 3000 2000 5000 113 high output 4000K 42.5 3000 2000 5000 117 File Name: VIA2-PENDANT-DIRECT-INDIRECT-SPEC Page: 9 / 10

PERFORMANCE WITH INDIRECT CLO 750 LUMEN PER FOOT 307 615 922 1229 low output 3000K 38 1400 3000 4400 114 low output 3500K 38 1400 3000 4400 116 low output 4000K 36.5 1400 3000 4400 120 307 615 922 1229 medium output 3000K 44 2000 3000 5000 113 medium output 3500K 43.5 2000 3000 5000 115 medium output 4000K 42 2000 3000 5000 119 307 614 922 1229 high output 3000K 54.5 3000 3000 6000 110 high output 3500K 53.5 3000 3000 6000 112 high output 4000K 51.5 3000 3000 6000 116 File Name: VIA2-PENDANT-DIRECT-INDIRECT-SPEC Page: 10 / 10