Pre-Delivery Guide.

Similar documents
Congratulations on your decision to enjoy the finest spa available... Welcome to the growing family of Hot Spring spa owners. DATE INSTALLED: DEALER:

Spa Location and Preparation 4-5. Wood or Synthetic Deck Installation 6. Delivery Access Backyard Delivery 7. How To Measure For Backyard Delivery 8

Congratulations on your decision to enjoy the finest spa available... Welcome to the growing family of Hot Spring spa owners.

Pre-Delivery Instructions

Pre-Delivery Guide. How to make delivery and installation of your new hot tub fast, easy and trouble-free.

PRE-DELIVERY GUIDE How to make the delivery and installation of your new hot tub fast, easy, and trouble-free

PRE-DELIVERY GUIDE 2011

LTR , Rev. P 1/14/15

PRE-DELIVERY GUIDE How to make the delivery and installation of your new hot tub fast, easy, and trouble-free

saratoga spas ADVANCE DELIVERY GUIDE Key steps to making the delivery and installation of your new spa smooth and hassle-free

INSTALLATION INSTRUCTIONS

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

Owner's/Installation Manual

PRE-DELIVERY. How to make delivery and installation of your new hot tub fast, easy and trouble-free.

Installation Manual. Q Series Quadplex Grinder Systems. Contents

poollux Power plx-pw60 & plx-pw100

Installation Instructions

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

IntelliTouch Pool and Spa Control System Load Center and Power Center

HERCULES II DC OWNER S MANUAL HERCULES II DC RESIDENTIAL & COMMERCIAL

MODEL D-SBG Single Arm Barrier Gate Operator

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions Electric Heaters 5 20 kw

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

Arnberg Industries & It s Partners are not responsible for any damage or injury caused by correct or incorrect installation of this transfer switch.

INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

ELECTRIC SERVICE RULES UTILITY/CATV SERVICES Issued Jan 2016

INSTALLATION GUIDE. For Carrier/Bryant Residential Power Systems

Transformer Installation, Operation, and Maintenance Manual

Model 8144NC Fresh Air Ventilator

Users Manual Certified Series Direct Drive Pump 1-7 LPM

SECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS. Body

2460 / 2472 / Series Simplex Grinder Systems

8300 Series Installation Guidelines

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

Jazz/FX Series Spa Light Jazz Series 120 Volt only FX Series 120 Volt or 12Volt. Owners Manual

SAVE THESE INSTRUCTIONS

UPPCO SERVICE MANUAL

SECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS. Body

INSTALLATION INSTRUCTIONS

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

ALL PURPOSE CNC/HEAVY DUTY

! WARNING! WARNING. Dock Boxes Unlimited, Inc. strongly recommends that these products be installed by a qualified electrician.

Contents. Delivering your Canadian Spa. Pre-Delivery Guide.

Refer to the franchised waste hauler for further assistance with capacity needs and container sizes:

Technical Manual. DLM Module. This manual should remain with the unit.

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

CHAPTER V RESIDENTIAL WIRING

SOLID WASTE AND RECYCLING ENCLOSURE STANDARDS

Load & Lock Cremators

MODEL D-WBG Wishbone Arm Barrier Gate Operator

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

JAZZ J400C (COLOR), J400AS (AUTO SYNC)

PRE-PLUMBED SEWAGE SYSTEM

Gate Operators, Inc. Model 7100UL Residential & Medium Duty Commercial Slide Gate Operator INSTALLATION MANUAL

Owner s Information Manual

Metering and Service Installation:

Owner s Manual. Important!

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh

Air Curtain. Installation, Operating and Maintenance Instructions

Florham Park, NJ USA Call (ASCO) for sales or service

SOUTH SEAS SPAS HYDROTHERAPY BENEFITS FEATURES. Deluxe and Standard South Seas Spas are as dynamic in quality as

Smooth Silent Precise. The best sensation is not to notice anything. A dream lifestyle

INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL

Patios Porches Pools Walkways

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

PRE-DELIVERY. How to make delivery and installation of your new hot tub fast, easy and trouble-free.

Nanometrics Solar Power System

Electric Vehicle Charging Station

Installation Instructions for Lighthouse SS Power Pedestal Rev. 3 5/20/14

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

ELITE SERIES R-410A Ready - Multi-Position

Installation and Service Manual for SRC25, SRC252, SRC50, SRC502, SRC75, SRC752

Service Requirements

Solar Power Owner s Manual

Model Numbers SAVI-NOTE75, SAVI-NOTE150

Instruction & Owner s Manual

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

OBE-3-FT Outdoor Series

10 Commercial, Industrial, Agricultural Services

INSTALLATION INSTRUCTIONS

Owner s Manual GLASSLINED PUMP TANK

HALLMARK INDUSTRIES INC

Electric Drive Vehicle Infrastructure Training. Instructor s Manual. National Alternative Fuels Training Consortium

VPL-SH1 Vertical Platform Lift

LIGHTNING PROTECTION UNIT (LPU)

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

INSTALLATION AND OPERATING INSTRUCTIONS

SmartBoost 50 INSTALLATION INSTRUCTIONS & OWNER S MANUAL LT93 SMTBST50 1. Issue 1 Print 2 AUTOMATIC SHORELINE TRANSFORMER

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

Installation Instructions for Admiral Power Pedestal (# )

Transcription:

www.clearwaterspas.com Thank you for purchasing a Clearwater spa. Clearwater manufacturers the best built and most energy efficient spas in the industry. You have now entered an elite group of spa owners. pre-delivery guide 01-03-19

IMPORTANT INFORMATION Please take a moment to read through the information provided on these pages. We want you to receive your purchase in excellent condition so you can begin enjoying it. The information also includes important specifications about how to prepare the site for the delivery. This book specifically covers site preparation, delivery access, and electrical requirements. Remember to read the Owner s Manual, located in the equipment area of the spa. Some of the instructions here are also located in the Owner s Manual. On the data plate is the spa model and serial number, which is important for warranty claims. Clearwater Spas reserves the right to change or modify the spas or any of the features without notification or any obligation. Please make a record of the following information. It will be valuable if service is required. Date Purchased: Date Installed: Dealer: Address: Phone: 2

In most cities, permits are required for the installation of electrical circuits or the construction of a deck or gazebo. In addition, some communities have ordinances concerning hot tubs, usually directed toward their safety when no one is home. Your Clearwater Spa cover is equipped with safety locks to prevent unsupervised child access. For any further questions or clarifications, your local building department is a good source. Your Clearwater Spas dealer will be able to answer all of your questions. Clearwater Spas 18800 Woodinville/Snohomish Rd. Woodinville, WA 98072 Phone: 425.483.1877 Fax: 425.487.1148 www.clearwaterspas.com 3

DELIVERY ACCESS MEASURE BEFORE YOU PURCHASE On the chart below, find your spa and relevant dimensions. These dimensions are of the spa laying on its side. Next, contact your spa dealer for the dimensions of the cart used to deliver your spa. Use the height of the cart and the H measurement for the vertical dimension. Use the width of the cart or W, whichever is greater, to determine the maximum clearances of the width. Dimensions Jets Seats Weights - Empty Filter Area Resort Series Inches Centimeters # # Lbs Kilograms Orlando 92.5" x 92.5" x 39.5" 235 x 235 x 100.3 cm 110 6 150 sf 1100 lbs. 499 Monaco 92.5" x 92.5" x 39.5" 235 x 235 x 100.3 cm 100 6 150 sf 1100 lbs. 499 Cabo 84" x 84" x 34" 213 x 213 x 86 cm 92 5 150 sf 800 lbs. 363 Rio 84" x 75" x 34" 213 x191 x 86 66 4 150 sf 700 lbs. 318 Dimensions Jets Seats Weights - Empty Filter Area Beachcraft Series Inches Centimeters # # Lbs Kilograms Pearl Island 92.5" x 92.5" x 39.5" 235 x 235 x 100.3 cm 66 5 150 sf 900 lbs. 408 Tradition 92.5" x 92.5" x 39.5" 235 x 235 x 100.3 cm 67 7 150 sf 900 lbs. 408 St. Andrew 84" x 84" x 34" 213 x 213 x 86 cm 66 5 150 sf 700 lbs. 318 Myrtle Beach 84" x 84" x 34" 213 x 213 x 86 cm 62 6 150 sf 700 lbs. 318 Dimensions Jets Seats Weights - Empty Filter Area Northwest Series Inches Centimeters # # Lbs Kilograms Broadmoor 92.5" x 92.5" x 39.5" 235 x 235 x 100.3 cm 51 6 100 sf 750 lbs. 340 Twin Peaks 92.5" x 84" x 34.5" 235 x 213.3 x 87.5 cm 57 5 100 sf 700 lbs. 318 Concordia 92.5" x 92.5" x 39.5" 235 x 235 x 100.3 cm 51 7 100 sf 750 lbs. 340 Liberty Lake 84" x 84" x 34" 213 x 213 x 86 cm 51 5 100 sf 600 lbs. 272 Fairview 84" x 84" x 34" 213 x 213 x 86 cm 51 6 100 sf 600 lbs. 272 Dimensions Jets Seats Weights - Empty Filter Area ES & Lite Series Inches Centimeters # # Lbs Kilograms ES93L 92.5" x 92.5" x 39.5" 235 x 235 x 100.3 cm 40 7 50 sf 750 lbs. 340 ES93L Lite 20 50 sf ES93NL 92.5" x 92.5" x 39.5" 235 x 235 x 100.3 cm 40 8 50 sf 750 lbs. 340 ES93NL Lite 20 50 sf ES84L 84" x 84" x 34" 213 x 213 x 86 cm 40 5 50 sf 600 lbs. 272 ES84L Lite 20 50 sf ES84NL 84" x 84" x 34" 213 x 213 x 86 cm 40 6 50 sf 600 lbs. 272 ES84NL Lite 20 50 sf ES76L 76" x 76" x 34" 193 x 193 x 86 cm 40 5 50 sf 420 lbs. 191 ES76L Lite 20 50 sf ES76NL 76" x 76" x 34" 193 x 193 x 86 cm 40 6 50 sf 420 lbs. 191 ES76NL Lite 20 50 sf ES76R 76" x 53" x 34" 193 x 135 x 86 40 3 50 sf 360 lbs. 163 ES76R Lite 20 50 sf ES76CC 76"x76"x40"(c) x 34" 193 x 193 x 101.6 x 86 40 4 50 sf 410 lbs. 186 4

Note: If there are stairs or other obstacles, the spa will have to travel over to get to the site, additional clearances may be required. Use the supplied measurements to help you determine the best location for your new spa. If you have any problems, contact your dealer for assistance. CAUTION: Clearwater Spas suggests an engineer or contractor be consulted before the spa is placed on an elevated deck. *NOTE: The Weight - Empty and Weight - w/water of the spa includes the weight of the occupants (assuming an average occupant weight of 175 lbs). Weights - w/water Water Capacity Electrical Reqmts. Pumps - U.S. / Can. Pumps - Europe Lbs Kilograms Gallons Liters U.S./Can Euro Pumps Circulation Pumps Circulation 5604 lbs. 2542 540 2044 240 v 220 v 3 5.0 hp 1 circ. 4 3.0 hp 1 circ. 5604 lbs. 2542 440 1665 240 v 220 v 3 5.0 hp 1 circ. 4 3.0 hp 1 circ. 3552 lbs. 1611 330 1249 240 v 220 v 3 5.0 hp 1 circ. 4 3.0 hp 1 circ. 3202 lbs. 1452 300 1136 240 v 220 v 2 5.0 hp 1 circ. 3 3.0 hp 1 circ. Weights - w/water Water Capacity Electrical Reqmts. Pumps - U.S. / Can. Pumps - Europe Lbs Kilograms Gallons Liters U.S./Can Euro Pumps Circulation Pumps Circulation 4486 lbs. 2035 430 1628 240 v 220 v 2 5.0 hp 1 circ. 3 3.0 hp 1 circ. 4736 lbs. 2148 460 1741 240 v 220 v 2 5.0 hp 1 circ. 3 3.0 hp 1 circ. 3453 lbs. 1566 330 1249 240 v 220 v 2 5.0 hp 1 circ. 3 3.0 hp 1 circ. 3619 lbs. 1642 350 1325 240 v 220 v 2 5.0 hp 1 circ. 3 3.0 hp 1 circ. Weights - w/water Water Capacity Electrical Reqmts. Pumps - U.S. / Can. Pumps - Europe Lbs Kilograms Gallons Liters U.S./Can Euro Pumps Circulation Pumps Circulation 4336 lbs. 1967 460 1741 240 v 220 v 2 5.0 hp 1 circ. 2 3.0 hp 1 circ. 3453 lbs. 1566 375 1420 240 v 220 v 2 5.0 hp 1 circ. 2 3.0 hp 1 circ. 3453 lbs. 1566 480 1817 240 v 220 v 2 5.0 hp 1 circ. 2 3.0 hp 1 circ. 3269 lbs. 1559 330 1249 240 v 220 v 2 5.0 hp 1 circ. 2 3.0 hp 1 circ. 3269 lbs. 1559 330 1249 240 v 220 v 2 5.0 hp 1 circ. 2 3.0 hp 1 circ. Weights - w/water Water Capacity Electrical Reqmts. Pumps - U.S. / Can. Pumps - Europe Lbs Kilograms Gallons Liters U.S./Can Euro Pumps Circulation Pumps Circulation 4336 lbs. 1967 430 1628 240 v 220 v 2 3.0 hp 1 circ. 2 3.0 hp 1 circ. 240 v 220 v 1 4.0 hp 1 3.0 hp 4503 lbs. 2043 450 1703 240 v 220 v 2 3.0 hp 1 circ. 2 3.0 hp 1 circ. 240 v 220 v 1 4.0 hp 1 3.0 hp 3269 lbs. 1483 320 1211 240 v 220 v 2 3.0 hp 1 circ. 2 3.0 hp 1 circ. 240 v 220 v 1 4.0 hp 1 3.0 hp 3436 lbs. 1559 340 1287 240 v 220 v 2 3.0 hp 1 circ. 2 3.0 hp 1 circ. 240 v 220 v 1 4.0 hp 1 3.0 hp 2588 lbs. 1176 260 984 240 v 220 v 2 3.0 hp 1 circ. 2 3.0 hp 1 circ. 240 v 220 v 1 4.0 hp 1 3.0 hp 2922 lbs. 1325 300 1136 240 v 220 v 2 3.0 hp 1 circ. 2 3.0 hp 1 circ. 240 v 220 v 1 4.0 hp 1 3.0 hp 1861 lbs. 844 180 681 240 v 220 v 2 3.0 hp 1 circ. 2 3.0 hp 1 circ. 240/120 v 220 v 1 4.0 hp 1 3.0 hp 2245 lbs. 1018 220 833 240 v 220 v 2 3.0 hp 1 circ. 2 3.0 hp 1 circ. 5

STEPS FOR A SUCCESSFUL INSTALLATION: 1. PREPARING FOR YOUR SPA Prior to receiving your new spa, you will need to prepare an area to install the spa. You will need to arrange to have your spa placed in your desired location and for the connection of the electrical circuits. In most cities, permits are required for the installation of electrical circuits. Review the path that your spa will take through your property along with the size of the spa to ensure you have enough clearance. If there are stairs or other obstacles, the spa will have to travel over to get to the site, additional clearances may be required. We have listed some key points to installing your spa that will help eliminate some of the unforeseeable situations that could occur. Avoid installing too close to a building or structure. Leave enough room around all sides to allow access to service panels. Install on a load bearing, level platform. Do not install less than 5 feet from ground conductors. Use non-conductive conduit for all wiring. If installing below a deck surface, leave enough room to access and remove service panels. We recommend a level 4 thick concrete pad if you are installing on land (versus deck or platform). The dimensions of the pad should be at least the outside dimension of the spa. You should also accommodate for steps or other items around the spa. Allow a few days for curing the cement when calculating your scheduled delivery date. Balconies and upper decks are not recommended for spa installations, but if you choose to do so, keep in mind that a large filled spa with 6 people can weigh as much as three tons. Balconies and decks must be constructed to current state and local building codes and must support at least 100 pounds per square foot. If you are building a deck around the spa, be sure that the deck does not cover any of the service panels to the spa. If you are building stairs for getting up to the spa, it is recommended that they be installed in such a way that they can be moved out of the way if entrance to the service panels is required. The most obvious thing to remember is to plan your installation in a location where it will be easy to move from the delivery truck to the location site. Spas are typically transported on a mover s dolly lying on their side. Check for adequate gate clearance and remove any fence panels if necessary to allow access to the installation site. 6

2. SITE SELECTION AND PREPARATION The location of your hot tub is entirely up to you. Carefully read these instructions for various ideas of locations that your new hot tub may be placed. By the time you have made your spa purchase, you probably have a spot already picked out. Prior to the spa delivery, please verify the following: Always place the spa on a compacted and level surface. The best surface is a level concrete pad. A spa, full of water, can weigh a great deal. Please ensure the spot can support the weight. Make sure to level your spa before filling it. Locate the equipment panel. The control box, drain valve, and optional ozone generator are usually located all in the same area. Be sure that the connections are tightened during filling. Water inside the system pack will cause the pack to fail and the breaker to trip. The panels, on all four sides, are removable. Be sure to have access on all four sides. Be sure to have easy access to the circuit breaker in the sub panel (220 volt models). Never let water into the sub panel (220 volt models), or into the electrical outlet that your spa is plugged in to. Your 220 volt spa s control box is rain tight when installed correctly with the door closed. 3. INSTALLATION - PLACING YOUR SPA OUTDOOR AND PATIO INSTALLATION To position the spa correctly in your backyard is very important. The warranty on a spa is voided if the site is not level. If you install your hot tub outdoors, a concrete pad is the best method for a stable and level surface. The concrete pad should be four inches thick. Your spa may be installed on a deck, providing the load rating can handle a full spa with people in it. DECK INSTALLATION When placing the spa on a deck, please ensure the maximum load capacity of the deck. Consult a qualified deck builder or structural engineer before you place the hot tub on an elevated deck or indoors. To determine the weight of your hot tub, please refer to the specifications on the website. This weight must not exceed the structural weight of the deck. 7

INDOOR INSTALLATION When installing a spa indoors, there are some special considerations. The combination of heat and moisture will accumulate on the floor and surrounding the spa. The flooring material needs to provide a grip when wet. The location also needs proper drainage to prevent water build-up around the spa. When building a room for your spa, it is best to have a floor drain installed. The humidity of a room with a spa can become a problem if there is not enough proper ventilation. Otherwise, problems such as dry rot, mildew or other problems may occur. GROUND PREPARATION Your spa has been engineered to rest on a variety of surfaces. The insulated spa floor base gives you the ability to find the perfect place. A concrete slab is the best for long term. There are other options available as long as the surface is level prior to delivery. The alternatives are 5/8 minus crushed packed rock, or a deck that is rated for the load. Brick pavers Cement Stone, slate, granite Decking: wood, synthetic When placing a spa on crushed rock, the easiest way to maintain its form is to build a frame and fill it with the crushed packed rock. Remember, if the spa is placed on grass or dirt, debris will get inside the spa as the users enter and exit. It is incredibly important to the operation and the draining of the tub for the tub to be level once it is installed. Failure to have the spa level prior to adding water can affect the warranty. Packed/crushed gravel: 5/8 minus Marble, travertine Decorative cement, stained Decorative cement & bricks 4. ELECTRICAL HOOK-UP REQUIREMENTS - 220V REMOVING SPA PANELS: DURATECH 1. Unscrew and remove trim pieces. 8 2. Unscrew and remove cabinet panel. This allows access to spa components.

REMOVING RIM 1. Remove the plastic tap-cap decorative screw head covers from screws on access spa panel. 2. Unscrew the screws from the access spa panel. 3. Remove the spa panel for access to spa components. Reverse these steps to attach the spa panel. ELECTRICAL CONNECTIONS BY LICENSED PERSONNEL To ensure you will have an opportunity to use your hot tub soon after delivery, it is very important that the required electrical service has been installed beforehand. IMPORTANT: ELECTRICAL CONNECTIONS MUST BE MADE BY QUALIFIED, LICENSED PERSONNEL. PLEASE CONTACT A LICENSED RESIDENTIAL ELECTRICIAN FOR THESE SERVICES. All models require a 50 amp single phase, 220 volt circuit breaker in the main electrical service panel. NOTE: WE REQUIRE THAT A SUB PANEL BE USED TO SUPPLY POWER AND PROTECT THE SPA. All 220 volt Clearwater spas must be wired in accordance with applicable local electrical codes, and all electrical work must be done by a licensed electrician. A licensed electrician should install a four-wire electrical service (two line voltages, one neutral, one ground) from the main electrical service panel to the sub-panel, and from the subpanel to the spa per the appropriate wiring diagram as illustrated on the next page (Figure 1-1). The grounding conductor must be at least #6 AWG. Your electrician should mount the sub-panel in the vicinity of the spa but it should not be closer than five (5) feet from the spa s water edge (NEC 680-38 to 41-A-3). WARNING: Removing or bypassing the GFCI breakers in the sub panel at any time will result in an unsafe spa and will void the warranty. WIRE SPECIFICATION NOTE: Long electrical runs may require a larger gauge feed wire than stated. We recommend that a maximum voltage drop of 3% be used when calculating the larger wire size. Refer to the Wiring Diagrams (figure 1-1) for the electrical requirements of the 220 volt models. Do not turn on power to the spa when the tub is not filled with water. The closer you locate the spa to the main service panel, the less money you will have to spend on wire. Wire can become expensive if you run long lengths. Always shut off power at the source when working with any electrical power!! Failure to do this could result in serious injury or even death! 9

ELECTRICAL REQUIREMENTS - 220V (CONT.) IMPORTANT: Electrical connections must be made by qualified, licensed personnel. Please contact a licensed residential electrician for these services. Figure 1-1 220 volt wiring configuration from the house to the spa 10

ENERGY EFFICIENCY GREEN TECHNOLOGY PROVIDING A GREENER SPA. Clearwater Spas is strongly committed to protecting the health of our environment and manufacturing energy efficient hot tubs that help to conserve our natural resources. We strive to provide clean air, clean water and recycling solutions in our manufacturing process and the components that go into our spas. E-SMART TECHNOLOGY Your spa is made with e-smart or technology built into every hot tub to provide a complete energy efficient system. From the initial engineering design stage through our manufacturing, product usage, we have set a high standard to keep our hot tubs environmentally sound. This symbol signifies the highest energy efficiencies, the smartest engineering detail standards, global environmentally green components and e-cycling sound programs. Energy Efficient ENERGY EFFICIENT Clearwater Spas RTB (reflective thermal barrier) rigid insulation is 12% more energy efficient than spray foam insulation. Our insulation panels reflect and recycle heat from within the cabinet keeping it warm and dry. CEC Certified CALIFORNIA ENERGY COMMISSION (CEC) CERTIFIED All of Clearwater Spas are certified to California s Energy Commission (CEC) the most stringent energy efficiency standards in the United States. We not only meet these standards we exceed them. Manufacturing HEALTHY FACTORY PROCESS We are focused on providing healthy and safe solutions in our factory for our employees and our environment. This includes processes for good air quality, and energy efficient components. Clean Air CLEAN AIR FACTORY Our Eco-Spray process for strengthening every spa shell has 0% styrene, no odor and emits no VOC s (volatile organic compounds) for a cleaner air environment. Clean Water CLEAN WATER SOLUTIONS We provide cutting edge clean water sanitizing solutions to help provide natural alternatives and help reduce the need for chemicals. UV-C light, ozone and re-usable filters provide natural clean water solutions. 11

Resort Series Orlando 92.5" (235 cm) Ground Contact 86" (218.4 cm) 92.5" (235 cm) Ground Contact 86" (218.4 cm) 16 (40.6 cm) 16 (40.6 cm) Pump #2 Pump #4 Circ. Pump Pump #3 Pump #1 31" (78.7 cm) 12

Monaco 92.5" (235 cm) Ground Contact 86" (218.4 cm) Resort Series 92.5" (235 cm) Ground Contact 86" (218.4 cm) 16" (41 cm) 16" (41 cm) Pump #3 Pump #4 Circ. Pump Pump #1 Pump #2 31" (78.7 cm) 13

Resort Series Cabo 84" (213.4 cm) Ground Contact 76" (193 cm) 84" (213.4 cm) Ground Contact 76" (193 cm) 16" (41cm) 16" (41cm) Pump #3 Pump #4 Pump #1 Pump #2 Circ Pump 28" (68.6 cm) 14

Rio 75" (190.5 cm) Ground Contact 71" (180.3 cm) Resort Series 84" (213.4 cm) Ground Contact 78" (198 cm) 16" (41 cm) 16" (41 cm) Pump #1 Pump #2 Circ. Pump 28" (71 cm) 15

Beachcraft Series Pearl Island 92.5" (235 cm) Ground Contact 86" (218.4 cm) Circ. Pump 92.5" (235 cm) Ground Contact 86" (218.4 cm) 16 (40.6 cm) 16 (40.6 cm) Pump #2 Pump #1 Pump #3 31" (78.7 cm) Electrical Knockout 16

Tradition 92.5" (235 cm) Ground Contact 86" (218.4 cm) Beachcraft Series 92.5" (235 cm) Ground Contact 86" (218.4 cm) 16 (40.6 cm) 16 (40.6 cm) Pump #2 Pump #3 Circ. Pump Pump #1 31" (78.7 cm) Electrical Knockout 17

Beachcraft Series St. Andrew 84" (235 cm) Ground Contact 78" (198.1 cm) Circ. Pump 84" (235 cm) Ground Contact 78" (198.1 cm) 16 (40.6 cm) Pump #3 16 (40.6 cm) Pump #2 27" (68.6 cm) 18

Myrtle Beach Beachcraft Series 84" (235 cm) Ground Contact 78" (198.1 cm) 84" (235 cm) Ground Contact 78" (198.1 cm) 16" (41 cm) 16" (41 cm) Pump #2 Pump #3 Circ. Pump Pump #1 28" (71cm) 19

Northwest Series Broadmoor 92.5" (235 cm) Ground Contact 86" (218.4 cm) 92.5" (235 cm) Ground Contact 86" (218.4 cm) 16 (40.6 cm) 16 (40.6 cm) Pump #3 Pump #1 Pump #2 Circ. Pump 31" (78.7 cm) Electrical Knockout 20

Concordia Northwest Series 92.5" (235 cm) Ground Contact 86" (218.4 cm) 92.5" (235 cm) Ground Contact 86" (218.4 cm) 16 (40.6 cm) 16 (40.6 cm) Pump #3 Pump #1 Pump #2 Circ. Pump 31" (78.7 cm) Electrical Knockout 21

Northwest Series Twin Peaks 84" (213 cm) Ground Contact 86" (218.4 cm) 92.5" (235 cm) Ground Contact 86" (218.4 cm) 16 (40.6 cm) 16 (40.6 cm) Pump #3 Pump #1 Pump #2 Circ. Pump 31" (78.7 cm) Electrical Knockout 22

Liberty Lake Northwest Series 84" (235 cm) Ground Contact 78" (198.1 cm) 84" (235 cm) Ground Contact 78" (198.1 cm) 16 (40.6 cm) Pump #3 Pump #1 Pump #2 Circ. Pump 16 (40.6 cm) 27" (68.6 cm) 23

Northwest Series Fairview 84" (235 cm) Ground Contact 78" (198.1 cm) 84" (235 cm) Ground Contact 78" (198.1 cm) 16 (40.6 cm) Pump #1 Pump #2 Circ. Pump 16 (40.6 cm) 27" (68.6 cm) 24

ES Series ES93L 92.5" (235 cm) Ground Contact 84" (213.4 cm) 92.5" (235 cm) Ground Contact 84" (213.4 cm) 16" (41 cm) 16" (41 cm) Pump #1 Circ. Pump Pump #2 31" (78.7 cm) 25

ES Series ES93 92.5" (235 cm) Ground Contact 84" (213.4 cm) 92.5" (235 cm) Ground Contact 84" (213.4 cm) 16 (40.6 cm) Pump #2 Pump #1 16 (40.6 cm) Circ. Pump 31" (78.7 cm) Electrical Knockout 26

ES Series ES84L 84" (213.4 cm) Ground Contact 76" (193 cm) 84" (213.4 cm) Ground Contact 76" (193 cm) 16" (41 cm) 16" (41 cm) Pump #1 Pump #2 Circ. Pump 28" (71 cm) 27

ES Series ES84 84" (213.4 cm) Ground Contact 76" (193 cm) 84" (213.4 cm) Ground Contact 76" (193 cm) 16 (40.6 cm) Pump #2 Pump #1 16 (40.6 cm) Circ. Pump 28" (68.6 cm) Electrical Knockout 28

ES Series ES76L 76" (193 cm) Ground Contact 72" (183 cm) 76" (193 cm) Ground Contact 72" (183 cm) 16" (41 cm) 16" (41 cm) Pump #1 Pump #2 Circ. Pump 28" (71 cm) Electrical Knockout 29

ES Series ES76 76" (193 cm) Ground Contact 72" (183 cm) 76" (193 cm) Ground Contact 72" (183 cm) 16" (41 cm) 16" (41 cm) Pump #2 Pump #1 Circ. Pump 27" (69 cm) 30

ES Series ES76CC 76" (193 cm) Ground Contact 69" (175 cm) 77" (193 cm) Ground Contact 69" (175 cm) 16" (41 cm) 16" (41 cm) Pump #1 Pump #2 Circ. Pump Approx. 36" (91 cm) 23" (58.4 cm) Electrical Knockout 31

ES Series ES76R 53" (135 cm) Ground Contact 46" (117 cm) Pump #2 Circ. Pump 76" (193 cm) Ground Contact 69" (175 cm) Pump #1 24" (61 cm) 16" (40.6 cm) Electrical Knockout 32

ES93L-Lite ES Lite Series 92.5" (235 cm) Ground Contact 84" (213.4 cm) Pump #1 (Euro Pump #1) 92.5" (235 cm) Ground Contact 84" (213.4 cm) Circ. Pump Subwoofer 8" (20 cm) (Euro Blower) Pump #2 (Euro Pump #2) 31" (78.7 cm) Salt System Control Salt System Electrode Topside Control Equipment Access 33

ES Lite Series ES93-Lite 92.5" (235 cm) Ground Contact 84" (213.4 cm) Pump #1 (Euro Pump #1) Pump #2 (Euro Pump #2) 92.5" (235 cm) Ground Contact 84" (213.4 cm) Subwoofer (Euro Blower) Circ. Pump 8" (20 cm) 31" (78.7 cm) Salt System Control Salt System Electrode Topside Control Equipment Access 34

ES84L-Lite 84" (213.4 cm) Ground Contact 76" (193 cm) ES Lite Series Pump #1 (Euro Pump #1) Pump #2 (Euro Blower) 84" (213.4 cm) Ground Contact 76" (193 cm) Circ. Pump (Euro Pump #2) 8" (20 cm) Subwoofer 27" (68.6 cm) Equipment Access Salt System Electrode Salt System Control Topside Control 35

ES Lite Series ES84-Lite 84" (213.4 cm) Ground Contact 76" (193 cm) Pump #1 (Euro Pump #1) Pump #2 (Euro Blower) 84" (213.4 cm) Ground Contact 76" (193 cm) (Euro Pump #2) 8" (20 cm) Circ. Pump Subwoofer 27" (68.6 cm) Equipment Access Salt System Control Topside Control Salt System Electrode 36

ES76L Lite ES Lite Series 76" (193 cm) Ground Contact 72" (183 cm) 76" (193 cm) Ground Contact 72" (183 cm) 16" (41 cm) 16" (41 cm) Circ. Pump Pump #1 25" (64 cm) Electrical Knockout 37

ES Lite Series ES76 Lite 76" (193 cm) Ground Contact 72" (183 cm) 76" (193 cm) Ground Contact 72" (183 cm) 16" (41 cm) 16" (41 cm) Circ. Pump Pump #1 25" (64 cm) Electrical Knockout 38

ES76R Lite 76" (193 cm) Ground Contact 72" (183 cm) ES Lite Series 76" (193 cm) Ground Contact 72" (183 cm) Circ. Pump Opt. Pump #1 8" (20 cm) 25" (64 cm) Salt System Control Salt System Electrode Topside Control Equipment Access 39

NOTES FOR YOUR HOT TUB CONTRACTOR SUGGESTIONS Electrician Name: Telephone: Name: Telephone: Masonry Name: Telephone: Name: Telephone: General Name: Telephone: Name: Telephone: Services available from your Clearwater Spas dealer SERVICE CHECKLIST AND ANY COSTS Pre-Delivery site inspection Deliver spa to installation site Unwrap spa and haul away packaging material Set up and level spa General spa operation and maintenance orientation Water quality and maintenance operation Adjust the water s Total Alkalinity, Calcium Hardness and ph Sanitize the water Inspect the spa cover, place on spa Review winterizing instructions Review Owner s Manual Follow-up call In-store water analysis Total Costs 40

NOTES FOR YOUR HOT TUB Additional products that may be available from your Clearwater Spas Dealer Salt Sanitation System Clean Light UV-C Sanitation System CD Ozone Generator Nature 2 Sticks Nature 2 test strips Stain and Scale Remover Filter Cleaner Ph-Alkalinity Up Ph-Alkalinity Down Concentrated Chlorinating Granules Defoamer Calcium Hardness Increaser 4-way test strips Coverlift Cover Rock-It Vinyl covers Spa vacuums Spa steps Stain kits Replacement filter cartridges Pillows 41

NOTES: 42

NOTES: 43

18800 Woodinville/Snohomish Rd. P.O. Box 2140 Woodinville, WA 98072 425.483.1877 www.clearwaterspas.com pre-delivery guide 1-1-15