Acuvim-L Series. Multifunction Power Meter. Max & Min

Similar documents
premier product range

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

PQube 3 Modbus Interface

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

EM DC Multi-Function DC Energy Meter

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

OSC is your electric meter expert. When you have questions or need assistance in selecting the proper meter for the job, call us!

Titelgrau belassen! Leere Vorlage

Power Switching Devices

D Series: UPS UPTO - 300KVA - Three / Three Phase

TECHNOLOGICALLY ADVANCED ENERGY PRODUCTS. Product Preview & Price List 2018

ABB n.v Power Quality in LV installations

nonstopower sdn bhd ( P) Power Management Instruments DC Battery Charger / Automation Type RELIABLE SOLUTIONS in POWER ELECTRONICS

A.C. 90 & 240º SCALE AMMETERS & VOLTMETERS

Panel Meters and Accessories Digital Panel Meter

AuCom - Soft Starters

RVS-DN Digital Reduced Voltage Motor Starter

INTECH Micro 2300-RTD6

COUNTIS E22 Three-phase energy meter Direct - 80 A

Three Phase UPS Systems Range: 10 to 500kVA

DGC-2020 DIGITAL GENSET CONTROLLER

Lexium integrated drives

Save Money By Metering Electricity Usage Easily Connect Submeter To Existing WiFi Networks

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

RELIABLE SOLUTIONS in POWER ELECTRONICS. Power Management Instruments RDAT SERIES BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES

RVS-DX Digital Reduced Voltage Motor Starter

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

Power System Measurements. Made in U.S.A. Power Series Plus. Digital Switchboard Meters.

Power Metering. Energy Metering Energy Targeting Energy Monitoring. Product Guide. Innovation by Design. iautomation.com.au

13,000 Watt Diesel Generator AGi13P E

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

ABB central inverters ULTRA-750/1100/ kW to 1560kW

TECHNICAL DATA SHEET KVA UPS Systemss

Instructions for Installation, Operation and Maintenance of Cutler-Hammer IQ DP-4000 Electrical Distribution System Monitor

Electrical network management. Schneider Electric. Acti 9 iem2000 Technical Datasheet

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters

10,000 Watt Diesel Generator AGi9P E

High performance Vector Control. Ratings. System configuration

Industrial PFC UPS System

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Outdoor 200 W 2 Channel SL-L2701B0N1KR

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

PQC - STATCON The ultra fast Power Quality Compensator

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Power System Measurements. Made in U.S.A. Power SeriesP lus. Digital Switchboard Meters.

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

SDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual

Micro Controller based Motor Protection Relay & Motor Management System

University of Houston Master Construction Specifications Insert Project Name

SINGLE-PHASE SOLUTIONS UNINTERRUPTIBLE POWER SYSTEMS

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Testing Energy Storage Systems: From EVs to Utility Grid

Product discontinuation. Notices. Measuring / Motor Protective Relays. Discontinuation Notice of Single-phase Voltage Relay K8AB-VW[].

Digital Time Switches

Galaxy VM. From 160 kva to 1000 kva, 160 kva or 200 kva modular approach. Three-phase power protection

FINHRM FINHRM5 FINHRMA FINHRMAC

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

AGi20P 2.2 L 20 kw Perkins Powered Diesel Generator AURORA GENERATORS INCORPORATED AURORA STANDARD FEATURES STANDBY POWER RATING 20 KW, 20 KVA, 60 HZ.

OPERATING INSTRUCTIONS MCP-MT1

Technical Specification SENTINEL PRO

Data Bulletin. ALTIVAR FLEX58 Chassis Drive Controllers Class 8806 INTRODUCTION DESIGN CONCEPT. Bulletin No. 8806DB0102 August 2001 Raleigh, NC, USA

Chapter 3.1: Electrical System

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

PowerValue 11/31 T kva

OVR Three Phase Recloser 15 kv - 38 kv. Descriptive Bulletin

TC-500PD8. Switching Power Supply ( PS2 A T X 500W 8 0+ ) SPECIFICATION. Revision: 2.0

MKN-DSP SERIES - THREE PHASE

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

MD60 Series 60W DINergy Power Supply

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

EG1299. Variable Speed Engine Controller for Telecom Backup Gensets SEDEMAC EG1299 HIGHLIGHTS

Liebert. FP 50Z kva

SST-ST75F-ESS The essential silver standard

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

POWERTRONIX QUASAR 5-40 KVA

Low voltage AC drives

Aurora Single Phase Emergency Lighting Inverters

Data sheet MULTICAL 6L2. Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434

ANSI Switchboard Meters

Galaxy VM. From 160 kva to 1000 kva Three-phase power protection. apc.com/products

AC Wattmeters and VArmeters

Southern Company Interconnection Process. Dexter Lewis Research Engineer Research and Technology Management

Power IT LV Active Filters PQFI - PQFM PQFK - PQFS

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Magellan Utility Scale Energy Storage

Residential Energy Storage System SH 5K

Test&Measurement. Power Series Plus. Digital Switchboard Meters

ALPHA S NEXT-GENERATION UNINTERRUPTIBLE POWER SUPPLY

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Description 1/8-7.5HP

Transcription:

Series Multifunction Power Meter TRUE-RMS MEASURING OVER/UNDER LIMIT ALARM Max & Min MAX & MIN RECORD POWER QUALITY ANALYSIS TOU, 4 TARIFFS, 12 SEASONS 14 SCHEDULES Metering of Distribution Feeders, Transformers, Generators, Capacitor Banks and Motors Medium and Low Voltage Systems Commercial, Industrial, Utility Power Quality Analysis ISO9001 Certified

UL & cul Certified The front panel protection level is IP54 Active power accuracy is 0.5s Powerful power quality analysis DESCRIPTION The series are multifunction power meters manufactured by Accuenergy. It is the ideal choice for monitoring and controlling of power distribution system. Some of the features and electric power parameters available on the are: True-RMS Measuring Parameter 4-quadrant Energy Power Quality Analysis Over/Under Limit Alarm Energy Pulse Output TOU, 4 Tariffs, 12 Seasons, 14 Schedules may be used as a data gathering device for an intelligent Power Distribution System or a Plant Automation System. All monitoring data is available via digital RS485 communication port running Modbus Protocol. The quality of the power system is important with increasing use of electronic loads such as computers, ballasts or variable frequency drives. With the power analysis option, any phase current or voltage can be displayed and the harmonic content calculated. By knowing the harmonic distribution, action can be taken to prevent overheated transformers, motors, capacitors, neutral wires and nuisance breaker trips. Redistribution of the system loading can also be determined. APPLICATIONS Metering of distribution feeders, transformers, generators, capacitor banks and motors Medium and low voltage systems Commercial, industrial, utility Power quality analysis FEATURES Metering Voltage: Uln 1, Uln 2, Uln 3, Uln avg, Ull 12, Ull 23, Ull 31, Ull avg Current: I1, I2, I3, In, I tot, I avg Active Power: watt 1, watt 2, watt 3, watt tot Reactive Power: var 1, var 2, var 3, var tot Apparent Power: va 1, va 2, va 3, va tot Power Factor: PF1, PF2, PF3, PF Frequency: F Active Energy: Watt-hour Imp, Watt-hour Exp, Watt-hour Imp+Exp, Watt-hour Imp-Exp, Watthour Q1, Watt-hour Q2, Watt-hour Q3, Watt-hour Q4, Watt-hour Imp 1, Watt-hour Exp 1, Watt-hour Imp 2, Watt-hour Exp 2, Watt-hour Imp 3, Watthour Exp 3 Reactive Energy: Var-hour Imp, Var-hour Exp, Var-hour Imp+Exp, Var-hour Imp-Exp, Var-hour Q1, Var-hour Q2, Var-hour Q3, Var-hour Q4, Varhour Imp 1, Var-hour Exp 1, Var-hour Imp 2, Varhour Exp 2, Var-hour Imp 3, Var-hour Exp 3 Apparent Energy: VA-hour Imp, VA-hour Exp, VAhour Imp+Exp, VA-hour Imp-Exp, VA-hour Q1, VAhour Q2, VA-hour Q3, VA-hour Q4, VA-hour Imp 1, VA-hour Exp 1, VA-hour Imp 2, VA-hour Exp 2, VAhour Imp 3, VA-hour Exp 3 Current Demand: I1_Dmd, I2_Dmd, I3_Dmd, IN_ Dmd, I1_Pre_Dmd, I2_Pre_ Dmd, I3_Pre_Dmd, IN_Pre_Dmd Power Demand: P_Dmd, Q_Dmd, S_Dmd, P_ Pre_Dmd, Q_Pre_Dmd, S_Pre_Dmd Load Features Four Quadrant Powers Monitoring Power Quality Voltage Harmonics 2 nd ~31 st for AL, BL and CL; 2 nd ~63 rd for DL and EL Current Harmonics 2 nd ~31 st for AL, BL and CL; 2 nd ~63 rd for DL and EL Voltage Unbalance Factor U_unbl Current Unbalance Factor I_unbl Max/Min Statistics Meter Running Time and Load Running Time Alarm Two (2) parameters may be set within a specified time interval. If indicated parameter is over or under its setting limit and persists over the specified time interval, the event will be recorded with time stamps and trigger the alarm DO output. The indicated parameter can be selected from any of the 50 parameters available. I/O option module The Acuvim-CL/DL/EL model can extend the I/O module. Digital input, pulse counter, pulse output and SOE can provided by extention I/O module. Pulse Output option Two digital outputs can be configured as pulse output for kwh and kvarh.the pulse rate and width can be set. Anti-tampering Seal Users can physically seal the meter similar to a utility meter in order to provide anti-tampering protection. All metrological programming and user- defined parameters are protected with a physical seal. Power Quality Event Logging When a power quality event happens, such as voltage sag and fail, etc., Acuvim-Dl/EL will record the timestamp and the triggering condition of the event. It can save 16 power quality events. Time of Use Users can assign up to 4 different tariffs (sharp, peak, valley and normal) to different time periods within a day according to the billing requirements. The Acuvim-EL meter will calculate and accumulate energy to different tariffs according to the meter s internal clock timing and TOU settings. Flexible Current Input Compatible with different current transformers such as 5A, 1A, 80mA, 100mA, 200mA, 333mV output CT and Rogowski coil all available from Accuenergy. Wiring Check The Acuvim - L series meter has the function of wiring check, according to the setting of wiring mode, load features and PF value. Communication RS485, industry standard Modbus RTU protocol; Options are the second RS485 module, PROFlBUS- DP/VO module.

FUNCTION LIST Function Option Blank NA REAL TIME METERING ENERGY DEMAND Function Parameter Acuvim-AL Acuvim-BL Acuvim-CL Acuvim-DL Acuvim-EL Acuvim-KL Line to Neutral Voltages Uln Uln 1, Uln 2, Uln 3, Uln avg Line to Line Voltages Ull Current Active Power Reactive Power Apparent Power Power Factor Load Nature Frequency Active Energy Reactive Energy Apparent Energy Single-Phase Active Energy Single-Phase Reactive Energy Single-Phase Apparent Energy Current Demand, Current Predicted Demand Power Demand, Power Predicted Demand Ull 12, Ull 23, Ull 31, Ull avg I 1, I 2, I 3, I n, I avg, I tot watt 1, watt 2, watt 3, watt tot var 1, var 2, var 3, var tot va 1, va 2, va 3, va tot PF 1, PF 2, PF 3, PF L/C/R F Watt-hour Imp, Watt-hour Exp, Watt-hour Imp+Exp, Watt-hour Imp-Exp Watt-hour Q1, Watt-hour Q2, Watt-hour Q3, Watt-hour Q4 Var-hour Imp, Var-hour Exp, Var-hour Imp+Exp, Var-hour Imp-Exp Var-hour Q1, Var-hour Q2, Var-hour Q3, Varhour Q4 VA-hour Imp, VA-hour Exp, VA-hour Imp+Exp, VA-hour Imp-Exp VA-hour Q1, VA-hour Q2, VA-hour Q3, VAhour Q4 Watt-hour Imp 1, Watt-hour Exp 1, Watthour Imp 2, Watt-hour Exp 2, Watt-hour Imp 3, Watt-hour Exp 3 Var-hour Imp 1, Var-hour Exp 1, Var-hour Imp 2, Var-hour Exp 2, Var-hour Imp 3, Varhour Exp 3 VA-hour Imp 1, VA-hour Exp 1, VA-hour Imp 2, VA-hour Exp 2, VA-hour Imp 3, VA-hour Exp 3 I 1_Dmd, I 2_Dmd, I 3_Dmd, I N_Dmd, I 1_ Pre_Dmd, I 2_Pre_ Dmd, I 3_Pre_Dmd, I N_ Pre_Dmd P_Dmd, Q_Dmd, S_Dmd, P_Pre_Dmd, Q_ Pre_Dmd, S_Pre_Dmd TIME Real Time Clock Year, Month, Date, Hour, Minute, Second HOUR Meter Running Time Hour Load Running Time Hour WIRING CHECK Voltage/Current Wiring Each phase of V & I loss or error Voltage Unbalance U_unbl Current Unbalance I_unbl Voltage THD THD_U 1, THD_U 2, THD_U 3 Current THD THD_I 1, THD_I 2, THD_I 3, THD_IN POWER QUALITY Individual Harmonics Harmonics 2 nd to 31 st Harmonics 2 nd to 63 rd Voltage Crest Factor Crest Factor TIF THFF Current K Factor K Factor SEQUENCE Voltage/Current Sequence Positive Sequence, Negative Sequence, Zero Sequence PHASE ANGLES Voltage/Current Phase Angles Voltage Phase Angle, Current Phase Angle STATISTICS ALARM POWER QUALITY EVENT LOGGING TIME OF USE I/O COMMUNICATION MAX with Time Stamp, MIN with Time Stamp Over/Under Limit Alarm Power Quality Event with Time Stamp Energy/Max Demand DAYLIGHT SAVING TIME Holiday Energy Pulse Output IO Module RS-485 RS-485 Module PROFIBUS Each phase of V & I; Total of P, Q, S, PF & F; Demand of I1, I2, I3, IN, P, Q&S; Each phase THD of V & I; Unbalance factor of V & I V, I, P, Q, S, PF, V_THD & I_THD Each Phase and Total or Average; Unbalance Factor of V& I; Load Type; Demand of I1, I2, I3, IN,P, Q&S; Reverse phase sequence; Voltage SAG and fail, Current overflow, Phase Sequence error TOU, 4 Tariffs, 12 Seasons, 14 Schedules Two Adjustable Formats Holiday setting up to 10 years 2 DO, configured as pulse output for kwh and kvarh, the pulse rate and width can be set 4DI, 2DO/2RO, SOE, Pulse Counter, Pulse output, Alarm output Modbus -RTU Protocol Modbus -RTU Protocol PROFIBUS-DP/V0 Protocol

TYPICAL WIRING A B C N A B C A B C N 1 I11 10 9 8 7 5 I31 3 Phase 4 Wire (Wiring: 3LN, 3CT; IN: Measured) 1 I11 10 9 8 7 5 I31 3 Phase 3 Wire (Wiring: 3LL, 3CT) 1 I11 10 9 8 7 5 I31 3 Phase 4 Wire (Wiring: 3LN, 3CT; IN: Calculated ) A B C 1 I11 5 I31 10 9 8 7 3 Phase 3 Wire (Wiring: 2LL, 3CT) 11 12 13 L/+ N/ Power Supply 14 15 16 A B S RS485 Communication 100~415Vac, 50/60Hz 100~300Vdc Power Supply+Communication S S 11 12 13 L/+ N/ Power Supply 14 15 16 DO1 DO2 DOC Energy Pulse Output Vaux + 100~415Vac, 50/60Hz 100~300Vdc Pulse Output Power Supply+Energy Pulse Output (DO) # I/O Module, DI, RO/DO Wiring Diagram Note: "#" Wiring diagram is only applicable to Acuvim BL.

SPECIFICATIONS METERING Parameters Accuracy Resolution Range Voltage 0.5% 0.1V 20V~1000kV Current 0.5% 0.001A 0~50000A Current Demand 0.5% 0.001A 0~50000A Power 0.5% 1W -9999MW~9999MW Reactive Power 0.5% 1var -9999Mvar~9999Mvar Apparent Power 0.5% 1VA 0~9999MVA Power Demand 0.5% 1W -9999MW~9999MW Reactive Power Demand 0.5% 1var -9999Mvar~9999Mvar Apparent Power Demand 0.5% 1VA 0~9999MVA Power Factor 0.5% 0.001-1.0~1.0 Frequency 0.2% 0.01Hz 45.00~65.00Hz Energy 0.5% 0.1kWh 0~99999999.9kWh Reactive Energy 0.5% 0.1kvarh 0~99999999.9kvarh Apparent Energy 0.5% 0.1VAh 0~99999999.9kVAh Harmonics 1.0% 0.01% Meter Running Time 0.01hrs 0~9999999.99hrs Load Running Time 0.01hrs 0~9999999.99hrs Meter Total Running Time 0.01hrs 0~9999999.99hrs INPUT Current Inputs (Each Channel) Nominal Current 15A, 21A, 31A(333mV), 41A(100mV Rope - CT), 51A(80mA/100mA/200mA), 61A(6.68mA) Metering Range 10~10A, 20~2A, 30~1.2A, 40~1.2A, 50~1.2A, 60~1.2A Pickup Current 15mA, 21mA, 35mA, 45mA, 55mA, 65mA Withstand 20Arms continuous 100Arms for 1 second, non-recurring Burden 0.05VA (typical) @ 5Arms Accuracy 0.5% Voltage Inputs (Each Channel) Nominal Full Scale 400Vac L-N, 690Vac L-L (+20%) Withstand 1500Vac continuous 2500Vac, 50/60Hz for 1minute Input Impedance 2Mohm per phase Metering Frequency 45Hz~65Hz Pickup Voltage 10Vac Accuracy 0.5% Energy Accuracy Active (according to IEC 62053-22) Class 0.5s (according to ANSI C12.20) Class 0.5s Reactive (according to IEC 62053-23) Class 2 Harmonic Resolution Metered Value 2 nd ~63 rd harmonics Digital Output (DO) Voltage Range Load Current Output Frequency (Max) Isolation Voltage COMMUNICATION RS-485 (Optional) Modbus -RTU Protocol 2-wire connection, Half-duplex, Isolated 1200 to 38400 baud rate Sencond RS485 (Acuvim-CL, Acuvim-DL and Acuvim-EL can optional) PROFI-BUS (Optional) PROFIBUS-DP/V0 Protocol Work as PROFIBUS slave, baud rate adaptive, up to 12M Typical input bytes: 32, typical output bytes: 32 PROFIBUS standard according to EN 50170 vol.2 Operation Temperature Storage Temperature Relative Humidity Pollution Degree Digital Output OPTION (Photo-MOS) 0~250Vac/dc 100mA (Max) 25Hz, 50% Duty Ratio 2500V CONTROL POWER Universal AC or DC AC/DC Control Power Operating Range 100~415Vac, 50/60Hz, 100~300Vdc Burden Withstand 3250Vac, 50/60Hz for 1 minute Low Voltage DC Control Power (Optional) Operating Range 20~60Vdc Burden Measurement Standard Environmental Standard Safety Standard EMC Standard Outlines Standard OPERATING ENVIRONMENT - 25ºC to 70ºC - 40ºC to 85ºC 5% to 95% non-condensing 2 STANDARD COMPLIANCE IEC 62053-22 Class 0.5S, 62053-23 Class 2 IEC 60068-2 IEC 61010-1, UL 61010-1, IEC 61557-12 IEC 61000-4/-2/3/4/5/6/8/11, CISPR 22, IEC 61000-3-2, IEC 61000-6-2/4 DIN 43700/ANSI C39.1 Digital Input (DI) Input Type Input Resistance Pulse Frequency (Max) SOE Resolution Digital Intput OPTION Dry Contact 4kΩ 100Hz, 50% Duty Ratio 2ms

DIMENSIONS 7.60 (0.300) Unit: mm (inches) Unit: mm (inches) Multifunction Power Meter Extend Module Dimensions 91.00 (3.583) 91.00 (3.583) 35.50 (1.398) 91.00 (3.583) 90.00 (3.543) H P E V/A 35.90 (1.413) 50.70 (1.996) 35.90 (1.413) 50.70 (1.996) 14.00 (0.551) 35.90 (1.413) 10.00 (0.394) 55.60 (2.189) 19.50 (0.768) Front View of the Display Meter and Remote Display Unit Side View of the Display Meter Side View of the DIN rail Meter Side View of the Remote Display Unit 102.00 (4.016) Profibus Module Dimensions 90.00 (3.543) 92.00 (3.622) Cut-Out Cut-Out 55.60 (2.189) 92.00 (3.622) 22.00 (0.866) Rear View Rear View of the Remote Display Unit Cut Out Note: 1. The cable length connecting the Remote Display Unit and the DIN Rail Meter is 2 metres (6 feet). Contact your customer service rep if you require a longer cable. 2. The Remote Display Unit and Display Meter have the same cutout. ORDERING INFORMATION Acuvim- L Mounting Current Power Supply Extended Module * Remote Display Option X1: 4DI+2DO X2: 4DI+2DO+Second RS485 X3: Profibus X4: 4DI+2DO+Profibus X5: 4DI+2RO X6: 4DI+2RO+Second RS485 REM - DS1: Compatible with Series M (DIN Mount) models only Remote Display Option Ordering Example: REM - DS1 P1: 100~415Vac, 50~60Hz 100~300Vdc P2: 20~60Vdc 5A: 5Amp 1A: 1Amp 333: 333mV input 200: 80/100/200mA input 100: 100mV Rope-CT input 6.68: 6.68mA input D: Standard with LCD Display M: DIN rail mount (optional Remote Display to be added) A: Acuvim-AL (Basic) B: Acuvim-BL (Basic + DO) C: Acuvim-CL (Basic + COMM + IO) D: Acuvim-DL (Basic + COMM + IO) E: Acuvim-EL (TOU + COMM + IO) K: Acuvim-KL (ABRIDGED) Series Meter Ordering Example: Acuvim-EL - D - 5A - P1 - X2 * Note: 1. Extended Modules only supported by the Acuvim-CL, the Acuvim-DL and Acuvim-EL models. 2. Profibus module must be installed on the back of the meter FLRST before the other module is attached. 3.Using Rope-CT as current transformer, not support the IN, WIRING CHECK, POWER QUALITY, SEQUENCE,PHASE ANGLES and POWER QUALITY EVENT LOGGING function. Accuenergy Corporation Los Angeles-Toronto-Beijing North America Toll Free: 1-877-721-8908 Web: www.accuenergy.com Email: marketing@accuenergy.com Revision Date: Nov., 2016 Document #1030E1304