Pneumatic Isolation Module

Similar documents
PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Dry Contact Closure Interface

1329I Integrated Drive/Motor CE Filter Option Kit

TMS Series MP46x Flex Probes* Installation Instructions

Installation, Operation and Maintenance Manual

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

INSTRUCTIONS. Power Panel. Installation Instructions

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy

Centrifugal Constant Pressure Control

Automatic Changeover Medical Manifold Installation, Operation and Maintenance Manual

Trane Liqui-Flo Addendum. Instruction Manual D2-3415

Instruction Sheet. Subject: Installations Instructions. Air Compressor Kits. Importan

Han K 3/0, K 3/2 / Han HC Modular. Contents Technical characteristics Han K 3/0, Han K 3/ Inserts Han K 3/0, Han K 3/

Centrifugal Constant Pressure Control

Installation Instructions for Load Management Kit A051C329

ACE Variable Frequency Drive System

PCVS Series Control Valve Supervisory Switch

Operating instructions Form no safety definitions

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

MP461SC Flex Probes* Installation Instructions

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 10/14

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

Commander Pro 100 SUBMERSIBLE SYSTEM Installation, Operation and Trouble-Shooting Manual

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

Installation Operation Maintenance ADDENDUM BULLETIN No. PS-IOM-HYP-0203-H

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

MS Application. Features. Proportional Valve Actuator General Instructions

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

TIDALFLUX 2300 F Quick Start

MF4E MF4E

RollSeal 1733 County Road 68 Bremen, Alabama Part No Rev Owner s Manual RS-Divider Curtain

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

V4043 and V4044 Motorized Valves

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Instruction Bulletin. Jockey Pump Controller

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)

Quick Connection Panel (QCP) Installation Guide

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings

Application Description

CAT-1 Series 3. Installation Guide. The Valley Group, Inc. 871 Ethan Allen Hwy. Suite 104 Ridgefield, CT 06877

Hardware Installation. Tracer AH541 Version 2 Air-Handler Controller CNT-SVN02B-EN

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

FIELD CONNECTIONS FOR YK CHILLER (STYLE G) OPTIVIEW CONTROL CENTER WITH REMOTE MEDIUM VOLTAGE SSS

2.11. Limit Switches. Contents Description. Special Purpose Limit Switches. Special Purpose Limit Switches

High Frequency SineWave Guardian TM

Installation Operation Maintenance ADDENDUM

CP-8551 & CP Application. Features. Applicable Literature. Electronic to Pneumatic Transducers General Instructions

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

IMPORTANT SAFETY NOTICE

VOG Series VOG15.01xU1 Oil Safety Shut-off Valves with Proof of Closure (POC)

ATLAS FOOT OPERATED SWITCH

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

VC2, VC4, VC60, VC8 ON-OFF ACTUATOR FOR VC SERIES BALANCED HYDRONIC VALVES SPECIFICATIONS INSTALLATION INSTRUCTIONS

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

BUSWAY Low Voltage (Pow-R-Flex)

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

Bulletin 1494C Cable Operated Disconnect Switch Kit (400A) Installation Instructions (Cat 1494C- _ Series 2 : 400A)

MF /MS Series

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, P/N: , Revision 1

Network Zone System. Part Numbers: Z22N-****** Z22R-****

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

VD0C06N908C July 1998 Raleigh, NC, USA. Instruction Bulletin ALTIVAR 66, ALTIVAR 58, ALTIVAR 18. Dynamic Braking Resistor Kit User s Manual

Lifeline Medical Systems

UL/CSA Non-fused Disconnect Switches

Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

Installation Instructions For Motor Control Center (MCC) Units

Network Zone System Part Numbers: Z23N-***** Z23R-****

UZK12.071, UZO GENERAL DESCRIPTION 2. DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9.

CVR-625. Compact Vibrating Rod Instruction Manual

Owner's/Installation Manual

Installation and Commissioning of Auxiliary Power Unit

Lifeline Medical Systems

Low Profile Insertion Vortex

Hinged Safety Door Switch

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

Submersible Vacuum Fault Interrupters

CENTERLINE 2100 Motor Control Centers 600A, 800A, and 1200A Bolted Pressure Contact Switch

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return Rotary 24 Vac 3-position Control

Installation for Jeep Grand Cherokee SRT8 PN s , and 60634, 60635

UZK12.071, UZO DATA 1. GENERAL DESCRIPTION 4. MARKINGS 3. ORDER NUMBERS PASSIVE BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9.

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

UL Enclosed Disconnect Switches (Fused and Non-Fused)

EXTRA LARGE OUTDOOR HOUSINGS

SITRANS AS 100. Instruction Manual September 2001 ITRANS AS 100

Installation Instructions In-back/Out-back Cooling Kit for D5h/D6h and D7h/D8h Enclosures VLT Series FC 102, FC 202, and FC 302

Instructions for Installation, Operation, Care and Maintenance

1 M-3000-H4 F150 4X4 Lowering Kit

Transcription:

Pneumatic Isolation Module (Cat. 2030-Pxxxxx) ATTENTION: Hazardous Voltage or other forms of energy could be present. To avoid serious injury or death: Prior to beginning the installation and wiring process, make sure that all forms of energy to the installation site have been properly turned OFF and locked out. ATTENTION: This device is a component in a safety system. Do not defeat, tamper with, bypass or alter. Severe injury to personnel could result. Only qualified service technicians must perform service or maintenance. Resealing of the device is the responsibility of the person or organization performing the service or maintenance. Follow NFPA 70E requirements Specifications Description Enclosure Dimensions H x W x D (by port size designator) Degree of Protection (By enclosure type designator) Input Voltage Rating Status Indicator Lights Inlet Air Pressure Range (by air pressure designator) Inlet & Outlet Air Fitting Size (by port size designator) Connector Plug (HC) - Wire Size - Torque Operating Ambient Temperature Storage Ambient Temperature Storage Relative Humidity Agency Certification Specification 1, 3, 4 = 32.9 in. x 28.09 in. x 13.34 in. (835.66 x 713.49 x 338.84) 2 = 26.9 in. x 24.09 in. x 11.34 in. (835.66 x 713.49 x 338.84) 6 = 38.9 in. x 34.09 in. x 17.34 in. (988.06 x 865.89 x 440.44) A = NEMA Type 1 J = NEMA Type 12 C = NEMA Type 4X P = IP30 F = NEMA Type 4 W = IP65 H = IP54 24V DC and 120V / 60Hz 24V LED and 120V AC (neon) 120 = 30-120 psi 007 = 3-7 BAR Figure 1 Enclosure Mounting Dimensions for Pneumatic Isolation Module A Clearance Holes for #3/8-16 Mounting Hardware 1 = 1 in. NPT (inlet and outlet fittings are the same size) Cv=6.0 2 = 1/2 in. NPT (inlet and outlet fittings are the same size) Cv=3.1 3 = 3/4 in. NPT (inlet and outlet fittings are the same size) Cv=4.4 4 = 1 in. NPT (inlet and outlet fittings are the same size) Cv=8.5 6 = 1.5 in. NPT (inlet and outlet fittings are the same size) Cv=22.2 #14 AWG Max. 21mm 2 Max. 4.6 lb-in 0.5 Nm 0...+40 C (+32...+104 F) -10...+60 C (+14...+140 F) 5 95%, non-condensing UL, cul, TUV EN9541 Category 4, TUV EN60204-1, CE Overview The optional Pneumatic Isolation Module helps provide isolation of pneumatic energy to the machine or process. When an RLS is switched to the OFF position, the Pneumatic Isolation Module exhausts through the muffler on the module. The Pneumatic Isolation Module can be utilized as a part of the ElectroGuard Safety Isolation System manufactured by Rockwell Automation and designed for use with only these systems. Section 1 Mounting the Pneumatic Isolation Module 1. The Pneumatic Isolation Module enclosure is factory sealed. Installation of the module does not require opening the enclosure or breaking the factory seal. 2. Select the location for mounting the Pneumatic Isolation Module enclosure and mark locations for mounting bolt holes on the mounting surface. Use the mounting holes of the supplied enclosure as a guide or see Figure 1. B Port Size Designator=1,3,4 Port Size Designator=2 Port Size Designator=6 A B 18.00 in. 31.25 in. (457.20 mm) (793.75 mm) 14.00 in. 25.25 in. (355.60 mm) (641.35 mm) 24.00 in. (609.6 mm) 37.25 in. (946.15 mm) 42052-111-01 (1) Printed in U.S.A. 3. Drill and tap the holes in the mounting surface to accept the mounting hardware, four 3/8in.-16 UNC bolts.

Hazardous voltage. Risk of severe injury or death. Multiple sources of energy present. Only qualified personnel may service this equipment. Read instruction manual prior to servicing. 31035-090-01 (1) Section 1 (Cont'd) Mounting the Pneumatic Isolation Module ATTENTION: The enclosed module, weighs approximately 135 lbs. (62 Kg), includes two lifting eyebolts on its top surface (see Figure 2). Use the eyebolts an overhead hoist or other lifting means to transport, lift and position the enclosure for installing the mounting bolts. Assistance may be needed to avoid possible personal injury and/or equipment damage. 4. Partially install the two lower mounting bolts into the mounting surface so the bottom mounting feet of the enclosure can be placed over them. 5. Raise the enclosure into position and lower it down onto the two partially installed lower bolts. Figure 2 Lifting Eyebolts on Module Enclosure 6. Align the holes in the upper mounting feet on the enclosure with the upper two holes in the mounting surface and install the two upper mounting bolts. DANGER 7. Torque all four 3/8-16 mounting bolts to 22-32 lb-ft (30-43 Nm). 8. Detach the lifting means from the enclosure eyebolts. LIFTING EYEBOLTS Section 2. Connecting Customer Air Piping to Pneumatic Isolation Module Air Fittings Two hard-piped connections are required when the module is connected to a facility's compresses air sysytem. First connection is to the air inlet fitting located at the outer right hand side of the enclosure (see Figure 3). The other connection is to the air outlet fitting location on the outer bottom side of the enclosure (see Figure 4) The muffler and check valve do not require connections and must not be obstructed. Table 1: Summary of Pneumatic Module Input / Output Ports Designator Location Air Inlet Right Side Air Outlet Bottom HC (electrical connector) Right Side Function Connection for incoming air to module Connection for outgoing air from module Interface to Control Module Exhaust Muffler Check Valve Bottom Bottom Exhausts residual air pressure when RLS is in the "OFF" position. Pressure relief valve in the event of internal air leak in module enclosure. IMPORTANT: When installing air connections, the Pneumatic Isolation Module external pipe fitting must be held secure. Internal fittings may become loose and cause an air leak if not held secure. The compressed air supplied to the inlet of the Pneumatic Isolation Module must be dry and filtered. To extend the life of the valve, a 5µm filter and water trap must be installed before the air inlet and a water trap must be installed after the air outlet. When making the hard-piped air connections to the air inlet and outlet fittings on the module, a clearance of 6 in. (15 cm) should be observed for ease of installation and module replacement. Follow your facility's procedures when making the piping connections. Check pipe connections for air leaks when installation of the module is complete. 1. Verify all energy sources have been properly turned OFF and have been locked out or tagged out. 2. Connect the inlet air pipe to the inlet fitting on the right hand side of the Pneumatic Isolation Module. Use wrench to hold the air inlet fitting on the enclosure secure during installation and observe proper clearances from the fitting. Figure 3 Air Inlet Fitting on Right-hand Side of Module Enclosure Air Inlet Fitting (2)

Section 2 (Cont'd) Connecting Customer Air Piping to Pneumatic Isolation Module Air Fittings 3. Connect outlet air pipe to the outlet fitting on bottom of the Pneumatic Isolation Module. Use a wrench to hold the air inlet fitting on the enclosure secure during installation and observe proper clearances from the fitting. Figure 4 Air Outlet Fitting on Bottom of Module Enclosure Exhaust Muffler Air Check Valve Air Outlet Fitting 4. Check for air leaks around the inlet and outlet pipes. Section 3 The Pneumatic Isolation Module includes a single 24 pin electrical connector (HC), located on the outer, right hand side of the module enclosure (see Figure 5). This connector (referenced as HC in the connection diagrams) interfaces signals between the Pneumatic Isolation Module and the ElectroGuard Power Panel. Figure 5 Connector HC on the Right-hand Side of the Enclosure 1. Verify all energy sources to the ElectroGuard system have been properly turned OFF and have been locked out or tagged out. 2. Unfasten the HC connector hood from the bulkhead connector on the right hand side of the module by pushing the top and bottom hold-down tabs toward the module surface (see Figure 5) and then pulling the connector hood free. 3. Loosen the four insert attachment screws to remove insert from the hood (see Figure 6). Figure 6 Removing Insert from "HC" Connector Hood Attachment Screws (4) Places (3)

Section 3 (Cont'd) 4. Remove plugs HP1, HP2, and HV from the Control Module that this Pneumatic Isolation Module will connect to. To remove the HP1 and HP2 plugs, firmly grasp the strain relief tab and pull straight downwards. To remove the HV plug, loosen the two screws and pull downwards. IMPORTANT: The cable run between the Pneumatic Isolation Module and the Control Module in the ElectroGuard Power Panel must be protected from physical damage. This requires installing flexible conduit between the pneumatic Isolation Module and the ElectroGuard Power Panel. Pneumatic Isolation Module Cable Specifications IMPORTANT: Use #14 AWG control wire for distances < 500 ft (152m). Use #16 AWG control wire for distances < 300 ft (91m). Cable must have copper conductors only. Cable with 600V insulation is required. Oil resistant cable is recommended. Individual conductors within the cable should be color-coded or otherwise clearly marked. Cable must have a shield with a drain wire similar to ALPHA wire "XTRA-GUARD 2": - Part No. 25450/25 for #14 AWG, 0.98" O.D. - Part No. 25440/25 for #16 AWG, 0.93" O.D. IMPORTANT: Maximum allowable cable length between the Pneumatic Isolation Module and the ElectroGuard Power Panel is 500 ft. (152 m), based upon using cable with #14 AWG (21.mm) conductors or 300ft (91m) using cable with #16 AWG (13mm 2 ) conductors. Exceeding this length or using smaller conductor sizes may affect the reliable operation between the Pneumatic Isolation Module and the Control Module in the ElectroGuard Power Panel. 5. Wire to the 24-pin connector HC on the Pneumatic Isolation Module to the HP1, HP2, and HV plugs per connection diagram supplied with the 2 module ( see figure 8). IMPORTANT: HP1 and HP2 Control Module connector plugs and ports are factory keyed. This is done to ensure correct plug mating during installation after maintenance or servicing which may have required the removal of any of the connector plugs. The HV connector plug is not and does not require keying. Installing a connector plug into a port with non-matching keying may damage the connector as well as the Control Module port. IMPORTANT: The HP1 plug provided on ElectroGuard Control Modules are Factory shipped with three jumper wires installed ( see figure 7). These three jumper wires must be removed and discarded when wiring is performed to connect a Pneumatic Isolation Module to the HP1 plug. Failure to remove the three jumper wires prevents proper operation of the Pneumatic Isolation Module. Figure 7 HP1 Connector Plug Jumper Wire HP1 1 2 3 4 5 6 7 8 9 10 These three wires MUST be removed before connecting wiring from the Pneumatic Isolation Module HC connector (4)

Section 3 (Cont'd) Figure 8 Wiring Plug "HC" for the Pneumatic Isolation Module to the Control Module Connectors To HV GND To HP1 (1) To HP2 (1) To HP2 (3) 1 2 3 13 14 15 To HP1 (10) To HP1 (3) To HP1 (6) To HP1 (7) To HP1 (9) To HP1 (4) To HP1 (5) To I/O Pneumatic Valve Status 4 5 6 7 8 16 17 18 19 20 To I/O Pneumatic Valve Status To I/O Pressure Switch Status 1 To I/O Pressure Switch Status 1 To I/O Pressure Switch Status 2 To I/O Pressure Switch Status 2 To HP1 (2) To HP2 (2) To HP2 (4) 9 10 11 21 22 23 To HP1 (8) 12 24 HC Connector 6. If a customer supplied Remote Communications Device is to be connected to the Pneumatic Module, wire that to the HC plug per Figure 9. Figure 9 Wiring the Pneumatic Isolation Module Status Signals Pneumatic Safety Valve Status 1 2 13 14 Pressure Switch PS1 Status Pressure Switch PS2 Status 3 15 4 16 5 17 6 18 7 19 8 20 9 21 10 22 11 23 HC Connector in Pneumatic Isolation Module (5)

Section 3 (Cont'd) 7. Use Table 2 to perform a point-to-point continuity check to verify that wiring between the plugs is correct. Table 2 Wiring for Pneumatic Isolation Module Pneumatic Isolation Module Control Module Connector HC Connector Pin Number Connect to Plug Pin Number 1 1 9 2 14 3 6 4 7 5 HP1 15 6 4 7 12 8 5 9 13 10 2 1 10 2 HP2 3 3 11 4 8 16 Pneumatic Safety Valve Status Output, connects to Remote Communication Device if used 17 18 Pressure Switch PS1 Status Output, connects to Remote Communication Device if used 19 20 Ground Terminal on the HC Connector Plug Insert Pressure Switch PS2 Status Output, connects to Remote Communication Device if used HV Ground Terminal Block 8. After continuity check is successfully completed, insert connector plugs HP1 and HP2 into their corresponding ports and connector plug HV into the HV port on the Control Module. Torque the two retention screws on connector HV flanges to 4.5-5.3 lb-in. (0.5-0.6 Nm). 9. Place the HC connector 24-pin insert into the connector hood. Secure the insert with the four attachment screws and torque them to 10.5 lb-in. (1.20 Nm) 10. Plug the HC connector into the bulkhead base on the side of the Pneumatic Isolation Module and latch the two locking levers to secure the hood to the base. 11. Commission the Pneumatic Isolation Module per Chapter 3 of the ElectroGuard User Manual Revision 2030-UM003A-EN-P or later. 42052-111-01 (1) Printed in U.S.A.