AMERICAN MADE X SERIES LED SOLAR LIGHTING SYSTEM: X-35-LED

Similar documents
AMERICAN MADE X SERIES LED SOLAR LIGHTING SYSTEM: X

AMERICAN MADE X SERIES LED SOLAR LIGHTING SYSTEM: X LED-400-T

AMERICAN MADE X SERIES LED SOLAR LIGHTING SYSTEM: X-8800-LED-280-T

AMERICAN MADE X SERIES LED SOLAR LIGHTING SYSTEM: X-3640-LED-185-T

SPECIAL SPECIFICATION 6576 Solar Panel Power Supply System

SPG-400. Solar-powered generators

250 Watt. Features. Positive tolerance Positive tolerance of up to 5% delivers higher outputs reliablity

Solar Electric Modules

Ningbo Star Solar Co.,Ltd Tel:(86) Fax:(86)

General Specifications (Type D)

P H O T O V O LTA I C

LITA General Specifications

SINGLE SUPERA - General Specifications

. 100G. USSL series, MADE IN THE USA Solar street lights

PV Module Installation Manual

Details and specification for 30 W solar powered LED street lights.

General Specifications (20W)

BRIGHTA - General Specifications

Qty: L50 50W. B4 Two 12V 146 Ah. B5 One 12V 176 Ah. P4 150W Double. 4 XXX 4 hours PM 0 hours AM. 5 XXX 6 hours PM 0 hours AM PM4 45 PM6 60.

SOLAR STREET LIGHT SSLX30W SSLX40W SSLX60W

X-SERIES SOLAR PANELS

INDEX. 3 BOREHOLE DC SOLAR PUMPS 3LLS...4 PERIPHERAL VANE DC SOLAR PUMP 3LSQB2...6

: Next Generation Solar LED Solution

INSTALLATION MANUAL. For Monocrystalline Modules. According with IEC61215 edition 2 & IEC61730 standards

Station Identification. Results. PV System Specifications. Energy Specifications. Solar Radiation (kwh/m 2 /day) Energy Value ($) AC Energy (kwh)

SL12 SL12 SOLAR LED STREET / PARKING LOT LIGHT 10W,15W, 20W, 25W LED Lamp & Complete Solar Sytem

IEC INSTALLATION INSTRUCTION AND MAINTENANCE MANUAL FOR CRYSTALLINE SOLAR PV MODULE

SL10 SL10 SOLAR LED STREET / PARKING LOT LIGHT 10W,15W, 20W, 25W LED Lamp & Complete Solar Sytem

LOT Kwp Solar PV Power Solution with Battery Backup

KIT-STCS60D KIT-STCS100D Solar Suitcase 60W and 100W Owner s Manual

18.6% 0-5w. Years. Grid. Certification. BYD PV Module 25 Years Linear Performance Warranty

Shinsung Solar Energy

FL20 Solar Bus Shelter / Transit Light System 10W, 15W, 20W LED Lamp(s) & Complete Solar Sytem

General Specifications

Kaneka K60 60W Thinfilm Solar Panel

SL37 SL37 SOLAR LED STREET / PARKING LOT LIGHT 35W or 65W LED Double Lamp & Complete Solar Sytem

3.6 Kwp Solar system Supply, Installation, Commissioning & Maintenance of Solar Systems to YEMAC office in HADDA street, Sana a city

Product Manual. Installation Instructions for CHSM-230M Series Solar Module

E-SERIES RESIDENTIAL SOLAR PANELS

Wind Energy System.

User Manual. Solar Charge Controller 3KW

SL15 SOLAR STREET / PARKING LOT LIGHT 10, 15, 20, 25, or 30W LED Lamp & Complete Solar Sytem

KIT SOLAR MONTE PERDIDO


PEIMAR S OFFICIAL BROCHURE - USA

Energy & Cost Savings The Friends Meeting of Austin 3701 Martin Luther King Blvd. Austin, TX (46) Sharp 208 W Modules = 9.

Technical standard for AC, DC and street light systems

Photovoltaic Modules Installation Manual for Australia

Installation Manual. Opal Solar QSA Series

Batt Pwr. Batt Mnt. Color LED Luminaire Optics Driver/Load Batt. Box Battery Pwr Batt. Mount Panel Pole Options

PEIMAR S OFFICIAL BROCHURE - UK VERSION

NEW-TEK SCHMID R Company High-tech enterprise for the production of PV solar modules

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

Qty: R4 Type IV Distribution. B4 Two 12V 146 Ah. B5 One 12V 176 Ah. P4 150W Double. 4 XXX 4 hours PM 0 hours AM. 5 XXX 6 hours PM 0 hours AM PM4 45

Solar Power For Your RV

RLH 20 Watt 24V Solar Power Supply

TECHNICAL DESCRIPTION GLOBE XL

Distribution division. Solar Photovoltaic Catalogue. Premier Plaan. Smart solutions for the solar energy sector around the world

Schneider Electric PV Skid. Optimized solar power conversion system tailored to enhance any North American PV power plant

400W / 600W / 1000W / 1500W DIY Wind Turbine

FULLY CERTIFIED ON-TIME DELIVERY ATEC GRP ENCLOSURES

Product Catalogue. Europe

Staff Review Date: March 11, 2015 HDC

DURA-PANEL W OUTPUT: 12 VDC, 20 Watt W OUTPUT: 12 VDC, 50 Watt W OUTPUT: 12 VDC, 100 Watt

Solar LED Luminaires CN Series of Municipal Roadway

User Manual Solar Charge Controller 3KW

Safety and Installation Instructions

SPECIAL SPECIFICATION 8676 Solar Panel Power Supply System

Designing Stand Alone Systems. Overview, components and function, Elements in Design

Sun Sensor setting in PumpScanner Daily output in average month 52 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

Solar inverter AX-series

Billboard LED Solar System STOP! THIS IS IMPORTANT

INSTALLATION MANUALFOR RISEN SOLAR MODULE

eshine Flood Lamps Technical Data

SOLAR BOOST 3024i 30AMP 12/24VDC MAXIMUM POWER POINT TRACKING PHOTOVOLTAIC CHARGE CONTROLLER

䈀刀䤀䜀䠀吀䄀. 䌀漀猀琀䔀 û 攀挀琀椀瘀攀匀漀氀愀爀䰀椀最栀琀椀渀最匀漀氀甀琀椀漀渀猀

Eclipse Solar Suitcase

SOLAR LIGHTING SYSTEM

Heavy industrial LED lighting Champ Pro PFM LED luminaires. Champ PFM. LED floodlights for heavy industrial areas. Authorized Distributor

RPS TL-UL System. Solutions for the North American Solar Market

10KW 3 Phase Off Grid Hybrid System

Battery Chargers - Phase Three Series

Owner s Manual. Contents GP-PWM-10-SQ

MANBLAN Hybrid Powered Landscape Lights SL C-00-5 <Assembly Type>

USER MANUAL - LED Street Light & LED Flood Light. Smart Solar 4G LED Street Light

AC MODULE P72PCS-300W

OSQ Series OSQ LED Area/Flood Luminaire Large

TBARC Programs Solar Panel. 15 Aug 2013 By Israel AD7ND

INSTALLATION MANUAL CRYSTALLINE SOLAR MODULES

KD240GX-LFB2, KD245GX-LFB2 KD250GX-LFB2

SAMPLE PERMIT APPLICATION PACKAGE

Solar Integrated light. Protect your property with the power of sunlight

Owner s Manual. Contents GP-PWM-30-SQ GP-PWM-30-SQ

INSTALLATION AND SAFETY MANUAL for Cigs-2000A1 and Cigs-2000E1 Solar Photovoltaic Modules Release Date: Version: 1.1

Recommended Tools: Phillips & Flat Screwdriver, 17/13/10mm wrench, 8mm nut driver

SOLAR BOOST 2512i(X)-HV

Paseo. Luminaire CE21T4UF Pole PA40 base cover BD11

CONSTRUCTION Aerodynamic aesthetical design optimized for LED characteristics. Modular design for easily installation and maintenance.

INSTALLATION & OPERATION MANUAL

19.0" (482mm) Performance Summary 3.1" (79mm) NanoOptic Precision Delivery Grid optic Receptacle location (ordered as an option)

Transcription:

SYSTEM OUTPUT AMERICAN MADE X SERIES LED SOLAR LIGHTING SYSTEM: X-35-LED-12000-360 12000 LUMENS PER FIXTURE SYSTEM VOLTAGE INPUT 12/24 VDC OUTPUT 12/24 VDC SYSTEM CERTIFICATION - UL compliant system to UL 1598 - CAN/CSA C22.2 No. 250.0 - Dark Sky Compliant OPERATIONAL TEMPERATURES System is operational from -60 Celsius (with un-frozen batteries) to maximum temperature range of 60 Celsius with 90% humidity SOLAR MODULES - High efficiency UL, CUL, and CE listed 360 watts of panel Monocrystalline (if available) - 20 year warranty - Anti-corrosion- salt spray tested BATTERY ENCLOSURE - Aluminum battery enclosure - Pre-wired and tested - Designed for a harsh or marine environment - Thermal resistant powder coated to resist salt water spray and sand - Raised ridge rubber battery mat for thermal battery protection ELECTRONICS - Pre-wired and mounted in battery enclosure box - Triple circuit breaker protected (no fuse replacement) - Maximum Power Point Tracking (MPPT) charge controller is reverse polarity protected and cannot be damaged by wiring incorrectly - Instant light test switch no need to wait for sunset to confirm correct installation LED LIGHT FIXTURE - Dark Sky Compliant - Glass cut off optics TOP OR SIDE OF POLE SOLAR MOUNT Phillips Illumiled 5050 LED Chips 160-170 lumens per watt Color Temperature Options: 4300k (standard option) Aluminum solar array mounting system to provide multiple degrees of adjustments for more precise alignment with the sun GEL PACK BATTERY - Zero maintenance gel pack battery - High capacity deep cycle - 3+ days back up power - Automatic low-voltage shutdown to protect battery - Battery operating temperature: -60 Celsius to 60 Celsius

SLI-75W LED Street & Parking Light, 400W HI D Replacementp Black / white / silver / bronze color housing optional 1-10V / PWM / Resistance dimming optional Specifications Electrical Specifications Model No. Nominal Wattage Nominal Voltage Maximum Current Power Factor (PF) Driver Efficiency SLI-75W 75W 90-305/277-480VAC, 50/60Hz 24VDC AC 0.9A (max) DC 0.3A (max) >0.95 >92% Photometric Specifications Luminous Flux CRI CCT Optional Beam Angle +Lumen tolerance +/- 5% 12000lm Ra>75 3000-6500K 60*150 / 70*150 / 80*150 / 90*100 / 60 / 120 Optional converters for different applications 60mm to wall mount converter Mechanical Specifications IP&IK Rating Lifetime Heat Radiator Lens Fixture Dimension Net Weight Carton Dimension Gross Weight IP66 & IK10 62000 hours - L70, @25 C Anodized Aluminum PC 576*300*107mm 22.7*11.8*4.2 inches 7.5kg 650*370*190mm 8.3kg 2 in 1 converter 4 in 1 converter Round to square converter 80-60mm converter wall mount converter 60-40mm converter

HYUNDAI SOLAR MODULE RI SERIES Multi-Crystalline Type HiS-M310RI HiS-M315RI HiS-M320RI Mono-Crystalline Type HiS-S330RI HiS-S335RI HiS-S340RI HiS-S345RI HiS-S350RI HiS-S355RI HiS-S360RI Cells For Commercial & Utility Applications More Power Generation In Low Light Hyundai Cell, Made in Korea PERL Technology PERL technology provides ultra-high efficiency with better performance in low irradiation. Maximizes installation capacity in limited space. Low LID / PID Both LID(Light Induced Degradation) and PID(Potential Induced Degradation) are strictly eliminated to ensure higher actual yield during lifetime. Mechanical Strength Tempered glass and reinforced frame design withstand rigorous weather conditions such as heavy snow and strong wind. Reliable Warranty Global brand with powerful financial strength provide reliable 25-year warranty. Corrosion Resistant Various tests under harsh environmental conditions such as ammonia and salt-mist passed. UL / VDE Test Labs Hyundai s R&D center is an accredited test laboratory of both UL and VDE. Hyundai s Warranty Provisions About Hyundai Solar 10-Year Product Warranty On materials and workmanship 25-Year Performance Warranty 90% of guaranteed min. power for 10 years 80% of guaranteed min. power for 25 years Established in 1972, Hyundai Heavy Industries (HHI) is one of the most trusted names in the heavy industries sector with 48,000 employees and more than 40 Billion USD in annual sales (2015). As a global leader and innovator, Hyundai Heavy Industries is committed to building a future growth engine by developing and investing heavily in the field of renewable energy. Started as a core business division of HHI, Hyundai Solar (Hyundai Heavy Industries Green Energy) now stands as an independent company and an affiliate of HHI as from December 2016. It is the largest and the longest standing PV cell and module manufacturer in South Korea with 800 MW of module production capacity. We have strong pride in providing high-quality solar PV products to more than 3,000 customers worldwide. Certification www.hhigreen.com Printed Date : 05/2017

Electrical Characteristics Multi-Crystalline Module (HiS-M RI) Mono-Crystalline Module (HiS-S RI) 310 315 320 330 335 340 345 350 355 360 Nominal Output (Pmpp) W 310 315 320 330 335 340 345 350 355 360 Open Circuit Voltage (Voc) V 45.3 45.3 45.5 46.3 46.5 46.7 46.9 47.1 47.3 47.4 Short Circuit Current (Isc) A 8.9 9.0 9.0 9.3 9.4 9.5 9.6 9.6 9.7 9.8 Voltage at Pmax (Vmpp) V 36.0 36.2 36.4 38.0 38.2 38.4 38.6 38.7 38.9 39.1 Current at Pmax (Impp) A 8.6 8.7 8.8 8.7 8.8 8.9 9.0 9.0 9.1 9.2 Module Efficiency % 15.8 16.1 16.4 16.9 17.1 17.4 17.6 17.9 18.1 18.4 Cell Type - 6, multi-crystalline silicon 6, mono-crystalline silicon Maximum System Voltage V 1,000 1,000 Temperature coefficient of Pmax %/K -0.41-0.40 Temperature coefficient of Voc %/K -0.31-0.29 Temperature coefficient of Isc %/K 0.039 0.039 *All data at STC (Standard Test Conditions). Above data may be changed without prior notice. Mechanical Characteristics Installation Safety Guide Dimensions Weight Solar Cells Output Cables 998 mm (39.29)(W) x 1,960 mm (77.17)(L) x 40 mm (1.57)(H) Approx. 22.9 kg (50.5 lbs) 72 cells in series (6 12 matrix) (Hyundai cell, Made in Korea) 4 mm 2 (12AWG) cables with polarized weatherproof connectors, IEC certified (UL listed and UL 4703 certified), Length 1.2 m (47.2) Only qualified personnel should install or perform maintenance. Be aware of dangerous high DC voltage. Do not damage or scratch the rear surface of the module. Do not handle or install modules when they are wet. Junction Box Bypass Diodes Construction IP67, weatherproof, IEC certified (UL listed) 3 bypass diodes to prevent power decrease by partial shade Front : Anti-reflection coated glass, 3.2 mm (0.126) Encapsulant : EVA Back Sheet : Weatherproof film Frame Clear anodized aluminum alloy type 6063 Nominal Operating Cell Temperature 46 C ± 2 Operating Temperature -40 85 C Maximum System Voltage Maximum Reverse Current DC 1,000 V (IEC) DC 1,000 V (UL) 15A (Up to 350W) 20A (Above 355W) Module Diagram (unit : mm) I-V Curves Mono-Crystalline Si Type-Front Side View Multi-Crystalline Si Type-Front Side View Current [A] 1960 1960 430±20 GROUND HOLE MOUNTING HOLE ( ) 1,200mm 4mm 2 CABLE AND CONNECTOR J-BOX 185±20 LABEL 145±20 (+) 1,200mm 4mm 2 CABLE AND CONNECTOR 430 4 x Ø7-L11 MOUNTING HOLES GROUND HOLE Incid. Irrad = 1,000W/m 2 Operating Cell Temp = 5 C Operating Cell Temp = 25 C Operating Cell Temp = 45 C Operating Cell Temp = 65 C 1100 GROUND MARK Current [A] 652 4 x Ø4.2 GROUND HOLES MOUNTING HOLE MOUNTING HOLE Incid. Irrad = 1,000W/m 2 GROUND HOLE 430 Incid. Irrad = 800W/m 2 Incid. Irrad = 600W/m 2 998 998 40±0.3 252 Incid. Irrad = 400W/m 2 10 4 - Ø7 SLOT THRU 11 11 8 Incid. Irrad = 200W/m 2 7 10 6.5 40 35 40 35 67.2 76 80 3 Sales & Marketing 55, Bundang-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, 13591, Korea Tel: +82-31-8006-6910, 6930, 6906 Fax: +82-2-746-7675 Printed Date : 05/2017

SOLAR LIGHTING INTERNATIONAL, INC. SOLARLIGHTINGITL.COM PH +1-803-233-3461 MOUNTS: SLI-TX-2 series Top-of-Pole Mounting (TPM) : SLI, Inc. manufactures and distributes a complete line of mounng kits to accommodate a wide range of off-grid applicaons. From single module top-of-pole mounts to complex mul-panel arrays, our mounng line has the flexibility to meet your mounng needs. Our Top-of-Pole Mounts Feature: Rugged Materials and Construcon, Precision Engineering and Expert Support Pole Selecon: - Determine solar panel or solar array area (SQ. FT) - Select pole size based on selecon guidelines in Table 1. (Solar Lighng Internaonal, Inc. does not supply poles with our mounng kits). Top-of-Pole : Guidelines For Pole Selecon Module Area 15 SQ. FT. Pole Size Depth In Ground Height Above Ground Hole Diameter 2" SCH40 (2-3/8" OD) 30"-36" 48"-72" 8"-12" SLI-TX-2Series: - Available in 2",3",4" and 6" SCH 40 pipe 28 SQ. FT. 3" SCH40 (3-1/2" OD) 36"-42" 48"-72" 12"-16" 35 SQ. FT. 3" SCH40 (3-1/2" OD) 38"-44" 60"-72" 12"-16" 60 SQ. FT. 4" SCH40 (4-1/2" OD) 42"-48" 60"-72" 16"-24" 90 SQ. FT. 6" SCH40 (6-5/8" OD) 48"-60" 60"-84" 24"-30" 120 SQ. FT. 6" SCH40 (6-5/8" OD) 48"-72" 72"-84" 24"-30" Table 1 * Module Area (SQ. FT) = W (Panel Width in FT) x L (Panel Length in FT) * Solar Array Area (SQ. FT) = W (Panel Width in FT) x L (Panel Length in FT) x Number of Panels per Array Photographs are intended to portray typical enclosure appearance, actual appearance my vary. Solar Lighng Internaonal, Inc., Ph. +1-803-233-3461 1877 Sco Futrell Dr, Charloe, North Carolina 28208

SOLAR LIGHTING INTERNATIONAL, INC. SOLARLIGHTINGITL.COM PH +1-803-233-3461 1 Panel Kit Rail 2 Solar Panel 3 L-Bracket (Foot) 4 Cross Pipe 5 Pipe End Cap 6 U-Bolt with Saddle Bracket 1 2 3 4 5 6 Aachment to Panel Kit Rail Aachment to Cross Pipe U-Bolt with Saddle Bracket L-Bracket Cross Pipe Figure 1. Mounng kit components Array Tilt Angle Selecon: SITE LATITUDE: ( In Degrees) FIXED TILT ANGLE U-Bolt with Saddle Bracket L-Bracket Panel Kit Rail Figure 2. Use L-brackets to aach to the panel kit rails and to cross pipe. Table 2. Increase Tilt Angle A Solar Panel Decrease Tilt Angle B Figure 3. Tilt Angle Adjustments: Adjust PV Array Tilt Angle by rotang U-bolts to desired angle. Locate array in an unshaded area facing equator and lted from the horizontal at desired lt angle (See Table 1). Solar arrays in the Northen Hempisphere face South for opmum energy producon. Solar Arrays in the Southern hemisphere face North. When choosing a site, avoid trees, buildings or obstrucons which could cast shadows on the solar modules. This is especially true during the winter months when the arc of the sun is lowest to the horizon. Solar Lighng Internaonal, Inc., Ph. +1-803-233-3461 1877 Sco Futrell Dr, Charloe, North Carolina 28208

FullyAdjustable Solar Lighting Control SLI 3724iX Improve PV Module and Battery Performance with Maximum Power Point Tracking Patented Maximum Power Point Tracking technology allows SLI's 3724iX to increase charge current up to 30% or more compared to conventional charge controllers. Don t waste your money by throwing PV power away! Get the power you paid for with a Solar Boost charge controller. SLI's 3724ix s advanced fully automatic 3-stage charge control system will properly charge flooded lead-acid, AGM and Gell batteries resulting in improved battery performance with less battery maintenance. The dual 15/20 amp rating will deliver up to 15 amps in 24 volt systems, or up to 20 amps in 12 volt systems. An automatic or manual equalize function is also provided to periodically condition flooded lead-acid batteries. To further enhance versatility, a user configurable auxiliary output and Blue Sky Energy s advanced IPN network interface are also included. The user configurable auxiliary output can serve as either a 15/20 amp load controller, or as a 2 amp auxiliary battery charger. The load control feature can be used to limit excessive battery discharge in unattended remote systems, whereas the auxiliary battery charge feature is ideal for charging a separate battery such as the engine start battery in a boat or RV. The auxiliary output can also provide fully adjustable dusk to dawn lighting control. Solar Lighting Intl's advanced Integrated Power Net, or IPN Network, allows up to 8 IPN capable charge controllers to communicate with each other and operate as a single machine rather than separate charge controllers. The IPN network also allows networked controllers to share an optional battery temperature sensor and remote display. The IPN network does not require a display or other special hardware to operate. Patented MPPT Technology Increases Charge Current up to 30% Or More! 15 Amp 24 Volt & 20 Amp 12 Volt Rating Supports A Wide Range Of Applications Optional IPN-ProRemote Display Provides Charge Control & Full-Featured Battery System Monitoring 3-Stage Charge Control with Filtered PWM Output Improves Battery Performance & Life While Minimizing Battery Maintenance Clear Anodized Faceplate, Galvanized Mounting Box & Conformal Coated Electronics Resist Corrosion Automatic or Manual Equalization To Periodically Condition Flooded Lead-Acid Batteries IPN Network Interface Coordinates Multiple Controllers & Shares Optional Battery Temperature Sensor & Display Auxiliary Output Provides 15/20 Amp Load Control Or 2 Amp Auxiliary Battery Charge Lighting Control Provides Separate Post-Dusk & Pre-Dawn timers Full 12 Month Limited Warranty

How Does SLI MPPT Charge Controllers Increase Charge Current? SLI MPPT charge controllers increase charge current by harvesting more PV power. A conventional charge controller simply connects the PV module to the battery when the battery is discharged which can artificially limit how much power a PV module can deliver. Patented SLI Inc. MPPT technology operates the PV module at it s optimum voltage where it can produce the greatest amount of power rather than at battery voltage. The higher power extracted from the module is then provided to the battery as increased charge current. The actual charge current increase you will see varies primarily with module temperature and battery voltage. In comfortable temperatures, current increase typically varies between 10 to 25%, with 30% or more easily achieved with a discharged battery and cooler temperatures. What you can be sure of is that SLI MPPT charge controllers will deliver the highest charge current possible for a given set of operating conditions. Typical 75W PV Module Performance @ STC SPECIFICATIONS Solar Lighting International MPPT 3724 Output Current Rating 20 amp maximum (12V battery & 12V PV s) 15 amp maximum (battery or PV s > 12V nominal) Nominal Battery Voltage PV Input Voltage Power Consumption Charge Algorithm 12 / 24VDC 0.20W typical standby plus 0.40W each for charge ON & Load ON Acceptance Voltage 14.2VDC fixed (range 10.0 40.0VDC ) Float Voltage Equalization Voltage Voltage Setpoint Limit Auxiliary Output Function Aux. Battery charge 13.2VDC fixed (range 10.0 40.0VDC ) 15.2VDC fixed (range 10.0 40.0VDC ) 15.5VDC fixed (range 10.0 40.0VDC ) Single output configurable as either: 20 amp 12V / 15 amp 24V load controller or 2A auxiliary battery charger 2 Amp typical, same charge voltage as primary battery Load Control / (Range 10.0 40.0VDC,or battery amp-hours from full ) Dusk-to-Dawn Cntrl Temperature Compensation Power Conversion Efficiency Physical Configuration and Dimensions Volt/Amp Accuracy/Range Communication Environmental 57VDC maximum (Recommend maximum VOC 3-stage Bulk/Acceptance/Float plus automatic Equalize Variable Post-Dusk and Pre-Dawn timers, Range 0.5-20.0 Hours Optional sensor adjusts charge voltage based on battery temperature 5.00 mv/ C/cell correction factor (Range 0.00 to 8.00 mv/ C/cell ) sensor range 60 to +80 C 97% Typical @ 28 Volt 12 Amp Output Open frame construction with conformal coated electronics mounted to rear of 5.3 x 5.3 (13.5cm x 13.5cm) clear anodized aluminum face plate. Mounts into standard 411/16 (11.9cm) square electrical box which is included. Ammeters 25.0A±0.50% FS Solar Lighting International's proprietary IPN Network interface -40 to +50 C, 10 90% RH non-condensing As a part of our continuous improvement process specifications are subject to change without prior notice. Available From: Voltages double for 24V battery With IPN-ProRemote which may be used as a setup tool only. Charge voltage setpoints may require modification with IPN-ProRemote based on battery manufacturer's recommendations. Current rating and current limit are 20A when charging a 12V battery from nominal 12V PV modules. If PV VOC ever exceeds 30V (>12V nominal PV modules) current rating and current limit become 15A.

Annex to Certificate Registration No. 10000410 QM08 Custom Manufacturing Services, Inc. 142 Brick Street Princeton, WV 24740 United States of America Extended Location Scope 10002998 Custom Manufacturing Services, Inc. 400 Rogers Street Princeton, WV 24740 United States of America The off-site at 400 Rogers Street, Princeton, WV performs the following primary functions: metal fabrication and assembly. This annex (edition: 2012-07-17) is only valid in connection with the above-mentioned certificate. 2 / 2