Instruction Sheet P/N _01 3/2013

Similar documents
11-1 Electrical System NOTE: Table of Contents Electrical System

Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a Universal in-out filter.

Type V Accent Light Installation

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an in-out filter.

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an out-in filter.

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V

Series AD-31 Handgun Swivel Connector Replacement Kit P/N and P/N

E-200 O-rings Service Kit

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with C-style cordsets.

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with M-style cordsets.

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a threaded filter.

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with bead or slot modules.

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)

DASH AUDIO KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev 01 04/16 Page 1 of 6. Verify accessory fitment at Polaris.com.

CHEMICAL MIXING SYSTEM OPERATING AND INSTALLATION INSTRUCTIONS

Air Spray Proportioning Valve

Installation Instructions for Series 3100V Low Level Indicator

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11

Replacing a Gun RTD. Instruction Sheet P/N B. 1. Introduction. Using this Instruction Sheet

FlexJet Carriage Circuit Board (PCB) Replacement

LOCKN LOAD MOUNTING KIT

INSTALLATION MANUAL. Fendt VarioGuide Ready COM 3 Supported Models PN REV A

MULTI-P URPOSE S HELTER

Upgrading the Sure Coat Modular Gun Control System

E-200 Module Service Kit

Instruction Bulletin. Jockey Pump Controller

QUICK REFERENCE MANUAL

A-dec 371L or 571L Dental Light on an A-dec 361, 362, or 363 Support Center INSTALLATION GUIDE

A-dec Dental Lights on an A-dec 300 Base Mount Post INSTALLATION GUIDE

SP30 10:1 Piston Pump

RMK HANDLEBAR KIT P/N ; ; APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

Installation Guide. Philips MP20/30/40/50 IntelliVue VHM Wall Mount Kit

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V

INSTALLATION INSTRUCTIONS

Pattern Air Control Kit (PACK)

Mirror Solutions Bevel & Pivot Models Installation Instructions INSTALLATION INSTRUCTIONS. Figure 1

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

FRONT STABILIZER BAR KIT

NOTE: DISCONNECT MAIN POWER LOCK OUT AND TAG BEFORE PERFORMING ANY PROCEDURES IN THIS SECTION.

Series 3900/M Pump Retrofit Kit

Installation Guide VHM Wall Mount Kit for Philips MX600/700/800 and MP60/70 IntelliVue

Installation Instructions For Motor Control Center (MCC) Units

Product Bulletin SEB PCM and Product Reliability

CALIBRATION PROCEDURE FOR THE ALLEN-BRADLEY PLC TEMPERATURE CONTROLLER:

Air Collet Closer - Upgrade - OL-1

SINGLE ACCENT LIGHT KIT

ARCHWEIGH 1000 BELT SCALE WITH TOUCH PANEL DISPLAY

In addition to this instruction sheet, the following are included in this kit (some additional parts are included for future maintenance):

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3400V 3500V 3700V

LANCER FOG LAMP KIT MZ380479EX (for RHD) INSTALLATION AND HANDLING INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Altec LMAP. (Load Moment and Area Protection) Telescopic Boom Cranes. Calibration

INSTALLATION INSTRUCTIONS

Star Trac Fitness E Series Bikes E- UB 8100/ E- RB Install Guide

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

CANVAS DOOR KIT P/N , APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

INSTALLATION INSTRUCTIONS

FlexJet - Flex Cable Replacement

5. Keep rotating the water pump housing to release the belt tension and remove the belt once it becomes loose.

Installation Guide Philips MP90 VHM Wall Mount Kit

Your Global Flow Control Partner. Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

POLY TIP-DOWN WINDSHIELD KIT

Timing Belt Replacement

GPS Steering System Installation Manual

T3 SERVICE HANDLE SERVICE

INSTALLATION GUIDE AV7900 Dual Multimedia Headrest Replacement System

Replacement of Refrigerant Compressor Belt Pulley Due to Noise Complaints or No Cooling (P-B-83.55/119a, March 17, 2009)

Installation Instructions

7C MERGER M40/50RF SYSTEM INSTALLERS GUIDE

OEM TM-50 Quick Start Guide

INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE Car Show Dual DVD Headrest Replacement System

IMPORTANT ATTENTION INSTALLERS:

User Manual for the ProFlow 1K Release: User Manual for the ProFlow 1K_Rev_A PVA Support Hub. User Manual for the ProFlow 1K

Blow Off Valve Retrofit Kit

TABLE OF CONTENTS I. SERVICE & MAINTENANCE PROCEDURES. 1) Opening and closing of door latch. 2) Latch assembly and adjustment

Export Service Bulletin

FOR SIT-STAND WORKSTATION

Checker Unload Checkstand Installation Instructions

TPMS TP200 USER S MANUAL

INSTALLATION & OWNER S MANUAL

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

FIGURE 2-1: LIFT (LEFT-SIDE) MOUNTING HOLES

HexPro Series Low Profile Wrenches

INSTALLATION & OWNER S MANUAL

Back Pressure Regulator

INSTALLATION INSTRUCTIONS FOR DSP9600/9100 WHEEL BALANCER

INSTALLATION INSTRUCTIONS

A-dec 541 Delivery System and 545 Assistant s Instrumentation

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Manual. AutoSteer. Gleaner Combine. AutoGuide 2 Steer Ready. Supported Models A66 A76 R66 R76 S67 S77 PN: A

VL400 Melters. Safety. Introduction. Nordson Corporation OPERATOR S CARD P/N A

TECHNICAL DOCUMENT. PCNC Mill Enclosure Door Switch Kit. Installation

Transcription:

Instruction Sheet P/N 222_0 3/203 AltaBlue TT Melter Service Kit - P/N 249 This instruction sheet describes the upgrade or replacement of the motor assembly in the AltaBluet TT adhesive melter, model A4TP, P/N 50757. Remove the WARNING: Risk of personal injury or equipment damage! Refer to the safety information provided in the melter manual before servicing the melter. Failure to comply with the safety information provided can result in personal injury, including death. Required Tools: Phillips-head screwdriver 0- and 3-mm wrenches 3- and 4-mm hex keys. Switch the melter off. WARNING: Risk of electrocution! The control switch does not remove high-voltage power from the melter. Before opening the electrical compartment door, make sure the local power disconnect switch is in the off position and locked. Failure to properly disconnect the power from the melter can result in personal injury, including death. 4. Remove the four bolts () that secure the motor to the pump bracket. 5. Pull the motor, with the motor shaft coupling half (2) attached, away from the pump bracket until the motor assembly is outside the melter. 2. Disconnect power to the melter at the local power disconnect switch. NOTE: Make sure the coupling star remains on the the pump shaft. Strain relief 3. Remove the front cover. NOTE: The motor being removed may look different from the replacement motor. 6. Removethecouplingfromthemotor shaft. It will be installed on the replacement motor. 2 3 7. Remove the motor junction box cover (3) and disconnect all the motor cable leads from the terminal block inside the motor junction box. 4 8. Loosen the strain relief (4) retaining nut that secures the motor cable and remove the motor cable from the junction box.

Instruction Sheet (contd.) P/N 222_0 Page 2 Install the Replacement. Install the motor shaft coupling half () on the replacement motor (2), leaving the coupling set screw loose. 5. Reinstall the motor junction box cover (5). 6. Tighten the strain relief retaining nut. 9. Tighten the four pump bolts (6) to 3.5-6.3 NSm (0-2 ft-lb), then make sure the coupling assembly still slides freely across both shafts. 2. Loosen the set screw on the pump shaft coupling half (not visible). 3. Install the strain relief (3) from the kit in the bottom access hole on the motor junction box, but do not tighten the retaining nut. 4. Route the motor cable (4) through the strain relief into the junction box and connect the leads to the L, L2, L3, and PE terminals. 7. While aligning both halves of the coupling assembly, including the bronze center star, position the motor against the pump bracket and loosely install the four pump bolts (6). 8. Check the initial alignment of the drive assembly by sliding the coupling halves and star back and forth over the motor and pump shafts. The coupling components should move freely without binding. If they do not, adjust the position of the motor until free movement is achieved. 0. Center the coupling assembly over the shafts such that the star covers the gap between the shafts and then set a 2-mm (0.080-in.) gap between the star and one coupling half.. Tighten all the coupling set screws. 2. If the motor you replaced is different from the motor included in this service kit, continue to the next page to change the motor drive parameters. 5 2 If the motor you replaced is the same as the motor included in this service kit, continue to page 5 to check the motor rotation. 6 3 4 drive cable terminal block connections 3.5-6.3 NSm (0-2 ft-lb)

Instruction Sheet (contd.) P/N 222_0 Page 3 Change the Drive Parameters (If Applicable) NOTE: If the motor you replaced is different from the motor included in this service kit, perform this procedure to update the motor drive parameters. Refer to the melter manual for the procedure for viewing or changing any motor drive parameter and for lists of all the motor drive parameters and their default and customer settings. WARNING: This procedure is performed with the power on and the electrical enclosure open. Allow only personnel with appropriate training and experience to operate or service the equipment. The use of untrained or inexperienced personnel to operate or service the equipment can result in injury, including death, to themselves and others and can damage the equipment. To update the settings menu (ACC) parameters. Press the Enter button. The display shows REF. 2. Rotate the jog dial clockwise (CW) until the display shows SET. The display shows ACC. display shows ith. 5. Press the Enter button and observe Display Jog dial rotate () to move forward (clockwise) or backward (counterclockwise) through the menus or (2) to increase (clockwise) or decrease (counterclockwise) a value. Enter button press () to move through the programming steps or (2) to confirm/enter the displayed value. ESC button press () to exit a menu or parameter and return to a previous step or (2) to clear an entry and revert to the value stored in memory. To prepare for update. Switch the melter on and make sure the heaters are on. 2. Disable the pump. 3. Open the melter electrical enclosure and locate the motor drive. 6. Rotate the jog dial clockwise or 7. Press the Enter button to store the value 8. Press ESC to exit the parameter. The display shows ith. 9. Rotate the jog dial clockwise until the display shows Ctd. 0. Press the Enter button and observe Table. Customer Settings for the Parameters ChangedinthisProcedure Menu Parameter Customer Setting ACC ith Ctd drc ncr nsp 620 COS 0.69 FUn Adc sdc. sdc2 0.8. Rotate the jog dial clockwise or 2. Press the Enter button to store the value 4. Open the access door on the drive. The display shows rdy. 3. Press ESC to exit the parameter. The display shows Ctd.

Instruction Sheet (contd.) P/N 222_0 Page 4 Change the Drive Parameters (If Applicable) (contd.) To update the motor control menu (drc) parameters. Press ESC to exit the menu. The display shows SET. 2. Rotate the jog dial clockwise until the display shows drc. display shows ncr. 5. Press the Enter button and observe the value on the display. 6. Rotate the jog dial clockwise or 7. Press the Enter button to store the value 8. Press ESC to exit the parameter. The display shows ncr. 9. Rotate the jog dial clockwise until the display shows nsp. To update the motor control menu (drc) parameters (contd.) 5. Press the Enter button and observe 6. Rotate the jog dial clockwise or counterclockwise until the display shows 0.69. 7. Press the Enter button to store the value. 8. Press ESC to exit the parameter. The display shows COS. To update the applications function (FUn) menu parameters. Press ESC to exit the menu. The display shows drc. 2. Rotate the jog dial clockwise until the display shows FUn. display shows AdC. To update the applications function (FUn) menu parameters (contd.) 0. Press ESC to exit the parameter. The display shows sdc.. Rotate the jog dial clockwise until the display shows sdc2. 2. Press the Enter button and observe 3. Rotate the jog dial clockwise or counterclockwise until the display shows 0.8. 4. Press the Enter button to store the value. To exit the setup mode. Press ESC. The display shows sdc2. 2. Press ESC to exit the menu. The display shows AdC. 3. Press ESC to exit the menu. The display shows FUn. 0. Press the Enter button and observe. Rotate the jog dial clockwise or counterclockwise until the display shows 620. 2. Press the Enter button to store the value 5. Press the Enter button. 6. Rotate the jog dial clockwise until the display shows sdc. 7. Press the Enter button and observe the value on the display. 4. Press ESC to exit the setup mode. The display shows rdy. The motor drive is now ready for operation. 5. Close the motor drive access door, close the electrical enclosure, and continue to the next page to check the motor rotation. 3. Press ESC to exit the parameter. The display shows nsp. display shows COS. 8. Rotate the jog dial clockwise or counterclockwise until the display shows.. 9. Press the Enter button to store the value.

Instruction Sheet (contd.) P/N 222_0 Page 5 Check the Rotation of the. Switch the melter on, manually start the pump, and make sure the coupling () is rotating clockwise. If the coupling is not rotating clockwise, switch off the melter, disconnect and lockout power, and make sure the motor cable terminal block connections are correct inside the motor junction box. Restore power and check the rotation again. Repeat this process until the coupling is rotating in the correct direction. 2. Reinstall the melter front cover and restore the system to normal operation. drive cable terminal block connections