Couper. Motori gear for swing gates MADE IN ITALY INSTRUCTION MANUAL

Similar documents
Jet. Gear motor for swing gates MADE IN ITALY INSTRUCTION MANUAL

INSTALLATION MANUAL ENGLISH ALPHA 200 ALPHA 330. L C (stroke) 960 mm 1160 mm

Dynamos GEAR-MOTOR FOR SLIDING GATES INSTRUCTION MANUAL

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS

INSTALLATION MANUAL ACE. Gearmotor for swing gates 01_17

ALPHA 200 PLUS ALPHA 330 PLUS INSTALLATION MANUAL

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

Wingo4024 Swing gate opener. EN - Instructions and warnings for installation and use

ARACHNE 230V 24V- 12V

SUBWING 700 USER S AND INSTALLER S MANUAL V1.0 REV. 04/2017

Ditec LUXO Swing gates automation (Original instruction)

E R A I GATE AUTOMATION DIVISION

HYDRAULIC OPERATOR FOR SWING GATE FULL TANK. SEA S.r.l. Zona Ind. S.Atto TERAMO Italy Tel Fax

BL240 BL240 - (15400) Operatore elettromeccanico lineare ISTRUZIONI PER L INSTALLAZIONE

ASW-400. Installation Manual. Downee

TURBO 40 TURBO 80 TURBO 120 TURBO 160

Electromechanical gear motor for sliding gates ACHILLES

kinggates collection

Ditec PWR25H/35H Automation for hinged gates

Owner s Manual. For SOLAR BOOM GATE. Model: CA-5000 SOLAR

Book INSTRUCTION MANUAL MADE IN ITALY

Model Specifications Code Price FOTOSWITCH

BULL 424 ESA BULL 624 ESA

V200 USER MANUAL SWING GATE OPENER. 100kg 1.5m. 100kg 1.5m

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

SWING GATE OPENERS 24V DC GEAR MOTOR

INSTALLATION MANUAL (cod )

Ditec PWR50H/HV/HR Automation for swing gates

with leaves up to 2 m Kg

BULL 5M - BULL 5M.S BULL 8M - BULL 8 M.S BULL 8 OM - BULL 8 OM.S

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

Automations for garage doors and rolling shutters

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR

Ditec CUBIC Swing gates automation

FEATURES AND SPECIFICATIONS

GROUND GROUND - ( ) Interrati elettromeccanici ISTRUZIONI PER L INSTALLAZIONE. Electromechanical underground INSTRUCTIONS FOR INSTALLATIONS

F ERNI K I T THE FERNI-S KIT CONSISTS OF:

IN-GROUND OPERATOR FOR SWING GATES FROG SERIES INSTALLATION MANUAL FROG-A 230V

BH30 SERIES Today s digital intelligence moves your gate

Istruzioni, instructions. Motoriduttore a braccio snodato per cancelli battenti Gear motor with articulated arm for swing gates ALPHEO

L /2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

MhouseKit GD0 For the automation of a sectional or overhead door.

Trouble Shooting a Jouan C/CR4.22 Centrifuge

DESIGNED FOR RESIDENTIAL APPLICATION KIT PL600/PL1000 SLIDING GATE OPENERS

KUSTOS ULTRA BT KIT A40 FRA

dynamos Automation for sliding gates up to 1000 Kg

Complete range of electromechanical pistons for residential use, suitable for swing gate leaves up to 4 metres wide and weighing up to 500 kg.

SWING GATE OPENERS 24V DC GEAR MOTOR

S1 Sequential. T56 Magnum. Sequential shifter. Contents and assembly instructions

FITTING AND CONNECTION INSTRUCTIONS

Ditec CROSS18-19 Sliding gates automation. IP1984 EN Technical Manual. (original instructions)

MOUNTING AND CONNECTING INSTRUCTIONS 1. GATE ARRANGEMENT ENGLISH

L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR

Ø5/16" HOLES FOR FASTENING TO CURB

Installing the gate post bracket with the cardboard arm template

VELA INDUSTRIAL INSTALLATION MANUAL

INSTRUCTIONS FOR INSTALLATION

L /2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

FROG KIT. Installation Instructions for a Pair of gates... TECHNICAL HELPLINE THE FROG-P KIT CONSISTS OF:

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy

Type of installation. external motor. underground motor. Leaf max length (m) Leaf max length (m) Max leaf weight (kg) V V V

NICE TOO, STYLISH AND VERSATILE NEW TELESCOPIC GEARMOTOR FOR SWING GATES. THE IDEAL SOLUTION FOR RESIDENTIAL OR PEDESTRIAN GATES.

NICE WIDE THE BARRIER GATE OPERATOR SYSTEM EASY TO INSTALL, SAFE TO USE AND SIMPLE TO MANAGE.

In this manual you can find how to connect the valve to a standard electric box from Certikin (point 3) or to a DUAL SPEED electric box (point 4).

OMATION FOR SLIDING GATES LINESTAR INSTALLATION MANUAL

TECHNICAL DATA HYDRAULIC UNIT

CHECKING AND MAINTENANCE:

UNDERGROUND OPERATOR FOR SWING GATES 119AS45EN. Installation manual FROG-A / FROG-AV / FROG-AE. English

AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG

Troubleshooting Guide

TOONA 5 HS. Quick manoeuvres: 90 opening in about 16* seconds.

HÖRMANN DSA 100 DSA 100 L DSA 200 DSA 200L. page 1

Ditec BOX Balanced up and over doors

BARRY BARRIER GATE AUTOMATION

Oil-hydraulic operator for swinging gates

Installing the gate post bracket with the cardboard arm template

Spring Return DuraDrive Two-Position Actuator

Gates and doors automation 07/2007. Products - made in Italy

BISON 20 OM BISON 25 OTI

MOTORS RESIDENCIAL / INDUSTRIAL

Control panel installation manual for 230 V~ automation with one or two motors D5 S5 JT RF ON TC RP TR R1 OM J7. Electric lock. Flashing light.

Porte 150 Users Manual Swing Gate Opener 24V DC

Ditec PWR Automation system for swing gates with wings up to 5 metres

MBM8 / MBM11- Barriers. Installer and User s manual

KEYSTONE FIGURE 79 PNEUMATIC ACTUATOR OPERATING AND MAINTENANCE INSTRUCTIONS

WEL. Manuale di installazione e manutenzione per automazioni per porte battenti. Installation and maintenance. for swing doors.

CICLÓN ATTUATORE ELETTROMECCANICO IRREVERSIBILE A BRACCIO SNODATO PER CANCELLI A BATTENTE

INSTALLATION AND OWNER S MANUAL MODEL ASW Actuator Swing Gate Operator

DC-44 and DC-88 Series Non Spring Return Electronic Actuator Installation Instructions

SLIDE & OL USER'S AND INSTALLER'S MANUAL V1.0 REV. 06/2017

GENERAL SAFETY... 3 PARTS LIST...

MASTIFF 300/300M SWING GATE OPENER USER MANUAL

CONTROL UNIT BIOS2. Manual for installation. Programmable Control board for wings gates.

User s Guide. Unwinder/Winder 100 FOR. Blizzard 65/90 Spitfire 65/90 Extreme Rockhopper 3 Extreme ValueJet 1604 ValueJet 1614 Viper 65/90 Viper 100

Transcription:

Couper Motori gear for swing gates EN INSTRUCTION MNUL MDE IN ITLY

1 - GENERL DESCRIPTION 1 - WRNINGS Unfulfilment of the below listed direction will release the KING gates srl, from any responsibility for damage caused to people or things. -Do not modify the product in any part. -To optimize the functioning of the automation, King gates accessories only.-installing, testing and first functioning have to observe the laws in force. -The gear-motor doesn t require any maintenance because provided with a permament lubrification system. -Disposal of waste material has to observe local regulations. 1B - VILBLE VERSION VILBLE VERSION Code Couper 24 Mechanical Motor stop 24 Vdc (1) Fixing kit Wing max dimensions 2m - 250 kg COUPER 24 TECHNICL DT Power supply Gear motor Power Speed Travel Work cycle Working temperature Max length of the gate Max weight of the gate Protection level Weight Dimensions (Vac) 230 (Vac/Vdc) 24 (W) 80 (m/sec) 0,013 0,016 (mm) 360 (IP) 44 (kg) 6 (m) 2 (kg) 250 (%) 50 (mm) 100x104x780 ( C) -20 +50

2 - TYPICL SYSTEM 2 - TYPICL SYSTEM C F G B D2 D1 E1 H H H E2 - Gear-motor B - Control unit C - Flash-light with antenna D - Photocell in closing E - Photocell in opening F - Key selector G - Warning sign H - Stop locks 2B - TYPICL CONNECTION ND CBLE SECTION + - C nt L N RG58 (dist max 5m) 0,5mm2 (dist max 20m) 0,5mm2 (dist max 20m) 1,5mm2 (dist max 20m) 1,5mm2 (dist max 20m) B 0,5mm2 (dist max 50m) 0,5mm2 (dist max 50m) min 3X0,75 F Tx D1 Rx D2 + - + - NC - PHO2 min 3X0,75 Tx E1 Rx E2 + - + - NC - PHO2

2C - DIMENSIONS 104 780 100 Front braket 130mm Rear braket 130mm 40mm 80mm Rear vertical braket 80mm 130mm

3 - BRCKETS INSTLLTION SCHEME 3 - HOW TO USE GRPH Measure "E", and draw a horizontal line in graph at the read measure. Choose a point on the drawn line, considering the desired opening angle, suitable to the column. Draw a vertical line from that point and determinate the value. Verify that the value allows the fixing of the rear bracket to continue the installation, otherwise choose another point on the scheme. Finally, bring the piston to the limit of the travel to fix the bracket on the rear door (see the following picture). This, however, by avoiding that the sliding pivot touches the aluminium body. E

3C - GRPH 220 210 200 190 90 E (mm) 180 170 160 100 150 140 110 130 120 140 160 180 200 (mm) If the installation measures are not properly followed, the atomation could not work correctly. For example: - Cyclical trends, and sudden accelerations - Noise of the motor - Limited opening degree or absent opening (in case of motor counter-lever fixed)

4 - INSTLLTION 4 - INTRODCTION Read the instructions with care before installing the product. The producer disclaims all responsibility for any damage or bad functioning caused by non-observance of the instructions or bad connection that may result in poor safety and functioning of the gear-motor. 4B - STIRRUPS HEIGHT Fix the stirrups allowing 35 mm between the faces in order to fix the gear-motor horizontally. (see pic.1). 1 35mm 4C - FIXING THE GER-MOTOR TO THE STIRRUPS Fixing the gear-motor to the back stirrup. (see pic.2). Fixing the gear-motor to the front stirrup. (see pic.3). 2 3

5 - MNUL CONTROL 5 - INTRODUCTION! Before operating the manual release disconnect the power Manual control has been thought for manual opening of the gate in case of power-cut or motor breakdown. 5B - RELESE INSTRUCTION (see pic.4). - Open the manual release cover - Insert the key in the cylinder and turn it of 90 anticlockwise direction. 4 5C - RESTORTION INSTRUCTION (see pic.5) - Insert the key in the cylinder and turn it of 90 anticlockwise direction. - Close the manual release cover 5

6 - ELECTRICL CONNECTION 6 - CONNECTION TO THE POWER STTION To connect the gear motor to the control unit, proceed as follows: 01. Remove the lid of the gear motor as shown in fig. 12; 02. Slacken the gearmotor cable clamp, thread the connecting cable through the hole and connect the three electric wires 03. Replace lid on gear motor. To check the connections, direction of rotation of the motor, phase shift in the movement of the leaves and setting the limit switch, refer to the instructions manual of the control unit. 6 7 - STOP DJUSTMENT 7 - INTRODUCTION The mechanical-stop enables to stop the gate at a required position, avoiding the door hitting the stopping devices. 7B - INSTRUCTION FOR THE REGOLTION INSTRUCTION (vedi fig.7): -Set the gear-motor on manual functioning (pic.4). -Unscrew the screw on the mechanical-stop (B). -Move the door to its wide open desired position. -Place the mechanical-stop next to the sliding pin (C), as a block. -Screw in the screw tightly. -Set the gear-motor on automatic functioning (pic.5). 7 B C D! The gear-motor are manually provided with mechanical stops in open position. In case of lack of external mechanical stops in closing position, it is possible to buy the optional mechanical limit switch.