Ceiling Swirl Diffuser DQJ

Similar documents
ceiling swirl diffuser DQJ

Swirl Diffuser Model DQF

Ceiling diffuser 4DE

Ceiling impulse diffuser Model PIL

ceiling swirl diffuser Model DQJA / DQJR

Ceiling diffuser 4DF

Swirl Diffuser DHV Contents Description...3 Models and dimensions...4 Technical data...8

WGA Long throw nozzle grille

Ventilation grille Model AL

Ceiling Slot Diffuser DSC

Ceiling Slot Diffuser DSC

Ceiling Slot Diffuser DSC

Ceiling Slot Diffuser Model DSX

Nozzle Jet Diffuser Model DSA

Long Throw Nozzle WDA

Ventilation grille Model IB-R

Ventilation Grille PA

Round duct grille Model KG-RR

Compact Grille Model KG

Lint separator FLARE

Round duct diffuser DBB-RR

LAQ Return air diffuser

Air diffuser system Model AUDIX -AW

Particle Filter Box FKU

DSC-PLASTER Slot diffuser for plasterboard ceilings

Particle Filter Box Model FKF

Ceiling induction diffuser DISA-300

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Ceiling induction diffuser DISA-601

Ceiling swirl diffusers

Mechanical mixing box MBM

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers with perforated face plate

Volumetric Flow Limiter VOLKOM

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Technical documentation

Slot diffusers, Round duct diffusers. IMP Klima

Catalog Swirl diffuser DAL 358

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Ceiling swirl diffusers

Ventilation grilles for installation into walls, sills or rectangular

Round Duct System Model RR-Complete

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Round Duct System Model RR-Complete

Slot diffusers for ceiling installation

Ceiling swirl diffusers

Krantz. Floor displacement outlet Q-B-DN 200. Air distribution systems

Catalog Swirl diffuser DAL 359

Ventilation grilles for installation into walls, sills or rectangular

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

C O L M A N. Air Distribution CIRCULAR DIFFUSERS LRS SERIES LRS SERIES

Ceiling air diffuser INDULCLIP INDUDRALL KOMBICLIP

Type VSD35. Nominal length up to 1500 mm: one spigot

C O L M A N. Air Distribution FLOOR SWIRL DIFFUSERS B SERIES SERIES

IMP Klima. Swirl diffusers. Variable swirl diffusers

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

C O L M A N. Air Distribution SWIRL DIFFUSERS DWT SERIES DWT SERIES

Fan coil unit NBS 100/150

Multicore diffusers. introduction. type control. options. finish. sizes SQUARE AND RECTANGULAR DIFFUSERS

SLOT DIFFUSERS, ROUND DUCT DIFFUSERS

Air Distribution SWIRL DIFFUSERS DW SERIES SERIES

DRUM SLOT DIFFUSER TYPE: RT350

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

NTK floor twist outlet DB-N-DN 215

LINEAR SLOT DIFFUSERS

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

Catalog Linear Diffuser SAL 50

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

ACTIVENT System. Specifications. Product code example ACTA

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

WALL VENTILATION GRILLES CBP

series Linear grilles

Wall and Ceiling Grille

HIGH CAPACITY LINEAR SLOT DUFFUSERS

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

Air Displacement Vent Units

Active Chilled Beams

Round Duct System Accessories RR - accessories

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

Active Chilled Beams

CNVA TECHNICAL DOCUMENTATION. Active floor convector. Contents

series KFD-KLD Linear slot diffusers

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

DRUM JET DIFFUSERS TYPE: DJA DJB DJAP DJBP

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face

SRY. Ceiling mounted linear disc diffuser for supply air QUICK FACTS

LINEAR SLOT DIFFUSERS

ISF-AD. Inclined Floor Swirl Diffuser PRODUCT BROCHURE. Optional Features: Constant throw height adjustable airflow rate Electrical VAV operation

Weather protection grille ALAS

Transcription:

Ceiling Swirl Diffuser DQJ Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de

contents Description...3 Advantages... 3 Blade adjustments... 4 Construction... 4 Model... 4 Accessories... 5 Fastening... 5 Models and dimensions...6 Throw pattern... 6 Special model... 9 Special blade settings... 9 Dimensions... 10 Dimensions of accessories... 13 Fastening methods... 17 Installation... 18 Technical Data... 19 Pressure loss and noise level... 19 Maximum end velocity of jet... 27 Critical throw... 34 Maximum penetration... 36 Induction ratio... 39 Temperature ratio... 40 Legend... 41 Order details... 42 Order details of accessories... 43 Specification texts... 44 05/01-2

Description The ceiling swirl diffuser type DQJA-SR / DQJA-SQ / DQJB / DQJR is particularly suitable for installation in comfort rooms with high air change rates. Unlike the conventional swirl diffusers, the air deflection blades can also be adjusted at a later stage. This may become necessary if there are obstacles in the air jet path. The diagrams clearly show the influence the blade position has on the radial propagation of the jet. The blades can be adjusted to achieve throw patterns from horizontal to vertical. This can be important, for example, if the air jet is to be directed toward a specific point where high heat loads are present. In difficult cases, the position of the blades can be determined by carrying out flow tests at the SCHAKO laboratory. Various air jet guide postions can be manufacturer preset. Air throw "B" is set in the factory unless specified otherwise in the order. The air diffuser is particularly suitable for installations with variable volumetric flow. A stable jet pattern is guaranteed by the high exit velocity. Even at a low volumetric flow the jet does not sink abruptly from the ceiling. If the "critical throw" x kr (m) parameter is smaller than the "horizontal throw" x (m) parameter for your model, then the calculation for the maximum end velocity of jet V max (m/s) is based on the "critical throw" x kr and not on the "horizontal throw" x (m) parameter. A plenum box with fixing lugs can be fitted to the ceiling swirl diffuser (-SAK for DQJA-SR... / DQJA-SQ / DQJB, SRK for DQJR-SR-...). The supply air diffuser model has two straightening grids, for return air the model is painted inside to RAL 9005 (black) as standard. In addition, the plenum box can be fitted (at an extra charge) with various components such as throttle damper (-DK), volumetric flow meter (-VME), ROB version(-rob) and rubber lip seal (-GD). The throttle damper (-DK) at the connection piece is for air volume regulation and adjustable from below (only DQJA-SR / DQJA-SQ / DQJB). For plenum boxes SAK, the damper (-DK) can be mounted on the room side with mounted diffuser. For plenum boxes SRK, the ceiling diffuser must be removed, before the damper can adjusted. Alternatively, a cable-operated adjustment (-SZV) can be attached, which allows the damper (-DK) to be adjusted on the room side even with mounted diffuser. In the connection piece of the plenum box, a volumetric flow meter (-VME) can be integrated. The measurement error of the volumetric flow meter is ± 5 % at a connecting piece velocity of 2-5 m/s and a straight flow pattern of at least 1 x D. The measurement is carried out with integrated diffuser. By adjusting the throttle damper, the required air volume of each diffuser can be set quickly and correctly. To allow duct cleaning robots to be inserted from the room side, the distribution sheet in the ROB version (-ROB) can be removed as well as the damper and the volumetric flow meter (if integrated). Other accessories (at an extra charge) are hit-and-miss damper (-SS-K, only for DQJA-SR / DQJA-SR-PS-Z / DQJA-SQ) for air volume regulation, ball impact guard (-BS, only for DQJA-SR / DQJA-SR-PS-Z / DQJA-SQ / DQJB), motor adjustment (-MV only for DQJA-SR / DQJA-SR-PS-Z sizes 500-800, activated via AGV-3), 1/4 cover (-AD, only for supply air version) and adjustable damper (-DV, only for DQJR-SR / DQJR-SR-PS-Z). TÜV SÜD has successfully inspected the ceiling swirl diffuser DQJ according to the following rules: - VDI 6022, Sheet 1: Hygienic requirements of ventilation and air-conditioning systems - VDI 6022, Sheet 2: Hygienic requirements of ventilation and air-conditioning systems - Measurement methods and investigations during hygienic controls and hygienic inspections. - DIN 1946, Sheet 2: Air-conditioning technology - Health requirements For mounting in the ceiling, inspection openings for the electrical connection must be provided on-site in sufficient number and size. Advantages - A subsequent adjustment of the blades on-site in the built-in state is also possible. - Noise level and pressure loss remain constant in all blade positions. - High induction ensures very good reduction of the velocity and the temperature difference. - Stable air jet even at reduced air volumes - Volumetric flow meter 05/01-3

Blade adjustments Pages 5-8 in the catalogue clearly show the extreme adjustment flexibility of the DQJA-SR / SQ ceiling swirl diffusers. It may become necessary to adjust the position of the blades if, after installation, there are obstacles too close to the diffuser obstructing the air flow, for example columns or cupboards. The "two-way throw" version is ideal for corridors. This avoids any deflection from the wall down to the occupied zones. The diffuser is preset by the manufacturer to air throw "B" as a standard feature unless specified otherwise when ordering. For size 310, the only air throw available is "A". The air throw patterns can be easily changed at a later stage on-site, even with the diffuser installed, without using any special tools. The pressure loss and the noise level remain constant in all blade positions. Construction Faceplate - Painted sheet steel RAL 9010 (white, standard) or RAL 9005 (black) - Sheet steel painted to a different RAL colour. - Stainless steel (V2A) painted in sand silver - Natural colour anodised aluminium (E6/EV1) (only available with VM mounting) Blades - Plastic, RAL 9010 (white) or RAL 9005 (black, standard) - Aluminium painted to the RAL colour of the faceplate (blades cannot be adjusted subsequently) Blade fixing - painted sheet steel, front plate made of stainless steel Blade holder - Aluminium ducts Pole brace fastening - Plastic Pole brace fastening - Galvanised sheet steel VM pole brace - Model DQJA-SR - with square face plate, circular blade pattern, standard screw mounting (-SM) DQJA-SR-PS-Z - as DQJA-SR, but with continuous blades (only for supply air), standard with screw mounting (-SM). DQJA-SQ - with square faceplate, square blade pattern, standard with screw mounting (-SM) DQJR-SR - with round faceplate, circular blade pattern, standard with concealed mounting (- VM) DQJR-SR-PS-Z - as DQJR-SR, but with continuous blades (for supply air only), standard with concealed mounting (VM) DQJB-T70/T150 - with square faceplate, offset by 70 / 150 mm, circular blade pattern, standard with screw mounting (-SM) DQJ...-...-Z - for supply air, without air deflection blades DQJ...-...-A - for return air without air deflection blades 05/01-4

Accessories Plenum box (-SAK) - for DQJA-SR / DQJA-SR-PS-Z / DQJA-SQ / DQJB - Galvanised sheet steel housing - VM pole brace made of aluminium - VM mounting made of plastic Plenum box (-SRK) - for DQJR-SR / DQJR-SR-PS-Z - Galvanised sheet steel housing - VM pole brace made of aluminium - VM mounting made of plastic Throttle damper (-DK) - in the plenum box SAK / SRK - Throttle damper made of galvanised sheet steel - Damper fastening made of plastic - with cable-operated adjustment (-SZV) (at an extra charge, only for SRK) Volumetric flow meter (-VME) - in the plenum box SAK /SRK at the connection piece - Mounting made of galvanised sheet steel - Measuring sensor made of plastic - Aluminium connections ROB version (-ROB) - in the plenum box SAK / SRK - Removable diffuser plate, damper and volumetric flow meter Rubber lip seal (-GD) - in the plenum box SAK /SRK at the connection piece - Special rubber Hit-and-miss damper (SS-K) - only possible for DQJA-SR / DQJA-SR-PS-Z / DQJA-SQ - Electrolytically galvanised sheet steel frame - Electrolytically galvanised sheet steel damper - Galvanised spring steel damper fixing Ball-impact guard (-BS) - only possible for DQJA-SR / DQJA-SR-PS-Z / DQJA-SQ with screw mounting (-SM) and for size 800 only with screw mounting (SM-V). - Steel painted to RAL 9010 (white), other RAL colours possible at an extra charge. Motor adjustment (-MV) - only DQJA-SR-PS-Z sizes 500-800 with screw mounting (-SM) möglich - Galvanised sheet steel ring - Plastic blade adjuster - Brass adjustment 1/4 cover plate (-AD) - only supply air version possible - Galvanised sheet steel Damper (-DV) - only possible for DQJR-SR / DQJR-SR-PS-Z with screw mounting (-SM) - Galvanised sheet steel damper plate - Aluminium plate fixing - Galvanised sheet steel fixing screw - Galvanised sheet steel casing Internal insulation (-Ii) - Thermal insulation inside the plenum box External insulation (-Ia) - Thermal insulation on the outside of the plenum box Fastening Screw mounting (-SM) - with 4 on-site shallow-raised, countersunk-tapping head screws, standard for version DQJA-... and DQJB-... (not possible for size 800, without motor adjustment), standard for DQJA-SR-PS-Z-MV 800 (with motor adjustment). Concealed mounting (-VM) - The pole brace fastening (at an extre charge) is only available in connection with the plenum box (standard for the version DQJR-..., standard for size 800 with DQJA-... and DQJB-...). Central mounting (-MM) - Central mounting for the versions DQJA-SR-Z and DQJA- SR-PS-Z up to size 625 Screw mounting with concealed mounting (-SM-V) - Screw mounting (-SM) in combination with concealed mounting (-VM) - only possible for size 800 in conjunction with ball-impact guard (-BS) Attention! We would like to point out that only suitable cleaning materials may be used for cleaning the stainless steel design! 05/01-5

Models and dimensions Throw pattern Blade adjustment options and screw mounting (SM) Throw pattern: "A" : all blades in position 2 Throw pattern: "B" : blades in positions 1+2, preset by manufacturer - The ceiling swirl diffuser of size 310 is only available with air throw "A". - DQJB only available from size 400 upwards. - DQJR-SR / DQJR-SR-PS-Z with screw mounting (-SM) only available without plenum box, as a standard feature, this design is with concealed mounting (-VM)! - Size 310 with indentation for slotted shallow-raised countersunkhead tapping screw DIN ISO 7051 pitch 3.9 (on-site) Sizes 400-625 with indentation for slotted shallow-raised countersunk-head tapping screw DIN ISO 7051 pitch 4.8 (on-site) Size 800 is only available in concealed mounting (exception: DQJA-SR-PS-Z-MV)! Air throw pattern "B" Blade position 1 (-L1) Blade position 2 (-L2) NW 310 (only available with throw pattern A ) DQJA-SR-Z 310 DQJA-SR-PS-Z 310 DQJA-SQ-Z 310 DQJR-SR-Z 310 DQJR-SR-PS-Z 310 DQJB-Z 310 not available! Size 400 DQJA-SR-Z 400 DQJA-SR-PS-Z 400 DQJA-SQ-Z 400 DQJR-SR-Z 400 DQJR-SR-PS-Z 400 DQJB-Z 400 05/01-6

Size 500 DQJA-SR-Z 500 DQJA-SR-PS-Z 500 DQJA-SQ-Z 500 DQJR-SR-Z 500 DQJR-SR-PS-Z 500 DQJB-Z 500 Size 600 DQJA-SR-Z 600 DQJA-SR-PS-Z 600 DQJA-SQ-Z 600 DQJR-SR-Z 600 DQJR-SR-PS-Z 600 DQJB-Z 600 05/01-7

NW 625 DQJA-SR-Z 625 DQJA-SR-PS-Z 625 DQJA-SQ-Z 625 DQJR-SR-Z 625 DQJR-SR-PS-Z 625 DQJB-Z 625 NW 800 (without motor adjustment only available with concealed mounting, DQJA-SR-PS-Z-MV 800) (with motor adjustment only available with screw mounting (-SM)) DQJA-SR-Z 800 DQJA-SR-PS-Z 800 DQJA-SQ-Z 800 DQJR-SR-Z 800 DQJR-SR-PS-Z 800 DQJB-Z 800 05/01-8

Special model If, for constructional reasons (e.g. ceiling grid), a particular faceplate size has been defined, it is possible to punch smaller swirl diffusers (1) into the faceplate. If a plenum box is required, it will be delivered, as a standard feature, in the size as the punch and not in the size of the faceplate. However, if the plenum box is larger, the standard hole (2) in the blade is placed in the faceplate, to allow damper adjustment. In case of a screw mounting, the screw holes (3) are adjusted to the plenum box. Special blade settings Increased multi-directional throw Blade position 1 Blade position 2 One-way throw Blade position 2 left Blade position 2 right covered (with 1/4 cover, see p. 13) two-way throw Blade position 2 left Blade position 2 right covered (with 1/4 cover, see p. 13) 05/01-9

Dimensions DQJA-SR-Z / DQJA-SR-PS-Z / DQJA-SQ-Z, with SAK-Z (for supply air) Suspension on-site external DQJA-SR-A / DQJA-SQ-A, with SAK-A (for return air) Suspension on-site inside painted to RAL 9005 (black) external Available sizes DQJA-SR-Z DQJA-SR-A DQJA-SR-PS-Z DQJA-SQ-A DQJA-SQ-Z, Size A E R T H ød H ød 310 308 290 8 7 260 158 300 198 400 398 370 260 158 300 198 500 498 470 12 300 198 350 248 600 598 570 12 350 248 400 298 625 623 570 24 350 248 400 298 800 798 770 12 455 353 455 353 05/01-10

DQJR-SR-Z / DQJR-SR-PS-Z, with SRK-Z (for supply air) Suspension on-site external Drawn rotated by 45 DQJR-SR-A, with SRK-A (for return air) Suspension on-site inside painted to RAL 9005 (black) external Drawn rotated by 45 Available sizes DQJR-SR-Z DQJR-SR-A DQJR-SR-PS-Z Size øa E økd TH H h ød H h ød 310 310 405 298 295 250 158 335 290 198 400 400 445 370 295 250 158 335 290 198 500 500 545 470 335 290 198 385 340 248 115 600 600 670 570 385 340 248 435 390 298 625 625 670 570 385 340 248 435 390 298 800 800 845 770 490 445 353 490 445 353 05/01-11

DQJB-Z, with SAK-Z (for supply air) Suspension on-site external DQJB-A, with SAK-A (for return air) Suspension on-site inside painted to RAL 9005 (black) external Available sizes DQJB-Z DQJB-A Size A E F R U H ød H ød 400 398 370 325 260 158 300 198 500 498 470 425 12 70 300 198 350 248 600 598 570 560 or 350 248 400 298 625 623 570 560 24 150 350 248 400 298 800 798 770 725 12 455 353 455 353 05/01-12

Dimensions of accessories Damper (-DK) for SAK for SRK Ball-impact guard (-BS) (only possible for DQJA-SR / DQJA-SR-PS-Z / DQJA-SQ with screw mounting (-SM) and for size 800 with screw mounting (- SM-V)). SZV =Cable-operated adjustment (at an extra charge) Rubber lip seal (-GD) Detail X ROB version (-ROB) Removable diffuser plate, throttle damper and volumetric flow meter DQJ Detail Z Volumetric flow meter (-VME) ULS screw DIN EN ISO 7380 M6x30 Available sizes Size A 310 308 400 398 500 498 600 598 625 623 800* 798 * Size 800: with SM-V mounting Dimensions SM-V mounting (for size 800 only) SM mounting for sizes 310-625, see p. 6 ff Indentation for slotted shallow-raised countersunk-head tapping screw DIN ISO 7051 pitch 4.8 (on-site) 05/01-13

1/4 cover (-AD) (only possible for supply air model) for 1- or 2-sided blanking Insulation for SAK inside(-ii) outside(-ia) Insulation for SRK inside(-ii) outside(-ia) Number of blanked blades Size DQJA-SR-Z DQJA-SQ-Z, DQJA-SR-PS-Z DQJR-SR-Z DQJR-SR-PS-Z DQJB 310 3 3 400 3 3 500 5 5 600 5 5 625 5 5 800 5 9 Number of blanked blades (x2) for-two sided blanking 05/01-14

Motor adjustment (-MV) 24 V AC, 2-point activation (only possible for DOJA-SR-PS-Z with screw mounting) Activation possible via AGV-3 Adjustable damper (-DV) only possible for DQJR-SR / DQJR-SR-PS-Z with screw mounting (-SM) 1.) 1.) Adjusting spindle damper 1.) 1.) 1.) with size 800, 4 additional mounting bores for SM mounting The plenum box type SAK-Z is without a hole for the cable. Cable routing should be done on-site. The motorised model increases the noise level by 3 db(a). If the plenum box has a damper, the installation of the damper is displaced by 90, and for its adjustment the faceplate must be removed. Available sizes (-MV) Size A 500 498 600 598 625 623 800 798 The noise level increases by 4 db (A) with an adjustable damper (-DV) compared with the diagram values with a plenum box. Available sizes (-DV) Size øa øb 310 310 290 400 400 370 500 500 460 600 600 560 625 625 560 800 800 760 Technical data (for -MV) Supply voltage 24 V AC ± 10% 50...60Hz Power consumption 2 W Dimensioning 6 VA Angle of rotation: 45... 270 can be set via potentiometer Protection type IP 40 Protection class: III (safety low voltage) Ambient temperature 0 C... +50 C Maintenance maintenance-free 05/01-15

Hit-and-miss damper (SS-K) (only DQJA-SR / DQJA-SR-PS-Z / DQJA-SQ) with screw mounting (-SM) with concealed mounting (-VM) Duct pole brace on-site Cylinder screw M6 x 100 DIN EN ISO 4762 Available sizes (-SS-K) Size A F G 310 308 290 295 400 398 365 370 500 498 465 470 600 598 565 570 625 623 565 570 800 798 765 770 A hit-and-miss damper is only available for a sheet steel or aluminium faceplate together with SM mounting. 05/01-16

Fastening methods Screw mounting (-SM) Detail Y Size R 310 8 400 12 500 12 600 12 625 24 Concealed mounting (-VM) DQJA-SR-Z / DQJA-SR-PS-Z DQJA-SQ-Z, DQJR-SR-Z / DQJR-SR-PS-Z DQJA-SR / DQJA-SQ / DQJA-SR-PS-Z In case of screw mounting, the ceiling swirl diffuser is fastened to the plenum box with 4 on-site countersunk screws.(see pages 5-7) (not available for size 800). DQJR-SR / DQJR-SR-PS-Z: In case of screw mounting (SM), the ceiling swirl diffuser will be mounted to the ceiling with 4 on-site countersunk screws, but this is only possible without a plenum box. DQJA-SR-A DQJA-SQ-A DQJR-SR-A DQJB-Z Central mounting (-MM) DQJA-SR-Z / DQJA-SR-PS-Z up to size 625 DQJB-A In case of a concealed mounting, the swirl diffuser is fastened to the plenum box with a pole brace and an Alen screw DIN EN ISO 4762 M6 (standard for size 800 with DQJA-... and DQJB-...). In case of a central mounting, the ceiling swirl diffuser is fastened to the plenum box with a retaining plate and an Allen screw DIN EN ISO 4762 M6. 05/01-17

Installation Plenum box below the ceiling (standard) Plenum box above the ceiling Fastening screw Fastening screw Attention: In case of installation above the ceiling, you have to specify the thickness of the ceiling "s". Length of the fastening screw (mm) Installation below the ceiling Installation above the ceiling DQJA-SR DQJA-SR DQJA-SR-PS-Z DQJA-SR-PS-Z DQJA-SQ DQJA-SQ DQJR-SR DQJB DQJR-SR DQJB DQJR-SR-PS-Z U=70 U=150 DQJR-SR-PS-Z U=70 U=150 Sizes 310-800 120 150 230 120 + s 150 + s 230 + s 05/01-18

Technical Data Pressure loss and noise level DQJA-SR-Z / DQJA-SR-PS-Z / DQJR-SR-Z / DQJR-SR-PS-Z for supply air, with plenum box relative sound power spectrum Hz 63 125 250 500 1000 2000 4000 8000 db -4-10 -8-10 -13-14 -21-28 DQJA-SR-Z 310 / DQJA-SR-PS-Z 310 DQJR-SR-Z 310 / DQJR-SR-PS-Z 310 DQJA-SR-Z 400 / DQJA-SR-PS-Z 400 DQJR-SR-Z 400 / DQJR-SR-PS-Z 400 Damper position (DS) 0% = OPEN / 100% = CLOSED DQJA-SR-Z 500 / DQJA-SR-PS-Z 500 DQJR-SR-Z 500 / DQJR-SR-PS-Z 500 DQJA-SR-Z 600/625 / DQJA-SR-PS-Z 600/625 DQJR-SR-Z 600/625 / DQJR-SR-PS-Z 600/625 05/01-19

DQJA-SR-Z 800 / DQJA-SR-PS-Z 800 DQJR-SR-Z 800 / DQJR-SR-PS-Z 800 DQJA-SR-A / DQJR-SR-A for return air, with plenum box Damper position (DS) 0% = OPEN / 100% = CLOSED DQJA-SR-A 310 / DQJR-SR-A 310 DQJA-SR-A 400 / DQJR-SR-A 400 05/01-20

DQJA-SR-A 500 / DQJR-SR-A 500 DQJA-SR-A 600/625 / DQJR-SR-A 600/625 DQJA-SR-A 800 / DQJR-SR-A 800 05/01-21

DQJA-SQ-Z, for supply air, with plenum box Damper position (DS) 0% = OPEN / 100% = CLOSED DQJA-SQ-Z 310 DQJA-SQ-Z 400 DQJA-SQ-Z 500 DQJA-SQ-Z 600/625 05/01-22

DQJA-SQ-Z 800 DQJA-SQ-A for return air, with plenum box Damper position (DS) 0% = OPEN / 100% = CLOSED DQJA-SQ-A 310 DQJA-SQ-A 400 05/01-23

DQJA-SQ-A 500 DQJA-SQ-A 600/625 DQJA-SQ-A 800 05/01-24

DQJB-Z for supply air, with plenum box Damper position (DS) 0% = OPEN / 100% = CLOSED DQJB-Z 400 DQJB-Z 500 DQJB-Z 600/625 DQJB-Z 800 05/01-25

DQJB-A for return air, with plenum box Damper position (DS) 0% = OPEN / 100% = CLOSED DQJB-A 400 DQJB-A 500 DQJB-A 600/625 DQJB-A 800 05/01-26

Maximum end velocity of jet DQJA-SR-Z / DQJA-SR-PS-Z / DQJR-SR-Z / DQJR-SR-PS-Z for supply air, with coanda effect Air throw "A" Air throw "B" DQJA-SR-Z 310 / DQJA-SR-PS-Z 310 DQJR-SR-Z 310 / DQJR-SR-PS-Z 310 DQJA-SR-Z 400 / DQJA-SR-PS-Z 400 DQJR-SR-Z 400 / DQJR-SR-PS-Z 400 Type DQJA-SR-Z 310 only available with air throw "A" Free jet = diagram value x 0.7 Air throw "A" = diagram value x 1.31 Free jet = diagram value x 0.7 05/01-27

DQJA-SR-Z 500 / DQJA-SR-PS-Z 500 DQJR-SR-Z 500 / DQJR-SR-PS-Z 500 DQJA-SR-Z 600/625 / DQJA-SR-PS-Z 600/625 DQJR-SR-Z 600/625 / DQJR-SR-PS-Z 600/625 Air throw "A" = diagram value x 1.25 Free jet = diagram value x 0.7 Air throw "A" = diagram value x 1.4 Free jet = diagram value x 0.7 DQJA-SR-Z 800 / DQJA-SR-PS-Z 800 DQJR-SR-Z 800 / DQJR-SR-PS-Z 800 Air throw "A" = diagram value x 1.4 Free jet = diagram value x 0.7 05/01-28

DQJA-SQ-Z, for supply air, with coanda effect Air throw "A" Air throw "B" DQJA-SQ-Z 310 DQJA-SQ-Z 400 model DQJA-SQ-Z 310 only available with air throw "A" Air throw "A" = diagram value x 1.18 05/01-29

DQJA-SQ-Z 500 DQJA-SQ-Z 600/625 Air throw "A" = diagram value x 1.22 Air throw "A" = diagram value x 1.4 DQJA-SQ-Z 800 Air throw "A" = diagram value x 1.4 05/01-30

DQJB-Z for supply air, with coanda effect, horizontal throw Air throw "A" Air throw "B" DQJB-Z 400 - air throw "A" DQJB-Z 500 - air throw "A" DQJB-Z 500 - air throw "B" 05/01-31

DQJB-Z 600/625 - air throw "A" DQJB-Z 600/625 - air throw "B" DQJB-Z 800 - air throw "A" DQJB-Z 800 - air throw "B" 05/01-32

DQJB-Z Isothermal, vertical air throw, blade position 1 DQJB 400 DQJB 500 DQJB 600/625 DQJB 800 05/01-33

Critical throw DQJA-SR-Z / DQJA-SR-PS-Z / DQJR-SR-Z / DQJR-SR-PS-Z for supply air, with coanda effect Air throw "B" Air throw "A" = x kr x 1.12 DQJA-SQ-Z, for supply air, with coanda effect Air throw "B" Air throw "A" = x kr x 1.12 05/01-34

DQJB in cooling mode, horizontal throw DQJB 400 DQJB 500 / 600 / 625 / 800 Air throw A Air throw B _ 05/01-35

Maximum penetration DQJA-SR / DQJA-SR-PS-Z / DQJR-SR / DQJR-SR-PS-Z in heating mode, blade position 1 DQJA-SR 310 / DQJA-SR-PS-Z 310 DQJR-SR 310 / DQJR-SR-PS-Z 310 DQJA-SR 400 / DQJA-SR-PS-Z 400 DQJR-SR 400 / DQJR-SR-PS-Z 400 DQJA-SR 500 / DQJA-SR-PS-Z 500 DQJR-SR 500 / DQJR-SR-PS-Z 500 DQJA-SR 600/625 / DQJA-SR-PS-Z 600/625 DQJR-SR 600/625 / DQJR-SR-PS-Z 600/625 DQJA-SR 800 / DQJA-SR-PS-Z 800 DQJR-SR 800 / DQJR-SR-PS-Z 800 05/01-36

DQJA-SQ in heating mode, blade position 1 DQJA-SQ 310 DQJA-SQ 400 DQJA-SQ 500 DQJA-SQ 600/625 DQJA-SQ 800 05/01-37

DQJB in heating case, vertical air guidance DQJB 400 DQJB 500 DQJB 600/625 DQJB 800 05/01-38

Induction ratio DQJA-SR-Z / DQJA-SR-PS-Z / DQJR-SR-Z / DQJR-SR-PS-Z with coanda effect DQJA-SQ-Z, with coanda effect Air throw "A" = diagram value x 0.8 Free jet = diagram value x 1.4 Air throw "A" = diagram value x 0.84 DQJB, with horizontal throw DQJB, with vertical air throw 05/01-39

Temperature ratio DQJA-SR-Z / DQJA-SR-PS-Z / DQJR-SR-Z / DQJR-SR-PS-Z with coanda effect DQJA-SQ-Z, with coanda effect Air throw "A" = diagram value x 1.3 Free jet = diagram value x 0.7 Air throw "A" = diagram value x 1.18 DQJB, with horizontal throw DQJB, with vertical air throw 05/01-40

Legend V ZU V AB (m³/h) [l/s] = Supply air volume (m³/h) [l/s] = Return air volume V X [l/s] = total air jet volume at point x V max (m/s) = Maximum end velocity of jet V mit (m/s) = Average end velocity of jet x (m) = horizontal throw y (m) = vertical throw x+y (m) = horizontal + vertical throw x kr (m) = Critical throw y H (m) = Maximum penetration in heating mode T O (K) = Temperature difference between supply air temperature and room temperature ( T O = t ZU - t R ) T X (K) = Temperature difference at point x t ZU ( C) = Supply air temperature t R ( C) = Room temperature P t (Pa) = Pressure loss L WA [db(a)] = A-weighted sound power level (kg/m³) = Density i (-) = Induction ratio (i = V X / V ZU ) TV (-) = Temperature ratio (TV = T X / T O ) Size (mm) = Nominal value DS (%) = Damper position (0% = CLOSED / 100% = OPEN) fm (Hz) = Octave centre frequency 05/01-41

Order details Ceiling swirl diffuser Square faceplate Circular blade pattern DQJA-SR Round faceplate Circular blade pattern DQJR-SR Square faceplate Square blade pattern DQJA-SQ Square faceplate Circular blade pattern DQJB continuous blades -PS divided blades - lowered by 70 mm -T 70 lowered by 150 mm -T 150 Supply air -Z Return air -A Blades RAL 9010 (white) Blades RAL 9005 (black) Blades Aluminium painted Air throw "A" -A Air throw "B" -B Size 310 only for air throw "A" (only for DQJA-SR-... / DQJA-SQ / DQJR-SR-...) 400 500 600 625 800 Screw mounting -SM (standard for DQJA-... ( and DQJB-...) Central mounting -MM (only of DQJA-SR-Z and DQJA-SR-PS-Z up to size 625) Concealed mounting -VM only in connection with plenum box SAK/SRK possible (standard for DQJR-SR / DQJR-SR-PS-Z) Screw mounting with concealed mounting -SM-V - only for model with Ball-impact guard (-BS) Order example: DQJA-SQ-Z-B-625-SM-SAK-Z-DK Unless stated otherwise, the thick-frame model will be delivered! 05/01-42

Order details of accessories Accessories: Plenum box for DQJA-SR / DQJA-SR-PS-Z / DQJA-SQ / DQJB type SAK Plenum box for DQJR-SR / DQJR-SR-PS-Z type SRK Hit-and-miss damper -SS-K (only DQJA-SR / DQJA-SR-PS-Z / DQJA-SQ) Supply air -Z without throttle damper - without rubber lip seal - without volumetric flow meter - without cableoperated adjustment Return air -A painted inside RAL 9005 (black) with throttle damper -DK with cable-operated adjustment -SZV (at an extra charge, only for SRK) with rubber lip seal -GD with volumetric flow meter -VME with screw mounting -SM with concealed mounting -VM Ball-impact guard -BS (for DQJA-SR / DQJA-SR-PS-Z / DQJA-SQ only possible with screw mounting (-SM) and for size 800 only with damper -DV (only possible for DQJR-SR / DQJR-SR-PS-Z with screw mounting (-SM)) 1/4 cover plate -AD (only supply air version possible) Motor adjustment -MV (DQJA-SR-PS-Z size 500-800 only, only possible with SM mounting) Activation possible via AGV-3 Standard model - ROB version -ROB without insulation - with insulation inside -Ii with insulation external -Ia Order example: DQJA-SQ-Z-B-625-SM-SAK-Z-DK Unless stated otherwise, the thick-frame model will be delivered! 05/01-43

Specification texts Ceiling swirl diffuser type DQJA-SR-Z, with square faceplate, circular blade patern. Particularly suitable for installation in comfort rooms with high air change rates, for clean rooms (in connection with particle filter boxes) and for VAV systems with variable volumetric flows (between 40 and 100%). Cooling and heating modes are possible. With faceplate made of sheet steel with high-quality powder coating, painted sheet steel RAL 9010 (white). With central pivoting, aerodynamic radially arranged air deflection blades in support blade profile sections made of plastic RAL 9010 (white), RAL 9005 (black, standard) or aluminium painted in the RAL colour of the faceplate (blades are not adjustable subsequently). Each blade is adjustable from the diffuser faceplate without using any special device, without dismounting the diffuser. The blades are divided lengthwise, allowing an air throw with an even higher induction to be set (air throw "B"). Free cross-section, resistance and sound power level remain the same in all blade positions. With visible screw mounting (-SM). For size 800 with concealed mounting (-VM), with motor adjustment only possible with SM mounting. TÜV inspected according to VDI 6022 Sheets 1+2, and DIN 1946 Sheet 2 Volumetric flows in m³/h at: 35dB(A) 40dB(A) - Size 310 229 278 - Size 400 275 335 - Size 500 450 575 - Size 600/625 680 820 - Size 800 1000 1220 Product: SCHAKO type DQJA-SR-Z - for supply air, with continuous air deflection blades, square faceplate and circular blade pattern TÜV tested according to VDI 6022 Sheets 1+2 and DIN 1946 Sheet 2. Product: SCHAKO type DQJA-SR-PS-Z - for return air, without air deflection blades, with square faceplate, circular punch TÜV tested according to VDI 6022 Sheets 1+2 and DIN 1946 Sheet 2. Volumetric flows in m³/h at: 35dB(A) 40dB(A) - Size 310 443 533 - Size 400 498 604 - Size 500 760 921 - Size 600/625 1336 1536 - Size 800 1625 1868 Product: SCHAKO type DQJA-SR-A - for supply air, with air deflection blades, with square faceplate, square blade pattern, less noise and pressure loss at the same volumetric flow. TÜV tested according to VDI 6022 Sheets 1+2 and DIN 1946 Sheet 2. Volumetric flows in m³/h at: 35dB(A) 40dB(A) - Size 310 250 300 - Size 400 295 350 - Size 500 550 660 - Size 600/625 740 900 - Size 800 1260 1500 Product: SCHAKO type DQJA-SQ-Z - for return air, without air deflection blades, with square faceplate, square punch, less noise and pressure loss at the same volumetric flow. TÜV tested according to VDI 6022 Sheets 1+2 and DIN 1946 Sheet 2. Volumetric flows in m³/h at: 35dB(A) 40dB(A) - Size 310 475 570 - Size 400 495 605 - Size 500 810 1000 - Size 600/625 1380 1700 - Size 800 1770 2130 Product: SCHAKO type DQJA-SQ-A - for supply air, with air deflection blades, with radial front plate, radial blade configuration. Standard with concealed mounting (-VM). TÜV tested according to VDI 6022 Sheets 1+2 and DIN 1946 Sheet 2. Product: SCHAKO type DQJR-SR-Z - for supply air, with continuous air deflection blades, with round faceplate, circular blade pattern. Standard with concealed mounting (-VM). TÜV tested according to VDI 6022 Sheets 1+2 and DIN 1946 Sheet 2. Product: SCHAKO type DQJR-SR-PS-Z - for return air, without air deflection blades, with faceplate, circular punch. Standard with concealed mounting (-VM). TÜV tested according to VDI 6022 Sheets 1+2 and DIN 1946 Sheet 2. Product: SCHAKO type DQJR-SR-A - for supply air, with air deflection blades, square faceplate and circular blade pattern, offset by 70 / 150 mm. TÜV tested according to VDI 6022 Sheets 1+2 and DIN 1946 Sheet 2. Product: SCHAKO type DQJB-T70/150 - for return air, without air deflection blades, with square faceplate, circular punch, offset by 70 / 150 mm. TÜV tested according to VDI 6022 Sheets 1+2 and DIN 1946 Sheet 2. Product: SCHAKO type DQJB-T70/150 05/01-44

- with air throw "A" for longer horizontal throw distance. - Faceplate made of: - Sheet steel painted to RAL 9005 (black) - Sheet steel painted to another RAL colour - Aluminium natural colour anodised (E6/EV1) - Stainless steel painted in the colour sand silver - with concealed mounting (-VM), made of aerodynamic aluminium profile suspended at 2 points (size 310), 4 points (up to size 500) and at 6 points, respectively, (from size 600), only available in conjunction with plenum box. - with central mounting (-MM), made of a retaining plate, for DQJA-SR-Z and DQJA-SR-PS-Z up to size 625 - Plenum box (-SRK, for DQJR-SR / DQJR-SR-PS-Z), made of galvanised sheet steel with fixing lugs. - Supply air model with integrated perforated straightener. - Return air model inside painted to RAL 9005 (black) - with damper (-DK) in plenum box for easy air volume regulation. - with cable-operated adjustment (-SZV), adjustable from below. - with volumetric flow meter (-VME) - with ROB version (-ROB), removable diffuser plate, throttle damper and volumetric flow meter. - with rubber lip seal (-GD), made of special rubber, at the connection pipe. - with thermal insulation - internal (-Ii) - external (-Ia) - with screw mounting with concealed mounting (-SM-V), for mounting with ball-impact guard (only for size 800). Accessories: - - Galvanised plenum box (-SAK, for DQJA-SR / DQJA-SR-PS / DQJA-SQ / DQJB) with fixing lugs. - Supply air model with integrated perforated straightener. - Return air model inside painted to RAL 9005 (black) - with throttle damper (-DK) in plenum box, adjustable from below, for simple air volume regulation without dismounting the faceplate. - with volumetric flow meter (-VME) - with ROB version (-ROB), removable diffuser plate, throttle damper and volumetric flow meter. - with rubber lip seal (-GD), made of special rubber, at the connection pipe. - with thermal insulation - internal (-Ii) - external (-Ia) - Galvanised sheet steel hit-and-miss damper (-SS-K) for air volume regulation (only for DQJA-SR / DQJA-SR-PS-Z / DQJA-SQ), suitable in particular in low-lying ducts for optimum air inflow. - Ball-impact guard (-BS, made of steel with high-quality powder coating in RAL 9010 (white), other RAL colours possible at an extra charge (only possible for DQJA-SR / DQJA-SR- PS-Z / DQJA-SQ with screw mounting (-SM) and for size 800 only with SM-V mounting). - Motor adjustment (-MV), with electric actuator (DQJA-SR- PS-Z size 500-800 only with screw mounting) for optimum and simple change of the air jet directions when requirements change, activation possible via AGV 3. A throttle damper that may have been built in has been built in offset by 90 and must be adjusted by dismounting the faceplate. - 1/4 cover plate (-AD), made of galvanised sheet steel for individual adaptation of the air flow to room conditions (only possible for supply air version). - Adjustable damper (-DV) made of galvanised sheet steel (only possible for DQJR-SR / DQJR-SR-PS-Z with screw mounting (-SM)). 05/01-45