JDL SYSTEMS Submersible Sump / Sewage Pumps Table of Contents Project: Model: Chk d: Date:

Similar documents
DSZ3. EBARA Submersible Propeller Pumps Contents Project: Model: Chk d: Date: Model

Contents Project: Model: Chk d: Date:

EBARA Submersible Propeller Pumps Contents Project: Model: Chk d: Date: Model

CGUII/CGFU. Model CGUII/CGFU Contents. EBARA PRO Cast Grinder Pumps. Model 32CGUII61.5S

Series 8SHDU. Specifications: Series: 8SHDU 25-30HP, 1750RPM, 60Hz HP, 1150RPM, 60Hz. 21 Frame Driver 3.50" Spherical Solids Handling

Series 6XSHD. Specifications: Series: 6XSHD 15-30HP, 1750RPM, 60Hz HP, 1150RPM, 60Hz. 21 Frame Driver 3" Spherical Solids Handling

KW Submersible, Single-Vane Impeller

Series 4XSHM 18 Frame Driver 3" Spherical Solids Handling

Series 4XSHV. Specifications: Series: 4XSHV , 3450RPM, 60Hz 2-10HP, 1750RPM, 60Hz. 18 Frame Driver 3" Spherical Solids Handling

MYERS 4VCDP. 4" Solids Handling

Series 4XSHD. Specifications: Series: 4XSHD 3-10HP, 1750RPM, 60Hz. 18 Frame Driver 3" Spherical Solids Handling

Selection Chart Project: Model: Chk d: Date: C C V V V A CAPACITY

EBARA Submersible Pumps DLU, DVU, DGUII, DGFU, DLFU, DVFU, DDLFU Technical Information Project Model: Chk d: Date: Contents

Series 6SHV. Specifications: Series: 6SHV 15-30HP, 1750RPM, 60Hz HP, 1150RPM, 60Hz. 21 Frame Driver 3" Spherical Solids Handling

DSC3/DSCA3, DSZ3. EBARA Submersible Sewage and Propeller Pumps. Technical Data Contents Project: Model: Chk d: Date:

MYERS MODELS 4R AND 4RX

Series 6SHM. Specifications: Series: 6SHM 15-30HP, 1750RPM, 60Hz HP, 1150RPM, 60Hz. 21 Frame Driver 3" Spherical Solids Handling

MYERS 3MW VERTICAL DISCHARGE WASTEWATER PUMPS. Sewage, high-capacity sump, effluent

MYERS MODELS 4VC & 4VCX

MYERS MODELS 6VC & 6VCX

MYERS MODELS 4RC AND 4RCX

Series 4SHM. Specifications: Series: 4SHM 3-10HP, 1750RPM, 60Hz. 18 Frame Driver 3" Spherical Solids Handling. Solids Handling Submersible Pumps

Contents Project: Model: Chk d: Date:

Pump Specifications LE100-Series 1HP Submersible Sewage Pump

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

EFQT/EFQU. EBARA Self Priming Trash Pump. Contents Project: Model: Chk d: Date:

MYERS MODELS 4V AND 4VX

50 Hz Products. Commercial Duty Pumps Heavy Duty Solids Handling Pumps Grinder Pumps Lift Station Accessories. Trusted. Tested. Tough.

Pump Specifications. D3648LSG, D3648LSGX Series Omnivore 2HP Duplex Grinder Packages LITERS PER SECOND

Pump Specifications FL150 Series Submersible Effluent Pump

NOTE: LEH100-Series high-head pumps require a minimum application of 15' head. Do not use pump in this area use a smaller pump.

KG(X)3. Grinder Pumps. 3HP High Flow Grinder Pump (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve. Total Head (FT) Capacity (GPM)

Pump Specifications FL100 Series Submersible Effluent Pump

GR NDER PUMPS. Technical Catalog

Pump Specifications LE40 Series 4/10 HP Submersible Sewage Pump Pump

Pump Specifications. LE50 Series ½ HP Submersible Sewage Pump

SUBMERSIBLE GRINDER PUMPS: MOTORS: FLOWS to 135 USGPM HEADS to 350 FT TDH SEMI-OPEN, MULTI-VANE, IMPELLER DUPLEX STAINLESS STEEL GRINDING MECHANISM

XLE50 FLOW RATE (LPM) Flow Rate (GPM)

Technical Data 5430 M & W SUBMERSIBLE SOLIDS HANDLING PUMPS

GR NDER PUMPS. 505 Woodland Rd., Mt. Pocono, PA Phone: (570) Fax: (570)

LITERS PER MINUTE GALLONS PER MINUTE

CMLEU 80CMLEU622. EBARA Fluid Handling (803) (803) (fax) rev. 10/11

Pump Specifications 290 Series 3/4 hp Submersible Effluent Pump

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

Pump Specifications. ELV Series Submersible Sump Pump with OilTector Control. ELV250 1/3 hp ELV280 1/2 hp ELV290 3/4 hp

Series MSC Sewage Chopper Pumps

XFL70 FLOW RATE (LPM) Flow Rate (GPM)

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

SKHS SERIES 2 HP 1-1/2 HP 1 HP 1/2 HP CAPACITY-U.S. G.P.M.

Pump Specifications 250 Series Submersible Sump / Effluent Pump

Built For Work. THREE-PHASE PUMPS

Pump Specifications FL50 Series 1/2 hp Submersible Effluent Pump

MODEL 7ASX-8 SPECIFICATION

SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM

Pump Specifications 280 Series 1/2 hp Submersible Effluent Pump

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

SPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

CENTERLINE DISCHARGE. Technical Data 5730 MV 490 FRAME PULL-UP SUBMERSIBLE,

PUMP. Submersible Sewage Pumps Type DSC4 FEATURES/BENEFITS

Pump Specifications. Omnivore 2HP Submersible Grinder Pumps LSG200-SERIES (SINGLE STAGE) LSGX200-SERIES (TWO STAGE)

SPD50H/100H. Performance Data SPD100H SPD50H. Wholesale Products Page: Section: Performance Data Dated: April 2002 Supersedes: January 2001

SKV40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 2" Solids: 2" GPM: TDH:

SPECIFICATIONS OXYMAX SUB-SURFACE AERATION SYSTEM

SUBMERSIBLE SEMI-VORTEX SEWAGE PUMPS

390 Series Multi-Stage Vertical In-Line Centrifugal Pumps

HYDROMATIC SKHS SERIES SUBMERSIBLE NON-CLOG, SEWAGE EJECTOR

EBARA CORPORATION. Technical Document. DSC4 50Hz Version 45 SHEETS. DOC. No. ETP-0002 REV. 1. Submersible Pump Development Dept.

Pump Specifications FL60/FLH60 Series 6/10 hp Submersible Effluent Pump

AMPRO ELECTRIC LTD. Series 6SHV 21 Frame Driver 3" Spherical Solids Handling. Specifications: Series: 6SHV HP, 1750RPM, 1150RPM, 60Hz

4500C Series Vortex Pumps

P U M P. Pumps for Municipal and Commercial Operations

High Temperature Air-Cooled Hot Oil Pumps

Pump Specifications 405 Series Commercial Drain Pump (High-Temp)

SPECIFICATIONS EFFLUENT/SUMP SIMPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

WASTEWATER SUBMERSIBLE MOTOR PUMP MODEL DML3

Submersible Stainless Steel Semi-Vortex Pumps Pumps

Basic Hydraulic Features. Basic Mechanical Features

LITERS PER MINUTE TOTAL HEAD IN FEET TOTAL HEAD IN METERS GALLONS PER MINUTE

High Temperature Air-Cooled Hot Oil Pumps

HYDROMATIC SPD50H/100H SUBMERSIBLE HIGH HEAD, DOUBLE SEAL EFFLUENT

OIL SMART PLUG AND PLAY SYSTEM, Model #OSS-100

8VL and 8VLX. UÒ=pìÄãÉêëáÄäÉ=kçåJ`äçÖ=t~ëíÉï~íÉê=mìãé pí~åç~êç=eusif=~åç=bñéäçëáçåjmêççñ=eusiuf

HYDROMATIC SK75/100 SUBMERSIBLE SEWAGE EJECTOR

RSV Series In-Line Vertical Multi-Stage, Ring Section Pump September 2013

Series 3SHM. Specifications: Series: 3SHM 2-7.5HP, 1750RPM, 60Hz. 18 Frame Driver 2.5" Spherical Solids Handling. Solids Handling Submersible Pumps

SUGGESTED SPECIFICATIONS

Technical Data DML. Submersible Sewage Pumps with Single Channel Impeller. DML_Techdata_SS_V11 EBARA PUMPS AUSTRALIA PTY. LTD.

KGX2-21. Grinder Pumps. 2HP Dual Seal Grinder Pump, External Start (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve

855 Filtrate Pump, Close Coupled and Overhead Mounted Pumps

HYDROMATIC SPX50/SPX50H EXPLOSION PROOF, SEWAGE EJECTOR

our contribution for Sealless Magnetic Coupled Multistage Centrifugal Pumps Type HZM / HZMR / HZMB environmental protection

Sealless Magnetic Coupled Hot Oil Circulation Pumps acc. to DIN EN / ISO 2858 Type NMWR / NMWB / NMW. our. contribution for

SL B. Grundfos pump GRUNDFOS DATA BOOKLET

Commercial Sewage & Waste Water Systems

Series description: Wilo-Drain MTC

NC State University Design and Construction Guidelines Division 23 Hydronic Pumps

1SV (e-sv) 60 Hz 3500 RPM

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

our contribution for environmental protection Sealless magnetic coupled centrifugal pumps acc. to EN Type NML / NMB

Submersible Grinder Pumps Type ABS Piranha

Transcription:

Table of Contents Project: Model: Chk d: Date: Model JCSN 2JCSN2 (2 HP) 3JCSN2 (2 HP) 3JCSNY2 (2 HP) 3JCSN3 (3 HP) 3JCSNY3 (3 HP) 3JCSN ( HP) 3JCSNY ( HP) 3JCSN7 (7. HP) 3JCSNY7 (7. HP) 3JCSN1 (1 HP) 3JCSNY1 (1 HP) 3JCSN1 (1 HP) 3JCSNY1 (1 HP) 3JCSN2 (2 HP) 3JCSN2 (2 HP) 3JCSN3 (3 HP) 4JCSN2 (2 HP) 4JCSN3 (3 HP) 4JCSNY3 (3 HP) 4JCSN ( HP) 4JCSNY ( HP) 4JCSN7 (7. HP) 4JCSNY7 (7. HP) 4JCSN1 (1 HP) 4JCSNY1 (1 HP) 4JCSN1 (1 HP) 4JCSNY1 (1 HP) 4JCSN2 (2 HP) 4JCSNY2 (2 HP) 4JCSN2 (2 HP) 4JCSNY2 (2 HP) 4JCSN3 (3 HP) 4JCSNY3 (3 HP) 4JCSN4 (4 HP) 4JCSN ( HP) 4JCSN6 (6 HP) 6JCSN1 (1 HP) 6JCSN1 (1 HP) 6JCSN2 (2 HP) 6JCSN2 (2 HP) 6JCSN3 (3 HP) 6JCSN4 (3 HP) 6JCSN ( HP) 6JCSN6 (6 HP) 8JCSN1 (1 HP) 8JCSN1 (1 HP) 8JCSN2 (2 HP) 8JCSN2 (2 HP) 8JCSN3 (3 HP) 8JCSN4 (4 HP) 8JCSN ( HP) 8JCSN6 (6 HP) 1JCSN1 (1 HP) 1JCSN2 (2 HP) 1JCSNY2 (2 HP) 1JCSN2 (2 HP) 1JCSN3 (3 HP) 1JCSN4 (4 HP) 1JCSN ( HP) 1JCSN6 (6 HP) 12JCSN2 (2 HP) 12JCSN3 (3 HP) 12JCSN4 (4 HP) 12JCSN ( HP) 12JCSN6 (6 HP) Section Page Specifications H1-1 Selection Chart H1-8 H1-9 Outline Drawings H1-38 Sectional View H1-8 Pump Removal Systems K1- Technical Information TD1- material specification impeller description motor protection cable entry paint specifications mechanical seal general Motor Data MD1- motor electrical specifications cable data wiring diagrams motor electrical data www.jdlpumpsystems.us H1- (t) 888 668 934 (f) 888 668 9344 rev. 7/8

Specifications Project: Model: Chk d: Date: Model JCSN Specifications Standard Optional Size 2, 3, 4, 6, 8, 1, 12 inch Range of HP Range of Performance Limitation Maximum Water Temperature Synchronous Speed Materials Casing Impeller Motor Frame Fastener Mechanical Seal 2 to 6 HP Capacity 13 to 4 GPM Head 7 to 243 feet 14 F (4 C) 18 RPM Cast Iron Cast Iron (2 to 6HP) Ductile Iron (1-3 DLFU 4 to 6 HP) Shaft 43 Stainless Steel (2 to HP) 42 Stainless Steel (7 1 /2 to 6HP) Cast Iron 34 Stainless Steel Double Mechanical Seal Material Upper Side Carbon/Ceramic (2 to 6HP) Tungsten Carbide/Tungsten Carbide Material Lower Side Silicon Carbide/Silicon Carbide (2 to 6HP) Tungsten Carbide/Tungsten Carbide Tungsten Carbide/Tungsten Carbide (1-3 DLFU and 6HP only) Impeller Type Semi-open (2 to 3HP) Enclosed (4 to 6HP) Bearing Prelubricated Ball Bearing Motor Insulation Class F EBARA FM Explosion Proof, Three Phase 28/23/46V Class 1,Division 1, Group C, D Service Factor 1.1 Motor Protection Accessories Thermal Detector Klixons Mechanical Seal Leakage Detector Float Switch Submersible cable 33 ft. (2 to HP) 4 ft. (7 1 /2 to 6HP) ft. (customer specified) PRS System www.jdlpumpsystems.us H1-1 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

Specifications Project: Model: Chk d: Date: A. General: Provide submersible sewage pumps suitable for continuous duty operation underwater without loss of watertight integrity to a depth of 6 feet. Pump system design shall include a guide rail system be such that the pump will be automatically connected to the discharge piping when lowered into place on the discharge connection. The pump shall be easily removable for inspection or service, requiring no bolts, nuts, or other fasteners to be disconnected, or the need for personnel to enter the wet well. The motor and pump shall be designed, manufactured, and assembled by the same manufacturer. B. Manufacturer: J D L Systems, Inc. C. Pump Characteristics: Pumps shall conform to the following requirements: Number of units Design flow (gpm) Design TDH (ft) Minimum shut off head (ft) RPM 18 Maximum HP Minimum efficiency at design (%) Minimum power factor at design (%) Voltage/HZ 28/23V, 46V / 6 Phase 3 D. Pump Construction: All major parts of the pumping unit(s) including casing, impeller, suction cover, wear rings, motor frame and discharge elbow shall be manufactured from gray cast iron, ASTM A-48 Class 3. Castings shall have smooth surfaces devoid of blow holes or other casting irregularities. Casing design shall be centerline discharge with a large radius on the cut water to prevent clogging. Units shall be furnished with a discharge elbow and 12 lb. flat face ANSI flange. All exposed bolts and nuts shall be 34 stainless steel. All mating surfaces of major components shall be machined and fitted with NBR O-rings where watertight sealing is required. Machining and fitting shall be such that sealing is accomplished by automatic compression of O-rings in two planes and O-ring contact is made on four surfaces without the requirement of specific torque limits. Internal and external surfaces are prepared to SPPC-VISI-SP-3-63 then coated with a zinc-chromate primer. The external surfaces are then coated with a H.B. Tnemecol 46-46 Coal Tar paint. 1. Impellers: a. For units 2 to HP, the impeller shall be radial single or multi-vane, semi-open design. It shall be dynamically balanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the impeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might otherwise clog the pump. The 2 to HP impeller design shall also include back pump out vanes to reduce the pressure and entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be located behind the impeller hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct connected to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include a replaceable cast iron suction cover. The suction cover shall be designed such that it may be adjusted to maintain working clearances and hydraulic efficiencies. b. For units 7 1 /2 to 3 HP, the impeller shall be a mixed flow multi-vane semi-open design. It shall be dynamically balanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the impeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might otherwise clog the pump. The 7 1 /2 to 3 HP impeller design shall also include back pump out vanes to reduce the www.jdlpumpsystems.us H1-2 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

Specifications Project: Model: Chk d: Date: pressure and entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be located behind the impeller hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct connected to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include a replaceable cast iron suction cover. The suction cover shall be designed such that it may be adjusted to maintain working clearances and hydraulic efficiencies. c. For high head units with 4'' discharge, 4 to 6 HP shall have a radial multi-vane, enclosed impeller design. It shall be dynamically balanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the impeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might otherwise clog the pump. A lip seal shall be located behind the impeller hub to reduce the entry of foreign materials into the mechanical seal area. Impellers shall be direct connected to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include a replaceable casing wear ring at the pump suction to maintain working clearances and hydraulic efficiencies. d. For units 6'' to 12'' discharge sizes, 4 to 6 HP, the impeller shall be a mixed flow multi-vane enclosed design. It shall be dynamically balanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the impeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might otherwise clog the pump. A lip seal shall be located behind the impeller hub to reduce the entry of foreign materials into the seal area. Impellers shall be direct connected to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include a replaceable casing wear ring at the pump suction to maintain working clearances and hydraulic efficiencies. 2. Mechanical Seals a. For units 2 to HP, double mechanical seals operating in an oil bath shall be provided on all units. The oil filled seal chamber shall be designed to prevent over-filling and include an anti-vortexing vane to insure proper lubrication of both seal faces. Lower face materials shall be silicon carbide, upper faces carbon vs. ceramic, NBR elastomers, and 34SS hardware. Seal system shall not rely on pumping medium for lubrication. b. Units 7 1 /2 to 6 HP shall be designed to include a double mechanical seal in a tandem arrangement. Each seal shall be positively driven and act independently with its own spring system. The upper seal operates in an oil bath, while the lower seal is lubricated by the oil from between the shaft and the seal faces, and in contact with the pumpage. The oil filled seal chamber shall be designed to prevent over-filling and include an anti-vortexing vane to insure proper lubrication of both seal faces. Lower face materials shall be silicon carbide (tungsten carbide for 1-3 DLF & 6 HP only), upper faces carbon vs. ceramic, NBR elastomers, and 34SS hardware. Seal system shall not rely on pumping medium for lubrication. E. Motor Construction: The pump motor shall be an air filled induction type with a squirrel cage rotor, shell type design, built to NEMA MG-1, Design B specifications. Stator windings shall be copper, insulated with moisture resistant Class F insulation, rated for 311 F. The stator shall be dipped and baked three times in Class F varnish and heat shrunk fitted into the stator housing. Rotor bars and short circuit rings shall be manufactured of cast aluminum. Motor shaft shall be one piece AISI43 for 2 to HP, AISI42 for 7 1 /2 to 6 HP, rotating on two permanently lubricated ball bearings designed for a minimum B-1 life of 6, hours. Motor service factor shall be 1.1 and capable of up to 2 starts per hour. The motor shall be designed for continuous duty pumping at a maximum sump temperature of 14 F. Voltage and frequency tolerances shall be a maximum 1 / % respectively. Motor over temperature protection shall be provided by miniature thermal protectors embedded in the windings. Mechanical seal failure protection shall be provided by a mechanical float switch located in a chamber above the seal. This switch shall be comprised of a magnetic float that actuates a dry reed switch encapsulated within the stem. Should the mechanical seal fail, liquid shall be directed into the float chamber, in which the rising liquid activates the switch opening the normally closed circuit. For units 2 to 3 HP the float body and float shall be a polypropylene material with a 316SS stopper. Units 4 HP and greater, the float switch components shall be 34SS. The motor shall be non-overloading over the entire specified range of www.jdlpumpsystems.us H1-3 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

Specifications Project: Model: Chk d: Date: operation and be able to operate at full load intermittently while unsubmerged without damage to the unit. Power cable jacket shall be manufactured of an oil resistant chloroprene rubber material, designed for submerged applications. Cable shall be watertight to a depth of a least 6'. The cable entry system shall comprise of primary, secondary, and tertiary sealing methods. The primary seal shall be achieved by an cylindrical elastomeric grommet compressed between the motor cover and a 34SS washer. Secondary sealing is accomplished with a compressed O-ring made of NBR material. Compression and subsequent sealing shall preclude specific torque requirements. The system shall also include tertiary sealing to prevent leakage into the motor housing due to capillary action through the insulation if the cable is damaged or cut. The cable wires shall be cut, stripped, re-connected with a copper butt end connector, and embedded in epoxy within the cable gland. This provides a dead end for leakage through the cable insulation into the motor junction area. The cable entry system shall be the same for both the power and control cables. F. Pump Removal System (PRS): Model SRS, MRS, LRS Design shall include two (2) 34SS schedule 4 guide rails sized to mount directly to the pump removal system, base, at the floor of the wetwell and to a guide rail bracket at the top of the wetwell below the hatch opening, (refer to project drawings). Intermediate guide brackets are recommended for rail lengths over 1 feet. Guide rails are not part of the pump package and shall be supplied by others. The PRS shall be manufactured of cast iron, ASTM A48 Class 3. It shall be designed to adequately support the guide rails, discharge piping, and pumping unit under both static and dynamic loading conditions with support legs that are suitable for anchoring it to the wetwell floor. The face of the inlet PRS flange shall be perpendicular to the floor of the wetwell. The discharge flange of the PRS shall conform to ANSI B16.1 Class 12. The pump design shall include an integral self-aligning sliding bracket. Sealing of the pumping unit to the PRS shall be accomplished by a single, linear, downward motion of the pump. The entire weight of the pump unit shall be guided to and wedged tightly against the inlet flange of the PRS, making metal to metal contact with the pump discharge forming a seal without the use of bolts, gaskets or O-rings. Lifting chain shall be galvanized (stainless steel) suitable for removing and installing the pump unit. www.jdlpumpsystems.us H1-4 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

JDL Submersible Sump/Sewage Pumps Specifications JCSNE Explosion Proof Non-clog Project:Model: Chk d: Date: A. General: Provide FM explosion proof submersible non clog sewage pumps suitable for continuous duty operation underwater without loss of watertight integrity to a depth of 6 feet. Pump system design shall include a guide rail system be such that the pump will be automatically connected to the discharge piping when lowered into place on the discharge connection. The pump shall be easily removable for inspection or service, requiring no bolts, nuts, or other fasteners to be disconnected, or the need for personnel to enter the wet well. The motor and pump shall be designed, manufactured, and assembled by the same manufacturer. B. Manufacturer: J D L Systems, Inc. C. Pump Characteristics: Pumps shall conform to the following requirements: Number of units Design flow (gpm) Design TDH (ft) Minimum shut off head (ft) RPM 18 Maximum HP Minimum efficiency at design (%) Minimum power factor at design (%) Voltage/HZ 28/23V, 46V / 6 Phase 3 D. Pump Construction: All major parts of the pumping unit(s) including casing, impeller, suction cover, wear rings, motor frame and discharge elbow shall be manufactured from gray cast iron, ASTM A-48 Class 3. Castings shall have smooth surfaces devoid of blow holes or other casting irregularities. Casing design shall be centerline discharge with a large radius on the cut water to prevent clogging. Units shall be furnished with a discharge elbow and 12 lb. flat face ANSI flange. All exposed bolts and nuts shall be 34 stainless steel. All mating surfaces of major components shall be machined and fitted with NBR O-rings where watertight sealing is required. Machining and fitting shall be such that sealing is accomplished by automatic compression of O-rings in two planes and O-ring contact is made on four surfaces without the requirement of specific torque limits. Internal and external surfaces are prepared to SPPC-VISI-SP-3-63 then coated with a zinc-chromate primer. The external surfaces are then coated with a H.B. Tnemecol 46-46 Coal Tar paint. 1. Impellers: a. For units 2 to HP, the impeller shall be single or radial multi-vane, semi-open design. It shall be dynamically balanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the impeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might otherwise clog the pump. The 2 to HP impeller design shall also include back pump out vanes to reduce the pressure and entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be located behind the impeller hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct connected to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include a replaceable cast iron suction cover. The suction cover shall be designed such that it may be adjusted to maintain working clearances and hydraulic efficiencies. b. For units 7 1 /2 to 3 HP, the impeller shall be a mixed flow multi-vane semi-open design. It shall be dynamically balanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the impeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might otherwise clog the pump. The 7 1 /2 to 3 HP impeller design shall also include back pump out vanes to reduce the www.jdlpumpsystems.us H1- (t) 888 668 934 (f) 888 668 9344 rev. 7/8

JDL Submersible Sump/Sewage Pumps Specifications JCSNE Explosion Proof Non-clog Project: Model: Chk d: Date: pressure and entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be located behind the impeller hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct connected to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include a replaceable cast iron suction cover. The suction cover shall be designed such that it may be adjusted to maintain working clearances and hydraulic efficiencies. c. For high head units, 4'' discharge, 4 to 6 HP shall have a radial multi-vane, enclosed impeller design. It shall be dynamically balanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the impeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might otherwise clog the pump. A lip seal shall be located behind the impeller hub to reduce the entry of foreign materials into the mechanical seal area. Impellers shall be direct connected to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include a replaceable casing wear ring at the pump suction to maintain working clearances and hydraulic efficiencies. d. For units 6'' to 12'' discharge sizes, 4 to 6 HP, the impeller shall be a mixed flow multi-vane enclosed design. It shall be dynamically balanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the impeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might otherwise clog the pump. A lip seal shall be located behind the impeller hub to reduce the entry of foreign materials into the seal area. Impellers shall be direct connected to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include a replaceable casing wear ring at the pump suction to maintain working clearances and hydraulic efficiencies. 2. Mechanical Seals a. For units 2 to HP, double mechanical seals operating in an oil bath shall be provided on all units. The oil filled seal chamber shall be designed to prevent over-filling and include an anti-vortexing vane to insure proper lubrication of both seal faces. Lower face materials shall be silicon carbide, upper faces carbon vs. ceramic, NBR elastomers, and 34SS hardware. Seal system shall not rely on pumping medium for lubrication. b. Units 7 1 /2 to 6 HP shall be designed to include a double mechanical seal in a tandem arrangement. Each seal shall be positively driven and act independently with it s own spring system. The upper seal operates in an oil bath, while the lower seal is lubricated by the oil from between the shaft and the seal faces, and in contact with the pumpage. The oil filled seal chamber shall be designed to prevent over-filling and include an anti-vortexing vane to insure proper lubrication of both seal faces. Lower face materials shall be silicon carbide, upper faces carbon vs. ceramic, NBR elastomers, and 34SS hardware. Seal systems shall not rely on pumping medium for lubrication. E. Motor Construction: The pump motor shall be FM Explosion Proof, Class 1, Division 1, Groups C, D. The design shall be an air filled induction type with a squirrel cage rotor, shell type design, built to NEMA MG-1, Design B specifications. Stator windings shall be copper, insulated with moisture resistant Class F insulation, rated for 311 F. The stator shall be dipped and baked three times in Class F varnish and heat shrunk fitted into the stator housing. Rotor bars and short circuit rings shall be manufactured of cast aluminum. Motor shaft shall be one piece AISI43 material for 2 to HP, AISI42 for 7 1 /2 to 6 HP material, rotating on two permanently lubricated ball bearings designed for a minimum B-1 life of 6, hours. Motor service factor shall be 1.1 and capable of up to 2 starts per hour. The motor shall be designed for continuous duty pumping at a maximum sump temperature of 14 F. Voltage and frequency tolerances shall be a maximum 1 / % respectively. Motor over temperature protection shall be provided by miniature thermal protectors embedded in the windings. Mechanical seal failure protection shall be provided by a mechanical float switch located in a chamber above the seal. This switch shall be comprised of a magnetic float that actuates a dry reed switch encapsulated within the stem. Should the mechanical seal fail, liquid shall be directed into the float chamber, in which the rising liquid activates the switch opening the normally closed circuit. For units 2 to 1 HP the float body and float shall be a polypropylene material with a 316SS stopper. Units 1 HP and greater, the float switch www.jdlpumpsystems.us H1-6 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

JDL Submersible Sump/Sewage Pumps Specifications JCSNE Explosion Proof Non-clog Project: Model: Chk d: Date: components shall be 34SS. The motor shall be non overloading over the entire specified range of operation and be able to operate at full load intermittently while unsubmerged without damage to the unit. Power cable jacket shall be manufactured of an oil resistant chloroprene rubber material, designed for submerged applications. Cable shall be watertight to a depth of a least 6'. The cable entry system shall comprise of primary, secondary, and tertiary sealing methods. The primary seal shall be achieved by an cylindrical elastomeric grommet compressed between the motor cover and a 34SS washer. Secondary sealing is accomplished with a compressed O-ring made of NBR material. Compression and subsequent sealing shall preclude specific torque requirements. The system shall also include tertiary sealing to prevent leakage into the motor housing due to capillary action through the insulation if the cable is damaged or cut. The cable wires shall be cut, stripped, re-connected with a copper butt end connector, and embedded in epoxy within the cable gland. This provides a dead end for leakage through the cable insulation into the motor junction area. The cable entry system shall be the same for both the power and control cables. F. Pump Removal System (PRS): Model SRS, MRS, LRS Design shall include two (2) 34SS schedule 4 guide rails sized to mount directly to the pump removal system base, at the floor of the wetwell and to a guide rail bracket at the top of the wetwell below the hatch opening, (refer to project drawings). Intermediate guide brackets are recommended for rail lengths over 1 feet. Guide rails are not part of the pump package and shall be supplied by others. The PRS shall be manufactured of cast iron, ASTM A48 Class 3. It shall be designed to adequately support the guide rails, discharge piping, and pumping unit under both static and dynamic loading conditions with support legs that are suitable for anchoring it to the wetwell floor. The face of the inlet PRS flange shall be perpendicular to the floor of the wetwell. The discharge flange of the PRS shall conform to ANSI B16.1 Class 12. The pump design shall include an integral self-aligning sliding bracket. Sealing of the pumping unit to the PRS shall be accomplished by a single, linear, downward motion of the pump. The entire weight of the pump unit shall be guided to and wedged tightly against the inlet flange of the PRS, making metal to metal contact with the pump discharge forming a seal without the use of bolts, gaskets or O-rings. Lifting chain or cable shall be stainless steel suitable for removing and installing the pump unit. www.jdlpumpsystems.us H1-7 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

Selection Chart Project: Model Model: Chk d: Date: Three Phase 6Hz TOTAL HEAD m ft 3 8 6 2 1 4 3 1 8 2 1 1 8 6 4 3 6 4 3 2 1 1 1 1 7 6 4 3 2 2 / 26 23 / 24 21 / 22 19 / 2 17 / 18 1 / 16 13 / 14 9 / 1 11 / 12 8 6Hz (Synchronous Speed 18 RPM) 1 2 3 4 6 8 1 1 2 3 4 6 81 1 2 3 4 USGPM.1.2.3.4..6.8 1. 1. 2. 3. 4.. 6. 8. 1 1 m 3 /min CAPACITY Please note: Overlap in coverage is designated by the two numbers; for example "9 / 1". Refer to the legend below for the specific model numbers. 27 3 31 32 28 29 4 39 48 37 38 47 36 46 3 44 4 34 43 3 33 41 42 49 2 1 4 8 7 9 6 61 6 64 63 62 6 66 1 2JCSN2 2HP 19 3JCSN1 1HP 37 4JCSN3 3HP 1JCSN2 2HP 2 3JCSNY2 2HP 2 4JCSNY1 1HP 38 6CSN4 4HP 6 1JCSNY2 2HP 3 3JCSNY3 3HP 21 3JCSN2 2HP 39 6JCSN HP 7 1JCSN2 2HP 4 3JCSNY HP 22 4JCSNY2 2HP 4 6JCSN6 6HP 8 1JCSN3 3HP 3JCSNY7 7½HP 23 3JCSN2 2HP 41 6JCSN1 1HP 9 1JCSN4 4HP 6 3JCSNY1 1HP 24 4JCSNY2 2HP 42 6JCSN1 1HP 6 1JCSN HP 7 3JCSNY1 1HP 2 3JCSN3 3HP 43 6CSN2 2HP 61 1JCSN6 6HP 8 4JCSN2 2HP 26 4JCSNY3 3HP 44 6JCSN2 2HP 62 12JCSN2 2HP 9 3JCSN2 2HP 27 4JCSN4 4HP 4 6JCSN3 3HP 63 12JCSN3 3HP 1 4JCSNY2 2HP 28 4JCSN HP 46 8JCSN4 4HP 64 12JCSN4 4HP 11 3JCSN3 3HP 29 4JCSN6 6HP 47 8JCSN HP 6 12JCSN HP 12 4JCSNY3 3HP 3 4JCSN3 3HP 48 8JCSN6 6HP 66 12JCSN6 6HP 13 3JCSN HP 31 4JCSN HP 49 8JCSN1 1HP 14 4JCSNY HP 32 4JCSN7 7½HP 8JCSN1 1HP 1 3JCSN7 7½HP 33 4JCSN1 1HP 1 8JCSN2 2HP 16 4JCSNY7 7½HP 34 4JCSN1 1HP 2 8JCSN2 2HP 17 3JCSN1 1HP 3 4JCSN2 2HP 3 8JCSN3 3HP 18 4JCSNY1 1HP 36 4JCSN2 2HP 4 1JCSN1 1HP www.jdlpumpsystems.us H1-8 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

2JCSN2 (2HP) Synchronous Speed: 18 RPM 2, 3 inch Discharge 6 Max.Dia. 182mm Curve No: JCSN63-923 Solid Dia 1 1/2" SRS23 4 6 4 3 3 2 1 2 1 2 1 2 4 6 8 1 12 14 Brake Horsepower () 3JCSN2 (2HP) Synchronous Speed: 18 RPM 1 9 Curve No: JSCN64-923 Solid Dia: 2 1/2" SRS34 6.. 8 7 6 4 3 2 1. 4 4. Max. Dia. 17mm - No Trim 4. 3 3. 3. 2. 2 2. 1. 1 1... 2 4 6 8 1 12 14 16 18 2 22 24 26 Brake Horsepower () www.jdlpumpsystems.us H1-9 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

JDL Submersible Sump/Sewage Pumps Project: GPM: TDH: EFF: HP: Date: 3JCSNY2 (2HP) Synchronous Speed: 18 RPM 4 Max. Dia. 17mm-No Trim Curve No: JCN-C61-923 SRS34 6 3 4 2 3 2 1 1 2 1 2 4 6 8 1 12 14 16 18 2 22 24 26 Brake Horsepower () 3JCSN3 (3HP) Synchronous Speed: 18 RPM 4 Max. Dia. 16mm Curve No: JCN-C6-923 Solid Dia 2 1/2" SRS43 3 7 6 2 Dia. 14mm 4 3 2 1 1 3 2 1 4 8 12 16 2 24 28 32 36 4 Brake Horsepower () www.jdlpumpsystems.us H1-1 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

3JCSNY3 (3HP) Synchronous Speed: 18 RPM 6 Max. Dia. 188mm - No Trim Curve No: JCSN62-923 SRS34 4 3 4 3 2 1 2 1 3 2 1 2 4 6 8 1 12 14 16 18 2 22 24 26 Brake Horsepower () 3JCSN (HP) Synchronous Speed: 18 RPM 6 Max. Dia. 189mm Curve No: JCSN67-923 MRS43 (%) 7 6 4 3 Min. Dia. 171mm 4 3 2 1 2 1 1 2 3 4 6 Brake Horsepower () www.jdlpumpsystems.us H1-11 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

3JCSNY (HP) Synchronous Speed: 18 RPM 7 6 Max. Dia. 28mm Curve No: JCSN63-923 SRS34 7 4 Min. Dia. 188mm 6 4 3 2 1 3 2 1 Brake Horsepower () 4 8 12 16 2 24 28 32 3JCSN7 (7 1 /2HP) Synchronous Speed: 18 RPM 6 7 6 Max. Dia. 27mm Curve No: JCSN68-923 MRS43 (%) 4 3 4 3 Min. Dia. 186mm 2 1 2 8 6 1 4 2 1 2 3 4 6 Brake Horsepower () www.jdlpumpsystems.us H1-12 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

3JCSNY7 (7 1 /2HP) Synchronous Speed: 18 RPM 9 8 Max. Dia. 22mm Curve No: JCSNY64-923 Solid Dia: 3" SRS34 7 6 4 6 4 Min. Dia. 23mm 3 2 1 3 2 8 6 1 4 2 1 1 2 2 3 3 4 Brake Horsepower () 3JCSN1 (1HP) Synchronous Speed: 18 RPM 8 7 7 Max. Dia. 14.9/238mm Curve No: JCSN69-923 MRS43 6 6 (%) 4 4 Min. Dia. 122.9/22mm 3 2 1 3 2 1 1 1 2 3 4 6 7 8 Brake Horsepower () www.jdlpumpsystems.us H1-13 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

3JCSNY1 (1HP) Synchronous Speed: 18 RPM 1 9 1 9 Max. Dia. 187./29mm T.D.H. Curve No: JCSNY6-923 Solid Dia: 3" MRS34 4 8 8 Min. Dia. 16./237mm T.D.H. 4 7 7 3 6 4 3 2 1 6 4 3 2 1 3 2 2 1 1 Brake Horsepower () 1 2 3 4 6 3JCSN1 (1HP) Synchronous Speed: 18 RPM 1 9 9 8 Max. Dia. 172.4/263mm Curve No: JCSN61-923 MRS43 8 7 Efficiency(%) 7 6 4 3 2 1 6 4 3 2 1 Min. Dia. 11.4/242mm 1 1 1 2 3 4 6 7 8 Brake Horsepower () www.jdlpumpsystems.us H1-14 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

3JCSNY1 (1HP) Synchronous Speed: 18 RPM 1 12 9 8 7 6 4 11 1 9 8 7 6 Min. Dia. 191/27mm Max. Dia. 21/281mm Curve No: JCSNY66-923 MRS34 3 2 1 4 3 2 1 1 2 3 4 6 1 1 Brake Horsepower () 3JCSN2 (2HP) Synchronous Speed: 18 RPM 12 11 1 9 Max. Dia. 196.4/287mm Curve No: JCSN611-923 MRS43 8 Min. Dia. 172.4/263mm 7 6 7 6 4 3 2 1 4 3 2 1 2 1 1 1 2 3 4 6 7 8 Brake Horsepower () www.jdlpumpsystems.us H1-1 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

4JCSN2 (2HP) Synchronous Speed: 18 RPM 3 Max. Dia. 138mm Curve No: JCSN613-923 MRS34 6 2 4 3 2 1 1 Min. Dia. 12mm 3 2 1 Brake Horsepower () 1 1 2 2 3 3 4JCSN3 (3HP) Synchronous Speed: 18 RPM 4 Max. Dia. 16mm Curve No: JCSN614-923 MRS34 3 6 4 3 2 1 2 1 Min. Dia. 14mm 3 2 1 1 2 3 4 Brake Horsepower () www.jdlpumpsystems.us H1-17 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

4JCSNY3 (3HP) Synchronous Speed: 18 RPM 4 Max. Dia. 16mm Curve No: JCSNY6-923 Solid Dia 2 1/2" MRS43 3 7 6 2 Min. Dia. 14mm 4 3 2 1 1 3 2 1 4 8 12 16 2 24 28 32 36 4 Brake Horsepower () 4JCSN (HP) Synchronous Speed: 18 RPM Curve No:JCSN61-923 MRS34 4 Max. Dia. 172mm 6 4 3 2 1 3 2 1 Min. Dia. 16mm 4 3 2 1 1 1 2 2 3 3 4 4 6 Brake Horsepower () www.jdlpumpsystems.us H1-18 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

4JCSNY (HP) Synchronous Speed: 18 RPM 6 Max. Dia. 189mm Curve No: JCSNY67-923 MRS43 4 7 6 3 Min. Dia. 171mm 4 3 2 1 2 1 1 2 3 4 6 Brake Horsepower () 4JCSN7 (7 1 /2HP) Synchronous Speed: 18 RPM 4, 6 inch Discharge 1 9 8 4 4 3 Max. Dia. 1.8/22mm Curve No: JCSN-C614-923 LRS46 7 6 4 3 2 1 3 2 Min. Dia. 89.8/24mm 2 1 1 1 2 3 4 6 7 8 9 1 1 Brake Horsepower () www.jdlpumpsystems.us H1-19 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

4JCSNY7 (7 1 /2HP) Synchronous Speed: 18 RPM 6 7 6 Max. Dia. 27mm Curve No: JCSNY68-923 MRS43 4 3 4 3 Min. Dia. 186mm 2 1 2 8 6 1 4 2 1 2 3 4 6 Brake Horsepower () 4JCSN1 (1HP) Synchronous Speed: 18 RPM 4, 6 inch Discharge 1 6 Max. Dia. 12.8/23mm Curve No: JCSN61-923 LRS46 9 8 4 7 6 3 Min. Dia. 13.8/218mm 4 3 2 1 2 1 1 1 2 3 4 6 7 8 9 1 11 Brake Horsepower () www.jdlpumpsystems.us H1-2 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

4JCSNY1 (1HP) Synchronous Speed: 18 RPM 1 9 8 Max. Dia. 14.9/238mm. Curve No: JCSNY69-923 Solid Dia. 3" MRS43 9 8 8 7 7 7 6 4 3 2 1 6 4 3 2 1 Min. Dia. 122.9/22mm 6 4 3 2 1 Brake Horsepower () 1 2 3 4 6 7 8 4JCSN1 (1HP) Synchronous Speed: 18 RPM 4, 6 inch Discharge 9 8 Max. Dia. 139.7/24mm Curve No: JCSN616-923 LRS46 7 7 6 4 6 4 Min. Dia. 12.7/23mm 3 2 1 3 2 1 1 2 3 4 6 7 8 9 1 11 1 1 Brake Horsepower () www.jdlpumpsystems.us H1-21 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

4JCSNY1 (1HP) Synchronous Speed: 18 RPM 1 9 9 8 Max. Dia. 172.4/263mm Curve No: JCSNY61-923 MRS43 9 8 8 7 Min. Dia. 11.4/242mm 7 7 6 6 6 4 3 2 1 4 3 2 1 4 3 2 1 Brake Horsepower () 1 2 3 4 6 7 8 4JCSN2 (2HP) Synchronous Speed: 18 RPM 4, 6 inch Discharge 11 1 Max. Dia. 173.1/278mm Curve No: JCSN617-923 LRS46 9 8 7 6 7 6 Min. Dia. 11.1/26mm 4 3 2 1 4 3 2 1 2 1 1 2 4 6 8 1 12 Brake Horsepower () www.jdlpumpsystems.us H1-22 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

4JCSNY2 (2HP) Synchronous Speed: 18 RPM 12 11 1 9 Max. Dia. 196.4/287mm Curve No: JCSNY611-923 MRS43 8 Min. Dia. 172.4/263mm 7 6 7 6 4 3 2 1 4 3 2 1 2 1 1 1 2 3 4 6 7 8 Brake Horsepower () 4JCSNY2 (2HP) Synchronous Speed: 18 RPM 14 12 Max. Dia. 22/37mm Curve No: JCSNY612-923 MRS43 7 6 4 3 2 1 1 Min. Dia. 199/281mm 8 6 4 2 1 2 3 4 6 7 8 2 2 1 1 Brake Horsepower () www.jdlpumpsystems.us H1-23 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

4JCSN2 (2HP) Synchronous Speed: 18 RPM 4, 6 inch Discharge 12 11 Max. Dia. 192/288mm Curve No: JCSN618-923 LRS46 1 1 9 9 8 7 6 4 3 2 1 8 7 6 4 3 2 1 Min. Dia. 168/264mm 1 2 3 4 6 7 8 9 1 11 12 2 2 1 1 Brake Horsepower () 4JCSNY3 (3HP) Synchronous Speed: 18 RPM 16 14 Max. Dia. 238/32mm Curve No: JCSNY613-923 MRS43 12 7 6 4 3 2 1 1 Min. Dia. 211/293mm 8 6 4 3 2 2 1 1 2 3 4 6 7 8 Brake Horsepower () www.jdlpumpsystems.us H1-24 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

4JCSN3 (3HP) Synchronous Speed: 18 RPM 4, 6 inch Discharge 14 12 Max. Dia. 28/34mm Curve No: JCSN619-923 LRS46 1 1 9 8 7 6 8 6 Min. Dia. 183/279mm 4 3 2 1 4 2 1 2 3 4 6 7 8 9 1 11 12 3 2 1 Brake Horsepower () 4JCSN4 to 6 (4-6HP) Synchronous Speed: 18 RPM 26 24 22 D = 36mm D = 34mm D = 33mm 6 6 Curve No: JCSN61-968 MRS43 2 18 16 14 D = 31mm D = 3mm 68 7 7 12 4 HP 1 6 HP 8 HP 6 4 2 4 6 8 1 12 14 16 18 www.jdlpumpsystems.us H1-2 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

6JCSN1 8JCSN1 (1HP) Synchronous Speed: 18 RPM 6, 8 inch Discharge 6 Max. Dia. 124.6/22mm Curve No: JCSN622-923 LRS68 7 6 4 4 3 Min. Dia. 17.6/28mm 3 2 1 2 1 2 4 6 8 1 12 14 1 Brake Horsepower () 6JCSN1 8JCSN1 (1HP) Synchronous Speed: 18 RPM 6, 8 inch Discharge 7 8 7 Max. Dia. 143.6/244mm Curve No: JCSN623-923 LRS68 6 6 4 3 2 1 4 Min. Dia. 12.6/226mm 3 2 1 2 4 6 8 1 12 14 16 1 1 Brake Horsepower () www.jdlpumpsystems.us H1-26 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

6JCSN2 8JCSN2 (2HP) Synchronous Speed: 18 RPM 6, 8 inch Discharge 1 9 Max. Dia. 18/268mm Curve No: JCSN624-923 LRS68 8 7 7 6 4 6 4 Min. Dia. 12/24mm 3 2 1 3 2 2 1 1 2 4 6 8 1 12 14 16 Brake Horsepower () 6JCSN2 8JCSN2 (2HP) Synchronous Speed: 18 RPM 6, 8 inch Discharge 11 1 Max. Dia. 186/274mm Curve No: JCSN62-923 LRS68 9 8 7 6 7 6 Min. Dia. 163/21mm 4 3 2 1 4 3 2 1 2 4 6 8 1 12 14 16 2 2 1 1 Brake Horsepower () www.jdlpumpsystems.us H1-27 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

6JCSN3 8JCSN3 (3HP) Synchronous Speed: 18 RPM 6,8 inch Discharge 11 1 Curve No: JCSN626-923 LRS68 9 Max. Dia. 192/296mm 8 7 6 7 6 Min. Dia. 168/272mm 4 3 2 1 4 3 2 1 2 4 6 8 1 12 14 16 3 2 1 Brake Horsepower () 6JCSN4 (4HP) Synchronous Speed: 18 RPM 6 inch Discharge 14 12 Max. Dia. 213/319mm Curve No: JCSN61-923 LRS6Y 1 8 7 6 8 6 Min. Dia. 186/292mm 4 3 2 1 4 2 2 4 6 8 1 12 14 16 18 2 4 3 2 1 Brake Horsepower () www.jdlpumpsystems.us H1-28 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

6JCSN (HP) Synchronous Speed: 18 RPM 6 inch Discharge 16 14 Max. Dia. 226/324mm Curve No: JCSNC62-923 LRS6Y 12 7 6 4 3 2 1 1 Min. Dia. 199/297mm 8 6 4 2 2 4 6 8 1 12 14 16 18 2 4 3 2 1 Brake Horsepower () 6JCSN6 (6HP) Synchronous Speed: 18 RPM 6 inch Discharge 2 18 Max. Dia. 2/33mm Curve No:JCSN63-923 LRS6Y 8 7 16 14 6 12 1 Min. Dia. 22/323mm 4 8 3 2 1 6 4 2 2 4 6 8 1 12 14 16 18 6 4 3 2 Brake Horsepower () www.jdlpumpsystems.us H1-29 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

8JCSN4 (4HP) Synchronous Speed: 18 RPM 8 inch Discharge 12 11 1 9 Max. Dia. 22/37mm Curve No: JCSN64-923 LRS8Y 7 6 8 7 6 Min. Dia. 194/281mm 4 3 2 1 4 3 2 1 2 4 6 8 1 12 14 16 18 2 22 4 3 2 1 Brake Horsepower () 8JCSN (HP) Synchronous Speed: 18 RPM 8 inch Discharge 16 14 Max. Dia. 246/333mm Curve No: JCSN6-923 LRS8Y 12 7 6 4 3 2 1 1 Min. Dia. 217/34mm 8 6 4 2 2 4 6 8 1 12 14 16 18 2 22 4 3 2 1 Brake Horsepower () www.jdlpumpsystems.us H1-3 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

8JCSN6 (6HP) Synchronous Speed: 18 RPM 8 inch Discharge 18 16 Max. Dia. 263/3mm Curve No: JCSN66-923 LRS8Y 8 14 7 6 12 1 Min. Dia. 232/319mm 4 3 2 8 6 4 2 2 4 6 8 1 12 14 16 18 2 22 24 6 4 3 2 Brake Horsepower () 1JCSN1 (1HP) Synchronous Speed: 18 RPM 1 inch Discharge 1 9 8 6 Max. Dia. 147.1/247mm Curve No: JCSN627-923 Solid Dia 3 1/4" LRS1 (%) 7 6 4 4 3 Min. Dia. 13.1/23mm 3 2 1 2 1 2 4 6 8 1 12 14 16 18 2 1 1 Brake Horsepower () www.jdlpumpsystems.us H1-31 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

1JCSN2 (2HP) Synchronous Speed: 18 RPM 7 6 Curve No: JCSN628-923 Solid Dia 3 1/4" LRS1 1 inch Discharge Max. Dia. 18.1/28mm (%) 7 6 4 3 Min. Dia. 138.1/238mm 4 3 2 1 2 1 2 4 6 8 1 12 14 16 18 2 22 2 1 Brake Horsepower () 1JCSNY2 (2HP) Synchronous Speed: 18 RPM 8 7 Curve No: JCSNY629-923 Solid Dia 3 1/4" LRS1 1 inch Discharge 6 Max. Dia. 168/262mm (%) 7 4 Min. Dia. 148/242mm 6 4 3 2 1 3 2 1 2 4 6 8 1 12 14 16 18 2 22 2 2 1 1 Brake Horsepower () www.jdlpumpsystems.us H1-32 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

1JCSN2 (2HP) Synchronous Speed: 18 RPM 1 inch Discharge 9 8 Max. Dia. 179/273mm Curve No: JCSN63-923 Solid Dia 3 1/4" LRS1 7 7 (%) 6 4 6 4 Min. Dia. 17/21mm 3 2 1 3 2 2 2 1 1 1 4 8 12 16 2 24 Brake Horsepower () 1JCSN3 (3HP) Synchronous Speed: 18 RPM 1 inch Discharge 1 9 Max. Dia. 193/287mm Curve No: JCSN631-923 Solid Dia 3 1/4" LRS1 8 7 8 7 (%) 6 4 6 4 Min. Dia. 169/263mm 3 2 1 3 3 2 2 1 1 4 8 12 16 2 24 Brake Horsepower () www.jdlpumpsystems.us H1-33 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

1JCSN4 (4HP) Synchronous Speed: 18 RPM 1 inch Discharge 1 9 Max. Dia. 29/299mm Curve No:JCSN67-923 LRS1Y (%) 8 7 6 4 3 2 1 8 7 6 Min. Dia. 184/274mm 4 3 2 4 3 1 2 1 3 6 9 12 1 18 21 24 27 3 Brake Horsepower () 1JCSN (HP) Synchronous Speed: 18 RPM 1 inch Discharge 14 12 Max. Dia. 231/321mm Curve No: JCSN68-923 LRS1Y 1 (%) 7 6 4 3 2 1 Min. Dia. 23/293mm 8 6 4 2 1 1 2 2 3 4 3 2 1 Brake Horsepower () www.jdlpumpsystems.us H1-34 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

1JCSN6 (6HP) Synchronous Speed: 18 RPM 1 inch Discharge 14 12 Max. Dia. 248/338mm Curve No: JCSN69-923 LRS1Y 1 (%) 8 7 6 8 6 Min. Dia. 219/39mm 4 3 2 1 4 6 2 4 2 1 1 2 2 3 3 Brake Horsepower () 12JCSN2 (2HP) Synchronous Speed: 18 RPM 12 inch Discharge 4 Max. Dia. 137.1/237mm Curve No: JCSN632-923 Solid Dia 3 1/2" LRS12 (%) 6 4 3 2 Min. Dia. 12.1/22mm 3 2 1 1 2 2 1 1 1 2 3 Brake Horsepower () www.jdlpumpsystems.us H1-3 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

12JCSN3 (3HP) Synchronous Speed: 18 RPM 12 inch Discharge 4 Max. Dia. 11.1/21mm Curve No: JCSN633-923 Solid Dia 3 1/2" LRS12 6 3 Min. Dia. 131.1/231mm 4 3 2 1 2 1 3 2 Brake Horsepower () 1 1 2 3 12JCSN4 (4HP) Synchronous Speed: 18 RPM 12 inch Discharge 6 Max. Dia. 1.6/274mm Curve No:JCSN61-923 LRS12Y 4 7 6 3 Min. Dia. 134.6/23mm 4 3 2 1 2 1 4 3 2 1 Brake Horsepower () 1 2 3 4 www.jdlpumpsystems.us H1-36 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

12JCSN (HP) Synchronous Speed: 18 RPM 12 inch Discharge 8 7 Max. Dia. 174/278mm Curve No: JCSNC611-923 LRS12Y 6 (%) 8 7 4 Min. Dia. 11/2mm 6 4 3 2 1 3 2 4 1 3 2 1 6 12 18 24 3 36 42 Brake Horsepower () 12JCSN6 (6HP) Synchronous Speed: 18 RPM 12 inch Discharge 1 9 Max. Dia. 191/29mm Curve No: JCSN612-923 LRS12Y 8 7 8 7 (%) 6 4 6 4 Min. Dia. 167/271mm 3 2 1 3 2 6 1 4 3 2 1 2 3 4 Brake Horsepower () www.jdlpumpsystems.us H1-37 (t) 888 668 934 (f) 888 668 9344 rev. 7/8

3JCSN2 (2HP) Synchronous Speed: 18 RPM 14 12 Max. Dia. 22/37mm Curve No: JCSN612-923 MRS43 7 6 4 3 2 1 1 Min. Dia. 199/281mm 8 6 2 4 2 1 2 1 1 2 3 4 6 7 8 Brake Horsepower () 3JCSN3 (3HP) Synchronous Speed: 18 RPM 16 14 Max. Dia. 238/32mm Curve No: JCSN613-923 MRS43 12 7 6 4 3 2 1 1 Min. Dia. 211/293mm 8 6 4 3 2 2 1 1 2 3 4 6 7 8 Brake Horsepower () www.jdlpumpsystems.us H1-16 (t) 888 668 934 (f) 888 668 9344 rev. 7/8