RF80-K Aircraft Battery Charger / Analyzer

Similar documents
RF80-M. Features. Lead Acid Batteries Multistep Programmable. Automatic Operation Stores 100 Programs

RF80-M. Features. Lead Acid Batteries Multistep Programmable. Automatic Operation Stores 100 Programs

OPERATING INSTRUCTIONS

INSTRUCTION MANUAL CAUTION

1. INTRODUCTION AND SYSTEM DESCRIPTION CONDENSED OPERATING INSTRUCTIONS SPECIFICATIONS CONTROLS AND DISPLAYS...

1. INTRODUCTION AND SYSTEM DESCRIPTION GLOSSARY CONDENSED OPERATING INSTRUCTIONS... 8

CONTENTS TABLE OF CONTENTS... 1 INTRODUCTION... 2 SEC 1 - SPECIFICATIONS... 3 SEC 2 - DESCRIPTION... 5 SEC 3 - OPERATING INSTRUCTIONS...

FEATURES Charges two 6- to 8-cell NiCd/NiMH battery packs simultaneously Fully automatic operation Multi-color LEDs indicate state of charge at a

1. INTRODUCTION AND SYSTEM DESCRIPTION GLOSSARY CONDENSED OPERATING INSTRUCTIONS... 8

OPERATING INSTRUCTIONS

1. INTRODUCTION AND SYSTEM DESCRIPTION GLOSSARY CONDENSED OPERATING INSTRUCTIONS... 9

Care and Feeding of Rechargeable Batteries. Chris Capener March 1, 2012

PCBA Instruction Manual

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

CHAPTER 3 BATTERY MANAGEMENT AND SUSTAINMENT SYSTEMS (BMASS) EQUIPMENT DESCRIPTION SHEETS

1. INTRODUCTION AND SYSTEM DESCRIPTION BLOCK DIAGRAM GENERAL INFORMATION GLOSSARY... 7

Lithium Battery Systems for Aerospace Applications

Activator 282 Aircraft Battery Maintenance Charger Operator Manual

Sealed Lead-Acid Batteries

DIESEL Engine Fire Pump Controllers Features

INTRODUCTION. Specifications. Operating voltage range:

Programming of different charge methods with the BaSyTec Battery Test System

NeverDie Battery Management System Section 1: Overview

Service Information Letter

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

BS20 BATTERY CHARGER For lead-acid batteries

Nickel Metal Hydride Battery Pack. User Handbook

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT: READ AND SAVE THIS SAFETY AND INSTRUCTION MANUAL. KEEP IT WITH OR NEAR CHARGER AT ALL TIMES.

HIGHLIGHTS. What Every 3M Powered Air Purifying Respirator User Should Know About Batteries

Product Evaluation. CADEX C7400 Battery Analyzer

Advanced Troubleshooting Guide Snorkel V Battery Charger Rev 0 3JAN07

Technical Note. Management of Sealed Lead Acid Batteries in Reliable Small DC Standby Power Supply Systems

Super Brain 977. AC/DC Charger with Dual Output and Discharge Function. User s Manual. Model Rectifier Corporation

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Super Brain 969 Pro AC/DC Delta Peak Charger with Dual Output and Discharge Function Instruction Manual Model Rectifier Corporation

DLRO 10 and DLRO 10X. Digital Microhmmeter. DLRO 10 and DLRO 10X Digital Microhmmeter. NEW interchangeable test lead terminations

Stationary Battery Testing

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

C8000. Advanced Battery Analyzer. cadex.com/c8

Sealed Lead-Acid Batteries

Sola/Hevi-Duty S3K Series Mini-Tower UPS

1. INTRODUCTION AND SYSTEM DESCRIPTION SPECIFICATIONS... 5

Switch Mode, Automatic, Lead Acid Battery Charger Model: SEC A SEC A SEC A

Specifications. Special features

AUTO CHARGE LPC SERIES

12V/25A BATTERY CHARGER MAINTAINER / JUMPSTARTER

Vented fibre structure Nickel Cadmium batteries for stationary systems

BK10 10 CHANNELS BANK CHARGER For 12V lead-acid batteries

MODEL ELC-12/40-CVM-D BATTERY CHARGER

Revise model name, charging level and printing mark. Battery cell P/N and MSDS included. Revise spec to comply with certification conditions

Batteries for HTM. D. J. McMahon rev cewood

Super PWRgate PG40S Spring City Drive Waukesha, WI

UP100AC INSTRUCTION MANUAL

Automatic DC Power Supply/Battery Charger

AUTO CHARGE 1200 PUMP PLUS

BATTERY CHARGERS FAN COOLED HIGH FREQUENCY CHARGERS UP 30% ENERGY SAVINGS! HIGH FREQUENCY BUILT-IN CHARGER AQHF24-30FC G2 TECHNICAL PECIFICATIONS

RU BMS Power Supply and Battery Management System Owners Guide

NeverDie Battery Management System Section 1: Overview

AUTO CHARGE AMPS DELUXE AUTOMATIC BATTERY CHARGER. Section 1: Single Battery Systems

Batteries for HTM. Basic Battery Parameters:

WARNING GENERAL DESCRIPTION

ASPIRO & GUARDIAN BATTERY MANAGEMENT WITH ACC EXTENDED CONTROLLER

BC-9000 OPERATIONS MANUAL BATTERY CHARGER COFKO ELECTRONICS LLC COPYRIGHT 2014 P/N

Manual Installation & Operation

ESCORT ELF and ESCORT LC SAMPLING PUMPS

BATTERY CHARGER Plus Battery maintainer & Rejuvenator

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Motive Power Solutions

Duracell Battery Glossary

ICS1702EB. ICS1702 Evaluation Board. Table 1 Cells R6 R8 1 Open Short 2 2.0k 2.0k 3 1.0k 2.0k 4 1.0k 3.0k 5 3.0k 12k 6 2.0k 10k 7 2.0k 12k 8 1.3k 9.

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

SPECIFICATION FOR VE 2/3A CONTENTS

MCC Automatic Start-Stop Microcomputer Charger Control

BREEZE PLUS LX40. OpErATInG InSTrUCTIOnS Please keep for future reference

GLOSSARY: TECHNICAL BATTERY TERMS

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

User s Manual. Automatic Switch-Mode Battery Charger

INTELLI-POWER BATTERY CHARGER 12 VOLT, 7 STAGE SWITCHMODE. P/No.s IC700, IC700W, IC1000, IC1500

BATTERY ENERGY GAUGE INSTRUCTION MANUAL

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

Constant Voltage/Constant Current Test System

TOTALIFT TL-Series Industrial Battery Charger

8-STAGE AUTOMATIC BATTERY CHARGER MCU CONTROLLED - HIGH FREQUENCY SWITCHMODE MODELS: KACHG1207, KACHG1212, KACHG1220, KACHG2410. Instruction Manual

NCPP. Nickel Cadmium Pocket Plate Batteries. Block Cell Dimensional and Electrical Data

PPS20 COMMUNICATIONS POWER SUPPLY AND BATTERY MANAGEMENT SYSTEM

MHP-TA RESETTABLE TCO DEVICE For Lithium Battery Protection

SURE TRIP RETRO KITS

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Warning! General Maintenance 4-11

SPECIFICATIONS CAA Supercharger

SWII Users Manual. Intercomp Co County Road 116 Minneapolis, MN (763) Fax

Emergency Power. Are you prepared? Rev 2.0

INTRODUCING THE LEAD CRYSTAL BATTERY

Computerized Charger, Discharger, Cycler INSTRUCTIONS

BATTERY CHARGER RS-1000 Instruction Manual

SUBSTATION EQUIPMENT - Page 1 of 8

LBI-31864D. Mobile Communications VEHICULAR CHARGER UNIT 19B801507P1, P4. Printed in U.S.A. Maintenance Manual

AUTOMATIC BATTERY CHARGER MODELS SEC A SEC A OWNER S MANUAL

Transcription:

RF80-K Aircraft Battery Charger / Analyzer Features Automatic Operation Heavy Duty Design And Performance Digital Timing / Display Charges And Analyzes Aircraft Batteries (3-75 AH) One-hour Main Charge, One-hour Discharge (NiCd) Unique ReFLEX Charging Constant Current Charging Reconditions NiCd Batteries Exclusive DigiFLEX Analysis Cell Voltage Balance Testing Full Three (3) Year Warranty

RF80-K Equipment Capabilities Functional and Versatile The RF80-K offers a wide selection of charging techniques for servicing and reconditioning NiCd, vented lead-acid, and sealed lead-acid batteries. Christie s exclusive ReFLEX charging method has the advantage of charging batteries faster without heating and in as little as one hour, while simultaneously reconditioning the batteries. Additionally, the RF80-K employs negative slope sensing as a built-in safety measure to prevent overcharging and possible thermal runaway. The RF80-K automatically performs a battery analysis with a pre-programmed charge-dischargerecharge cycle that matches the characteristics of each battery type. The charger/analyzer also performs a deep discharge to recondition NiCd batteries or prepare them for storage. ReFLEX Charge The RF80-K will perform the exclusive ReFLEX charge to fully and safely charge a battery in a little more than 1 hour. ReFLEX Charge Cycle The unique advantage of the ReFLEX charging method is that the positive charge current pulses alternate with the negative current pulses. When used on nickel cadmium batteries, the battery can be charged at twice the charge rate as a constant current charge. ReFLEX charging also provides: 1) lower battery end-of-charge temperatures, 2) cell balance restoration, 3) increased battery cycle-life, and 4) elimination of the nickel cadmium memory effect. In addition to the ReFLEX charge, the RF80-K is capable of constant current or constant potential charging as specified by all nickel cadmium and lead acid battery manufacturers. DigiFLEX Display The RF80-K also incorporates a special feature called DigiFLEX. The DigiFLEX circuitry provides measurement and display of the battery condition during the ReFLEX charge cycle. DigiFLEX uses the display of luminescent bars to portray the rate and duration of negative pulses throughout the charge cycle. The green luminescent bars show the relative state of charge of the battery. Green bars will initially appear when the battery has attained approximately 80% capacity. At full charge, the green luminescent bars will extend completely to the right side of the display on the RF80-K. DigiFLEX Trend Bar Display

RF80-K Equipment Capabilities Constant Potential Charge In constant potential charge mode, the RF80-K will charge all 6, 12, 24 and 28 volt vented or sealed lead-acid batteries. Constant Current Charge Nickel cadmium batteries can be constant current charged at up to 24 cells, as well as charging individual cells, or groups of cells. This method is also recommended for some lead-acid batteries. The charging rate and time in the constant current mode are adjustable. Two-Step Constant Current As an alternative charge method, the RF80-K can provide a high charge rate for a certain period of time, then drop to a lower charge rate for an equal charge period. Negative Slope Sensing When charging causes the temperature of NiCd batteries to rise, the voltage of the batteries diminishes, which can result in further heating. As a safety feature, the RF80-K employs negative slope sensing of the charge curve to detect over-charging, and halt possible thermal runaway of the battery. Short, Long, and Deep Cycles During the short cycle, the battery is discharged based on criteria established by the operator. If the battery drops below a minimum acceptable voltage level before the end of the preprogrammed period, the red Battery Reject light illuminates. In the long cycle, the battery voltage is brought to approximately one volt per cell. The exact ampere-hour capacity of the battery can be determined. Voltage/Current Monitoring The RF80-K permits the voltage or current of the battery to be monitored at any point in the process, from initial adjustment of the charge, or discharge, current through completion of the charge, discharge, or recharge stages. Cell-By-Cell Testing Front panel jacks allow a pair of test probes to be connected to the RF80-K. When the meter switch is in the cell volts position, the probes can be used to check the voltages of individual battery cells, or groups of cells. Optional Wait State To enhance battery life, the RF80-K can be programmed to introduce a wait state after the discharge portion of the analysis, allowing the battery to cool before automatic recharge takes place. DataFX Battery analysis by individual cell performance and condition is offered when used in conjunction with the DataFX. Aside from instantaneous cell voltage measurement duing the service cycle, the DataFX monitors cells for error conditions such as cell imbalance, low cell voltage, negative slope, and reversed cell polarity. The DataFX has an RS232 port for delivery of data to a PC interface or to a serial printer, further facilitating the automation of data management, often required by the battery manufacturer, the aircraft owner and/or the regulatory authorities.

RF80-K Controls And Indicators All controls and indicators for the RF80-K Charger/Analyzer are conveniently located on the instrument s front panel. To facilitate use of the RF80-K, the operating controls and displays are located generally in three functional groupings: a) Charger function, b) Analyzer function, c) Metering function. The Mode Switch, between the charge and analyze sections, allows the process to be selected. The charge method is chosen by a switch in the lower part of the Metering sector. 5 6 12 3 13 2 14 15 1 16 4 7 8 9 10 11 17 1) AC Power Switch: Primary ON-OFF switch. Charger Section 2) Set Charge Time: Establishes charge time. 3) Time To Charge: Displays charge time remaining. 4) Charge Current Adjust: Allows charging current to be set to desired value. Analyzer Section 5) Cycle Indicators: Green = cycle complete. Red = battery rejected. Yellow = negative slope sensing. 6) Elapsed Discharge Time: Displays elapsed time. 7) Mode Switch: Selects RF80-K process. 8) Cycle Reset: Resets the automatic cycle to the beginning of the selected mode. 9) Discharge Current Adjust: Sets discharge current rate. 10) Set Discharge Time: Sets total discharge time. 11) Discharge Cycle: Switch for Short, Long, or Deep discharge options. Metering Section 12) Metering Display: Displays battery voltage, cell voltage, or charge/discharge current. 13) DigiFLEX : Trend bar display showing relative state of charge and battery health. 14) Meter Switch: Selects metering display inputs. 15) Cell Volts: Jacks for test leads permitting cell-bycell testing. 16) Charge Method Switch: Selects type of charging to be performed. 17) Battery Type Switch: Selects proper ReFLEX charge for battery under analysis.

RF80-K Aircraft Battery Charger / Analyzer RF80-K Specifications Mechanical 18.55 inches (47.12 cm) wide 11 inches (27.94 cm) high 21.5 inches (54.61 cm) deep Weight: 145 pounds (65.90 kg) Case material: Steel Front Panel: Steel w/polyester overlay Electrical Input Input voltage: 187 to 265 VAC, single phase Frequency: 47 to 63 hertz Current: 25 amps maximum Power Switch: Opens both sides of line Electrical Output Charge, ReFLEX : 2-80 amps Charge, constant current: 1 65 amps Charge, constant potential: 1 65 amps Discharge, constant current: 1 60 amps Electrical Displays Current: 99.9 amps full scale +/- 2% Voltage: 99.9 volts full scale +/- 2% Individual Cells: 19.9 volts full scale +/- 2% DigiFLEX : 10 segment red/green trend bar Environmental Non-operating -40 F - +159.8 F (-40 C - +71 C) Altitude: 0 50,000 feet Operating +32 F - +122 F (0 C - 50 C) Altitude: 0-8,000 feet Warranty Three years on parts and labor. Marked and Certified RF80-K Standard and Optional Accessories Standard: Cell probe Kit P/N 526020-065 Cable Adapter - Quick Disconnect P/N 121666-001 Cable Adapter - Universal P/N 121666-002 Options: Calibration Shunt P/N 121666-010 2/11 cell battery module cable assembly* P/N 121961-001 3/7 cell battery module cable assembly * P/N 121961-003 DataFX / ProEase P/N 121711-004 *Max total cells 24 NiCad, 14 Lead Acid MarathonNorco Aerospace, Inc. 8301 Imperial Drive Waco, TX. 76712 (254) 776-0650 FAX (254) 776-6558 CHRISTIE