DATA-SHIELD PURE LEAD VRLA UPS BATTERIES

Similar documents
PURE LEAD PLUS UPS APPLICATIONS. Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

Modular Max Range BATTERY SOLUTIONS. NEBS qualified. Reliable capacities. EverExceed power your applications

Valve Regulated Lead Acid (VRLA) Battery Series Designed for UPS Standby Power Applications FEATURES & BENEFITS

NCPP. Nickel Cadmium Pocket Plate Batteries. Single Cell Catalogue

PURE LEAD PLUS UPS APPLICATIONS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

Modular Max AGM Range VRLA

FAT. FAT Battery Range FIAMM.COM

SPECIFICATIONS. Top Terminal Batteries. SECTION A Division of Exide Technologies

MHR VRLA batteries are manufactured in compliance with TL, NEBS, GR, SR, IEC, BS, UL, ISO, OSHAS and CE quality and performance standards.

SSLA. SSLA Battery Range FIAMM.COM

SSLA. SSLA Battery Range FIAMM.COM

UPS FEATURES & BENEFITS TECHNICAL DATA Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications.

Pure Lead-Tin Technology

SECTION

Ampere Hour 77 F (25 C) Weight Weight Model #Cells/Voltage

FEATURES & BENEFITS. 10 year design 25 C

FEATURES & benefits. Constant Power Discharge Ratings - Watts per 77 F (25 F) Operating Time (in minutes) to 1.

SPA AGM VRLA batteries

Tubular Gel Technology For Solar Applications

AINO MICRO RANGE VRLA. Compact energy for increased security BATTERY SOLUTIONS. EverExceed power your applications

1 2 V F T A S E R I E S

SECTION

DataSafe HX Top Terminated Batteries 6 and 12 Volt HX

SECTION A Division of Exide Technologies

2 Volt AGM Range. Haze Battery Company Ltd

LIBERTY SERIES 1000 VALVE REGULATED LEAD-CALCIUM BATTERY For standby applications Capacities from 25 to 600 Ampere-hours

PowerStor Standby Battery Systems

SVTX AGM VRLA batteries

Deep Cycle AGM Range VRLA

Switchgear Utility specific gravity nominal sulfuric acid. 10 years, full float service at 77 F (25 C)

AGM / GEL BATTERY RANGE

CELLYTE 12 PLF & 12PLT Range

OSP Battery Training. Craig Paoli Director Strategic Platforms July 13 th Copyright 2010 The Alpha Group. All Rights Reserved.

OPzV Batteries for Stationary Applications

Industrial Batteries / Network Power. Sprinter P / XP.»Reliable power for increased ed security«

PRODUCT GUIDE Publication No: EN-SBS-PG-001 February 2003

NCPP. Nickel Cadmium Pocket Plate Batteries. Block Cell Dimensional and Electrical Data

NCPP. Nickel Cadmium Pocket Plate Batteries. Single Cell Dimensional and Electrical Data

6 & 12 Volt Monobloc. Haze Battery Company Ltd

RES OPzV Premium Quality Batteries. for Renewable Energy Storage

RES OPzV Premium Quality Batteries. for Renewable Energy Storage

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc

Dependable power for mission critical operations

Features and Benefits

Haze Battery Company Ltd. Sealed Lead Acid 2 Volt Bloc. Gelled Electrolyte Range

Industrial Batteries / Network Power. Marathon M FT.»AGM modular power«

SECTION 26.10C A Division of Exide Technologies

Industrial Batteries / Network Power. Marathon M-FT.»AGM modular power«

OPzV Batteries. for Stationary Applications

OPzV Batteries. for Stationary Applications

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc

Industrial Batteries / Network Power. Marathon M FT.»AGM modular power«

6 & 12 Volt Monobloc GEL Range

Vented fibre structure Nickel Cadmium batteries for stationary systems

LIBERTY 2000 SuperMAX For standby applications Capacities from 295 to 2000 Ampere-hours

EV Traction Dry Cell Battery Technology

EV Traction Dry Cell Battery Technology

Battery Performance Specifications

NorthStar Battery Company DCN: SES DCR: 1548-S09 Date:

Haze Battery Company Ltd

GEL Technology

Industrial Batteries / Network Power. Sonnenschein A400 FT.»The dryfit range for modular performance adaption«

BATTERIES BATTERIES VRLA / SLA / GEL 2V/6V/12V. DP Electronics e.k (Deutsche Power Co., Limited)

Battery Range Summary

EV Traction Dry Cell Battery Technology

V R L A HI-PERFORMANCE BATTERIES

Multilink Transportation Power Solutions

Reserve Power OPzV Batteries

Reserve Power OPzV Batteries

C&D Technologies, Inc.

Battery Solutions. Presented by Wouter Vink Business Development Manager Enersys Powertech Reserve Power / DC Power Solutions

SECTION A Division of Exide Technologies

OPzV Batteries. Technical Data

SECTION 26.10C

PERFORMANCE SPECIFICATIONS

Industrial Batteries / Network Power. Marathon L / XL.»More energy for safer storage«

Tubular Flooded (OPzS) Batteries

RENEWABLE BROCHURE. World Class Battery Engineering Flooded & AGM Batteries

Uptimax New Generation Ni-Cd battery. Maintenance-free solution for backup power applications

VRPP. Nickel Cadmium Valve regulated Pocket Plate Batteries. Dimensional and Electrical Data

Single Cell Range including LCE P LBE P

SEC. MICROLYTE +Plus. Industrial Battery Co. Supplied Worldwide by: Visit our website on Features. Application

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. Gelled Electrolyte Range. Monobloc

Wide operating temperature range: Our battery will operate from -30C to (-22F) to 60C when it is fully charged.

Tubular Gel (OPzV) Batteries. Stationary & Renewable Energy Applications

EUROBAT EUROBAT GUIDE FOR MOTIVE POWER VRLA BATTERIES

ULTIMA Ni-Cd BATTERY: PEAK PERFORMANCE WITH ULTRA LOW MAINTENANCE

Lithium-ion battery systems for ABB UPS solutions Reliable, lightweight and compact UPS energy storage for critical applications

SECTION A Division of Exide Technologies

Haze Battery Company Ltd

Uptimax New Generation Ni-Cd battery. Maintenance-free solution for backup power applications

Product Guide. An Invensys company

SECTION

Power to keep you on the move

Uptimax New Generation Ni-Cd battery. Maintenance-free solution for backup power applications

INSTRUCTION MANUAL. Maintenance-free Absorbent Glass Mat technology and valve-regulated batteries. (AGM / VRLA)

Industrial Batteries / Network Power. Sprinter P / XP.»Reliable power for increased security«

Long Duration MCT LEAD CALCIUM H1T LEAD CALCIUM SECTION

SECTION

Battery Selection Guide

Transcription:

DATA-SHIELD PURE LEAD VRLA UPS BATTERIES

Pure Lead VRLA Batteries for UPS HBL s range of Data-Shield high rate batteries are designed to provide the highest discharge rates for critical datacenter/ups applications. Advances in datacenter technology, high availability of the utility grid and on site generation have all contributed to shorter UPS back-up times. Data-shield has been designed with this in mind. The product delivers industry leading performance at back up times of 10 minutes or less. The critical back up time to allow standby generators to start and synchronize is typically less than 5 minutes. Data-shield delivers its optimal performance at these rates. The datacenter designer will reduce the battery footprint, reduce the cost and size of rectifiers, and save money by lowering energy consumption in cooling plants and recharging. HBL s Data-Shields electrical and high temperature performance exceeds all normal AGM VRLA products. It offers users a wide, flexible range of capacities and the choice of top terminal and front terminal designs. Outstanding design features ensure the total integrity and reliability of UPS installations. WHEN YOU RELY ON YOUR UPS - RELY ON DATASHIELD.

Features and Benefits 12+ year life expectancy at 20 C No Topping Up/Maintenance Free Flame retardant case materials for safety, security and peace of mind Highest power available from lead batteries today, specifically designed for <10 minute UPS applications Pure lead plates - improving high temperature tolerance UL Recognized component Faster recharge times than traditional AGM VRLA protecting your data and datacenter for repeated outages Storage life of 2 years at 20 C protecting your investment against project start-up delays and allowing distributors to reliably hold inventory 100% recyclable Low energy requirements for recharge, and less heat generation Front and top terminal designs in multiple voltage configurations for convenient retrofit of life expired systems 13 available sizes with 5 minute ratings from 109-2520 Watts per cell

Data-Shield UPS Batteries PURE LEAD VRLA BATTERIES FOR UPS CONSTRUCTION OPERATION STANDARDS AND QUALITY Pure Lead grids with customize active materials for high temp performance. enhanced grid design for high power discharges Separators with fully absorbed electrolyte Pure sulphuric acid with no contaminants Leak proof post seals with custom welded security ABS case and lid UL94 V-0 flame retardant rating Case-lid heat seal with high integrity bond ensuring no leaks. High security pressure vents for operational safety Battery posts with copper inserts to carry high currents of short rate discharges Shock and vibration resistant designs. Handles for ease of installation Maximizing capacity and recombination Batteries designed for easy mounting on racks or in cabinets No separate battery room required Low maintenance, no water additions Float Voltage2.27vpc @25 C/77 F Datashield batteries should be installed on their base. Special horizontal mount racks can be designed for certain batteries if required. Widest operating temperature -40 C to +50 C. Storage life up to 24 months at 20 C without freshening charge Inter-block connectors can be supplied to specific layouts and rack configurations Compliant with the requirements of international standard IEC 60896-21/22 HBL sizing program uses IEEE485 methodology Classified as Very Long Life (>12 years) according to the 2015 Eurobat guide UL recognised component Classified as non-spillable and approved as non-hazardous cargo for ground, sea and air transportation in accordance with the requirements of IMDG (International Maritime code for Dangerous Goods) and ICAO (International Civil Aviation Organisation) The management systems of HBL governing the manufacture of DataShield products are ISO 9001:2008, ISO 14001:2004 certified by Bureau Veritas.

Dimensional and Electrical Data Capacity Type C10 @25 C Length Width Height Weight Watts / cell to to1.80vpc 1.67vpv @ 25 C 12V Top Terminals mm in mm in mm in Kg lbs 1 min 5 min 10 min 20 min DS 12-109 13 175 6.89 85 3.35 130 5.12 5 11.02 182 109 72 58 DS 12-134 16 181 7.13 76 2.99 168 6.61 6 13.23 224 134 88 70 DS 12-252 30 163 6.42 142 5.59 200 7.87 12 26.46 420 252 165 140 DS 12-319 38 249 9.80 97 3.82 201 7.91 13 28.66 532 319 209 164 DS 12-420 50 220 8.66 121 4.76 245 9.65 19 41.89 700 420 275 215 DS 12-588 70 330 12.99 168 6.61 176 6.93 23 50.71 980 588 385 300 DS 12-840 100 410 16.14 175 6.89 225 8.86 36 79.37 1250 840 550 437 DS 12-1260 150 525 20.67 220 8.66 225 8.86 56 123.46 1875 1260 825 660 12V Front Terminals DS 12-608 75 490 19.29 110 4.33 225 8.86 24 52.91 900 608 390 296 DS 12-810 100 510 20.08 110 4.33 240 9.45 32 70.55 1200 810 520 394 6V Top Terminals DS 6-1008 120 205 8.07 197 7.76 235 9.25 23 50.71 1500 1008 660 473 DS 6-1176 140 205 8.07 197 7.76 235 9.25 25 55.12 1750 1176 770 552 2V Top Terminals DS 2-2520 300 209 8.23 139 5.47 283 11.14 19 41.89 3750 2520 1650 1285

Terminal Arrangements: DS 12-109 DS 12-134 DS 12-252 DS 12-319 DS 12-420 DS 12-588 ALL DIMENSIONS ARE IN INCHES

Terminal Arrangements: DS 12-840 DS 12-1260 DS 12-608FT DS 12-810FT DS 6-1008 DS 2-2520 All data contained in this brochure is for customer guidance it is contractually confirmed onlyat time of order

Customer Service and Support HBL Power Systems Ltd. Road10, Banjara Hills Hyderabad, - 500034 Telangana, India contact@hbl.in (+91) 8418244640 (+91) 8418301640 HBL America Inc. 712, Brook St., Unit 107 Rocky Hill, Connecticut, 06067, USA www.hblbatteries.com (+1) 860 257 9800 HBL Germany GmbH. Emilienstraße 24A, 08056 Zwickau, Germany www.hblpower.de (+49) 375 390 96597