Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

Similar documents
User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation

User s Manual Power Supply IM E. 5th Edition

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

No.LV31JE To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

Fiber Optic Illuminator. Model 21AC Model 21DC

Triple Output Power Supply

Lumitester PD-20 Control Kit

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

Instruction manual. High voltage insulation resistance tester KEW3121B/3122B

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

Megohmmeter Test Probe

OPERATING INSTRUCTIONS

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

Hybex Microsample Incubator

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

Model 1672, 1673 Triple Output Power Supply

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

Switching DC Power Supply

i400s Calibration Information Introduction

PY-11 Voltage & Continuity Tester

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual


Users Manual. Phase Rotation Indicator

OPERATIONS MANUAL. Mini Centrifuge Model MCF Certified

FD Conveyor for FD 260 Tabber

i3000s/i2000 Flex AC Current Probe

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Register your instrument! HeatSealer S100. Operating manual

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

1 AMP CURRENT SOURCE

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

362 Clamp Meter. Users Manual

OPERATING INSTRUCTION

BENCHTOP INSTRUMENT. Single Channel DC Power Supply SL Series Operation Manual V1.0

DC POWER SUPPLY ALIMENTATION C.C.

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Dawson DAN100. Analog Multimeter User s Manual

323/324/325 Clamp Meter

INSTRUCTION MANUAL VISCOTESTER VT-05 / VT-06 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

WPS600. Hydraulic Pressure Transducer. User s Guide. 600 bar 60 MPa 8700 psi

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

OPERATING INSTRUCTIONS

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

Declaration of Conformity

OPERATING INSTRUCTION

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

User's Manual. MV100 Rechargeable Battery Model. Yokogawa Electric Corporation. IM MV100-41E 1st Edition

SLA Battery Capacity Analyzer

SPV Series Slides OPERATING MANUAL. Table of contents 1 Introduction Compliance with the EC Directives Names of parts...

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

Models: EP EP EP EP EP EP USER MANUAL ENGLISH

QA Maintenance and Inspection Vizion DR+ Detector Guide

System 3 ZB1PS Device Chassis. Operator s Manual

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

User's Manual. Earth Ground Resistance Tester. Model Introduction

1.Safe testing IMPORTANT:

Cincinnati, OH USA

True RMS Autoranging Multimeter

WPS bar, 60 MPa, 8700 psi Hydraulic Pressure Transducer. User s Guide

UZK12.071, UZO GENERAL DESCRIPTION 2. DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9.

Triple Output High Resolution Power Supply. User Manual

HEINE NT4 MED V

Digital Multimeter User's Manual

Autoranging Multimeter

USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

BENCHTOP INSTRUMENT. Multi-channel DC Power Supply TP2000N/TP2000PU/TP4000N Series Operation Manual V1.0

UZK12.071, UZO DATA 1. GENERAL DESCRIPTION 4. MARKINGS 3. ORDER NUMBERS PASSIVE BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9.

Verti Blast. User Manual. Order code: EQLED355

DIGITAL RCD(ELCB) TESTER

82V LITHIUM-ION BATTERY CHARGER GC 400

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

Autoranging Industrial Multimeter

302+/303 Clamp Meter. Users Manual

YT-720 SERIES. Rotork YTC Limited VERSION 1.07

Model G14SD Vapor Management System

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

28W WORK LAMP Model: CTL28 Part No:

No.EX -OME0016-A PRODUCT NAME. SI unit. MODEL / Series / Product Number EX140-SDN1

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

AC/DC CURRENT TRANSDUCER INSTRUCTION MANUAL

Instruction Manual for FI Controller

Installation manual wall-mounted distributor

KSZ 10B Current Probe Calibrator. Instruction Manual

HOME BOX EV CHARGING STATION WITH FIXED CABLE

Cable Length Meter INSTRUCTION MANUAL

PHASE ROTATION INDICATOR with OPEN PHASE CHECKER

OPERATING INSTRUCTIONS

EPS/ELA-Series User Manual EPS/ELA 250W

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

EPM1510SJ Datasheet. Power Modules (Power Supplies with Ultra-low Standby Power Consumption) TAMURA CORPORATION Rev.

OPERATING INSTRUCTIONS

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Transcription:

INSTRUCTION MANUAL

Contents Introduction Inspection Notes on Safety Precautions i i ii vii Chapter 1 Overview 1 1.1 Product Overview 1 1.2 Names of Parts 2 Chapter 2 Specifications 5 2.1 Product Specifications 5 2.2 Standards Applying 6 Chapter 3 Measurement Procedure 7 3.1 Preparations 8 3.2 Measurement Procedure 9 Chapter 4 Description of Parts 13 4.1 Power Supply Receptacle 13 4.2 How to Change the Power Supply Fuse and Change the Power Supply Voltage 13

i Introduction Thank you for purchasing the HIOKI "Model 3272 POWER SUPPLY." To obtain maximum performance from the product, please read this manual first, and keep it handy for future reference. Inspection When you receive the product, inspect it carefully to ensure that no damage occurred during shipping. If damage is evident, or if it fails to operate according to the specifications, contact your dealer or Hioki representative. Supplied accessories Power cord 1 Instruction manual 1 Spare fuse 1 100 V, 120 V: F1.0 AL/250 V, 20 mm x 5 mm dia. 220 V, 240 V: F0.5 AL/250 V, 20 mm x 5 mm dia. Introduction

ii Notes on Safety WARNING This product is designed to comply with IEC 61010 Safety Standards, and has been thoroughly tested for safety prior to shipment. However, mishandling during use could result in injury or death, as well as damage to the product. Be certain that you understand the instructions and precautions in the manual before use. We disclaim any responsibility for accidents or injuries not resulting directly from product defects. Notes on Safety

iii Safety Symbols This manual contains information and warnings essential for safe operation of the product and for maintaining it in safe operating condition. Before using it, be sure to carefully read the following safety precautions. The symbol printed on the product indicates that the user should refer to a corresponding topic in the manual (marked with the symbol) before using the relevant function. In the manual, the symbol indicates particularly important information that the user should read before using the product. Indicates a grounding terminal. Indicates a fuse. Indicates AC (Alternating Current). Indicates the ON side of the power switch. Indicates the OFF side of the power switch. Notes on Safety

iv The following symbols are used in this Instruction Manual to indicate the relative importance of cautions and warnings. DANGER WARNING CAUTION NOTE Indicates that incorrect operation presents an extreme hazard that could result in serious injury or death to the user. Indicates that incorrect operation presents a significant hazard that could result in serious injury or death to the user. Indicates that incorrect operation presents a possibility of injury to the user or damage to the product. Indicates advisory items related to performance or correct operation of the product. Notes on Safety

v Measurement categories (Overvoltage categories) To ensure safe operation of measurement products, IEC 61010 establishes safety standards for various electrical environments, categorized as CAT I to CAT IV, and called measurement categories. These are defined as follows. CAT I : Secondary electrical circuits connected to an AC electrical outlet through a transformer or similar device. CAT II : Primary electrical circuits in equipment connected to an AC electrical outlet by a power cord (portable tools, household appliances, etc.) CAT III : Primary electrical circuits of heavy equipment (fixed installations) connected directly to the distribution panel, and feeders from the distribution panel to outlets. CAT IV : The circuit from the service drop to the service entrance, and to the power meter and primary overcurrent protection device (distribution panel). Notes on Safety

vi Higher-numbered categories correspond to electrical environments with greater momentary energy. So a measurement device designed for CAT III environments can endure greater momentary energy than a device designed for CAT II. Using a measurement product in an environment designated with a higher-numbered category than that for which the product is rated could result in a severe accident, and must be carefully avoided. Never use a CAT I measuring product in CAT II, III, or IV environments. The measurement categories comply with the Overvoltage Categories of the IEC60664 Standards. Notes on Safety

vii Precautions Follow these precautions to ensure safe operation and to obtain the full benefits of the various functions. Preliminary Check Before using the product the first time, verify that it operates normally to ensure that the no damage occurred during storage or shipping. If you find any damage, contact your dealer or Hioki representative. Precautions

viii DANGER Be sure to observe all operating precautions for the waveform monitoring instrument (oscilloscope or recorder) and other measurement instruments to which the CLAMP ON PROBE (refer to P5 Compatible sensors) is connected using with this device. When using a measurement instrument that does not provide isolation between its input terminals and chassis or other input terminals, please pay attention to the following points. If a signal is applied to an input terminal other than that to which the CLAMP ON PROBE is connected, do not connect the ground-side terminal to any non-ground potential. Otherwise, short-circuit current will flow through the CLAMP ON PROBE or this device from the ground terminal, which could cause an electrical accident or damage. CLAMP ON PROBE Precautions

ix WARNING To avoid electrical accidents and to maintain the safety specifications of this instrument, connect the power cord only to a 3-contact (two-conductor + ground) outlet. CAUTION To avoid damage to the product, protect it from physical shock when transporting and handling. Be especially careful to avoid physical shock from dropping. Do not store or use the product where it could be exposed to direct sunlight, high temperature or humidity, or condensation. Under such conditions, the product may be damaged and insulation may deteriorate so that it no longer meets specifications. To avoid damaging the power cord, grasp the plug, not the cord, when unplugging the cord from the power outlet. This product is not designed to be entirely water- or dust-proof. Do not use it in an especially dusty environment, nor where it might be splashed with liquid. This may cause damage. Precautions

x Maintenance & Service To clean the product, wipe it gently with a soft cloth moistened with water or mild detergent. Never use solvents such as benzene, alcohol, acetone, ether, ketones, thinners or gasoline, as they can deform and discolor the case. If the product seems to be malfunctioning, contact your dealer or Hioki representative. When sending the product for repair, pack carefully to prevent damage in transit. Include cushioning material so the instrument cannot move within the package. Be sure to include details of the problem. Hioki cannot be responsible for damage that occurs during shipment. Precautions

1 Chapter 1 Overview 1.1 Product Overview This unit is a special-purpose power supply for the 3273-50, 3273, 3274, 3275, and 3276 CLAMP ON PROBE. Chapter 1 Overview

2 1.2 Names of Parts External view Power indicator Power supply receptacles Front view Chapter 1 Overview

3 Power supply connector Fuse holder Power switch On Voltage window Off Grounding terminal Rear view Chapter 1 Overview

4 Chapter 1 Overview

5 Chapter 2 Specifications 2.1 Product Specifications Compatible sensors Number of power supply connectors Output voltage 12 V 0.5 V Rated output current Ripple voltage Load influence Temperature influence Power supply voltage influence Operating temperature and humidity range Storage temperature and humidity range 3273-50, 3273, 3274, 3275, 3276 CLAMP ON PROBE 2 600 ma (sum total of all channels and all output voltages) 3 mvp-p or less (at rated output current) Within output voltage limits indicated above for current output in the range 0 to 600 ma. Within output voltage limits indicated above for ambient temperature in the range 0 to 40 (32 to 104 ). Within output voltage limits indicated above for the rated power supply voltage, 10%. 0 to 40 (32 to 104 ), 80% RH or less (no condensation) -10 to 50 (14 to 122 ), 80% RH or less (no condensation) Chapter 2 Specifications

6 Location for use Indoor,altitude up to 2000 m (6562 feet) Rated supply voltage Rated supply frequency Maximum rated power External dimensions Mass Accessories 100 V AC (120, 220, and 240 V require specification) (Voltage fluctuation of 10% from the rated supply voltage are taken into account.) 50/60 Hz 20 VA Approx. 73W x 110H x 186D mm Approx. 2.87"W x 4.33"H x 7.32"D Approx. 1.1 kg Approx. 38.8 oz. Power cord, Instruction manual, Spare fuse F1.0 AL/250 V, 20 mm x 5 mm dia. (for 100 V and 120 V models) or F0.5 AL/250 V, 20 mm x 5 mm dia. (for 220 V and 240 V models) 2.2 Standards Applying Safety EN61010, Pollution Degree 2 EMC EN 61326 EN 61000-3-2 EN 61000-3-3 Chapter 2 Specifications

7 Chapter 3 Measurement Procedure Chapter 3 Measurement Procedure

8 3.1 Preparations DANGER Be sure to observe all operating precautions for the waveform monitoring instrument (oscilloscope or recorder) and other measurement instruments to which the CLAMP ON PROBE (refer to P5 Compatible sensors) is connected using with this device. When using a measurement instrument that does not provide isolation between its input terminals and chassis or other input terminals, please pay attention to the following points. If a signal is applied to an input terminal other than that to which the CLAMP ON PROBE is connected, do not connect the ground-side terminal to any non-ground potential. Otherwise, short-circuit current will flow through the CLAMP ON PROBE or this device from the ground terminal, which could cause an electrical accident or damage. CLAMP ON PROBE Chapter 3 Measurement Procedure

9 WARNING Before turning the product on, make sure the source voltage matches that indicated on the rear panel of the product. Connection to an improper supply voltage may damage the product and present an electrical hazard. NOTE (1) Turn the power switch off and connect the power cord. (2) Connect the power plug of the sensor to be used to the power receptacle of the 3272. (3) Turn the 3272 power switch on, and check that the front panel power indicator lights. 3.2 Measurement Procedure See the 3273-50, 3273, 3274, 3275, or 3276 instruction manual. Make sure the sum of the current consumption of the connected CLAMP ON PROBE(s) does not exceed the rated output current of the 3272 (See Fig.1). When using the 3272 with Model 3273-50, 3274, 3275 or 3276 CLAMP ON PROBE, in general only one CLAMP ON PROBE may be connected. However, depending on the current level of the object under test, two CLAMP ON PROBEs may be connected simultaneously. The current consumption of a CLAMP ON PROBE is dependent upon the current level of the object under test. Chapter 3 Measurement Procedure

10 600 500 400 300 200 100 0 AC(f=50Hz) DC 0 10 20 30 40 50 (1) 3273-50 current (A) 600 500 400 300 200 100 0 AC(f=50Hz) DC 0 100 200 300 (2) 3274 current (A) 600 500 400 300 200 100 0 AC(f=50Hz) DC 0 100 200 300 400 500 600 700 (3) 3275 current (A) Chapter 3 Measurement Procedure

11 600 500 400 300 200 100 0 AC(f=50Hz) DC 0 10 20 30 40 50 (4) 3276 current (A) 600 500 400 300 200 100 0 AC(f=50Hz) DC 0 10 20 30 (5) 3273 current (A) Fig.1 Current consumption* vs. current to be measured(typical) *The sum total of a positive and negative current consumption Chapter 3 Measurement Procedure

12 Chapter 3 Measurement Procedure

13 Chapter 4 Description of Parts 4.1 Power Supply Receptacle The pin assignment of the receptacle is shown in the following. 2 3 1 4 1 Not used 2 Ground 3-12 V 4 +12 V 4.2 How to Change the Power Supply Fuse and Change the Power Supply Voltage The power supply fuse for the 3272 unit, and the power supply voltage selector, are housed in the power input socket on the rear panel. Chapter 4 Description of Parts

14 WARNING To avoid electric shock, turn off the power switch and disconnect the clamp on probe before replacing the fuse. Replace the fuse only with one of the specified characteristics and voltage and current ratings. Using a non-specified fuse or shorting the fuse holder may cause a life-threatening hazard. Supply voltage 100 V, 120 V : F1.0 AL/250 V 20 mm x 5 mm dia. 220 V, 240 V : F0.5 AL/250 V 20 mm x 5 mm dia. To change the fuse, or to alter the power supply voltage setting, use the following procedure with reference to the figures. 1. Turn the power switch off, and then remove the power cord. 2. Using a slot head screwdriver or the like, bias sideways the catch which holds the fuse holder into the power input socket as shown in the figure, and then remove the fuse holder. 3. When changing the power supply fuse: Change the power supply fuse for a new one of the same rating and specification. When altering the power supply voltage setting: (1) Remove the voltage selector from the fuse holder, and reinsert it after having rotated it so that the desired new power supply voltage setting appears in the voltage window as shown Chapter 4 Description of Parts

15 in the figure. Then recheck the setting value shown in the voltage window. (The voltage display is upside down and backwards.). (2) Change the power supply fuse for a new one whose rating and specification are appropriate for the new power supply setting. 4. Replace the fuse holder by reinserting it into the power input socket. Power input socket Screwdriver Pry the catch with a slot head screwdriver or the like and remove the fuse holder. Fuse holder Chapter 4 Description of Parts

16 When altering the power supply voltage setting: Voltage selector Fuse holder Remove the voltage selector, rotate it so that the figures which will appear in the voltage window represent the voltage of the power supply which will now be used, and then replace it. When changing the power supply fuse: Fuse holder Voltage window Chapter 4 Description of Parts

HIOKI 3272 POWER SUPPLY Instruction Manual Publication date: December 2007 Revised edition 8 Edited and published by HIOKI E.E. CORPORATION Technical Support Section All inquiries to International Sales and Marketing Department 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL: +81-268-28-0562 / FAX: +81-268-28-0568 E-mail: os-com@hioki.co.jp URL http://www.hioki.com/ Printed in Japan 3272A981-08 All reasonable care has been taken in the production of this manual, but if you find any points which are unclear or in error, please contact your supplier or the International Sales and Marketing Department at HIOKI headquarters. In the interests of product development, the contents of this manual are subject to revision without prior notice. The content of this manual is protected by copyright. No reproduction, duplication or modification of the content is permitted without the authorization of Hioki E.E. Corporation.

HEAD OFFICE 81 Koizumi, Ueda, Nagano 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: os-com@hioki.co.jp URL http://www.hioki.com/ HIOKI USA CORPORATION 6 Corporate Drive, Cranbury, NJ 08512, USA TEL +1-609-409-9109 / FAX +1-609-409-9108 3272A981-08 07-12H Printed on recycled paper