SAFETY REASONABLE EFFORT. ANY BINDING, SAGGING, LOOSE HINGES, OR DAMAGED HINGES MUST BE REPAIRED BEFORE CONTINUING WITH THIS INSTALLATION!

Similar documents
Installation Instructions Series 78-B/FHA Hold Open

Electro-Mechanical Swing Operator. Table of Contents

Patriot. Aluminum and Steel 5spring. Step #1 Tarp Spool with Gear Motor (Includes Instructions for Optional Wind Deflector)

Series 9540 J9540. Installation Instructions Multi-Sized 1 to 6 Non-Hold Open. Regular Arm Applications. Parallel Arm Applications

*24828* 1 Installation. Left Hand Shown, Right Hand Opposite. Customer Service

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Connected To Control Box Series. Closer. Set Screw. Arm Screw. Right Hand Shown. 1/8" I.D. Air Inlet Tubing Connected To Control Box

Hunter Automatics HA-8. Installation Manual

Identify and Assemble the Pneumatic Components

Model 2300JL Installation Guide

Model 2300DL Installation Guide

Types P551 and P551A External Closing Spring Retrofit Kits for the Type N550/N551 ESV

4040XPT Series Door controls

Installation, Operation and Maintenance Instructions

ASSA ABLOY Universal Door Closers

4040XP Series Door controls

2300 OPERATING/APPLICATION/INSTALLATION INSTRUCTIONS

4031 Series Door controls

TS93 PT/PTH. Surface applied door closer. Installation instructions: Push side track mount with dead stop (PT) Optional hold open (PTH)

Installation Instructions CAUTION

Chapter 52 DOORS -Title

Automated Steering Hydraulic Installation Kit

Asepsis 21 Delivery Unit

HOW TO TELL HAND OF DOOR:

4840 with EDA arm and 459 Door Loop

Fits AGCO, Challenger, & Massey Ferguson Tractor Models:

Allegion LCN Benchmark AU9100 Series

Instructions for MB832 Manual Barrier Ver0614

INSTALLATION INSTRUCTIONS FOR MODEL H00984

Installation Instructions Models 2858, 2858A-1, 2858GL February 2009

INSTALLATION, MAINTENANCE, & SAFETY INSTRUCTIONS

*24213* 4040-SE Sentronic. 1 Voltage. 6 Adjusting Hold-Open Door Position. 7 Regulation. 2 Tracking. 8 Door Closer Cover.

WARNING! THIS PRODUCT MUST BE INSTALLED BY A TRAINED, AUTHORIZED RICON SERVICE TECHNICIAN.

DC3210 Series. Multi-Sized 1 thru 6 DEEP REVEAL APPLICATION WITH M103 OPTION(615F59 CLAMP KIT) Recommended Closer Size

IOM Manual. IOM Manual. Series 20/21.

1461 Series Door controls

SD Bendix Manual Slack Adjusters DESCRIPTION ADJUSTING MECHANISM OPERATION

ROFU TJ 152-A. Y ALE SECURITY GROUP 50BC Series Door Closer. 50BC Series Door Closers. Sizing Chart for Installations. Ordering Information

Automated Steering Hydraulic Installation Kit

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

Installation, Operation and Maintenance Instructions

Centrifuge Operator / Service Manual

INSTALLATION MANUAL RA-35 & RA-45 M REV. D SEPTEMBER 2017

PNEUMATICS CONTENTS HST-TAMPER

TS9356 PKT 90/119. Surface applied door closer. Installation instructions: Pocket door track mount in 90 /119 pocket (Closer on wall)

Double Acting & Spring Return. SERIES 92/93 Rack & Pinion PNEUMATIC ACTUATOR. The High Performance Company

*24771* 4040SE DE Sentronic. 1 Voltage. 7 Regulation. 2 Track. 8 Door Closer Cover. 3 Spring Power. 4 Arm Installation. 5 Arm Screw.

*28101* 4600 Electronic Low Energy Operator Installation Instructions 4630 PULL SIDE MOUNT 4640 PUSH SIDE MOUNT. Table of Contents.

Carey Automatic Door, LLC OSX ALL AIR (EXPLOSION PROOF) OPERATOR PACKAGES

Installation Instructions (07-08) CAUTION

Hinge (Pull) Side Door Application DC6230 Series Multi-Sized 1 thru 6 DC6430 Series Half-Size 1 thru 6. Door Mounted DC6230 & DC6430

Part# JL AIR IT UP 4 Tire On Board Air Delivery System. (Requires External Air Source)

LAYCOCK SYSTEMS, INC North 43rd Street, Tampa, FL 33605

I-317. AWWA Check Valves WARNING INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES 317 WARNING

Flow Line Controls. Installation & Operations Manual SERIES 20/21 Pneumatic Actuators

Operators Manual ECO-AIR-IVS Internal Valve Actuation System

OPERATION MANUAL. Manual for GW2 2-port and GW3 3-port Dispensers. Java Creations Iced Coffee & Java Works Creamery Classics machines

350 S. St. Charles St. Jasper, In Ph Fax

ASSA ABLOY Universal Door Closers with Heavy Duty Spring Stop Parallel Arms

SENIOR SWING UNIQUE FEATURES

ASSEMBLY & OPERATION INSTRUCTION MANUAL

January Rev. B Rel. 2

*29268* 4600CS Electronic Low Energy Operator 4630CS PULL SIDE MOUNT 4640CS PUSH SIDE MOUNT. Table of Contents. Customer Service

1130 Series Door controls

LCN 7900 SERIES CONTROL BOXES

Type N550 Snappy Joe Emergency Shutoff Valves

Installation Instructions

SURFACE MOUNTED PULL SIDE

The Cyclone Maintenance Manual

materials and workmanship for 2 years. Should the centrifuge require warranty or Phone: or Fax:

The Chameleon Trac II Patent Pending M-Series User s Manual

Actuator Capabilities

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Shipped set to size 3. Standard closer offers 3 installation options. - Regular (Pull side) - Top Jamb (Push side) - Parallel Arm (Push side)

EXTRUDED ALUMINUM TEMPERED GLASS BALANCED DOORS AND ENTRANCES

KAWNEER 1686 EL CONCEALED EXIT DEVICE

INSTRUCTIONS FOR HEAVY DUTY AUTOMATIC STOP COIL WINDING MACHINE CROWN MODELS 2015 & 2016

Trike Conversion Installation Guide Kawasaki Vulcan 900 Classic, Classic LT, and Custom Models 2007 and Up Solid Axle Suspension

WARNING: HARDWARE PACK (A ) DO NOT INSTALL if the truck has been lifted and the stock jounce bumper spacers are not on the vehicle.

Basic Machine Interface Options

5300 Series 5300 SERIES

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V. Extended Capacity Replacement Tank for Diesel Chevrolet / GMC Trucks

1120 Series Door controls

TS93 EMF T/PT/TDE. Surface applied door closer

Standard closer offers 3 installation options. - Regular (Pull side) - Top Jamb (Push side) - Parallel Arm (Push side)

Five Ways to Latch Your Tailgate

9530 Series Senior Swing. Features. Special Templates. Fasteners Mounting. Certifications

Door Controls DOOR CLOSERS

PFadvantage JD 3300/4400/6600/7700; 4420

MC2500. Installation and Operation Manual

92-00 Civic/ Integra/ Del Sol/ Accord/ CRX. Front Kit Part No

hercules Commercial CPL400 CPL600 CPL800 CPL1000 CPL1200 CPL1400 INSTALLATION & OWNER S MANUAL Commercial Vertical Platform Lifts

Industry Insights. Door hardware 101: A basic jargon primer

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

Automated Steering Hydraulic Installation Kit

67-69 Camaro. Hydraulic Clutch Master Cylinder Installation Instructions Read These Instructions Completely Before Beginning

MODEL RF. Drain Cleaning Machine. Operator s Manual

C40008 & C40009 EXHAUST BRAKES

Trike Conversion Installation Guide for Harley-Davidson Sportster Motorcycles 2004 & Up Revision 7

Transcription:

Commercial Gentleman Door Operator Installation Instructions SAFETY THE COMMERCIAL GENTLEMAN IS A LOW ENERGY DOOR OPENER. PROPERLY ADJUSTED, THIS OPENER SHOULD BE EASY TO STOP WITH YOUR LITTLE FINGER. EXCESSIVE OPENING SPEED OR POWER WILL DAMAGE THE "COMMERCIAL GENTLEMAN" AND THE DOOR COMPONENTS. THESE ADJUSTMENTS CANNOT BE MADE AT THE FACTORY AND ARE YOUR RESPONSIBILITY. NOTE: BEFORE INSTALLING THE OPENER, THE DOOR MUST OPEN & CLOSE MANUALLY WITH REASONABLE EFFORT. ANY BINDING, SAGGING, LOOSE HINGES, OR DAMAGED HINGES MUST BE REPAIRED BEFORE CONTINUING WITH THIS INSTALLATION! PLANNING THE INSTALLATION The commercial opener is straightforward to install (Figure 1) and adjust; this document covers the overall installation. GENERAL INFORMATION This opener is pneumatic and requires an air compressor (not included) that will provide 80-100 PSI of air pressure. Multiple openers can operate from a single compressor. If there is an existing system, it may be used if it meets the above criteria. A quiet small tank mounted air compressor located in a remote location is desired. We can recommend a unit based on your installation, please contact GDA if you need assistance at 800-525- 7078. The Commercial Gentleman is comprised of many precision pneumatic controls and requires a clean source of air with minimal moisture. Draining the air compressor tank periodically is essential to eliminate moisture in the air. Please reference Figure 1 for basic installation notes, but read instructions thoroughly. LOCATING THE AIR COMPRESSOR The compressor can be located anywhere up to 125 feet from the opener when only using 5/32 inch tubing. If it is further away than this, a ¼ inch header line will need to be run. The tubing run from the compressor can be either in or out of a conduit; the tubing is durable nylon and can work in any setting or environment. (Figure 1) NOTE: DURING INSTALLATION, DO NOT KINK, PINCH OR CRUSH TUBING. Page 1 of 5

Figure 1 Page 2 of 5

CONTROLLING THE OPENER The switch or controls for your opener may or may not having a timing feature, but most all of the systems use an electric signal to a low voltage solenoid to send compressed air and operate the opener. Unless you are adapting the opener controls to your own system, our control systems are plug-andplay and do not require an electrician. MOUNTING OF THE OPENER Remove the cover from the opener, there are 4 machine screws. NOTE: THE OPENER MOUNTS ON THE PUSH SIDE OF THE DOOR. Use the enclosed template for mounting, but you may need to mount the opener lower for adequate arm clearance. Mount the closer low enough for the opener arm to clear the door frame and door stop during operation. NOTE: A drop down aluminum angle may be necessary to support the opener if it over 1 1/2' below door frame. You may fabricate a support or purchase the support from GDA. 800-525-7078. Secure the opener to the door frame installing the necessary screws in the mounting holes of the closer and through the mounting plate (there are a total of three holes) add more holes and fasteners if necessary. ATTACHING THE CLOSER ARM The main closer arm is the flat metal piece that attaches to the closer. Attach the main closer arm to the closer body using the mounting bolt. The main closer arm should be perpendicular (90 degrees) to the small arm that the actuator is attached to at the top of the closer and air cylinder.(see template) ATTACHING THE SHOE MOUNT TO DOOR The center of the shoe arm is attached 1 ½ below the closer body and 2 from the arm attachment point. See the enclosed template for alignment. Use the necessary fasteners to mount the shoe arm. ATTACHING THE SHOE ARM TO SHOE MOUNT The shoe arm is the section of closer arm that will attach to the shoe mount and connects to the Main arm at an elbow joint. Adjust the length of the shoe arm until it is ½ from the mount. Pull the arm the last ½ to preload the closer to the door and insert the smooth pin and install retaining screw. This preload is sufficient to keep the door closed. Open the door all the way and release it. If necessary, refer to the enclosed closer instructions to adjust the door closer. ADJUSTING THE DOOR OPENER FOR AUTOMATIC OPERATION Once you have the door closing properly, you can connect the air and electric power to the solenoid and adjust it for automatic operation. Page 3 of 5

Figure 2 AIR TUBING CONNECTIONS (FIGURE 2) The compressor fitting will thread into any standard compressor port. Connect the 5/32 line at the compressor connector fitting Run the tubing to the solenoid location and connect into Port 1 on the solenoid On the opposite side of Port 1 is Port 2, connect Port 2 to the opener. NOTE: IF YOU ARE USING THE OPTIONAL LATCH RELEASE, INSTALL TEE INTO THE TUBING BETWEEN PORT 2 AND THE OPENER TO POWER THE LATCH RELEASE. (FIGURE 1) After you have made all airtight connections, activate the compressor and adjust output pressure to 90-100 PSI. You are now ready to adjust the opener. OVERALL SPEED OF THE DOOR The Commercial Gentleman is a low energy door opener; the opening cycle time must be a minimum of 5 seconds. MAIN ADJUSTMENTS REFER TO TEMPLATE CONTROL LOCATIONS Power Adjust the regulator by turning the knob clockwise to increase pressure and counter clockwise to decrease pressure to the opener. If it does not or only opens partially then deactivate the air pressure or wait for the timer to deactivate the system and turn the knob on the regulator another half to full turn. Then activate the system again. Continue to do this until the door opens 90 degrees. Do not worry about the speed of the door opening at this point just that the door opens all the way. If the door slams open, decrease the pressure by turning the knob on the regulator counter clockwise. CAUTION! If the mounting plate is flexing from the wall during operation, the screws are not adequately holding the opener to the wall. Use a longer screw/bolt or drill additional holes in rear plate to secure the opener. Page 4 of 5

Once the door opens properly you can now adjust the speed. Speed adjustment adjust the opening speed by turning the screw on the flow control (on the outflow port of the regulator, see template). Turn in clockwise to slow the door down, turn counter clockwise to speed up the opening. If the door speed is adjusted properly but the door reaches the end of its travel abruptly, adjust the exhaust flow control on the cylinder to cushion door at full open. Exhaust Flow Control Adjustment Adjust the exhaust flow control screw (near cylinder mount, see template) to cushion and decelerate the door as it reaches full open. Closing the valve will slow the door as it moves to full open. Make small adjustments and cycle door until the cushioning effect desired is reached. CAUTION! Never close the exhaust flow control completely! The opener will not function with the flow control fully closed! REINSTALLING CLOSER COVER Install the bottom screws first loosely then install the side screws loosely. Tighten the bottom screws and only tighten the side screws until they touch the cover. NOTE: Do not over tighten the side screws or install them first, this will deflect the cover and cause a misalignment of the bottom screws. INSTALLING A DOOR STOP (!) The opener will be damaged if pressure is applied to open the door further then the opener s maximum swing. Most commercial doors swing out and are also subject to wind damage also. Therefore, a door stop (not included) is recommended to control the door and should be installed so the opener will not exceed full travel. CONTROLLING THE OPENER There are various controllers to activate the Commercial Gentleman. Whether you purchase a control option from GDA or are adapting the unit to the existing system, it simply needs a switch. Basically, the opener operates when power is applied and closes when power is absent. OPTIONAL LATCH RELEASE CYLINDER The pneumatic Latch Release Cylinder installs into the jamb and will depress the door lock latch when the opener is activated. This will unlatch the door knob, even if it is locked, to allow the opener to open the door. OPTIONAL ASSIST CYLINDER (Tee can be located inside opener- Figure 1) If the door requires a higher initial force for magnetic weatherstrip, stack pressure, or electric strike, the assist cylinder kit will overcome these issues. CONGRATULATIONS AND ENJOY YOUR NEW AUTOMATED DOOR! GENTLEMAN DOOR AUTOMATION LLC 109 OLD LIMESTONE RD AVONDALE, PA 19311 (800) 525-7078 gentlemandoor@hotmail.com www.gentlemandoor.com Page 5 of 5