Documents and Addresses

Similar documents
Prüffeld der Schaltwerke

Prüffeld der Schaltwerke

Report No.: MS/E Copy No.: 0 Contents: 140 sheets

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Rated voltage 12 kv to 38.5 kv Rated current 630 A to 2500 A

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

Outdoor vacuum breaker for railway applications - FSK II

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

3TM Vacuum Contactors

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

HMI, APRIL, Test Laboratories in Ratingen

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring

The vacuum circuit breaker for commercial buildings, industrial plants and utilities

INTERNATIONAL STANDARD

DISTRIBUTION SOLUTIONS HA Breaker Retrofit. Medium Voltage Service Marketing and Sales

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Air-insulated switchgear UniGear type ZS1

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

HD4. Gas insulated MV circuit-breakers kv A ka

Independent Testing Laboratory for High Voltage Equipment

Siemens AG Catalog HG11.07 Edition 10/ AE6 Medium-Voltage Equipment. siemens.com/sion

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH

Vacuum Generator Circuit Breaker - A trend-setting power plant technology

Vacuum Circuit Breaker VS1

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Intertek Level 4 RTL (ASTA Recognized Laboratory Scheme)

Retrofit for gas-insulated high voltage switchgear (GIS) - 8D1 and 8D2

Item 1: Contents of the complete training & CV of the lecturer

VD4 Installation and service instructions kv A ka

HB3 Generator Circuit-Breaker Switchgear

Gas-Insulated Switchgear. Type 8VN1 blue GIS up to 145 kv, 40 ka, 3150 A

HB3-80 Generator Circuit-Breaker Switchgear. Medium-Voltage Switchgear. Totally Integrated Power HB3-80. Catalog HB3-80.

FUSES. Safety through quality

Medium voltage fuses - European Fuses

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Pankaj Khali, ABB India Limited Representing :ABB Switzerland limited, September 2016 Generator Circuit-Breakers. Technical Seminar: PLN

Epoxy Technology Embedded Poles

The comprehensive portfolio of the testing laboratories at Schaltwerk Berlin siemens.com/energy/psw

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

The 3AH Vacuum Circuit-Breakers Versatile, High-Performing, Economical

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

Gas Insulated Switchgear

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

HIGS Highly Integrated Generator Circuit-Breaker Switchgear

6545(Print), ISSN (Online) Volume 4, Issue 2, March April (2013), IAEME & TECHNOLOGY (IJEET)

3AP1 DTC for 145 and 245 kv

3AH37 and 3AH38 vacuum generator circuit-breakers for power stations and industry

Publication No.: PSG

B kv T&D GAS INSULATED SWITCHGEAR

023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA

SERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

TECHNICAL SPECIFICATIONS

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

Metal Clad Switchgears

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

B4 Load Break Switches

HVX Series. 36 kv Medium Voltage Vacuum circuit breaker. Make the most of your energy SM. Medium Voltage Distribution Catalogue 2015

VB1-D Generator Circuit-Breaker Switchgear

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

CPG.0 Single busbar gas-insulated cubicles

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

ZX2 Gas-insulated medium voltage switchgear

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI

Ultra Fast Earthing Switch UFES retrofit Overview

B kv Gas-insulated Substations

36kV Gas Insulated Medium Voltage Switchgear

Contactor V-Contact VSC/P

Vacuum Circuit-Breaker Modules

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

Vmax Medium voltage vacuum circuit-breakers. IEC: kv; A; ka ANSI: kv; A; ka

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

PEHLA Testing Station Ratingen ABB Medium Voltage Laboratories

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

Technical Data Accessories MCBs Ex9B.

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

OHB Outdoor sulphur Hexafluoride circuit-breaker

Extract of the technical catalogue SACE Tmax XT New low voltage molded-case circuit breakers up to 250A

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Vacuum Circuit Breaker

شركة كهرباء محافظة القدس المساهمة المحدودة

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Horizontal Circuit Switchers

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

VEIKI-VNL Electric Large Laboratories Ltd. H-1158-Budapest, Vasgolyó utca 2-4. HUNGARY

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

UniGear type ZS1. Medium voltage, arc-proof, air-insulated, metal-clad switchboard

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

User manual W-VACi. W-VACi 12 / 17.5 / 24 kv IEC Vacuum Circuit Breakers

Exceeding the standards with MNS

Gas Insulated Metal-clad Switchgear, HMGS!

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

Metal Clad Air Insulated Switchgear

The Deutsche Akkreditierungsstelle GmbH attests that the testing laboratory

TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK

High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

Transcription:

Report No.: 05-035-MS/E Sheet: 2 Documents and Addresses Accreditation The Prüffeld der Schaltwerke, Berlin has been approved by the DATech (German accreditation body for technology) according to EN ISO/IEC 17025 for tests in the field of high-voltage switchgear and controlgear and power engineering equipment (Registration-No. DAT-P-017/92-02). Under reference to EN ISO/IEC 17025 the Prüffeld der Schaltwerke states the following: - The accreditation of the Prüffeld der Schaltwerke or any of its test reports by themselves in no way constitute or imply product approval by DATech or any other body. - If someone refers to a test in an accredited Prüffeld der Schaltwerke this reference shall include the accreditation body, i.e. DATech, the relevant scope of the accreditation and the appropriate registration number. DAR-Documents A Certificate is issued for type tests which have successfully been carried out in full compliance with the relevant specifications or standards valid at the time of the test. For these tests the equipment under test must be clearly identified by technical description, drawings and additional specifications. A Test Document is issued for parts of type tests which have successfully been carried out in full compliance with the relevant specifications or standards valid at the time of test. For these tests the equipment under test must be clearly identified by technical description, drawings and additional specifications. A Test Report is issued for all other tests which have been carried out according to specifications, standards and/or clients instructions. Similarly, this test report contains all test results, details of the conditions under which the tests were carried out, also details relating to the behaviour of the equipment during test, and its condition after the tests. Addresses: Testing Station: Prüffeld der Schaltwerke, Berlin PTD M C R&D TD Manufacturer: Client: PTD M C PB1 PTD M C R&D 18PE0402

Report No.: 05-035-MS/E Sheet: 5 Technical Data of Test Object Circuit-Breaker Test object: Three pole vacuum circuit-breaker Designation: 3AE1105-2 with vacuum interrupters VS17005 Manufacturer:, PTD M C PB1, Serial No.: 3AE/00000084 Year of manufacture: 2005 Drawing No.: Drawings and part lists - see sheet 6 Ratings assigned by the manufacturer: Rated voltage 12 kv Rated normal current 1250 A Rated frequency 50/60 Hz Rated lightning impulse withstand voltage 75 kv Rated switching impulse withstand voltage - kv Rated power-frequency withstand voltage 28 kv Rated peak withstand current Rated short-time withstand current Rated duration of short-circuit 3 s Rated short-circuit breaking current DC component of the rated short-circuit breaking current 36 % Rated short-circuit making current Rated transient recovery voltage 20.6 kv Rate of rise of transient recovery voltage 0.34 kv/µs First-pole-to-clear factor 1.5 Rated operating sequence O - 0.3 s - CO - 3 min - CO Arc extinguishing medium Vacuum Rated filling pressure for operation < 0.01 Pa Minimum functional pressure for operation - MPa abs. at 20 C Insulating medium Air Rated filling pressure for insulation - MPa abs. at 20 C Minimum functional pressure for insulation - MPa abs. at 20 C Driving mechanism (type) Spring, charged by motor Number of poles 3 Number of units per pole 1 Rated opening time < 65 ms Rated closing time < 75 ms Rated supply voltage of opening device 110 V d.c. Rated supply voltage of closing device 110 V d.c. Rated supply voltage of auxiliary circuits - V Rated frequency of supply voltage - Hz Rated line / cable-charging breaking current -/25 A Rated single capacitor bank breaking current 400 A Classification of Circuit-breaker Class M2, E2, C2 Further data: Serial number of Tube in pole L1 164356 Serial number of Tube in pole L2 164368 Serial number of Tube in pole L3 164247 Essential characteristics: - 16PE0402

Report No.: 05-041-MS/E Sheet: 2 Documents and Addresses Accreditation The Prüffeld der Schaltwerke, Berlin has been approved by the DATech (German accreditation body for technology) according to EN ISO/IEC 17025 for tests in the field of high-voltage switchgear and controlgear and power engineering equipment (Registration-No. DAT-P-017/92-02). Under reference to EN ISO/IEC 17025 the Prüffeld der Schaltwerke states the following: - The accreditation of the Prüffeld der Schaltwerke or any of its test reports by themselves in no way constitute or imply product approval by DATech or any other body. - If someone refers to a test in an accredited Prüffeld der Schaltwerke this reference shall include the accreditation body, i.e. DATech, the relevant scope of the accreditation and the appropriate registration number. DAR-Documents A Certificate is issued for type tests which have successfully been carried out in full compliance with the relevant specifications or standards valid at the time of the test. For these tests the equipment under test must be clearly identified by technical description, drawings and additional specifications. A Test Document is issued for parts of type tests which have successfully been carried out in full compliance with the relevant specifications or standards valid at the time of test. For these tests the equipment under test must be clearly identified by technical description, drawings and additional specifications. A Test Report is issued for all other tests which have been carried out according to specifications, standards and/or clients instructions. Similarly, this test report contains all test results, details of the conditions under which the tests were carried out, also details relating to the behaviour of the equipment during test, and its condition after the tests. Addresses: Testing Station: Prüffeld der Schaltwerke, Berlin PTD M C R&D TD Manufacturer: Client: PTD M C PB1 PTD M C R&D2 02PE0402 18PE0402

Report No.: 05-041-MS/E Sheet: 5 Technical Data of Test Object Circuit-Breaker Test object: Three pole vacuum circuit-breaker Designation: 3AE1105-2 with vacuum interrupters VS17005 Manufacturer:, PTD M C PB1, Serial No.: 3AE/00000084 Year of manufacture: 2005 Drawing No.: Drawings and part lists - see sheet 6 Ratings assigned by the manufacturer: Rated voltage 12 kv Rated normal current 1250 A Rated frequency 50/60 Hz Rated lightning impulse withstand voltage 75 kv Rated switching impulse withstand voltage - kv Rated power-frequency withstand voltage 28 kv Rated peak withstand current Rated short-time withstand current Rated duration of short-circuit 3 s Rated short-circuit breaking current DC component of the rated short-circuit breaking current 36 % Rated short-circuit making current Rated transient recovery voltage 20.6 kv Rate of rise of transient recovery voltage 0.34 kv/µs First-pole-to-clear factor 1.5 Rated operating sequence O - 0.3 s - CO - 3 min - CO Arc extinguishing medium Vacuum Rated filling pressure for operation < 0.01 Pa Minimum functional pressure for operation - MPa abs. at 20 C Insulating medium Air Rated filling pressure for insulation - MPa abs. at 20 C Minimum functional pressure for insulation - MPa abs. at 20 C Driving mechanism (type) Spring, charged by motor Number of poles 3 Number of units per pole 1 Rated opening time < 65 ms Rated closing time < 75 ms Rated supply voltage of opening device 110 V d.c. Rated supply voltage of closing device 110 V d.c. Rated supply voltage of auxiliary circuits - V Rated frequency of supply voltage - Hz Rated line / cable-charging breaking current -/25 A Rated single capacitor bank breaking current 400 A Classification of Circuit-breaker Class M2, E2, C2 Further data: Serial number of Tube in pole L1 164247 Serial number of Tube in pole L2 164368 Serial number of Tube in pole L3 164356 Essential characteristics: - 16PE0402

Report No.: 06-055-MS/E Sheet: 2 Documents and Addresses Accreditation The Prüffeld der Schaltwerke, Berlin has been approved by the DATech (German accreditation body for technology) according to EN ISO/IEC 17025 for tests in the field of high-voltage switchgear and controlgear and power engineering equipment (Registration-No. DAT-P-017/92-02). Under reference to EN ISO/IEC 17025 the Prüffeld der Schaltwerke states the following: - The accreditation of the Prüffeld der Schaltwerke or any of its test reports by themselves in no way constitute or imply product approval by DATech or any other body. - If someone refers to a test in an accredited Prüffeld der Schaltwerke this reference shall include the accreditation body, i.e. DATech, the relevant scope of the accreditation and the appropriate registration number. DAR-Documents A Certificate is issued for type tests which have successfully been carried out in full compliance with the relevant specifications or standards valid at the time of the test. For these tests the equipment under test must be clearly identified by technical description, drawings and additional specifications. A Test Document is issued for parts of type tests which have successfully been carried out in full compliance with the relevant specifications or standards valid at the time of test. For these tests the equipment under test must be clearly identified by technical description, drawings and additional specifications. A Test Report is issued for all other tests which have been carried out according to specifications, standards and/or clients instructions. Similarly, this test report contains all test results, details of the conditions under which the tests were carried out, also details relating to the behaviour of the equipment during test, and its condition after the tests. Addresses: Testing Station: Prüffeld der Schaltwerke, Berlin PTD M C R&D TD Manufacturer of circuit-breaker: Client: PTD M C PB1 PTD M C R&D 02PE0402

Report No.: 06-055-MS/E Sheet: 5 Technical Data of Test Object Circuit-Breaker Test object: Three pole vacuum circuit-breaker Designation: 3AE1105-2 with vacuum interrupters VS17005 Manufacturer:, PTD M C PB1, Serial No.: 3AE/00000084 Year of manufacture: 2005 Drawing No.: Drawings and part lists - see sheet 6 Ratings assigned by the manufacturer: Rated voltage 12 kv Rated normal current 1250 A Rated frequency 50/60 Hz Rated lightning impulse withstand voltage 75 kv Rated switching impulse withstand voltage - kv Rated power-frequency withstand voltage 28 kv Rated peak withstand current Rated short-time withstand current Rated duration of short-circuit 3 s Rated short-circuit breaking current DC component of the rated short-circuit breaking current 36 % Rated short-circuit making current Rated transient recovery voltage 20.6 kv Rate of rise of transient recovery voltage 0.34 kv/µs First-pole-to-clear factor 1.5 Rated operating sequence O - 0.3 s - CO - 3 min - CO Arc extinguishing medium Vacuum Rated filling pressure for operation < 0.01 Pa Minimum functional pressure for operation - MPa abs. at 20 C Insulating medium Air Rated filling pressure for insulation - MPa abs. at 20 C Minimum functional pressure for insulation - MPa abs. at 20 C Driving mechanism (type) Spring, charged by motor Number of poles 3 Number of units per pole 1 Rated opening time < 65 ms Rated closing time < 75 ms Rated supply voltage of opening device 110 V d.c. Rated supply voltage of closing device 110 V d.c. Rated supply voltage of auxiliary circuits - V Rated frequency of supply voltage - Hz Rated line / cable-charging breaking current -/25 A Rated single capacitor bank breaking current 400 A Classification of Circuit-breaker Class M2, E2, C2 Further data: Serial number of Tube in pole L1 164356 Serial number of Tube in pole L2 164368 Serial number of Tube in pole L3 164247 Essential characteristics: - 16PE0402