File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

Similar documents
File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

C E R T I F I C A T E O F C O M P L I A N C E

File E31519 Project 10CA February 4, 2011 REPORT MAGNETIC MOTOR CONTROLLERS. Siemens AG Amberg, Germany

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

Certificate of Compliance

Certificate of Compliance

Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety.

E44653 SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

File E63614 Project 01SC January 10, 2002 REPORT COMPONENT - MOTOR CONTROLLERS, MAGNETIC. Fujitsu Takamisawa Component Ltd.

Certificate of Compliance

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

File E14900 Project 98NK January 11, 1999 REPORT MOTOR CONTROLLERS MAGNETIC. Siemens Energy & Automation Inc. Batavia, IL

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Selection Guide Motor Control Device Solutions

A302DN.40/.63A Thermal Current Motor Starter

Control Circuit Protection

Self-protected Combination Starters System PKZ 2-SP

File E Project 92ME February 6, 1992 REPORT COMPONENT - POWER SUPPLIES. For Use In INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Bulletin 1489 Circuit Breakers. Selection Guide

Certificate of Compliance

IN2 Enclosed Switches and Circuit Breakers

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

JDDZ.E Cartridge Fuses, Nonrenewable. Cartridge Fuses, Nonrenewable

DETAIL SPECIFICATION SHEET

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

XT IEC Power Control Manual Motor Protectors

KT4 Manual Motor Starter

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Equipment Protection. Transformers 600V or Less

L-Frame. With Standard Line and. Standard Terminals Only. Catalog Number. Price U.S. $ LDB2300 LDB2350 LDB2400 LDB2450 LDB2500 LDB2600

ECET 211 Electric Machines & Controls Lecture 8 Motor Control Circuits (1 of 2) Lecture 8 Motor Control Circuits

File E Project 02ME CORD CONNECTED CLASS 2 POWER UNITS. Globtek Inc. Northvale, NJ

3 - Protection components Motor circuit-breakers

Cutler-Hammer. January 2001

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Underwriters Laboratories Inc. Marking Guide. Molded Case Circuit Breakers. 600 Volts or Less April 2002

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

SECTION MOTOR CONTROL

ECET Circuit Design Motor Loads. Branch Circuits. Article 210

Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units

MAGNETIC MOTOR STARTERS

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product Specification Sheet #3LD2.1

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

C E R T I F I C A T E O F C O M P L I A N C E

Motor Protection. Presented By. Scott Peele PE

Ideal for use as a manual starter

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Medium Voltage Metal-Enclosed Switches

File E87247 Project 07CA July 19, 2008 REPORT UNINTERRUPTIBLE POWER SUPPLY EQUIPMENT

Cutler-Hammer. January 2001

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Design Standard. Purpose: Design Standard:

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Industry Automation Control Components

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

max pole for t=15 ms

1 Phase electronic contactor (SC 1)

AF series contactors (9 2650)

Application Techniques. North American Standards, Configurations, and Ratings: Introduction to Motor Circuit Design

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Selective Coordination

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Motor Starter Protectors

SECTION PANELBOARDS

Electronic overload relays EF205 and EF370

Certi 堵脝 cation Record

A. Submit manufacturer's literature and technical data before starting work.

Air Conditioning Disconnects Molded Case Switch

Design Standards NEMA

Motor Starter Protectors

File E Project 01ME June 15, 2001 REPORT POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT

SPEEDFAX TM 2011 Disconnect Switches Contents

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

Cutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001

Cutler-Hammer. Molded Case Circuit Breakers Amperes. Product Selection January 2001 Vol. 1, Ref. No ) J-Frame

AP/UP, AP/MIL Series Magnetic Circuit Protectors

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

BETA Switching Switches and Light Indicators

Molded Case Circuit Breakers Amperes LSIA. LSIG Catalog Number 3-Pole Standard Interrupting Capacity 600V AC Rated V AC 13,950.

Thermal Overload Relays - WEG RW Series, 2 Pole

KT4 Manual Motor Starters

Transcription:

File E47705 Project 97ME18400 August 21, 1997 REPORT on MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany Copyright 1997 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above named company to reproduce this Report provided it is reproduced in its entirety.

File E47705 Vol. 7 Sec. 7 Page 1 Issued: 1997-08-21 and Report Revised: 2005-08-16 DESCRIPTION PRODUCT COVERED: USL, CNL - Type No. 3RV1031, 3RV1131, 3RV1331, 3RV1431 or 3RV1631, followed by combination of 0, 1 or 4 and a letter A through K, followed by A, B, C or K followed by 1 or 3. May be followed by additional numbers and letters for manufacturer s use. GENERAL: The devices 3RV1031 are open type 3-pole manual motor controllers for starting and stopping motors which may be connected directly across the line. They are adjusted over a small range as indicated in the setting range table. They are provided with integral ambient compensated, non replaceable thermal trip features and are suitable for providing overload protection and motor disconnect. The trip current is 125 percent of the FLA shown on dial. Type 3RV1131-..is identical to the standard series device but with no motor overload function. The internal overload tripping system does not trip the controller, however it trips the attached trip module for indication to remote panels. The devices 3RV1331 are identical to the Types 3RV1031 except the thermal overload trip is out of function. The devices 3RV1431 are identical to the Types 3RV1031 except the instantaneous overcurrent trip is adjusted to 19 x I e. The devices 3RV1631 are identical to the Types 3RV1031 except the thermal overload trip is adjusted to Class 5. These devices may be provided with certified accessories of Type 3RVl9.. including auxiliary switches, tripping units and short circuit indicators. RATINGS: General Purpose Rating 600 V AC, 50 A, FLA max. 54 A Horsepower Voltage 1-ph 3-ph 115 V 3 hp - 200/208 V 7 ½ hp 15 hp 230/240 V 10 hp 20 hp 460/480 V - 40 hp 575/600 V - 50 hp Pilot Duty rating for 3RV1131 trip module outputs 1 NO + 1 NC: C600, R300 opposite polarity.

File E47705 Vol. 7 Sec. 7 Page 2 Issued: 1997-08-21 and Report Revised: 2005-05-12 ENGINEERING CONSIDERATIONS (NOT FOR UL REPRESENTATIVE USE): CNL - Indicates Investigated to Canadian National Standard(s) C22.2 No. 14-M95. Note: CNL = Canadian National Standards - Listed. USL = United States Standards - Listed. These devices are suitable for use on a circuit capable of delivering not more than 1,000 rms symmetrical amperes up to setting range - 1B, 600 V maximum and with - 1C and higher 5,000 rms symmetrical amperes, 600 V maximum. High Capacity Short-circuit rating: 480 V, 3 phase, 65,000 rms symmetrical amperes 600 V, 3 phase, 30,000 rms symmetrical amperes Enclosure size: 11-1/2 by 11-1/2 by 6 inches, metal Suitable for tap conductor protection in group applications Type 3RV1031 only These devices are suitable for use as motor disconnect. These devices are suitable to provide over current protection for control transformers. NOMENCLATURE BREAKDOWN I. Basic Type Size S2 3RV1031-1A A 1 8-1B P0 I II III IV V VI VII 3RV1031 - with overload (Class 10 or Class 20) and short-circuit protection (12 x I e ) 3RV1331 - with short-circuit protection only (12 x I ) e 3RV1131 3 main contacts with short-circuit protection, overload tripping 12 x I e is indicated by an attached tripping module. 3RV1431 - with overload and short-circuit protection (19 x I ) e 3RV1631 - with overload (Class 5) and short-circuit protection (12 x J e )

File E47705 Vol. 7 Sec. 7 Page 3 Issued: 1997-08-21 and Report Revised: 2005-05-12 II. Setting Ranges Suffix From To (A) Max. Fuse or CB 0K 0.9 1.25 6 A 1A 1.1 1.6 6 A 1B 1.4 2 6 A 1C 1.8 2.5 10 A 1D 2.2 3.2 10 A 1E 2.8 4 15 A 1F 3.5 5 20 A 1G 4.5 6.3 25 A 1H 5.5 8 30 A 1J 7 10 40 A 1K 9 12.5 50 A 4A 11 16 60 A 4B 14 20 80 A 4D 18 25 100 A 4E 22 32 125 A 4F 28 40 150 A 4G 36 45 175 A 4H 40 50 200 A 4D 18 25 100 A III. Tripping Class A setting ranges with instantaneous tripping, Class 10 B setting ranges with instantaneous tripping, Class 20 C same as A but fixed to maximum range value K setting ranges with instantaneous tripping, Class 5 IV. Type of Terminals 1 Screw Terminal 3 Main terminal have screw terminals auxiliary contact cage clamp terminals, if provided V. Auxiliary Switches and Tripping Units (Combinations with certified accessories Type 3RV19...) 0 without 1 1NO + 1NC, side mounted 2 2NO, side mounted 3 2NC, side mounted 4 1 changeover contact, top mounted 5 1NO + 1NC, top mounted 8 code No. for further following suffixes under V.

File E47705 Vol. 7 Sec. 7 Page 4 Issued: 8-21-97 and Report VI. Auxiliary Switches and Tripping Units continued -1B Undervoltage trip, side mounted -2B same as -1B + 2NO make-before-break -3B Remote tripping unit, side mounted VII. Operating voltage for accessories 24 V through 600 V ac or 12 V through 250 V dc

File E47705 Vol. 7 Sec. 7 Page 5 Issued: 1997-08-21 and Report Revised: 2005-05-12 CONSTRUCTION DETAILS General: The product shall be constructed in accordance with the following description and photos. Spacings: Other than noted below, the spacings between bare live parts of opposite polarity and between bare live parts and grounded metal parts is not less than 3/8 in (9.5 mm) measured through air or 1/2 in (12.7 mm) measured over the surface of insulating material. The spacings between bare live parts and metal parts of an enclosure or the mounting surface shall be not less than 1/2 in (12.7 mm) through air or over surface. Tolerances: Unless specified otherwise, the indicated dimensions are nominal. Corrosion Protection: All parts are of corrosion resistant material or are plated or painted as corrosion protection. Markings: Paper adhesive labels on the device and printed to the cover including the manufacturer s name, type and electrical ratings. The terminal tightening torque must be marked on the device. These markings do not pertain to control circuits. The following statement is also marked on the device: MAX. FUSE / CB xx A xx = for current rating of the fuse see list on page 2. The following statement is also marked on the device or in the instruction manual: SUITABLE FOR USE ON A CIRCUIT CAPABLE OF DELIVERING NOT MORE THAN xxxx RMS SYMMETRICAL AMPERES; 600 V MAXIMUM. xxxx = 1,000 up to setting range 1A 5,000 from setting range 1B USE 75 C COPPER WIRE ONLY Type 3RV1031 marked Suitable for tap conductor protection in group applications SUITABLE AS MOTOR DISCONNECT

File E47705 Vol. 7 Sec. 7 *Page 5A Issued: 1997-08-21 and Report New: 2003-06-05 GROUP INSTALLATION: (For reference only, in accordance with UL 508, 16th Edition). All setting ranges are suitable for use in group installation for the following ratings: *Maximum Short-circuit rating: 480 V, 3 phase, 65,000 rms symmetrical amperes. 600 V, 3 phase, 30,000 rms symmetrical amperes. Enclosure size: 11-1/2 by 11-1/2 by 6 inches, metal. Branch Circuit Protective device: The appropriate BCPD needs to be determined in accordance with the National Electrical Code, NFPA-70 Article 430-53 and the application. The following devices are permitted. Fuses: Circuit breakers: Classes RK1, RK5, J, G, T, CC Listed Siemens type, with a marked short-circuit rating equal or larger than the available short circuit current rating. These devices were tested for group installation use at the above levels without any upstream branch circuit device.