DEWATERING PUMP. Instruction, Installation, Operation and Maintenance Manual. A Mark of Quality. ISO 9001 Certified Company

Similar documents
OPERATION & MAINTENANCE MANUAL POLDER PUMP. A Mark of Quality

Ni-HARD SUBMERSIBLE PUMP

OPERATION & MAINTENANCE MANUAL PORTABLE SUBMERSIBLE PUMP

SUBMERSIBLE SEWAGE PUMP

POLDER PUMPSET. ISO 9001:2008 Certified Company. A Mark of Quality

HORIZONTAL SPLIT CASING PUMP

HORIZONTAL SPLIT CASING PUMP

SUBMERSIBLE SEWAGE AND EFFLUENT PUMPS

H 2. O Series CENTRIFUGAL End-suction Pumps. Versatile, really robust and definitely reliable

PROCESS PUMPS (INDIA) PVT LTD

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE SEWAGE PUMPS TYPE : NS

Installation & Operating Manual

SUBMERSIBLE WATER PUMPS

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Agri KAM INSTALLATION, OPERATION AND MAINTENANCE MANUAL. A View of KBL Dewas Manufacturing Plant. A Kirloskar Group Company KIRLOSKAR BROTHERS LIMITED

PL Submersible, Semi-Vortex, Water Feature Pump

Installation, Maintenance and Operation manual 4 Submersible sand fighter pump. Type: SSFP - Series

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

GD series Submersible Grinder Pump

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

Thank you for selecting the GD submersible grinder pump.

Operating instructions for PXFLOW sewage pumps

SUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2

Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps

Domestic Pumps. Pumps. Self Priming Monoblock Pumps Open Well & Submersible Pumps

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

PROCESS PUMPS (INDIA) PVT LTD

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

Electric Submersible Pumps

GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions

Installation & Operating Manual

INSTALLATION AND OPERATING INSTRUCTIONS

- DIMENSIONS AND WEIGHT 400 PUMP DUMPER 1X SERIES 400 PUMP DUMPER 2X SERIES 401 PUMP DUMPER 3X, 4X, 5X, 6X, 7X, 8X SERIES 402 PACKING 403

SPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

P P 3001 SERVICE INSTRUcTION

B. OTHER SUBMERSIBLE DEWATERING PUMPS

Pump Specifications LE100-Series 1HP Submersible Sewage Pump

SUBMERSIBLE DIRTY WATER PUMP

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Heavy duty slurry pumps

DSZ3. EBARA Submersible Propeller Pumps Contents Project: Model: Chk d: Date: Model

Submersible Tank Pump

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

XLE50 FLOW RATE (LPM) Flow Rate (GPM)

OPERATION & MAINTENANCE INSTRUCTIONS

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

PROCESS PUMPS (INDIA) PVT LTD

Domestic Pumps. Pumps. Self Priming Monoblock Pumps Open Well & Submersible Pumps

Pump Specifications 250 Series Submersible Sump / Effluent Pump

PROCESS PUMPS (INDIA) PVT LTD

NOTE: LEH100-Series high-head pumps require a minimum application of 15' head. Do not use pump in this area use a smaller pump.

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

SUBMERSIBLE WATER PUMP

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

Instruction Manual. * We reserve the right to amend specification without prior notice.

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

Technical Data BEST 2~5. Stainless Steel Submersible Sump Pumps EBARA PUMPS AUSTRALIA PTY. LTD. Best 2-5_Techdata_SS_V10

DUMPER. Data Book 50 Hz

ABS submersible sewage pump AFP

VERTICAL TURBINE PUMP

PUMP. Submersible Sewage Pumps Type DSC4 FEATURES/BENEFITS

Heavy duty slurry pumps

DUMPER. Data Book 50 Hz

Impeller Replacement

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

JDL SYSTEMS Submersible Sump / Sewage Pumps Table of Contents Project: Model: Chk d: Date:

Taro TEXMO INDUSTRIES. 75 mm & 100 mm BOREWELL SUBMERSIBLE PUMPSET PERFORMANCE CHART. Since 1956

SUBMERSIBLE SUMP PUMP RANGE

Taro TEXMO INDUSTRIES SINGLE PHASE JET MONOBLOCS PERFORMANCE CHART. Since 1956

PORTABLE TRASH PUMPS MTP200 MTP300 MTP400

MAINTENANCE CLEANING. MECHANICAL SEAL REPLACEMENT Refer to figures 1 and 2. SHIM ADJUSTMENT

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

OPERATION & MAINTENANCE INSTRUCTIONS

Installation & Operating Manual

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

Taro TEXMO INDUSTRIES. 150 mm BOREWELL SUBMERSIBLE PUMPSET PERFORMANCE CHART. Since 1956

Voltmaster Centrifugal Trash Pumps

Pump Specifications. LE50 Series ½ HP Submersible Sewage Pump

SKHS SERIES 2 HP 1-1/2 HP 1 HP 1/2 HP CAPACITY-U.S. G.P.M.

Pump Specifications LE40 Series 4/10 HP Submersible Sewage Pump Pump

- DIMENSIONS AND WEIGHT 400 PUMP DUMPER 1X SERIES 400 PUMP DUMPER 2X SERIES 401 PUMP DUMPER 3X, 4X, 5X, 6X, 7X, 8X SERIES 402 PACKING 403

XFL70 FLOW RATE (LPM) Flow Rate (GPM)

Instruction Manual. * We reserve the right to amend specification without prior notice.

Dewatering pumps for raw water pumping. / / grundfos DW RANGE

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

PORTABLE TRASH PUMPS MDP200

SUBMERSIBLE SUMP PUMPS

GeyserMax-Flow Series

Dewatering Pump Type DUMPER

DRENOX SUBMERSIBLE SUMP PUMPS FOR DRAINING CLEAR WATER. Usage limitations

Built For Work. THREE-PHASE PUMPS

SUNC3000 / Item #40885

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

Dewatering Submersible sewage pumps

Flygt N-Pumps 3085, 3102 & 3127

HYDROMATIC SKHS SERIES SUBMERSIBLE NON-CLOG, SEWAGE EJECTOR

SECTION 4 - FUEL/LUBRICATION/COOLING

Transcription:

Instruction, Installation, Operation and Maintenance Manual DEWATERING PUMP ISO 9001 Certified Company 2016 mbh pumps (gujarat) pvt. ltd. A Mark of Quality

CROSS SECTION DRAWING INSTALLATION No. DESCRIPTION MATERIAL 1 DELIVERY FLANGE C.I. IS-210, FG-260 2 DISCHARGE OUT LET ALUMINIUM. / C.I. 3 TOP BRG. COVER ALUMINIUM. / C.I. 4 MOTOR BODY ALU./M.S. / S.S. 5 BEARING HOUSING ALUMINIUM. / C.I. 6 PUMP CASING ALUMINIUM. / C.I. 7 GUIDE VANE C.I. IS-210, FG-260 8 IMPELLER C.I. / S.S. 9 NECK RING C.I. IS-210, FG-260 10 BASE ALUMINIUM. / C.I. 11 STAINER S.S. 12 MECH. SEAL LOWER SIC. / SIC. 13 MECH. SEAL UPPER C / Cr. STEEL 14 DRAIN PLUG S.S. 15 0 RING Ni. RUBBER 16 BALL BRG. D.E. - 17 BALL BRG. N.D.E. - 18 ALL PUMP HARDWARE S.S. 19 CABLE GLAND C.I. 20 LIFTING HOOK S.S. 21 CABLE PVC. INSU. SHEATHED 2 3

INTRODUCTION MBH Dewatering Pumps are portable pumping units which have pump below and motor above construction. These are powered by squirrel cage induction motor suitable for 400/440 volts, 3 Phase, 50 Hz, AC supply which is totally enclosed. (and with class f insulation and IP 68 enclosure). The pump motor unit of close coupled construction and the double casing design provides effective water cooling of the motor by following water around the motor casing. The motor is sealed by special Mechanical seal so that the pumping water does not enter the motor chamber and damage the motor. All parts are made from specially selected material and processed to ensure long life under arduous operating condition. RECOMMENDATIONS 1. Follow maintenance schedule strictly, so as to avoid costly repairs in the long run. 2. A good quality motor starter must be used. (Preferably with an ammeter) as it is the life-line of a dewatering pump set. 3. Install the pump on planks or suspend it from a rope a few inches above the bottom surface. If pump thrown down to sump, it might dig in to sludge, resulting in decreased capacity and increased wearing. 4. If water available is falling short of the pump capacity, it will result in spurting, which is harmful for the pump. In such a case reduce discharge by throttling. 5. Ensure that pump rotates in correct condition (clockwise). Counter clockwise rotation results in lower discharge and increased wear. At the instant of starting dewatering, pump should anticlockwise jerk. 6. Observe that the strainer does not get clogged by leaves, suspended material or any other debris. 7. Avoid too many creases in the hose-pipe which results in increased friction losses. Use the shortest possible delivery line. 8. Protect cable from damage-during storage, transportation and operation. A damaged cable may give shock or burn the motor. 9. Always earth the unit, before starting. PRECAUTION FOR LONG STORAGE Clean pump set with fresh water and wipe the cable. Put pump set in cool, dry and shaded place in vertical position and cable wrapped and put on top of the pump. Do not leave cable on the floor where it is likely to get damaged. WARNING Always operate the pump with a reliable motor starter, which must be regularly maintained and properly set. Protect the cable from damage. Ensure that the pump set is earthed, before starting. MAINTENANCE Every 250 hrs. Remove only base, clean impeller & guide vane Every 1000 hr. Examine Sealing arrangement for wear or damage change Sealing chamber oil. No. 01 02 03 SALIENT FEATURES Highlights of Submersible Dewatering Pumps in comparison with Centrifugal Pumps SUBMERSIBLE DEWATERING PUMPS Could completely / partially be submerged in water. Due to high portability, no permanent structure is needed. A simple pit / tank filled with water is quite sufficient and could be discharged with flexible rubber / PVC pipe / M. S. pipe. An absolutely trouble-free compact design pump. CENTRIFUGAL SURFACE PUMPS Not possible, since motor not sealed and is wound with enamelled winding wire. The nature of pump needs permanent structure, suction pipe, foot valve, etc. making it cumbersome. a) Gland leakage, b) Air locking & c) Foot valve choking (clogging) are regular and needs constant attention. 04 Self-priming (submerged). Priming is necessary. 05 Needs no extra man-power. Constant attention is a must. 06 Quite a long life. 07 Here, the impeller is semi-open / closed type and motor portion is completely sealed with mechanical seal. Hence, entering of silt / mud / sand particles / scales etc. is eliminated. Even bearing portion is safe. Particles upto 25 mm size could pass through along with water. Needs regular replacement of parts. Particularly, horizontal pumps need proper alignment and periodical check-up is a must. -- 4 5

Pump fails to deliver The discharge is too low The line current is excessive The total head is too low The power consumption is excessive Noisy operation of pump TROUBLE SHOOTING CHART CAUSE The Pump delivers against an excessively high discharge pressure The Pump and / or piping are incompletely vented Suction line or impeller clogged Reverse Rotation Excessive wear of the pump internals Operating voltage too low The motor is running on two phases only The rotor is out of balance The motor refuses to run because there is no voltage REMEDY Open the isolating valve further, until the duty point conditions have been attained Vent the pump & system completely Remove deposits in the Pump and piping Change over two of the phase leads of the power supply cable Replace worn components by new ones Check the supply terminals inform the supply authorities Replace the defective fuse, check the cable connection Clean the rotor, Rebalance the rotor dynamically Check the electrical system, inform the supply authority Defective motor or cable Please consult our works Defective riser pipe (pipe & gasket) Replace defective lengths or riser pipe by new ones, fit new gaskets Abnormal (excessive) drop in the Please consult our works liquid level during operation The Star-Delta motor remains stuck Check the switchgear / control panel at the star stage during start-up The isolating valve in the discharge Open the valve fully line is not fully open Defective ammeter Replace with new one The insulation resistance of the winding is inadequate (The minimum resistance Please consult our works in warm condition during operation should be 1000 ohms/volt of operating volt) Bearings are damaged in the motor Change the bearings Vibration caused by improper installation Rectify the installation DEWATERING PUMP The Pump is warranty against defects in material and workmanship under normal use and service for the period of 15 months from the date of purchase or 12 months from the date of commissioning whichever is less. The General terms and conditions for above guarantee are : 1. The warranty is valid only if the pump is operated strictly as per the instructions given in the user guide attached herewith. 2. Our obligation is limited to rectifying; repairing or replacing defective items, ex-works / service station / Authorized Service Center, provided the purchaser has given immediate written notice. The equipment for repairs should be returned to us duly packed, on pre-paid freight basis. Model : Customer Name : Address : Date of Purchase / Bill No.: Dealers Name : 6 7 Pump Sr. No. Signature : Date : 14, G.I.D.C. Naroda Indl. Estate, Ahmedabad-382 330, India. Phone : 079-2282 3066 / 2282 1018 E-mail : marketing@mbhpumps.com exports@mbhpumps.com Website : www.mbhpumps.com WARRANTY

OTHER PRODUCTS CENTRIFUGAL BACKPULL OUT PUMP HORIZONTAL SPLIT CASING PUMP SUBMERSIBLE SEWAGE PUMP PORTABLE SUBMERSIBLE PUMP SUBMERGED CENTRIFUGAL PUMP POLDER PUMP ISO 9001 Certified Company 14, G.I.D.C. Naroda Indl. Estate, Ahmedabad-382 330, India. Phone : 079-2282 3066 / 2282 1018 E-mail : marketing@mbhpumps.com exports@mbhpumps.com Website : www.mbhpumps.com A Mark of Quality marg 11/2016 This is the property of