G SERIES - E TOUCH MIXER / TAP

Similar documents
EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE

INSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

INFRARED TAPS. Important: Electronic taps saving water, saving power, promoting hygiene DB100 DB125 DB150 DB175 DBL200 DBL225 DBL250 DBL275

Installation and Maintenance Guide SF1593 SF1594 B/E ELECTRONIC LAVATORY FAUCET

GREEN & GREEN 1000 ELECTRONIC LAVATORY FAUCET. InstallatIon and maintenance guide

INSTALLATION AND MAINTENANCE GUIDE TUBULAR SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

D28 SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER. D28 B D28 E D28 Dual Power B D28 Dual Power E D28 Box D28 Box E

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

INSTALLATION AND MAINTENANCE GUIDE EXTREME WM WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

ELECTRONIC FLUSH VALVE FOR URINALS jupiter 2040

INFRA RED MONOBLOC SF2601CP (BATTERY OPERATED) INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER

Dolphin Blue Infrared Taps

BC632 / BCL632 BC635 / BC635

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST

DOLPHIN INFRARED TAP DB800 / DB825 TECHNICAL HELPLINE DOLPHINSOLUTIONS.CO.UK DIAMETER PROJECTION TO SPOUT

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

S-9100, S-9200, S-9300, S-9400, S-9700, S-9800

Model 0393-(n)* AUTOMATIC DECK MOUNTED FOAM SOAP DISPENSER FOR EZFILL TOP FILL MULTIFEED KIT WITH 1.32 GAL. (5L) CONTAINER EZFILL FOAM SOAP DISPENSER

BASYS Infrared Sensor Activated

INSTALLATION MANUAL Aplos Single Handle Vessel Bathroom Faucet KEF I toll free: I Kraus USA Inc. I REV

VIVID SLIMLINE FLOOR MOUNTED BATH MIXER PRODUCT CODE: FINISH: VS745 CHR CHROME STYLISH PREMIUM FINISH CONTEMPORARY DESIGN PHOENIX WARRANTY

Quadra Single Lever Mono Basin Mixer. Telephone Parts and Specification

Zenith Aqua Sense Taps

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

Model 0390 EZFILL TOP FILL MULTIFEED KIT WITH 1.32 GAL. (5L) CONTAINER EZFILL KIT* INSTALLATION AND MAINTENANCE GUIDE

Serial Number Purchase Date

ETF-600 Sensor Operated Lavatory Faucet

TOUCH-ACTIVATED URINAL FLUSHING SYSTEM SLIM STYLE PANEL - LARGE (FRONT ACCESS)

AEF-300/300T SERIES SENSOR FAUCET SYSTEMS

LIGATURE RESISTANT SENSOR FAUCET

Technical Information & Warranty

Installation Instructions

Installation Instructions Melba Sink Mixer

Installation must be in Accordance with AS/NZS

Installation Instructions

Installation IMPORTANT! Aerada 900 Series Futura Faucet With Accu-Zone (AZ) Infrared Control

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

AUTOMATIC FAUCET INSTRUCTION MANUAL. Important Safeguards Precautions Model Number and Components. Before Use How to Use How to Adjust

TOUCH-ACTIVATED DUAL FLUSH WC FLUSHING SYSTEM - FRONT ACCESS

Your Guide to the Installation, Care and maintenance of PERFORMA. Electronic Self Closing Fittings - Mains Powered 886V (343029) 885V (343027)

INSTALLATION INSTRUCTIONS STUDIO S

Installation Instructions

G2 Optima Plus Flushometer

RUSH SHOWER/BATH DIVERTER MIXER PRODUCT CODE: FINISH: RU791 CHR CHROME CONTEMPORARY DESIGN PHOENIX WARRANTY STYLISH PREMIUM CHROME FINISH

Installation Instructions Blitz Tap Range

GLOSS WALL BATH SET PRODUCT CODE: FINISH: GS783 CHR CHROME CONTEMPORARY DESIGN PHOENIX WARRANTY STYLISH PREMIUM CHROME FINISH MATCH WITH...

6-12 WIDESPREAD 6-12 W. Cleopatra Series INSTRUCTION GUIDE SAVE THIS INSTRUCTION GUIDE

Installation Instructions

Aplos Single Lever Basin Faucet

Installation Instructions

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

Installation Instructions Cobalt Tap Range

OMIKA. it s a personal experience. Installation Guide Wall Mounted Basin Mixer. This instruction booklet covers this model: OMI-109.

LIMITED WARRANTY. Exposed Urinal Flushometer for 1-1/4" Top Spud MODEL 180 Exposed Urinal Flushometer for 3/4" Top Spud MODEL 186

SERIES II WALVIT + CUBE. 1.28/0.8 Gal (4.8/3 Litre)

HANDS FREE FOOT & KNEE OPERATED TAPWARE

CW-2651 (WL1100) CB-2651 (BL1100)

Ligature Resistant Stainless Steel. Basin Powder Coated White ADA Compliant

3.0 INSTALLATION INSTRUCTIONS. Avon 21 Self-closing taps (Push button) B0992AA Self-closing basin pillar tap

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate!

Installation Instructions

Installation For Service Only

INSTALLATION MANUAL. Installation Details Warranty Wolfen Pre Rinse Sink Mixer Wolfen Compact Pre Rinse Sink Mixer

DYNAFLUID 2000 STEAM & WATER MIXING VALVE INSTALLATION & OPERATING MANUAL

Installation. Tools. Single Handle Kitchen Faucet With Optional Spray. Maintenance. Safety Tips. Important Points. Need Help? For Model:

Instruction Booklet. P.O. Box Berkeley Rd UNANDERRA,NSW 2526 Australia Tel:

RUSH WALL TOP ASSEMBLIES EXT D 15MM PRODUCT CODE: FINISH: RU067 MB MATTE BLACK 3/4 TURN OPERATION PREMIUM FINISHES

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

Basic Parts Description Size Page Stock No.

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

Acura TMV3 Bath Filler AC50010CP and AC50020CP

INSTALLATION INSTRUCTIONS

MAC FAUCETS. FA400 Autoluxe Faucets

Installation Instructions

Installation Instructions / Warranty

SECTION 4 - FUEL SYSTEMS AND CARBURETION

AC109L-2 (Ornate Metal Lever) AC109LM-2 (Classic Metal Lever) AC109X-2 (Cross Handle) AC109LP-2 (Ornate Porcelain Lever)

Installation Instructions

3.0 INSTALLATION INSTRUCTIONS. Piccolo 21 Single lever Monobloc basin mixers. B0997AA Single lever basin monobloc mixer with long length lever handle,

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

Installation Instructions

Operating Manual for Three-Person Hands-Free Floor Mounted Wash Stations AC Models 56FAL and 56FAL-0.5 Battery Models 56FBL and 56FBL-0.

INSTALLATION INSTRUCTIONS

Single Lever Pull-Out Kitchen Faucet

Prism Floor Standing Bath Shower Mixer

AutoFaucet. with Surround Sensor Technology. Installation & Maintenance

A1004LV. Polished Chrome Polished Nickel Satin Nickel Ø1 1/32 2 1/8

INSTALLATION GUIDE KPF Single Lever Kitchen Faucet With Pull-Out Sprayer

Installation Instructions Series

FULL BORE PERFORMANCE EXHAUST MANIFOLDS F-150 ECOBOOST 3.5L

Ino Single Handle Basin Bathroom Faucet

ROMAN TUB 3 VALVE LONG STEM AND TRIM INSTALLATION INSTRUCTIONS Valve Body No Trim Kit for Model No s: 1047, 1707, 1727

Fig.01 Fig.02 Fig.03. Disassembly & Reassembly Instructions SBV-HP - Page 3

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain

Installation Instructions 7024

Installation Instructions and User Guide

Installation Instructions

WATER SOFTENER SERIES DAY TIMER INSTALLATION & OPERATING INSTRUCTIONS. Serial No :

Transcription:

PLUMBERS Installation and maintenance INSTRUCTIONS G SERIES - E TOUCH MIXER / TAP electronically operated MIXER / TAP G Series E Touch Basin Tap G Series E Touch Basin Mixer 1 IS1301C (03/15)

INDEX 3 IMPORTANT 4-5 TECHNICAL DATA 6 OPERATION 7-8 PACK CONTENTS 9 PRE-INSTALLATION INFORMATION 10-12 MIXER OR TAP INSTALLATION 13-15 FLOW TIME ADJUSTMENT 16 BATTERY REPLACEMENT INSTRUCTIONS 17 MAINTENANCE Filter cleaning instructions Care and cleaning of chrome and special finishes 18 SERVICE CHECK LIST 19 SPARE PARTS LIST

IMPORTANT Pressure & Temperature Requirements 1. Hot and cold water inlet pressures should be equal. 2. Static inlet pressure range: 150-800 kpa - New Regulation: 500 kpa maximum static pressure at any outlet within a building (Ref. AS/NZS 3500.1-2003, Clause 3.3.4) 3. Maximum hot water temperature: 70 C Deck Requirements 1. Deck thickness: 35mm maximum 2. Tap body hole (in deck): Ø34-Ø36mm Power Requirements Battery operation: IP67 Battery Back Up Box (9V batteries not included) Mains operation: 240V 50Hz 3 pin socket Important Information 1. Not suitable for gravity feed systems 2. Tapware is fitted with a flow regulated aerator insert. This low flow rate may not be suitable for connection to some instantaneous Gas Water Heaters, some Tempering Valves, some Solar Water Heaters & some Thermostatic Mixing Valves. Check with the manufacturers of these products. 3. Isolating stop taps must be fitted to the hot & cold water supply connections. (Part No. 842018C - Mini cistern 1/4T) 4. All pipework must be thoroughly flushed prior to installation, as foreign materials may block the flow regulating device and reduce the flow of water. 5. Flexible tails have a left hand thread connection to tap/mixer body. Rotate clockwise to remove. Technical Data 1. Activation: Touch (Piezo technology) 2. Default flow time: 8 seconds (Adjustable) 3. Flow time range: 1-60 seconds (Programmable) 3

Technical data 44 44 94 170 50 92 1 8 G-Series E Touch Basin Tap G16002E6A G-Series E Touch Basin Mixer G16000E6A 103 94 170 50 92 1 8 58 IP67 Battery Back Up Box SP63020 G Series Touch PS 9V SP63025 4

OPERATION Battery and Mains Options To operate this mixer or tap, simply touch the designated area at the piezo cap. Default flow time is 8 seconds. If you do not need more water, just touch the designated area again to stop the water flow before the default flow time has passed. 5

Pack contents E TOUCH BASIN TAP Familiarise yourself with the part names and confirm that the parts are included. 1x Basin tap and attachments 1x Filter washer 1x Allen key battery BACK UP 9V Battery box MAINS OPTION Transformer OPTIONAL BATTERY BOX: IP67 Battery Box 6

Pack contents E TOUCH BASIN MIXER 1x Mixer and attachments 2 x Filter washers 1x Allen key battery BACK UP 9V Battery box MAINS OPTION Transformer OPTIONAL BATTERY BOX: IP67 Battery Box 7

PRE-INSTALLATION INFORMATION Check contents Separate all parts from packaging and check each part with the Pack Contents section. Make sure all parts are accounted for before discarding any packaging material. If any parts are missing, do not attempt to install your mixer or tap until you obtain the missing parts. Preparation for Installation: Important: All pipework must be thoroughly flushed prior to installation, as foreign materials may block the flow regulating device and reduce the flow of water. Ø34mm min Ø36mm max 8

MIXER OR TAP INSTALLATION Step 1 Preparation for mounting the MIXER OR TAP 1 Shut off the water supply. 2 Remove the hexagonal nut, the disc and the gasket. Do not remove the O-ring from the base of the mixer or tap. O-RING gasket disc nut Step 2 Installing the MIXER OR TAP 1 Insert the inlet connection end of each flexible tail through the hole in the deck then place tap over deck hole. Make sure the O-ring is located between the deck and the bottom of the mixer or tap. O-RING O-RING O-RING 2 Slide the gasket and disc onto the threaded stud then screw on the hexagonal nut and tighten. gasket disc gasket disc nut nut 9

mixer or tap installation Step 3 Connecting the water supply 1 Flush lines, fit filter washer and connect the flexible tails to the water supply and tighten to compress the sealing washer to provide a watertight joint. For models with temperature control connect the red flexible tail to the hot water supply and the blue flexible tail to the cold water supply. Important: Flexible tails must not be kinked, twisted or in tension when installed. (Minimum bend radius = 50mm). Do not install flexible tails where subject to ultra violet light. 2 INLETS VERSION 1 INLET VERSION FLEX TAILS FILTER WASHERS ISOLATING STOP TAPS Code : 842018C Make sure that the filter WASHER(s) is/are installed between The flexible TAIL and the ISOLATING STOP TAP (not supplied). 2 Turn on the central water supply and the isolating stop taps and check for leaks. 10

MIXER OR TAP INSTALLATION Step 4 Connecting the power source (MAINS OPTION) MAINS OPTION Plug the transformer into the electricity socket and connect the connectors. 1 BATTERY VERSION Install the battery box at the wall underneath the sink using the two sided adhesive foam tape. The cable connection must point down. 2 In order to avoid entering into the adjusting mode, wait 10 seconds before operating the mixer or tap. If the range is unsatisfactory, refer to the section titled settings adjustment ABOUT 10 seconds 11

FLOW TIME ADJUSTMENT Adjustment levels The flow time is programmable on site. If necessary, the default flow time of 8 seconds can be adjusted to any value between 1 to 60 seconds. The adjustment mechanism is composed of 3 adjustment levels for changing the flow time. An indicator light (LED) will guide you from one level to the other. The following table shows the number of steps in each level, the duration of each step and how to recognize in what adjusting level you are. Level 1 Level 2 Level 3 Out of adjusting mode No. of steps Seconds to be increased by touching once 10 steps 10 steps 2 steps 1 second 2 seconds 15 seconds Adjustment level indicator After entering into adjusting mode level 1 is reached Indicator light blinks twice Indicator light blinks 3 times Indicator light blinks 4 times The following examples show how to manage the adjustment levels: Example 1: You wish to adjust the flow time to 20 seconds. At level 1 perform 3 steps of 1 second (you will get 3 seconds). Total: 3 seconds Go to level 2 and perform 1 step of 2 seconds (you will get 2 seconds). Total: 5 seconds) Go to level 3 and perform 1 step of 15 seconds (you will get 15 seconds). Total: 20 seconds. Example 2: You wish to adjust the flow time to 45 seconds. At level 1 perform 1 step of 1 second (you will get 1 second). Total: 1 second Go to level 2 and perform 7 steps of 2 seconds (you will get 14 seconds). Total: 15 seconds) Go to level 3 and perform 2 steps of 15 seconds (you will get 30 seconds). Total: 45 seconds. 12

FLOW TIME ADJUSTMENT Example 3: You wish to adjust the flow time to 60 seconds. At level 1 perform 10 steps of 1 second (you will get 10 seconds). Total: 10 seconds Go to level 2 and perform 10 steps of 2 seconds (you will get 20 seconds). Total: 30 seconds) Go to level 3 and perform 2 steps of 15 seconds (you will get 30 seconds). Total: 60 seconds. How to adjust the flow time in your battery and mains options 1) Open the piezo cap using the provided 2 mm Allen key. 2) Disconnect the power supply (batteries or transformer). 3) While the power source is disconnected, verify that the solenoid valve is installed and touch the piezo cap twice. 4) Then, reconnect the power supply. 5) The indicator light (LED) on the back of the Piezo cap will start blinking. After a few blinks the LED will give a steady red light. Touch the Piezo cap when the steady red light is still on to enter into the adjusting mode. When done correctly, the light will stop blinking. Note: If you will not press at the indicated area, the previous adjustment will remain. 6) By touching the Piezo cap the new flow time will be programmed. In adjusting mode level 1, each touch increases the flow time by 1 second with a maximum of 10 seconds. You will see the LED blinking every time that a new step is performed. 7) If your desired flow time is within 10 seconds, no other adjusting levels are needed and you can stop pressing the Piezo cap. The LED will blink 2 times, then 3 times and after 4 times you will leave the adjusting mode. The mixer or tap is now adjusted to the desired flow time. 13

FLOW TIME ADJUSTMENT 8) If you need to perform steps at adjusting level 2, wait after you see the LED blink twice and then, perform the needed quantity of steps (with a maximum of 10 steps of 2 seconds). If you do not need more levels, stop pressing. The indicator light will blink 3 times and after 4 times you will leave the adjusting mode. The mixer or tap is now adjusted to the desired flow time. 9) If you need to perform steps at adjusting level 3, wait after you see the LED blink 3 times and then, perform the needed quantity of steps (with a maximum of 2 steps of 15 seconds). 10) To leave the adjusting mode wait until the LED blinks 4 times. Your mixer or tap is adjusted to the desired flow time. 14

BATTERY REPLACEMENT When the battery weakens, the red indicator light will blink at a constant rate. The battery must be replaced within two weeks. OLD BATTERY 1 Carefully open the battery box. 2 Remove the old battery. NEW BATTERY 3 Replace the used battery with a new 9V battery (Lithium battery is recommended). 4 Close the box 15

MAINTENANCE Filter cleaning instructions The tap is provided with one / two stainless steel filter washer(s) preventing foreign particles from entering the lines. If the water flow has decreased, this may be because the filter washer(s) is / are clogged. The filter washer can be cleaned as follows: 1. Shut-off the water isolating stop tap. 2. Disconnect the flexible tail(s). 3. Remove the filter washer(s) and wash it/them under running water. 4. Reassemble the parts. 5. Make sure that there is no water leakage. Care and cleaning of chrome and special finishes DO NOT use steel wool or cleansing agents containing alcohol, acid, abrasives, or the like. Use of any prohibited cleaning or maintenance products or substances could damage the surface of the mixer or tap. For surface cleaning of mixer or tap use ONLY soap and water, then wipe dry with clean cloth or towel. When cleaning bathroom tile, the mixer or tap should be protected from any splattering of harsh cleansers. 16

Service Check List Check the batteries. Low or used up batteries. Replace the batteries. See page 16. Check the flow time. See page 13. Check the connection between the piezo cap connector and the solenoid connector. Check that the battery box is correctly connected. No water is coming out of the mixer or tap Check the solenoid valve. If debris or scale are present, unscrew the solenoid valve, pull out the plunger and the spring and clean them. Use scale remover if needed. When replacing the spring, make sure that it is in vertical position. Check the diaphragm. If needed, clean the orifice or replace it. Check the water supply pressure. It must be 50-800kPa (7-116 PSI). With water pressure of more than 800kPa, use a pressure reducing valve. Check the flow time. If needed adjust it following the instructions at page 13. Check the solenoid valve. If debris or scale is present, unscrew the solenoid valve, pull out the plunger and the spring and clean them. Water flow does not stop Use scale remover if needed. When replacing the spring, make sure that it is in vertical position. Water flow diminished Check the filter washer(s). If needed, remove it, clean it and reinstall it. See page 17. 17

Spare Parts List Part Name Part code IP67 Battery Back Up Box Solenoid G Series Touch Power Supply 9V Optional G Series Touch Battery Box SP63020 SP63019 SP63025 SP63013 18