GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

Similar documents
GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

GETZ EQUIPMENT INNOVATORS PART NO.: 3G59419 MODEL: BV 101 P PNEUMATIC BELT VISE WITH EXTENDED BELT & ROLLER

Getz Equipment Innovators 450 lb Portable / Wheeled Unit Dry Chemical Fill System Part No: 3G0061/3G0063

ESE Series Cast Iron Sewage Pumps

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Raydot LLC 24 Actuator (115 VOLT)

ADI-125/750 ADI-125/1500 ADI-125/2500

Air Curtain. Installation, Operating and Maintenance Instructions

24 Linear Actuator 115 Volts A.C. (Cat. # C430A)

FADE Series Wall Axial Fans

StormPro BA Series Sump Pump

DC to AC Power Inverters

DC to AC Power Inverters

Fifth Wheel Power Hitch Operations Manual

MIL-24/2600Q MIL-24/3200DQ

Open Display Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

OWNERS MANUAL JANUARY 2007 ISO

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P

Type Flexair Pneumatic Pressure Control Valves

StormPro BCV400 Sewage Ejector Pump

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

TPAK Series COOLANT PUMP

Pack-Master Air, Spark Resistant Product Manual

Penguin Gentoo 600B Cordless Sprayer User s Manual

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

OWNERS MANUAL JANUARY 2007 ISO

Kitchen Tech Series Air Curtain

FUNNEL CAKE FRYER Instruction Manual Models: 8078 / FC-4, 8082 / FC-6, and 8090 / FC-4

User s Manual D-Series Blowers and Exhausters

DISC BRAKE CALIPER TOOL SET

END USER TERMS OF USE

Model 7500 OPERATING INSTRUCTIONS MAINTENANCE INSTRUCTIONS. Terrco, Inc.

Extreme Duty Grapple (Rock, Skeleton, Scrap & Tine) Operation and Maintenance Manual

RECHARGEABLE 24 LED WORK LIGHT

D-Series Blowers and Exhausters

Cookshack Pellet Fired Charbroiler Models: CB012 CB024 CB036 CB048

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

25 GALLON PORTABLE OIL LIFT

Power. On Your Terms.

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

TPHK Series Immersible Pump

User s Manual and Operating Instructions

Harvil 4 Foot Air Hockey Table

Rapid Shrink 100. Owner s Manual

Instruction Manual. Fudge Puppy Display Case

10 Year Limited Warranty

TPHK Series Immersible Pump

(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

Lint Slide Grid Moist Air Applicator

Effective June 1, 2013 This guide supersedes all previous versions

Cabling for power, control, and video must be run to the installation site before the mount is installed.

Water Jetter Units DU JT50 / DU JT100

OBE, OBEXU, ON BOARD Battery Chargers

Read this entire manual before operation begins.

MACHINES / RECLAIMS WITH DUST BAG

OBAE, OBAEXU, ON BOARD Battery Chargers

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

TYPE S RELAY VALVE (Volume booster) Service Manual

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

LBT-3 WITH 300 CFM RECLAIM MANUAL NUMBER: 506 TABLE OF CONTENTS

Read this entire manual before operation begins.

Owner s Manual & Safety Instructions

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

PVI 60KW, PVI 82KW, PVI 95KW

QUALITY MISTING PUMPS

SIDE-WIND, A-FRAME TRAILER JACK. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Operating Instructions for PAC800 Battery Charger

AUTOMATIC SUBMERSIBLE UTILITY PUMP

Owner s Manual Supplement. Liquefied Petroleum Gas (LPG) Fuel System for 1998 GM Medium Duty Chassis (C-60/C-70) with 6.0L and 7.

Pack-Master Product Manual

SUBMERSIBLE POND PUMP

RAM 1500, 2019 CLASSIC & 2010-ON 2500/3500 INSTALLATION INSTRUCTIONS

Cincinnati, OH USA

Series 2100 Operating Instructions

Countertop B.I.B. Butter Dispenser Instruction Manual Model #2496

2SHE Series Direct-Drive Shutter Fans

SPC-PANEL Simplex, Single Phase Pump Control Panel

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

R E A D T H I S F I RST SAW USER GUIDE MODEL SVC4

Warranty. Seating Arrangements. AB Limited Warranty

MODEL V-24 OWNER'S MANUAL PARTS

Harvil 4 Foot Air Hockey Table

HP190SL Series Slimline Radon Fans

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

Installation & Operators Manual

WELDING FUME EXHAUSTERS & ARMS

QSSE, QSSEX INDUSTRIAL Battery Chargers

8220I-3CA1 10 kw Diesel DC Generator

Instructions for Tradewind. Please read before use. Model # Serial # Form # ADM Stowe Dr., Poway, Ca

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

CUSTOM CARRIERS. Crane Carrier Company Standard Warranty

Hot Dog Roller Grills Instruction Manual Model #8023, Model #8024 and Model #8025 Model #8023SL, Model #8024SL and Model #8025SL

9' & 12' CHALLENGER SHUFFLEBOARD TABLE ASSEMBLY INSTRUCTIONS

20250 Module Installation Guide

Transcription:

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

2320 Lakecrest Drive, Pekin IL 61554 PH. (888) 747-4389 Fax (309) 495-0625 Website: www.getzequipment.com LIMITED WARRANTY Getz Equipment Innovators warrants its products, and component parts of any product manufactured by Getz Equipment Innovators, to be free from defects in material and workmanship for a period of twelve (12) months from the date of purchase. During the warranty period, any such defects will be repaired or the defective parts replaced (at Getz Equipment Innovators option). The warranty does not cover defects resulting from modification, alteration, misuse, exposure to corrosive conditions, extremely high temperatures, improper installation or maintenance. Warranties on component items not manufactured by Getz Equipment Innovators are provided by others whose warranty, evaluation and judgment will be final. All implied warranties, including, but not limited to, warranties of fitness for purpose and merchantability, are limited to the time periods as stated above. In no event shall Getz Equipment Innovators be liable to incidental or consequential damages. Some states do not allow limitations on how long an implied warranty lasts or the exclusions or limitation of incidental or consequential damages, so that the above limitations or exclusions may not apply to you. Getz Equipment Innovators neither assumes nor authorizes any representative or other person to assume for it any obligation or liability other than as expressly set forth herein. Mobile Service Vehicles: The warranty does not cover: Defects in the chassis and or power unit Defects in separately manufactured products not produced by Getz Equipment Innovators Deterioration due to normal wear, tear, and exposure Repairs made necessary by negligent use, misuse, abuse, loading the service vehicle beyond its gross vehicle weight limitations, accident, acts of God, or other contingencies beyond the control of Getz Equipment Innovators. Repairs deemed necessary by reason of the failure to follow ordinary maintenance procedures. Repairs deemed necessary by reason of alterations done without Getz Equipment Innovators written approval. Warranty Service: All warranty repairs will be performed by Getz Equipment Innovators in Pekin, IL, unless otherwise authorized by Getz Equipment Innovators. Freight: Getz Equipment Innovators will not be liable for shipping or transportation charges to or from customer's location. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To obtain performance to the obligation of the warranty, write to Amerex Corp dba Getz Equipment Innovators, 2320 Lakecrest Drive, Pekin IL 61554, USA for instructions.

TABLE OF CONTENTS 1... HAZARDS 2... INTRODUCTION 3... SET-UP 4... OPERATION 5... DIAGRAM 6... PARTS LIST

HAZARDS Operating the dust collection system involves certain known hazards. EXPLOSION HAZARD: Do not operate this system where flammable vapors are present. FIRE HAZARD: No sparks should be allowed to enter the machine. Mixing chemically reactive materials should be avoided. Personnel should never allow smoking or smoldering materials to enter the machine. Avoid using or storing combustible materials near this machine. A properly installed fire suppression system can minimize the risk of damage. HIGH VOLTAGE HAZARD: Dust collection system operates on 120 volts AC. All service personnel should be aware of this fact and should have adequate training before any repairs are attempted on the equipment. All repairs are to conform to National Electrical Code (NEC) electrical standards. ROTATING MACHINERY HAZARD: The fan inside this unit is rotating at 1740-3600 rpm. The electrical power source must be disconnected and the power switch locked out prior to attempting repairs. Allow the unit to fully stop before any entry is made into the fan compartment below the dust collection filters. 1

INTRODUCTION IMPORTANT!!! This manual contains specific information concerning safety and precautionary measures in some sections. Read this manual thoroughly and comply with each section while using the most stringent safety precautions. The electrical requirements for the dust collection system are 120 volts on a 15 or 20 amp circuit. The dust collection system reduces the amount of airborne dust particles floating in air when servicing dry chemical fire extinguishers. 1. Using this system for any purpose other than dry chemical fire extinguisher agents will void all expressed and implied warranties. WARNING All electrical work should be done by licensed electricians in accordance with the National Electrical Code. 2. Installing a ground fault interrupter receptacle outlet in the power supply source prior to utilizing this system reduces the chance of electrical shock. 4. Do not operate this system without the filter (item 24) or filters (if secondary filter is used) installed and properly seated. 5. Discarded filter media must be disposed of in compliance with local, state, and federal codes. 2

SET-UP INSPECTION As soon as the shipment is received, it should be carefully inspected to make certain that the equipment has arrived in good condition. Even though the equipment is mounted on heavy shipping skids at our plant, it is possible for it to be damaged in shipment. All damages and shortages should be noted on the Bill of Lading and purchaser should take steps to file reports and damage claims to the carrier. Any damage incurred to a unit is the responsibility of the carrier, since it is the manufacturer s policy to make shipments FOB its factory i.e. ownership passes to the purchaser when the unit is loaded and accepted by the driver. Any claims for transit damage or shortage must be brought against the carrier by the purchaser. UNLOADING RECOMENDATION A forklift is recommended for unloading and placement of the system. SET-UP Remove the rubber mat covering the metal grate and examine the filter (item 24) or filters (if secondary filter is used) to be sure the filter or filters are laying flat on the sponge rubber seal material to ensure an adequate seal against dust leakage. Install any (optional) tool holders, nitrogen regulators, blow guns and any other extinguisher service tools on the back wall of the system marked as C. Side panels on the dust collection system item A & B can be unbolted and swung open to accommodate equipment to the sides of the system. Opening the side panels will reduce the pull of air borne dust particles from the front of the system and will equally pull from the front and sides of the system. 3

OPERATING INSTRUCTIONS 1. Move the power switch item (11) to the on position and adjust the angle position of the air louvers on item (13) to direct the air flow out of the system in the most beneficial direction. 2. The magnahelic gauge item (24) will monitor the efficiency of the filter media to collect dust particles. 3. Changing filters on the recommended interval will keep the efficiency of the system at the maximum level and will extend the service life of the blower motor. 4. Recommended Filter Element Change (Single Filter) When the system is operating check the magnahelic gauge (item 19), if the gauge reading is above 1.2 the filter Item (24) needs to be replaced. Primary Filter Part Number: 53898. Recommended Filter Element Change (Dual Filter) When the system is operating check the magnahelic gauge (item 19), if the gauge reading is above 1.3, the filter Item (24) needs to be replaced and the secondary filter checked for cleanliness. The secondary filter is optional and is not part of the main system. (Part Number: 53899) The benefit of having the secondary filter is improved filtration. (Hepa Filter) Caution, running the system with clogged or missing filters will result in overheating or damage to the blower motor. 5. Optional Secondary Filter Installation Install the optional secondary filter below the primary filter (item 24). 4

3G59542 DUST COLLECTOR REPLACEMENT PARTS LIST BLOWER: 1G54419 CAPACITOR: 1G54353 PRIMARY FILTER: 1G53898 SECONDARY FILTER: 1G53899 MAGNAHELIC GAUGE: 1G53929 POWER SWITCH: 1G54057 MAGNAHELIC TUBE: 1G54062 RUBBER MAT: 1G54059 SIDE GRATE: 1G53283 6