BCI164D - Technical Data Sheet

Similar documents
BCI164B - Technical Data Sheet

BCI164C - Technical Data Sheet Winding 06

BCI164A - Technical Data Sheet

BCI184J - Technical Data Sheet

BCI184H - Technical Data Sheet

UCDI224F - Technical Data Sheet

UCDI274J - Technical Data Sheet

UCI274H - Technical Data Sheet

UCI224C - Technical Data Sheet

UCI274H - Technical Data Sheet Winding 06

UCI274C - Technical Data Sheet Winding 06

HCI 534C/544C - Technical Data Sheet

UCI274D - Technical Data Sheet

UCDI274K - Technical Data Sheet

UCI274D - Technical Data Sheet

UCI274G - Technical Data Sheet

HCI 434E/444E - Technical Data Sheet

HCI 434D/444D - Technical Data Sheet

HCI 534F/544F - Technical Data Sheet

UCI224F - Technical Data Sheet

UCDI274K - Technical Data Sheet

UCI224E - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT

PI144D - Technical Data Sheet

PI144J - Technical Data Sheet

UCI224F - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT

HCI 434E/444E - Technical Data Sheet

HCI 534E/544E - Technical Data Sheet

HCI634G - Technical Data Sheet

UCI224F - Winding 25. Technical Data Sheet APPROVED DOCUMENT

HCI 534E/544E - Technical Data Sheet

UCDI224E - Technical Data Sheet

HCI 434F/444F - Technical Data Sheet

HCI434E/444E - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

HCI534F/544F - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

HCI434C/444C - Winding 17 APPROVED DOCUMENT. Technical Data Sheet

UCI224E - Winding 06. Technical Data Sheet APPROVED DOCUMENT

UCI274E - Winding 06 APPROVED DOCUMENT. Technical Data Sheet

UCI274E - Winding 14 APPROVED DOCUMENT. Technical Data Sheet

UCI224C - Winding 06. Technical Data Sheet APPROVED DOCUMENT

PI044D - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI144G - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI044H - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI044F - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI044E - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI144E - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI144F - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

UCI224G - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCI224F - Winding 14. Technical Data Sheet APPROVED DOCUMENT

UCI274D - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

HCI634H - Technical Data Sheet

UCI224E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCI224C - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCI224D - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

UCDI274J - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI144D - Winding 17. Technical Data Sheet APPROVED DOCUMENT

PI044D - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI044G - Winding 06 APPROVED DOCUMENT. Technical Data Sheet

PI144J - Winding 05 APPROVED DOCUMENT. Technical Data Sheet

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI044F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI144J - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

HCI 534E/544E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

HCI 534C/544C - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

LVI634E - Technical Data Sheet

HCM634K - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet

HCI634J - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet

HCI634H - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet

HCI634J - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet

HCI634H - Winding 311 and 312. Technical Data Sheet

UCM274C - Technical Data Sheet

UCM274H - Technical Data Sheet

UCM274E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCM274C - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI734G - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI736F - Winding 312. Technical Data Sheet

UCM274E - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT

UCM224D - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT

HCM534F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

HCM434E - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT

HCM534D - Winding 14 APPROVED DOCUMENT. Technical Data Sheet

HCI634V - Technical Data Sheet

PM734E - Winding 28. Technical Data Sheet APPROVED DOCUMENT

P734H - Technical Data Sheet

S5L1D-G4 Wdg Technical Data Sheet

QSK23-G3. Description. Features rpm (50 Hz Ratings) 1800 rpm (60 Hz Ratings)

QSL9-G5. Description. Features rpm (50 Hz Ratings) 1800 rpm (60 Hz Ratings)

6BTA5.9-G5. Description. Features rpm (50 Hz Ratings)

S3.8 G6 CoolPac. Description. Features rpm (50 Hz Ratings)

This engine has been built to comply with CE certification.

Features. Cylinder Block - Alloy cast iron with removable wet liners.

This engine has been built to co mply with CE certification. Gross Engine Output Net Engine Output Typical Generator Set Output

KTA38-G5. Features. Description rpm (50 Hz Ratings)

KTA50-G8. Specification sheet. Features. Description. Codes and standards rpm (50 Hz Ratings)

TAD1641GE VOLVO PENTA GENSET ENGINE

KTA50-G3. Description. Features rpm (50 Hz Ratings) 1800 rpm (60 Hz Ratings)

Perkins. Perkins. Dimensiones (Largo x Ancho x Alto)cm Peso Aprox. humedo kg. 202x76x x68x

Perkins. Perkins. Perkins. 175x68x Dimensiones (Largo x Ancho x Alto)cm Peso Aprox. humedo kg.

TAD1344GE VOLVO PENTA GENSET ENGINE

موتور ديزل : Cummins. ژنراتور : Stamford. Standby. Prime KVA KW KVA KW ديزل ژنراتور 1

Low Voltage Alternators - 4 pole LSA 44.3

Transcription:

BCI164D - Technical Data Sheet

BCI164D SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE 0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359. Other standards and certifications can be considered on request. VOLTAGE REGULATORS SX460 AVR - STANDARD With this self excited control system the main stator supplies power via the Automatic Voltage Regulator (AVR) to the exciter stator. The high efficiency semiconductors of the AVR ensure positive build-up from initial low levels of residual voltage. The exciter rotor output is fed to the main rotor through a three phase full wave bridge rectifier. This rectifier is protected by a surge suppressor against surges caused, for example, by short circuit. AS440 AVR With this self-excited system the main stator provides power via the AVR to the exciter stator. The high efficiency semi-conductors of the AVR ensure positive build-up from initial low levels of residual voltage. The exciter rotor output is fed to the main rotor through a three-phase full-wave bridge rectifier. The rectifier is protected by a surge suppressor against surges caused, for example, by short circuit or out-of-phase paralleling. The AS440 will support a range of electronic accessories, including a 'droop' Current Transformer (CT) to permit parallel operation with other ac generators. WINDINGS & ELECTRICAL PERFORMANCE All generator stators are wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 15th ) harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches, when in parallel with the mains. A fully connected damper winding reduces oscillations during paralleling. This winding, with the 2/3 pitch and carefully selected pole and tooth designs, ensures very low waveform distortion. TERMINALS & TERMINAL BOX Standard generators are 3-phase reconnectable with 12 ends brought out to the terminals, which are mounted on a cover at the non-drive end of the generator. A sheet steel terminal box contains the AVR and provides ample space for the customers' wiring and gland arrangements. It has removable panels for easy access. SHAFT & KEYS All generator rotors are dynamically balanced to better than BS6861:Part 1 Grade 2.5 for minimum vibration in operation. Two bearing generators are balanced with a half key. INSULATION/IMPREGNATION The insulation system is class 'H'. All wound components are impregnated with materials and processes designed specifically to provide the high build required for static windings and the high mechanical strength required for rotating components. QUALITY ASSURANCE Generators are manufactured using production procedures having a quality assurance level to BS EN ISO 9001. The stated voltage regulation may not be maintained in the presence of certain radio transmitted signals. Any change in performance will fall within the limits of Criteria 'B' of EN 61000-6-2:2001. At no time will the steady-state voltage regulation exceed 2%. NB Continuous development of our products entitles us to change specification details without notice, therefore they must not be regarded as binding. Front cover drawing typical of product range. 2

BCI164D WINDING 311 CONTROL SYSTEM A.V.R. VOLTAGE REGULATION SUSTAINED SHORT CIRCUIT INSULATION SYSTEM PROTECTION RATED POWER FACTOR STATOR WINDING WINDING PITCH WINDING LEADS STATOR WDG. RESISTANCE ROTOR WDG. RESISTANCE EXCITER STATOR RESISTANCE EXCITER ROTOR RESISTANCE R.F.I. SUPPRESSION WAVEFORM DISTORTION MAXIMUM OVERSPEED BEARING DRIVE END BEARING NON-DRIVE END WEIGHT COMP. GENERATOR WEIGHT WOUND STATOR WEIGHT WOUND ROTOR WR² INERTIA SHIPPING WEIGHTS in a crate SELF EXCITED STANDARD SX460 OPTIONAL AS440 ± 1.0 % ± 1.0 % SELF EXCITED MACHINES DO NOT SUSTAIN A SHORT CIRCUIT CURRENT CLASS H IP23 0.8 DOUBLE LAYER CONCENTRIC TWO THIRDS 12 0.645 Ohms PER PHASE AT 22 C SERIES STAR CONNECTED 0.56 Ohms at 22 C 19 Ohms at 22 C 0.134 Ohms PER PHASE AT 22 C BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0% 2250 Rev/Min BALL. 6309-2RS. (ISO) BALL. 6306-2RS. (ISO) 1 BEARING 2 BEARING 109 kg 112 kg 34.5 kg 34.5 kg 33.72 kg 34.5 kg 0.1278 kgm 2 0.1279 kgm 2 116 kg 122 kg PACKING CRATE SIZE TELEPHONE INTERFERENCE 64 x 54 x 72 (cm) 50 THF<2% 64 x 54 x 72 (cm) 60 TIF<50 COOLING AIR 0.071 m³/sec 150 cfm 0.09 m³/sec 191 cfm VOLTAGE SERIES STAR 380/220 400/231 415/240 440/254 416/240 440/254 460/266 480/277 VOLTAGE PARALLEL STAR 190/110 200/115 208/120 220/127 208/120 220/127 230/133 240/138 VOLTAGE SERIES DELTA 220/110 230/115 240/120 254/127 240/120 254/127 266/133 277/138 kva BASE RATING FOR REACTANCE VALUES 16 16 16 13.5 18.9 20 20 20 Xd DIR. AXIS SYNCHRONOUS 1.921 1.734 1.611 1.698 2.272 2.149 1.966 1.806 X'd DIR. AXIS TRANSIENT 0.196 0.177 0.164 0.173 0.231 0.219 0.200 0.184 X''d DIR. AXIS SUBTRANSIENT 0.123 0.111 0.103 0.109 0.146 0.138 0.126 0.116 Xq QUAD. AXIS REACTANCE 0.954 0.861 0.800 0.844 1.129 1.068 0.977 0.897 X''q QUAD. AXIS SUBTRANSIENT 0.220 0.199 0.185 0.194 0.260 0.246 0.225 0.207 XL LEAKAGE REACTANCE 0.078 0.070 0.065 0.068 0.092 0.087 0.079 0.073 X2 NEGATIVE SEQUENCE 0.184 0.166 0.154 0.162 0.218 0.206 0.188 0.173 X0 ZERO SEQUENCE 0.083 0.075 0.070 0.073 0.098 0.093 0.085 0.078 REACTANCES ARE SATURATED VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED T'd TRANSIENT TIME CONST. T''d SUB-TRANSTIME CONST. T'do O.C. FIELD TIME CONST. Ta ARMATURE TIME CONST. SHORT CIRCUIT RATIO 0.018 s 0.0045 s 0.35 s 0.0055 s 1/Xd 3

50 BCI164D Winding 311 THREE PHASE EFFICIENCY CURVES 4

60 BCI164D Winding 311 THREE PHASE EFFICIENCY CURVES 5

30 50 BCI164D Winding 311 Locked Rotor Motor Starting Curve 346V 380V 400V 415V 440V 25 PER CENT TRANSIENT VOLTAGE DIP 20 15 10 5 0 0 5 10 15 20 25 30 35 LOCKED ROTOR kva 30 60 380V 416V 440V 460V 480V 25 PER CENT TRANSIENT VOLTAGE DIP 20 15 10 5 0 0 5 10 15 20 25 30 35 40 45 LOCKED ROTOR kva 6

BCI164D Page left blank intentionally 7

BCI164D Winding 311 / 0.8 Power Factor RATINGS Class - Temp Rise Cont. F - 105/40 C Cont. H - 125/40 C Standby - 150/40 C Standby - 163/27 C 50 Series Star (V) 380 400 415 440 380 400 415 440 380 400 415 440 380 400 415 440 Parallel Star (V) 190 200 208 220 190 200 208 220 190 200 208 220 190 200 208 220 Series Delta (V) 220 230 240 254 220 230 240 254 220 230 240 254 220 230 240 254 kva 15.0 15.0 15.0 12.7 16.0 16.0 16.0 13.5 kw 12.0 12.0 12.0 10.2 12.8 12.8 12.8 10.8 Efficiency (%) 81.8 82.4 82.8 83.2 81.0 81.7 82.1 82.6 kw Input 14.7 14.6 14.5 14.4 15.8 15.7 15.6 15.5 N/A N/A 60 Series Star (V) 416 440 460 480 416 440 460 480 416 440 460 480 416 440 460 480 Parallel Star (V) 208 220 230 240 208 220 230 240 208 220 230 240 208 220 230 240 Delta (V) 240 254 266 277 240 254 266 277 240 254 266 277 240 254 266 277 kva 17.8 18.8 18.8 18.8 18.9 20.0 20.0 20.0 kw 14.2 15.0 15.0 15.0 15.1 16.0 16.0 16.0 Efficiency (%) 82.0 82.2 82.7 83.2 81.3 81.4 82.0 82.5 kw Input 17.4 18.3 18.2 18.1 18.6 19.7 19.5 19.4 N/A N/A DIMENSIONS Barnack Road Stamford Lincolnshire PE9 2NB Tel: 00 44 (0)1780 484000 Fax: 00 44 (0)1780 484100 2006 TD_BCI164D.GB_10.06_04_GB