TMT Boxer 24v slider motor installation notes from EasyGate

Similar documents
Sliding Gate Operator. User's Manual WARNING THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN

Instruction Manual for the. E-SL 450 Series

Sliding Gate Operator User's Manual

Sliding Gate Operator User's Manual

DKC400Y AC Sliding Gate Installation Manual. Sliding Gate Opener. Model: DKC400Y. Installation Manual WARNING

Installing the gate post bracket with the cardboard arm template

SKC400U SLIDING GATE OPENER OWNER S MANUAL

Installing the gate post bracket with the cardboard arm template

PY600AC Sliding Gate Opener User Manual

Installation and Set Up Instructions

LIFTMASTER MAGIC BUTTON FS10 & LPK5 FAST SLIDER

DESIGNED FOR RESIDENTIAL APPLICATION KIT PL600/PL1000 SLIDING GATE OPENERS

Letron Auto Gates (Australia) Pty. Ltd. User s Installation Manual

DTS SECURITY P.O.BOX 3399 EDENVALE 1610 Base plate-mounting instructions TELEPHONE

Table of Contents. General Safety Preparation for Installation Parts List Optional Accessories Part List... 5

SKC-500DC SLIDING GATE OPENER OWNER S MANUAL

Installation and Set Up Instructions

HIGH SPEED SLIDING GATE OPENER

AgriWheel Single Gate Kit Low Voltage & Solar. Installation & Operating Instructions

The House of Gate Automation

E-SL 450BD Series INSTRUCTION MANUAL WARNING USER DRIVEN MANUAL*

LI-2B Installation Manual

V200 USER MANUAL SWING GATE OPENER. 100kg 1.5m. 100kg 1.5m

FROG KIT. Installation Instructions for a Pair of gates... TECHNICAL HELPLINE THE FROG-P KIT CONSISTS OF:

Bulletin 1494C Cable Operated Disconnect Switch Kit (400A) Installation Instructions (Cat 1494C- _ Series 2 : 400A)

SLIDING GATE OPENER USER MANUAL

Rolling Door Operator User s Manual

Roll Up Door Operator

KVM 25 OPERATION MANUAL / INSTALLER

OPERATOR SHAFT-120. Installation and Operating Manual CONTENTS GENERAL INFORMATION SAFETY INSTRUCTIONS OPERATOR UNIT OPERATOR INSTALLATION

IMPORTANT SAFETY RECOMMENDATIONS

contents OPERATOR Maintenance SHAFT-120 Installation and Operating Manual DoorHan, 2012

Gate Operators, Inc. Model 7100UL Residential & Medium Duty Commercial Slide Gate Operator INSTALLATION MANUAL

Installation and Set Up Instructions

PAGE. 20. Connecting an intercom.

SWING GATE OPENER SW300 SERIES

Sliding Gate Opener User s Manual

Safety Installation Information Single Gate Opener Parts List...4. Dual Gate Opener Parts List...5. Technical Specifications & Features...

F ERNI K I T THE FERNI-S KIT CONSISTS OF:

Index. COMPACT domestic gate operator

INSTALLATION & OWNERS MANUAL

DTS 412/512/624 SLIDING GATE MOTOR INSTALLATION MANUAL

SWING GATE OPENERS 24V DC GEAR MOTOR

IMPORTANT SAFETY RECOMMENDATIONS

contents Installation Maintenance DOOR OPERATOR SLIDING-1300/2100 Installation and Operating Manual DoorHan, 2012

E-S Allegiant Series Single Swing and Dual Swing Gate Opener

AUTOMATIC CONTROL ROLLING DOOR OPENER

DOMESTIC SLIDING GATE OPERATOR

Owner s Manual. For SOLAR BOOM GATE. Model: CA-5000 SOLAR

Hunter Automatics HA-8. Installation Manual

SL100DCx series Sliding gate system Installation guide

GENERAL SAFETY... 3 PARTS LIST...

SWING GATE OPENERS 24V DC GEAR MOTOR

YG101 SWING GATE OPENER OWNER S MANUAL

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

Model 2300DL Installation Guide

R3R5 quick setup guide ROTARY SWING GATE OPERATOR

INSTALLATION INSTRUCTIONS FOR ELECTRIC CHOKE KIT P/Ns , S, &

Installation and Maintenancee Manual

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

ET-500 AUTOMATIC SLIDE GATE MOTOR INSTALLER S MANUAL FOR ACDC500 & DC500 MODELS


Model 2300JL Installation Guide

USER MANUAL. Automated Vehicular Boom Gate. Version: 1.0 Date: March, 2015

CB-9 CONTROL BOARD INSTRUCTION MANUAL

ROSSO EVO User s and Installer s manual

Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Saimatic Aster Gate Operator, Automation System Manual. 110V or 220V

Installation and a Maintenancee Manual

Delete top and bottom bor SDO - C

ASSA ABLOY Series Multi-Point Hold Open Installation and Instruction Manual

APOLLO Gate Operators, Inc.

General Information...3. Features...5. Parts Identification...6. Installation...8. Alternate Installation Electrical Fine Tuning...

Installation Manual E8-400 E8-500 E Solar or Electric Systems

WIRING THE HEATER POWER SUPPLY

PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR

Remote Control Electric Curtain Track User Manual

APOLLO Gate Operators, Inc.


APOLLO Gate Operators, Inc.

TC1000 Service Manual SALES: CUSTOMER SERVICE:

System Benefits. Index. Style 840The amazingly versatile woven wire partition. The Style 840 Solution

Jet 500/ 800 Users Manual Sliding Gate Opener

SPINKS SCALES ROOSTER SCALES MODELS: 250 # 350 # 600 # INSTRUCTIONS/OPERATOR S MANUAL For. JANUARY, 2000 Manual No (Rev.

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

FOR CLASS I, II, III, IV VEHICULAR GATE OPERATORS

INSTALLATION AND OWNERS MANUAL

MAZDA BT-50 (October 2011 Production Onwards) 1 & 3 PIECE HARD TONNEAU REMOTE LOCKING KIT INSTALLATION INSTRUCTIONS

Linear Actuator Swing Gate Operator Installation Manual Model # LA405-24

access

VEHICLE AND PEDESTRIAN CONTROL

GATES-ELECTRIC AND MECHANICAL SELF CLOSING 2000 SERIES

Power Break II Circuit Breaker Accessories Motor Operator Mechanism

R3 Roller Garage Door Opener

Instruction Manual MB4 Rolling garage door opener

Tech Note Truck 14 & 15.5 Twin Plate Cast Iron Type Installation Guidelines

General Information...3. Features...5. Parts Identification...6. Installation...8. Alternate Installation Electrical Fine Tuning...

SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE. Comfort 800E/1000E

Transcription:

TMT Boxer 24v slider motor installation notes from EasyGate Install Physical Gate Stops Physical Gate Stops MUST be installed at each end of your gate. If the Limit Switch on the boxer motor fails to stop a gate cycle, the Gate Stops will prevent gate falling off the guide rollers and causing possible injury or damage. Installing Motor Preparation of the Concrete Ground Surface (Base) for Motor Mounting. Make sure that the ground surface for the motor installation is solid and levelled. A good Base is paramount to the proper operation of the auto gate system. If installing cables place these 300mm from your wall/post and approx. 220mm in from the corner of the wall/post. The motor mounting plate is 170mm deep x 250mm wide. Position the motor mounting plate (side nearest the gate) approx. 150-160mm from the wall/post and approx. 50mm in from your post driveway corner point. Top View Base Footprint Post 55mm Gate 170mm 50mm 250mm Motor Cables from the Control Panel to the Motor can be pre-embedded in the Base should concealed wiring be preferred. Prepare for motor cable 2 core x 1.5mm or 2.5mm from the transformer. For option devices such as wired keypad, infer-red beams, loop detectors etc. network cable, or Cat-5 or cat.6. NOTE: You may need to raise the motor to allow the gear rack to fasten properly to your gate bottom rail so check this first by placing a gear rack on top of the sprocket alongside the gate and

allow for the fastener thickness after installation. Open/close the gate as the gate may have a bend in it. There are 3 typical ways to fasten the motor to your concrete. Option 1: If your gate is manufactured with 100 x 50 mm rectangular bottom rail such as the EasyGate low profile model and sits about 40mm off the ground, you can bolt the motor directly to the concrete without the need for motor plate risers. Hint: Option 2 and 3 are good for rising the motor to allow cables to be installed freely under the motor so you do not need to be too accurate with your cable location. Option 2: If your EasyGate is fitted with the standard wheel that rises the gate to approx. 50mm from the ground you can use the (optional) 25mm high spacers available from EasyGate to lift the motor. Position these under the left and right sides of the motor. Option 3: If your gate is above 50mm off the ground you can use the mounting plate supplied with the Boxer motor and 4 threaded rods in each corner to act as pylons. The rods have anchor pins that are drilled and hammered/pressed into your concrete pad. Thread the rod into the anchors and place a nut on each rod to the desired height. Place the mounting plate on next, followed by the motor, washers and fasten together with 4 more nuts. Installing the gear rack to the gate: For your gate to function smoothly you will need to install the gear rack correctly. The outcome is to have a 2mm gap between your sprocket and the valley of the gear rack throughout the length of the gate. Temporarily raise the motor by another 2mm using bolt-washer spacers under the motor mounting bolts. Remove once all the gear rack is installed and motor secured to the ground plate) Release the auto gate to emergency release so that the gear wheel rotates freely for the alignment and installation of the gear-rack. Lay all gear rack (on the ground) along the length of the gate. Check end rack supports for best position of a gear rack lug each side of the sprocket at the fully open/close. We strongly Recommend you leave gear rack over hanging (approx. 100mm) until after you have fitted your limit cams and only then cut off any extra with a steel hacksaw as the gear rack has a steel rod inserted in the nylon casting for strength.

Rest the first gear-rack on the gear wheel, ensure that the gear rack is level, and secure the gearrack onto the gate using the fastenings provided. Move the gate 1m and repeat as above until all gear-rack have been installed. Do not fasten where wheels may be contacted as this will increase gate moving resistance dramatically. Remove the Washer / Spacer from the Motor, and the gap of 2mm between the gear wheel and the gear-rack is automatically achieved. Check to ensure consistent meshing between the gear-rack with the gear wheel over the entire length of the gate. Loosen the screw on the gear-rack to adjust the position of the gear rack if necessary. 2mm gap Important Note: Gear Wheel and Gear Rack life depends almost entirely on their correct meshing. Install Limit Cams Limit Cams (2 x silver brackets) MUST be installed at each end of your gate Gear Rack. Supplied is a right (SX) and a left (DX) when installed they are designed to trigger the Limit Switch to stop the gate cycle BEFORE contact with physical gate stops. Stand-alone Transformer (optional) This DIY transformer will reduce the 240v input to a safer 24v output. It can be place at your 240v power plug outlet. From there you can then run (up to about 80m) a low voltage cable length to the Boxer gate automation using a minimum of 1.5mm 2 core cable. It will only have 24v AC running through it. Connect to the blade fuse mounted under the battery box. It will not matter which configuration you connect as it is alternating current (AC). Removing control board plastic protective cover

Make sure the clutch lever is in the down position. The grey plastic cover that protects the control board can be removed using your left index finger to pull back and away the tab in on the left top corner. The cover is hinged on the right side. Tuning remotes On the control board press the Rf Learn button (TOP BUTTON on right) once until the blue LED light shines. On your remote press the top LEFT button once. This is called button A. Blue light flashes on the control board to confirm tuning of remote. Pedestrian mode using your remote You control board is pre-set with SW2 (black Switch) to ON. The SW2 is located in the bottom right corner of the control board. The top right button on your remote (button B) activates a pedestrian mode or partial opening cycle. You can only activate the pedestrian mode with your remote. To change button B to Button D on your remote place switch 5 to OFF. To remove the pedestrian function turn SW2 to OFF and place SW6 white switch #4 and 5 to OFF. Programme Gate Opening Direction There are 2 locations that you can install your gate motor. Right or Left of your driveway (facing your gate from the side the motor will be installed). The Left Side is the most popular with the motor sprocket rotating counter-clockwise opening the gate from right to left. The factory setting is for a Left Side install. F1-1 Right Side install has the motor sprocket rotating clockwise opening the gate from left to right. You will need to change the programme Opening Direction to F1-0 Systems Learning Systems learning will allow the Control board to register your gate factors such as operational resistance, opening/closing cycle times, speed etc. NOTE: Gate must be closed! Warning: Check that both fully open and full closed limit cams are in place on the gear rack and are functioning correctly. Check both fully open and fully closed physical stops are securely in place. Before starting system learning you must first have a working transmitter. On the control board press the Rf Learn button (TOP BUTTON on right) once until the blue LED light shines. On your remote press the top LEFT button once. Blue light flashes to confirm tuning of remote. Step 1: Press the Set button for 3-5 seconds. (3 RD BUTTON FROM TOP) You will see the display change to RUN then go to F1 Step 2: Simultaneously press the Set and the Down button (4 th BUTTON FROM TOP) for up to 5 seconds until the LED display shows LEA Step 3: You now have less than 5 seconds to press the left top button of your remote to activate the motor opening cycle and systems learning will commence. LED display shows ARN

Warning: Gate will start moving so keep clear of moving parts. Step 4: Gate will commence an open cycle until Open Cam contacts with Limit Switch and stops the motor. A second or 2 later the gate will start a close cycle until close cam contacts Limit Switch and stops the motor. System-Learning is now complete. Test the gate opener is working correctly. If the gate loads up on your physical stops and stops this will affect the reliability of the gate operation. Adjust the limit cams so the gate just touches the stopper and no more on completion of a cycle. You can now connect optional devices by removing the terminal block (pulls off) first and inserting your wires in the correct location as per the labels. This is so you do not blow the system up accidently. Connecting Exit Button: Terminal 10 (Pb) and 11 (GRD) to activate open/stop/close Connecting Intercom and keypads: Terminal 10 (Pb) and 11 (GRD) to activate open/stop/close. Terminal 5 (+13.75) is positive 13v and 6 (GRD) is the negative. Connecting the IR beams: Important Note: Once beams are installed you must also SW6 DIP white switch 1 to OFF (top switch found in the bottom Right corner of the board). You will also need to loop terminal 2 and 5 on the receiver beam. The system is factory set to be used without the beams fitted so there is no need to loop terminal 7 (PH1) to ground as this is done electronically. To Install IR Beams you will need power to the IR beams. Terminal 6 (GND) is negative and terminal 9 (PH+) is positive 12-13v DC. Connect the NC of the IR Beam to Terminal 7 (Ph1) and the COM of the IR Beam to terminal 6 (GND). Antenna The Boxer is fitted with a tuned antenna positioned on top of the control board mounting plate. Be careful not to damage the antenna wire that passes through the control board cover and connects to the terminal block in the bottom right corner of the control board. You can remove the antenna when working on the control board and replace when finished. Position the earth wire to the GRD and the centre core wire to ANT (top connector).

Trouble shooting Control board Locked up If you change the speed of the motor after you have done Systems Learning you may find the control board will lock-up. You will need to repeat systems learning The replacement FUSE for the stand-alone transformer is 20 amp (20A250V)