TABLE OF CONTENTS Page

Similar documents
25kV 200A Loadbreak Bushing Insert and Elbow Design Test Report. Report Number:

QS-III. 5513A, 5514A, 5515A and 5516A 15 kv Cold Shrink Inline Splice Kits. Data Sheet CAUTION. 1. Product Description. 2. Applications.

3M Cold Shrink QS-III Inline Splice Kits 15 kv 5513A, 5514A, 5515A and 5516A

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series

Eaton s Cooper Power Systems

3M Cold Shrink 3-Conductor Inline Splice Kits QS-III 5786A- MT, 5787A-MT and 5788A-MT 25/28 kv for use with Armored and Non- Armored 3/C Cable

Product Description: Objective and Certification: Test Samples and Test Cable:

Quick Splice II 5451R. 25/28 kv Molded Rubber Cable Repair Splicing Kit Data Sheet. 1. Product Description. 2. Applications

LV Bushing Oil to Air Dry Insulation PTAB-SLV832

3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series

3M Cold Shrink QT-III Silicone Rubber Termination Kits 7640-T and 7650-T Series 5, 8, 15, 25/28 and 35 kv

High Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide

15kV 200A Loadbreak Fuse Elbow Design Test Report. Report Number:

INSTALLATION PRODUCTION TESTS

Quick Splice II. 35 kv Molded Rubber Inline Splicing Kit Data Sheet. 2. Applications. 1. Product Description

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

CERTIFIED TEST REPORT. Cooper Power Systems. 25 kv Class 200 Amp 15.2/26.3 kv SEPARABLE CONNECTOR SYSTEM

Type MMV-WP Medium Voltage Wind Power Cable

Tests are conducted in accordance with IEEE Standard 386. ac 60 Hz 1 Minute Withstand 50

Deadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

Loadbreak Apparatus Connectors

Loadbreak Apparatus Connectors. 200 A 15 kv Class Loadbreak Elbow Connector with Optional Integral Jacket Seal GENERAL

Low voltage bushings for pad-mounted distribution transformers Technical information guide

Table 1. Sample Identification and Comparison Connectors Used in Experiments Sample Conductor Size

600 A 15 kv class T-OP II deadbreak connector

A. Submit manufacturer's literature and technical data before starting work.

200 A 25 kv and 28 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

200 A 25 and 28 kv class POSI-BREAK loadbreak elbow connector with optional integral jacket seal-canadian Edition

600 A 35 kv class BT-TAP deadbreak connector

I Surge Arresters. UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 GENERAL

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal

GENERAL. CONSTRUCTION External

ANSI DESIGN TEST REPORT Report No. EU 1512-HR-00.5 Type PDV 100 Optima Heavy Duty Distribution Class Surge Arrester

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv

15 kv Class Fused Loadbreak Elbow Connector with Interchangeable Fuse Capability

SPECIFICATION FOR EXTRUDED DIELECTRIC, SHIELDED POWER CABLES RATED 5 THROUGH 46 kv

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

GK-600. Product Classification. Dimensions. Electrical Specifications. Environmental Specifications. General Specifications

OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets

High Voltage Joints and Terminations up to 72,5 kv 145 kv

REPORT OF TEST ON Elastimold Molded Vacuum Reclosers (MVRs)

STEEL CASING OVERHEATING ANALYSIS OF OPERATING POWER PIPE-TYPE CABLES

25 kv class fused loadbreak elbow connector

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

75 OHM COAXIAL CABLE (RG6)

A 1.2 kv class externally removable secondary bushing

600 A 25 kv class BT-TAP deadbreak connector

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

600A Deadbreak Elbow. K656LR Elbow Connector (with Test Point) Features:

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Raychem CSJA Safety Instructions. Safety Instructions. Customer Service. Kit Contents. Installation Instructions

Surge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv

CERTIFIED TEST REPORT

Optima Distribution Class (PDV) and Riser Pole (PVR) Surge Arresters

Not all Low Voltage Switchgear is created equal

25 kv Apparatus Bushings

VariSTAR Type AZG2 Surge Arrester, 10,000 A, Line Discharge Class 2 IEC (99-4)

Surge arresters. UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters. General. COnSTrUCTIOn

GE TRANQUELL Surge Arresters

3M Connector System 0.050" x 0.100" Pitch. 3M Tripolarized Wiremount Socket - Series 820 3M 4-Wall, Tripolarized Header - Series 810

FIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z

1500 kva Padmount Transformer delta Primary Voltage 208Y/120 Secondary Voltage

Cold Shrink Silicone Rubber Termination Kit QT-III 7620-S, 7690-S and 7680-S Series kv

MEDIUM VOLTAGE TERMINATIONS

Jun06 Rev D

600 A 15 and 25 kv class deadbreak accessories, tools, and replacement parts

DLO. Mining Cable. Mining Cable. 2 kv

Section 11 Mining Cable

Easier! Faster! Safer!

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

High-voltage primary bushings installation instructions

copper stud. If a 900 A rating is desired, specify a C as the 8th digit when determining your part number (See Table 3, page 3.)

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv

Future Proof Your Arc Flash Assessment

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.

COOPER POWER SERIES. High-voltage primary bushings installation instructions. OEM Equipment MN800008EN

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8(S)-JCN

Contents. Design Test Results for Specimen Design Test Results for Specimen Voltage Impulse Oscillograms...9

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

3M Cold Shrink QT-III Silicone Rubber Termination

600 A 35 kv class separable splices

Surge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka)

N2XSEBY 3 x (25-300) mm² 3.6/6 kv

15 kv and 25 kv Thru-Bushings

Solid State Relays, 3-phase

Medium Voltage Catalog

Section 6 Electric Metering: Residential

Technical Specification for Pole Mounted Capacitor Rack

AIR CORE REACTORS. Phoenix Electric Corporation

Not all Low Voltage Switchgear is created equal

Product Specification Rev A

AMENDMENT ELECTRIC SERVICE MANUAL 2014

Test report. Type VRLTC load tap changer VRLTC 1500A Type test summary report

600 A 35 kv class deadbreak accessories, tools, and replacement parts

Transcription:

TABLE OF CONTENTS Page Objective 3 Summary 3 Conclusion 3 Sample Preparation 4 Testing 4 Test Results 5 Summary of Test Results (Table 1) 6 Appendix I 7 Addendum 1 8 2

I. OBJECTIVE To evaluate the performance of Raychem NMCK 8 Non-Shielded Stub Type Motor Connection Kit, by testing it to a modified sequence of IEEE-404 1986, the standard for shielded power cable joints. II. SUMMARY A total of three NMCK 8-4V samples were evaluated. Each sample was subjected to a series of voltage withstand tests, followed by load cycling in air, with a long term overvoltage test. Test results are summarized in Table I. III. CONCLUSION This report establishes the performance capability of the NMCK 8 Non-Shielded Stub Type Motor Connection Kit. It also establishes the satisfactory performance of the connection when the cap is in intimate contact with ground. 3

IV. SAMPLE PREPARATION The following cables and accessories were used in the construction of the samples. Motor lead: #6 AWG glass reinforced silicone rubber insulated, 8kV, stranded copper conductor cable. Feeder cable: #2 AWG EPR-NEO 5kV, 133% insulation, metal tape shield stranded copper conductor cable. Lugs: Copper compression, single hole. A standard HVT-80 kit was used to terminate the feeder cable. The lugs were bolted together to form a stub connection. The NMCK 8-4V kit was assembled in accordance with the standard installation instruction PII-57425-0, as provided in the kit. Three such assemblies were constructed. V. TESTING All three samples were subjected to a modified sequence of tests listed in IEEE-404 1986. The tests included AC and DC voltage withstands, impulse withstand, current cycling in air, long term overvoltage followed by AC voltage withstand test. A ground plane was constructed around the stub by wrapping a copper gauze over the cap. This was to simulate a worst case field condition where the stub connection could be in intimate contact with a grounded enclosure. All tests were conducted with the intimate ground plane on the exterior surface. 4

VI. TEST RESULTS 6.1 AC VOLTAGE WITHSTAND A 23kV (rms) 60Hz voltage was applied for one minute between conductor and the external copper gauze ground plane. 6.2 DC VOLTAGE WITHSTAND A 45 kv DC voltage was applied for 15 minutes between conductor and the external copper gauze ground plane. 6.3 IMPULSE VOLTAGE WITHSTAND A nominal 1.2 x 50 µs wave of 55 kv crest was applied between conductor and the external copper gauze ground plane. The samples were subjected to 10 consecutive positive and 10 consecutive negative shots. 6 4 LOAD CYCLING IN AIR The samples were connected in a loop and an induced current of 185A, corresponding to the ampacity required to raise the temperature of a #6 AWG copper conductor to 130 C while in air, was passed through them. The current flow was maintained for a period of eight hours and switched off for the next 16 hours. Samples were continuously energized to 13.8kV. The samples were subjected to 32 such cycles. 6.5 LONG TERM OVER VOLTAGE A 17.3kV (rms) 60Hz voltage was applied for 32 days between the conductor and the external copper gauze ground plane. See Appendix I. 6.6 VOLTAGE WITHSTAND Following the long term overvoltage test, the samples were subjected to a 23kV (rms) 60Hz voltage for a period of 5 hours. 5

TABLE I SUMMARY OF TEST RESULTS TEST TEST REQUIREMENT RESULTS 1. AC voltage withstand 23kV (rms) 60Hz for 1 minute Passed 2. DC voltage withstand 45kV DC for 15 minutes Passed 3. Impulse withstand 1.2 x 50 µ, 55kV crest 10 positive, 10 negative shots Passed 4. Load cycling in air 8 hours on, 16 hours off, 32 cycles, impressed voltage 13.8kV (rms) Passed 5. Long term overvoltage 17.3kV (rms) 60 Hz, for 32 days Passed 6. AC voltage withstand 23kV (rms) 60 Hz, for 5 hours Passed 6

APPENDIX I The accepted industry equation for life prediction by overvoltage testing is: predicted life = test time (test voltage/rated voltage) n where n = a constant usually of the order of 5-6 rated voltage = rated ground to line voltage. The applied voltage of 17.3kV represents 3.5 times rated line to ground voltage. Substituting the data into the equation with n =5 (a very conservative acceleration factor). predicted life = 32 days (3.5) 5 = 32 days x (3.5) 5 = 0.088 years (525.2) = 46 years This implies that the accelerated overvoltage testing performed extrapolates to an equivalent service life of over 40 years. 7

Addendum 1 Applicability of EDR-5190 to NMCK8 Stub Kits Using Molded End Caps The NMCK8-4V (NS) and the NMCK8-5V (NS) were assembled using NMCK-1000 and NMCK-1500 bonded caps. These caps were made from WCSF tubing and coated with S1119 sealant. Because the bonding process is obsolete, it is necessary to convert to molded caps manufactured with the nuclear grade compound designated -52. The molded caps that the NMCK8-4V (NS) and the NMCK8-5V (NS) will utilize are 101A140-52/144 and 101A150-52/144. All other components remain the same. Table 1 below shows the comparison of wall thickness, length, and electrical properties of the two materials. This comparison shows that EDR-5190 is applicable to the NMCK8 stub kits using the molded cap without further testing. The NMCK bonded cap dimensional requirements are listed in SCD-37002 and the electrical properties are listed in Raychem Materials Specification PPS 3010/7. The dimensional requirements for the 101A140-52/144 and 101A150 are listed in SCD-48062 and the electrical properties are listed in Raychem Materials Specification PPS 3011/8. Table 1 NMCK-1000 101A140-52/144 NMCK-1500 101A150-52/144 Bonded Bonded Recovered wall 0.170 0.170 0.170 0.170 thickness Length 10 10 13 13 Dielectric 350@ 0.06 200 350@ 0.06 200 Strength, V/mil (see note) 200@ 0.10 200@ 0.10 Volume Resistivity (see note) 1 x 10 13 ohm cm 1 x 10 13 ohm cm 1 x 10 13 ohm-cm 1 x 10 13 ohm-cm Note: The electrical properties apply to all sizes of caps. 8