Application Specification.062 Diameter Pin and Socket Contacts and Housings 21 MAR 11 Rev E

Similar documents
Commercial MATE-N-LOK* Pin and Socket Contacts

Standard Timer Connectors

FASTON* 110 Series. Receptacle With F Crimp Insulation Support Barrel. Wire Barrel. Insulation Support Barrel. Figure 1

3.18-mm [.125-in.] POWERBAND* Contacts

Power Double Lock Connector System

Series 110 MK III, Series 187 MK II and MK III, Series 250 MK II, MK III, and RAST 5 & 7

FASTON* High Temperature Tab Terminals

JUL 14 Rev B

POWER TRIPLE LOCK* Connector System

Coaxial Snap-Lock Connectors

Application Specification Pin&3Pin Miniature waterproof connector 28July2016 REV: C

Economy Power (EP) 2.5 Contacts; Plug and Receptacle Housings; and Vertical and Right-Angle Headers

AMPLIMITE* HDP- 20 and Economy

PLASTI-GRIP* Terminals and Splices

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

VAL-U-LOK* Series Headers, Connectors, and TPA Accessories

FAKRA-Comliant SMB 50-Ohm Inline Connectors 27 JUN 11 Rev E

Underground Bus Bar Distribution System 03 SEP 13 Rev B

Universal MATE-N-LOK* Connectors

FAKRA Automated In-Line Connector System

Position Cat6 Shielded. Modular Plug Connectors. Application Specification

Product Specifications (for connectors) and (for headers), provides product performance requirements and test result information.

FAKRA-Compliant SMB Gen-4 Connector System

AMPSEAL 16* Connector System 24 JUN 13 Rev C

Application Specification

8-Position Cat5E EMT Shielded Slim-Line Modular Plug

Instruction Sheet Crimping Die Assemblies , , and

MAR 11 Rev H

Heavy Duty Electric Hydraulic Pumps PN and

Heavy Duty Miniature Quick-Change Applicator (Side-Feed Type) with Mechanical or Air Feed Systems

JUL 17 Rev M

Micro MATE N LOK* Connectors

Ø1,5mm System Rev G EC: EGA

11DIA SQUIB CONNECTOR COMPACT TYPE

Quick Reference Guide AMP CT Connector Series

OCT2016 Rev A

Solder Assembly Kit

Ocean Side-Feed Applicators

PMC2003 Harness Assemblies

Heavy Duty Miniature Quick-Change Applicator (End-Feed Type) with Mechanical or Air-Feed Systems

APPLICATION SPECIFICATION

2. Use Extraction Tool (contact extraction tool). Insert releasing tip into the REAR of the. cavity between the spring and center wall of the

Hydraulic Hand Crimping Tool, PN

Apr11 Rev A

Quick Reference Guide 1.5 mm AMP Mini CT Connector Series

Battery Powered Hydraulic Pump; Kit PN [ ]

SEP 2016 Rev D2

APPLICATION SPECIFICATION

APPLICATION SPECIFICATION

JAN 18 Rev E

Tooling Assistance Center

PREMIUM QUALITY MANUFACTURING OF CRIMP CONNECTIONS AMP 3K, 5K, GII AND GII + TERMINATORS

May08 Rev C

AUG 18 Rev M

PREMIUM QUALITY MANUFACTURING OF CRIMP CONNECTIONS AMP 3K, 5K, GII AND GII + TERMINATORS

MEZALOK* Stacking Connector System

May2015 Rev A

EVERCLEAR* Mini-SAS Connector System

ECONOMY POWER 2.5 CONNECTORS

AMPLIMITE.050 Series Cable Assemblies, Series III

ELB ES. Product Installation Instructions

T2 Terminator Tooling Specification Sheet Part No

UNSIGNED HARDCOPY NOT CONTROLLED

Jun06 Rev D

FEB 15 Rev C

Connector Installation Guide Compression and Mechanical Connectors

Jun 20,2014 Rev A

I N F O R M A T I O N

This specification covers performance, tests and quality requirem ents for VAL-U-LOK* Connectors.

Class 1 Inline Connector, 6pol.JPT-A- / 10pol.MT II-A-, sealed

APPLICATION SPECIFICATION

SFP Connector and Cage Assemblies

Test Group Description. Total Number. Figure 1. Unless otherwise stated, the following environmental conditions prevailed during testing:

Micro Pneumatic Tooling Assembly;

Application Tooling Specification Sheet

: Test Specification (AMP Test Specifications vs EIA and IEC Test Methods)

Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel. Model Installation Guide

HVP deg 1pos Plug&Header Connector Assy APPLICATION SPECIFICATION

Assembly Instruction. EL OCHITO BLUE CONTACTS SuperSpeed USB TYPE I: PIN /SKT CABLE:

Aug07 Rev A All Paragraphs Revised

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

Fine Pitch SMT Stacking Connectors (Parallel Board-to-Board) Fine Pitch SMT Stacking Connectors (Parallel Board-to-Board) Stacking Height mm inch

Demarcation Fuse/Circuit Breaker Alarm Panel 125DM08. Installation Guide

Assembly Instruction EL OCHITO WHITE CONTACTS 1000BASE-T/10GBASE-T TYPE I: PIN /SKT CABLE: S/FTP

Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel. Model N Installation Guide

HDD Insert Series. Application Specification Apr 30 th, 2017 Rev. A. Table of contents

HD Insert Series. Application Specification Apr 30 th, 2017 Rev. A. Table of contents

Installation Instructions

Powerlock Termination Guide

Instruction Sheet 39mm Patch Panel MT RJ Jack Kits [ ], [ ], and [ ]

ELB ELB

CM52 Network Protector with Arc Flash Reduction Module

UNITED STATES COAST GUARD OCEAN ENGINEERING DIVISION WASHINGTON, D.C. JANUARY 2011 SPECIFICATION FOR THE MANUFACTURE

BH CONNECTOR. 1Certified LR Disconnectable Crimp style connectors. Features. Specifications. Standards. 4.0/8.0/12.0mm

9200 Revenue Meter. Model Certification Current Inputs. Complies with the accuracy requirements of the ANSI C Revenue Metering Standard

Raychem CSJA Safety Instructions. Safety Instructions. Customer Service. Kit Contents. Installation Instructions

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

Tooling Assistance Center

50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel

BH-1 modular fuse blocks, 700 V, 400 A

Transcription:

Application Specification.062 Diameter Pin and Socket 114-1013 Contacts and Housings 21 MAR 11 Rev E i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_. Figures and illustrations are foridentification only and are not drawn to scale. 1. INTRODUCTION This specification covers the requirements for application of.062 Diameter Pin and Socket Contacts and Housings. Requirements are applicable to hand or automatic machine crimping tools. When corresponding with TE Connectivity Personnel, use the terminology provided in this specification to help facilitate your inquiry for information. Basic terms and features of components are provided in Figure 1. Insulation Barrel Wire Barrel Wire Barrel Seam Locking Lances Plug Socket Contact Shown Polarization Mounting Ear Rear Bellmouth Front Bellmouth Receptacle Cutoff Tab and Burr Contact Stop Embossment Polarization Mounting Ear Detent Figure 1 2. REFERENCE MATERIAL 2.1. Revision Summary This paragraph is reserved for a revision summary of changes and additions made to this specification. The following changes have been made for this revision: S Updated document to corporate requirements S New logo 2.2. Customer Assistance Reference Part Number 350628 and Product Code 2133 are representative numbers of the.062 Diameter product line. Use of these numbers will identify the product line and expedite your inquiries through a service network established to help you obtain product and tooling information. Such information can be obtained through a local TE Representative or, after purchase, by calling the Tooling Assistance Center or the PRODUCT INFORMATION numbers at the bottom of this page. 2.3. Drawings Customer Drawings for specific products are available from the responsible TE Engineering department via the service network. The information contained in the Customer Drawings takes priority if there is a conflict with this specification or with any other technical documentation supplied by TE. E2011 Tyco Electronics Corporation, a TE Connectivity Ltd. Company TOOLING ASSISTANCE CENTER 1-800 -722-1111 All Rights Reserved PRODUCT INFORMATION 1-800 -522-6752 TE logo is a trademark. *Trademark. Other product names, logos, or company names might be trademarks of their respective owners. This controlled document is subject to change. For latest revision and Regional Customer Service, visit our website at www.te.com 1 of 5 LOC B

2.4. Specifications Product Specification 108--1037 provides applicable performance requirements for the contacts. 2.5. Instructional Material The following list includes instruction sheets (408--series) that provide assembly procedures for product, operation, maintenance and repair of tooling; and customer manuals (409--series) that provides setup, operation, and maintenance of machines. Document Number Document Title 408--8040 Heavy Duty Miniature Quick--Change Applicators (Side Feed) 466686--[ ] 408--4370 Extraction Tool 318831--1 408--7347 Insertion Tool 91002--1 408--9965 PRO--CRIMPER* III Hand Tool Assembly 90870--1 with Die 408--9964 PRO--CRIMPER III Hand Tool Assembly 90869--1 with Die 408--4390 Applicator 2000 (For Side--Feed Applicators) 409--5128 AMP--O--LECTRIC* Model K Terminating Machine 565435--[ ] 409--5842 AMP--O--LECTRIC Model G Terminating Machine 354500--[ ] 114-1013 3. REQUIREMENTS 3.1. Wire Preparation A. Wire Selection The contacts will accept stranded wire ranging in size from 18 to 30 AWG. Wire insulation diameter shall have minimum and maximum dimensions according to the wire sizes indicated in Figure 2. B. Wire Preparation The wire strip length shall be as indicated in Figure 2. Reasonable care shall be taken during the stripping operation to ensure the conductor is not nicked, scraped, or cut. 3.2. Crimped Contacts Contacts shall be crimped in accordance with the material packaged with the tooling; refer to Figure 5. The applied crimp dimension (within the function range of the product) is dependent on the termination tooling being used. Refer to the documentation (applicator logs and instruction sheets) supplied with the termination tooling for the applied crimp height. See Section 5, TOOLING. A. Carrier Cutoff Tab Cutoff tab shall not exceed 0.38 [.015]. SIZE (AWG) WIRE CRIMP DIMENSIONS WIRE WIRE BARREL INSULATION BARREL INSULATION DIAMETER STRIP LENGTH CRIMP HEIGHT 0.05 [.002] CRIMP WIDTH CRIMP HEIGHT (REF) 30 1.52 [.060] 3.05 0.58 to 0.64 [.023 to.025] 1.07 2.29 28 Max. [.120] [.042] [.090] 0.58 to 0.64 [.023 to.025] Max. 26 0.64 to 0.71 [.025 to.028] 24 0.64 to 0.71 [.025 to.028] 24 1.27-2.79 22 [.050 -.110] 20 0.99 to 1.02 [.039 to.040] 18 0.99 to 1.19 [.039 to.047] Figure 2 CRIMP WIDTH (REF) 1.78 [.070] 0.81 to 0.84 [.032 to.033] 1.40 2.79 0.81 to 0.91 [.032 to.036] [.055] [.110] 2 of 5 Rev E

114-1013 B. Wire Barrel Crimp Inspection 1. Crimp height and width shall be as shown in Figure 2. 2. The wire barrel seam shall be closed adequately to confine all strands of the wire. There shall be no loose wire strands. Wire strands should not be embedded in the seam of the wire barrel. 3. The rear bellmouth shall be 0.13--0.76 [.005--.030]. The front bellmouth shall be 0.24 [.010] maximum. 4. The end of the wire shall be flush with the front end of the wire barrel, or extend 1.02 [.040] maximum. Both insulation and conductor shall be visible between the insulation barrel and wire barrel. Care shall be taken not to allow insulation to be crimped in the wire barrel. C. Insulation Barrel Crimp Inspection 1. Crimp height and width shall be as shown in Figure 2. 2. Care shall be taken not to cut or break the insulation during the crimping operation. D. Alignment The crimped insulation barrel shall fall into an area defined by a 3.25 [.128] diameter circle. See Figure 3. There shall be no twist or roll in crimped portion that will impair usage of the contact. Figure 3 3.3. Housings Housings are available in receptacle and plug versions. Receptacles are available with mounting ears and detents or with detent only. Plugs are available with or without mounting ears. 3.4. Panel- Mounting Cutouts Panel--mounting cutouts shall be as indicated in Figure 4. A B NUMBER OF DIMENSIONS CIRCUIT RECEPTACLE PLUG POSITIONS A B A B 2 6.73 [.265] 12.83 [.505] 8.08 [.318] 15.47 [.609] 3 6.73 [.265] 16.51 [.650] 8.08 [.318] 19.15 [.754] 4 SQUARE 10.16 [.400] 12.85 [.506] 11.81 [.465] 15.62 [.615] 4 IN -LINE 6.60 [.260] 19.94 [.785] 7.92 [.312] 21.97 [.865] 6 12.83 [.505] 14.02 [.552] 15.42 [.607] 15.62 [.615] 9 14.02 [.552] 16.51 [.650] 15.62 [.615] 19.10 [.752] Recommended Cutout for 1.52 [.060] Max. Thick Panel Figure 4 Rev E 3 of 5

3.5. Repair 114-1013 Connectors can be repaired by removing the contact from the housing and making the repair. When extracting a contact, the lances should be reset to their original position. Consult the customer print for the correct setting. See SECTION 5 for tooling. 4. QUALIFICATIONS The.062 Diameter Housings are Recognized by Underwriters Laboratories Inc. in UL File Number E28476 and Certified by CSA International in File number LR7189. 5. TOOLING (Figure 5) The.062 Diameter Contacts are terminated by automatic machine or hand crimping tools. Figure 2 lists tooling used for crimping these contacts. Use Insertion Tool 91002 (408--7347) to insert crimped pin and socket contacts in housing. Use Extraction Tool 318831--1 (408--4370) to remove pin and socket contacts from the housing. The Model K AMP -O -LECTRIC Terminating Machine PN 565435-5 has been superseded by the Model G Terminating Machine PN 354500-1 for new applications. For existing applications, the Model K is still recommended because of the large number of installed machines. Quick -Change Miniature Applicator (408-8040) Extraction Tool 318831-1 (408-4370) Applicator 2000 (For Side -Feed Applicators) (408-4390) AMP -O -LECTRIC Model G Terminating Machine 354500 -[ ] (409-5842) Insertion Tool 91002-1 (408-7347) PRO -CRIMPER II Hand Tool 90870-1 (408-9965) AMP -O -LECTRIC Model K Terminating Unit 565435 -[ ] (409-5128) WIRE APPLICATOR POWER UNIT HAND TOOL SIZE (AWG) INSULATION DIA (Instruction Sheet 408-8040) 8040) (DOCUMENT) (DOCUMENT) 30 1.52 [.060] 466686 -[ ]D 354500-1 (409-5842) 90870-1 28 Max. or 565435-5 (409-5128) (408-9965) 26 24 24 1.27-2.79 687996 -[ ]D 1016021-1 (408-4390) 90869-1 22 [.050-110] (408-9964) 20 18 D Use dash 1 ( -1) for a T type machine and dash 2 ( -2) for a K type machine. Figure 5 4 of 5 Rev E

114-1013 6. VISUAL AID (Figure 6) The following illustrations are to be used by production personnel to ensure properly applied product. The views suggest requirements for good applications. Applications considered visually incorrect should be inspected using the information in the main body of this document WIRE STRANDS AND INSULATION MUST BOTH BE VISIBLE ANYWHERE IN THIS AREA LOCKING LANCE NOT DEFORMED BELLMOUTH MUST BE VISIBLE WIRE STRANDS MUST BE VISIBLE ANYWHERE IN THIS AREA CUTOFF TAB MUST BE VISIBLE MOUNTING EARS LOCKED ONTO PANEL DETENTS POSITIVELY LOCKED FIGURE 6. VISUAL AID Rev E 5 of 5