GRUNDFOS DATA BOOKLET. CHV booster. Hydro Pack, Hydro Dome 50 Hz

Similar documents
GRUNDFOS DATA BOOKLET. Hydro 1000 G - X. Grundfos Hydro 1000 G - X booster sets with 1-4 CR pumps 50 Hz

GRUNDFOS DATA BOOKLET. Hydro Grundfos Hydro 1000 booster sets with 1-4 CR pumps 50 Hz

GRUNDFOS DATA BOOKLET. Hydro MPC. Booster systems with 2 to 6 pumps 50 Hz

GRUNDFOS DATA BOOKLET. Hydro MPC. Booster systems with 2 to 6 pumps 50 Hz

GRUNDFOS DATA BOOKLET. Self-priming multistage pumps 50 Hz

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete booster systems 50/60 Hz

GRUNDFOS DATA BOOKLET. Fire NKF. Grundfos fire systems. Fire pump sets with electrically and diesel-powered pumps according to DBI 251/CEA4001

18D according to ATEX

Company name: Created by: Phone: Date: Note! Product picture may differ from actual product

GRUNDFOS DATA BOOKLET UPM2, UPM GEO, UPM2K. Circulator pumps. 50/60 Hz

GRUNDFOS DATA BOOKLET NS, PF. 50 Hz

Grundfos Home Booster

Renewable Solar Inverter, RSI

Grundfos solar surface pump

GRUNDFOS DATA BOOKLET. Hydro Multi-B. Booster systems with 2 or 3 pumps. 50/60 Hz

GRUNDFOS DATA BOOKLET. Self-priming. 50/60 Hz

Renewable Solar Inverter, RSI

GRUNDFOS PRODUCT GUIDE CH, CHN. Horizontal multistage end-suction pumps

Note! Product picture may differ from actual product

Company name: Created by: Phone: Note! Product picture may differ from actual product

Cartridge pressure switch Type CB

Grundfos solar surface pump

GRUNDFOS DATA BOOKLET. Grundfos RSI. Renewable solar inverter for pump control kw

CR, CRI, CRN, CRE, CRIE, CRNE

CR, CRI, CRN, CRE, CRIE, CRNE

Lenntech GRUNDFOS DATA BOOKLET. CME 15. Horizontal, multistage centrifugal pumps 50/60 Hz

CR, CRI, CRN, CRE, CRIE, CRNE

20, 30, 40, 55 Turbo. Alpha SERIES. Variable speed; maximum power at flywheel at 3000 r/min: kw; bhp

JFC Series Rack & Pinion Actuators SGS MD 2006/42/EC

Belimo Applications Air handling units

Special conveyor chains

CR, CRI, CRN, CRE, CRIE, CRNE

GRUNDFOS DATA BOOKLET. Hydro Multi-E. Booster systems with 2 to 3 CRE pumps 60 Hz

GRUNDFOS DATA BOOKLET MTS. Screw pumps 50/60 Hz

Multilift M, MD, MDV, and MD1 ranges

GRUNDFOS DATA BOOKLET. Grundfos UPBasic. Circulator pumps 50 Hz

CM1-5 S-R-I-E-AQQE C-A-A-N

CM1-3 S-R-I-E-AQQE C-A-A-N

GRUNDFOS DATA BOOKLET. Hydro Multi-B. Booster systems with 2 or 3 pumps 60 Hz. Drinking Water System Component NSF / ANSI 61 NSF / ANSI 372

Owner s Guide for. *24 Months engine warranty on Vanguard powered sets

GRUNDFOS PRODUCT GUIDE. BoosterpaQ Hydro MPC. Booster sets with 2 to 6 pumps 60 Hz

CR, CRI, CRN, CRE, CRIE, CRNE

CR, CRI, CRN, CRE, CRIE, CRNE

CMB-SP 5-28 I-C-A-C-B-A

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

CR, CRI, CRN, CRE, CRIE, CRNE

CMB-SP 1-54 I-C-A-C-C-A

Clamping systems. LinClamp/HLGClamp. LinClamp SA. LinClamp SK. LinClamp A

Series 32D Electronic Pressure Switch for Hydraulic and High Pressure Applications. Series 18D Hydraulic. Pressure Switch

GRUNDFOS DATA BOOKLET MTR(E), MTH, MTA. Immersible pumps 50/60 Hz

24 Vdc ELECTRONIC CONTROL UNIT FOR SWING GATES USE INSTRUCTIONS - INSTALLATION INSTRUCTIONS

CM3-6 A-R-G-E-AQQE C-A-A-N

CMB-SP 3-28 I-C-A-C-A-A

CM5-5 A-R-A-E-AVBE C-A-A-N

MECHANICAL ENGINEERING


Dash8 - Q400 - Ice & Rain Protection

Grundfos pressure boosting systems

CM5-6 A-R-A-E-AQQE C-A-A-N

CM5-5 A-R-G-V-AQQV F-A-A-N

GRUNDFOS DATA BOOKLET. Hydro Multi-E. Booster systems with 2 to 3 CRE pumps 60 Hz

GRUNDFOS DATA BOOKLET. Control HVAC. For variable-primary-flow systems

Simplex, duplex and triplex chains Special chains CHAINS

CM5-9 A-R-I-E-AQQE F-A-A-N

CM10-3 A-R-G-V-AQQV F-A-A-N

CM15-1 A-R-I-V-AQQV C-A-A-N

Contents. Accessories Pipework connection Counter flanges for LCR Counter flanges for LCRN

CM25-1 A-R-G-E-AQQE C-A-A-N

GRUNDFOS DATA BOOKLET. Fire CRFF. Grundfos fire systems. VdS-approved CR pumps for fire systems 50 Hz

CM3-5 A-R-I-E-AQQE F-A-A-N

ALTI-NEXIS V OPERATING LIMITS APPLICATIONS ADVANTAGES. Flow rates up to: 320 m 3 /h Delivery head up to: Maximum operating pressure:

CM1-8 A-R-I-E-AQQE F-A-A-N

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

CM3-11 A-R-G-E-AQQE F-A-A-N

CM1-2 A-R-A-E-AQQE F-A-A-N

CMBE Booster. Lenntech. Description 50/60 Hz. Horizontal, multistage centrifugal boosters

MD x400V. Grundfos pump GRUNDFOS DATA BOOKLET

GRUNDFOS INSTRUCTIONS. Hydro MPC. Installation and operating instructions

Set 2 Mini Pust APB50B

MTB /183 A-F-A-BQQV 400D-2 11kW

CRN45-10 A-F-G-V-HQQV 3x400/ HZ

TP /2-A-F-A-BUBE 1X230 50HZ

INSTALLATION AND OPERATING INSTRUCTIONS MANUAL Owner s manual FIXED SPEED BOOSTER SETS SERIES:

Reduction of the suction pressure of a liquid ring vacuum pump with a supersonic gas ejector

DP A.2.50B. Grundfos pump GRUNDFOS DATA BOOKLET

Hydro MPC BoosterpaQ GRUNDFOS PRODUCT GUIDE. Booster sets with 2 to 6 pumps 60 Hz. Single & Multi-Pump Systems ANSI / NSF61

CR45-10 A-F-A-E-HQQE 3x400/ HZ

2 EURO PUMP SETS. GENERAL DATA Applications. Construction features - components

Pumps Motors ISO 9001 Company

CRN45-5 A-F-G-V-HQQV 3x400/ HZ

CM5-11 A-R-G-E-AQQE F-A-A-N

CM1-6 A-R-I-E-AQQE F-A-A-N

MTB /158 A-F-A-BQQV 400D-2 5,5kW

CR1S-6 A-A-A-E-HQQE 1x220/240 50HZ

CR45-5 A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

SDE030 SDE060. Directional control valves with direct acting solenoid

CR10-01 A-A-A-E-HQQE 1x220/ HZ

OPTIMUM PERFORMANCE AND APPLICATION FIT

CR A-F-A-E-HQQE 3x400/ HZ

Transcription:

GRUNDFOS DATA BOOKLET CV booster ydro Pack, ydro Dome 5 z

Contents ydro Pack General data Performance range Page 3 Alications Page 4 General descrition Page 4 Oerating conditions Page 4 Tye key Page 4 Technical data Page 4 Product range Page 5 Function Page 5 Oeration Page 5 Performance curves, technical data CV 2 Page 6 CV 4 Page 7 Main comonents, single-hase Page 8 Main comonents, three-hase Page 8 Accessories ydro Dome General data Page 9 Performance range Page 1 Alications Page 11 General descrition Page 11 Oerating conditions Page 11 Tye key Page 11 Technical data Page 11 Product range Page 12 Function Page 12 Oeration Page 12 Performance curves, technical data CV 2 Page 14 CV 4 Page 17 Materials Page 18 Accessories Tank selection Page 19 ydro Pack ydro Dome Page 2 2

General data ydro Pack General data ydro Pack Performance range kpa] 1 1 ydro Pack 5 z ISO 996 Annex A 9 8 8 7 6 6 5 4 4 CV 2 CV 4 3 2 2 1 1 2 3 4 5 6 7 8 9 Q [m³/h]..5 1. 1.5 2. 2.5 Q [l/s] TM1 7819 49 3

General data ydro Pack Alications Grundfos ydro Pack booster sets are designed for boosting of clean water in small waterworks small blocks of flats hotels stores industrial lants, hositals schools large houses. General descrition The Grundfos ydro Pack booster set consists of a Grundfos CV um mounted on a base frame, and a controller incororating motor rotection (three-hase only). A searate diahragm tank must be installed in connection with the booster set. The um oerates automatically according to the system requirement by means of a ressure switch. The ressure switch is factory-set to zero bar inlet ressure and can be adjusted according to the hydraulic conditions of the uming system. The ydro Pack booster set is sulied as a comlete, re-assembled and tested system (without tank). ydro Pack booster set includes discharge comonents, five-way fitting, ressure switch and controller (three-hase only). Tank and dry-running rotection are available as accessories. To ensure stable oeration, the booster set must be connected to a searate diahragm tank of a suitable size, installed on the floor, see "Pressure tank" age 9 and "Tank selection" age 2. If water is drawn from a reservoir below the um, a non-return valve in the suction ie is required. Oerating conditions Liquid temerature: C to +4 C. Ambient temerature: C to +4 C. Maximum oerating ressure: 1 bar. Maximum oerating ressure = maximum inlet ressure + um head. The maximum oerating ressure is limited by the characteristics of the booster set. The maximum oerating ressure may also be limited by the tank installed. Number of starts/stos er hour:1. Minimum inlet ressure: The minimum inlet ressure in meters head required to avoid cavitation of the booster is calculated as follows: = P b x 1.2 - NPS - f - v - s P b = Barometric ressure NPS = Net Positive Suction ead in metres head f = Friction loss in suction ie s = Safety margin of minimum.5 m. Maximum inlet ressure: The actual inlet ressure lus the ressure against closed valve should always be lower than the maximum oerating ressure, i.e. 1 bar. Tye key Examle ydro Pack 1 CV 4-4 3 x 4 V 5 z Tye Number of ums Pum tye Voltage/frequency Technical data Power suly: 1 x 22-24 V, 5 z 3 x 38-415 V, 5 z. Power range: U to 2.1 kw for each um, Direct-on-line starting Enclosure class: Motor: IP 54 Control CS 13 for three-hase motor: IP 65 Pressure switch: IP 54 Pum tye: CV. 4

General data ydro Pack Product range ydro Pack, CV 2 ydro Pack Voltage Power P 1 [W] Product no. CV 2-4 1 x 22-24 V 6 96 4 88 77 CV 2-5 1 x 22-24 V 7 96 4 88 78 CV 2-6 1 x 22-24 V 87 96 4 88 79 CV 2-4 3 x 38-415 V 58 96 4 88 87 CV 2-5 3 x 38-415 V 7 96 4 88 88 CV 2-6 3 x 38-415 V 86 96 4 88 89 CV 2-8 3 x 38-415 V 112 96 4 88 9 CV 2-1 3 x 38-415 V 127 96 4 88 91 ydro Pack, CV 4 ydro Pack Voltage Power P 1 [W] Product no. CV 4-4 1 x 22-24 V 95 96 4 88 82 CV 4-5 1 x 22-24 V 124 96 4 88 83 CV 4-6 1 x 22-24 V 145 96 4 88 84 CV 4-4 3 x 38-415 V 96 96 4 88 92 CV 4-5 3 x 38-415 V 124 96 4 88 93 CV 4-6 3 x 38-415 V 15 96 4 88 94 CV 4-8 3 x 38-415 V 177 96 4 88 95 CV 4-1 3 x 38-415 V 27 96 4 88 96 Function The um oerates automatically according to system requirement by means of a ressure switch. When the ta is oened, water is drawn from the diahragm tank. When, consequently, the ressure dros to the cut-in ressure level, the um will be cut in until the erformance of the um corresonds to the requirement. When the water consumtion falls and the discharge ressure reaches the cut-out ressure level, the ressure switch will cut out the um. Oeration Single-hase versions The ressure switch of the single-hase variants has an on/off switch. Motors have built-in thermal switch ON/OFF switch Pressure switch Three-hase versions Aart from the ressure switch for automatic oeration, the three-hase versions incororate a CS 13 controller with the following oerating buttons: main switch start and sto ush buttons Furthermore, the ydro Pack booster sets feature: Automatic circuit breaker rotecting the motor against short circuit and overload. In addition, the following is available as accessory. See "Accessories" age 9. -dry-running rotection by means of an additional ressure switch or level switch. CS 13 controller TM1 7843 422 Cut-out Cut-in ressure TM1 7853 4999 Main switch Sto Start TM1 7844 4999 5

Technical data ydro Pack CV 2 CV 2 [kpa] 1 8 6 4 2 1 9 8 7 6 5 4 3 2 1-1 -8-6 -5-4 CV 2 5 z ISO 996 Annex A..5 1. 1.5 2. 2.5 3. Q [m³/h]..2.4.6.8 Q [l/s] technical data TM1 7815 3Performance curves, CV 2 Single-hase Three-hase 83 1 13 264 73 24 A TM1 7845 422 86 267 73 24 287 13 TM1 7846 422 Electrical data, dimensions and weights Motor P 1 /P 2 [W] I 1/1 [A] Pum tye 1~ 3~ 1~ 3~ 1~ 3~ 1~ 1~ 1~ 3~ CV 2-4 6/4 58/42 3 1.1 1 7.5 427 15.2 18 CV 2-5 7/47 7/5 3.4 1.3 1 7.5 445 294 15.5 18.3 CV 2-6 87/6 86/62 4.1 1.5 11 7.5 463 16.4 19.3 CV 2-8 112/8 2. 11 2.9 CV 2-1 127/97 2.4 17 22.9 I st [A] [mm] A [mm] Weight [kg] 6

Technical data ydro Pack CV 4 CV 4 [kpa] 1 8 1 9 8 7-1 -8 CV 4 5 z ISO 996 Annex A 6 4 6 5 4-6 -5-4 3 2 2 1 1 2 3 4 5 6 7 Q [m³/h]..5 1. 1.5 2. Q [l/s] TM1 7817 3 Single-hase Three-hase 83 1 13 264 73 24 A TM1 7845 422 86 267 73 24 287 13 TM1 7846 422 Electrical data, dimensions and weights Motor P 1 /P 2 [W] I 1/1 [A] Pum tye 1~ 3~ 1~ 3~ 1~ 3~ 1~ 1~ 1~ 3~ CV 4-4 95/66 96/66 4.4 1.7 11 7.5 463 294 16.1 18.9 CV 4-5 124/87 124/91 6. 2.3 21 17 523 19.1 21.9 312 CV 4-6 145/11 15/17 6.9 2.7 21 17 55 19.5 22.2 CV 4-8 177/145 3.6 25 27.7 CV 4-1 27/168 3.9 25 28.5 I st [A] [mm] A [mm] Weight [kg] 7

Technical data ydro Pack Main comonents, single-hase Single-hase Pos. Comonent Descrition 1 CV um See CV data booklet 2 Pressure switch Telemecanique - 12 bar 3 Pressure gauge, ø63 mm -1 bar 4 Five-way fitting Connection for R 1 discharge and tank 5 Base late Stainless steel AISI 34 2 1 4 3 5 TM1 7848 422 Main comonents, three-hase Pos. Comonent Descrition 1 CV um See CV data booklet 2 Pressure switch Telemecanique - 12 bar 3 Pressure gauge, ø63 mm -1 bar 4 Five-way fitting Connection for R 1 discharge and tank 5 Base late Stainless steel AISI 34 6 Stand Stainless steel AISI 34 7 Controller CS 13 Three-hase 7 6 2 1 4 3 5 TM1 7849 422 8

Accessories ydro Pack Pressure tank The tank must always be installed on the ressure side of the system. Descrition Caacity [litres] Product no. Diahragm tank 8 96 43 66 67 Bladder tank 8 96 43 66 9 Diahragm tank or bladder tank Non-return valve Other Please contact Grundfos Descrition Dimension Product no. Non-return valve R 1" 95 6 1 Accessories for three-hase only Dry-running rotection kit For rotecting the um against dry-running. Dry-running rotection kit is to be installed on the suction side of the system. Descrition Dimensions/range Product no. Pressure switch kit includes: Pressure switch, cable, suort, ie and vane..4-1.2 bar 96 4 9 9 Level switch Maximum temerature : +5 C. 5 m cable GF 25 38 1 m cable GF 25 39 2 m cable GF 25 4 9

General data ydro Dome General data ydro Dome Performance range kpa] 1 1 ydro Dome 5 z ISO 996 Annex A 9 8 8 7 6 6 5 4 4 CV 2 CV 4 3 2 2 1 2 4 6 8 1 12 14 16 Q [m³/h] 1 2 3 4 Q [l/s] TM1 7814 49 1

General data ydro Dome Alications Grundfos ydro Dome booster sets are designed for boosting of clean water in small waterworks small blocks of flats hotels stores industrial lants hositals schools large houses General descrition The Grundfos ydro Dome booster set consists of two identical Grundfos CV ums mounted in arallel on a common base frame and a control cabinet incororating motor rotection and controller. The ums oerate automatically according to system requirement by means of two ressure switches. The ressure switches are factory-set to zero bar inlet ressure and can be adjusted according to the hydraulic conditions of the uming system. ydro Dome booster sets are sulied as comlete, reassembled and tested systems (without tank). The ydro Dome booster set includes suction and discharge manifolds, isolating valves, ressure gauge, non-return valves, ressure switches and controller. Tank, dry-running rotection and overressure rotection, alarm and emergency kit are available as accessories. To ensure stable oeration, the booster set must be connected to a diahragm tank of a suitable size. See "Pressure tank" age 19 and "Tank selection" age 2. The booster set is designed for two tanks each of 24 litres connected to the discharge manifold. An additional diahragm tank can be installed on the floor in order to fulfil the oerating conditions of the uming system. Oerating conditions Liquid temerature: C to +4 C. Ambient temerature: C to +4 C. Maximum oerating ressure: 1 bar. Maximum oerating ressure = maximum inlet ressure + um head. The maximum oerating ressure is limited by the characteristics of the booster set. The maximum oerating ressure may also be limited by the tank installed. Minimum inlet ressure: The minimum inlet ressure in metres head required to avoid cavitation of the booster is calculated as follows: = P b x 1.2 - NPS - f - v - s P b = Barometric ressure NPS = Net Positive Suction ead in metres head f = Friction loss in suction ie s = Safety margin of minimum.5 m. Maximum inlet ressure: The actual inlet ressure lus the ressure against closed valve should always be lower than the maximum oerating ressure, i.e. 1 bar. Number of starts/stos er hour: 1. Tye key Tye Examle ydro Dome 2 CV 4-5 3 x 4 V 5 z Number of ums Pum tye Voltage/frequency Technical data Power suly : 1 x 22-24 V, 5 z 3 x 38-415 V, 5 z Power range : U to 2.1 kw for each um, Direct-on-line starting. Enclosure class : Motor: IP 54 Control CS 21:IP 54 Control CS 23b:IP 54 Pressure switch:ip 54 Pum tye: CV. 11

General data ydro Dome Product range ydro Dome, CV 2 ydro Dome Voltage Power P 1 [W] Product no. CV 2-5 1 x 22-24 V 7 96 4 88 61 CV 2-6 1 x 22-24 V 87 96 4 88 62 CV 2-8 1 x 22-24 V 19 96 4 88 63 CV 2-5 3 x 38-415 V 7 96 4 88 69 CV 2-6 3 x 38-415 V 86 96 4 88 7 CV 2-8 3 x 38-415 V 112 96 4 88 71 CV 2-1 3 x 38-415 V 127 96 4 88 72 ydro Dome, CV 4 ydro Dome Voltage Power P 1 [W] Product no. CV 4-4 1 x 22-24 V 95 96 43 63 59 CV 4-5 1 x 22-24 V 124 96 4 88 65 CV 4-6 1 x 22-24 V 145 96 4 88 66 CV 4-8 1 x 22-24 V 17 96 4 88 67 CV 4-4 3 x 38-415 V 96 96 43 63 6 CV 4-5 3 x 38-415 V 124 96 4 88 73 CV 4-6 3 x 38-415 V 15 96 4 88 74 CV 4-8 3 x 38-415 V 177 96 4 88 75 CV 4-1 3 x 38-415 V 27 96 4 88 76 Function The ums oerate automatically according to system requirement by means of two ressure switches. When a ta is oened, water is drawn from the diahragm tank. When the ressure dros to the first cut-in ressure level, the first um is cut-in. As the consumtion rises, the second um will be cut in until the erformance of the two ums in oeration corresonds to the requirement. When the water consumtion falls and the discharge ressure reaches the cut-out ressure level, the controller will sto the um which was cut-in first. As the consumtion falls, the second um will be cutout. Oeration Single-hase versions The single-hase versions are controlled by the CS 21 controller. The CS 21 controller features the following functions: Automatic cascade control of ums by means of two ressure switches Automatic change-over at any start/sto cycle Main switch, os. 1. Selector switch with three ositions: Manual oeration/off/automatic oeration, os. 2. Furthermore the ydro Dome features: Short circuit rotection by means of fuses Motors have built-in thermal switch Indicator lights for: -Power on, os. 3. -Pum running, os. 4. -Dry-running alarm, os. 5. In addition, the following is available as accessory. See "Accessories" age 19. Dry-running rotection by means of an additional ressure switch. CS 21 controller 5 3 4 2 1 Cut-out 1 Cut-out 2 Cut-in 1 Cut-in 2 Cascade ste ressure TM1 7852 4999 TM1 7877 422 12

General data ydro Dome Three-hase versions CS 23b controller The three-hase versions are controlled by the CS 23b controller, featuring the following functions: Automatic cascade control of ums by means of two ressure switches. Automatic change-over at any start/sto cycle. Main switch, os. 1. Selector switch for each um with two ositions: Off/automatic oeration, os. 2. Push-button for each um: Manual oeration or resetting of alarm, os. 3. Time control: 5 6 7 3 2 1 1 4 3 2 -Sto delay of the last um: Kees the last um in oeration 1.5 sec. after cut-out ressure is reached in order to avoid a simultaneous sto of the two ums. -After-run delay: Kees ums in oeration 1.5 sec. when the cut-out ressure is reached. -Start delay: Prevents simultaneous start of the two ums. Futhermore the ydro Dome features: Automatic circuit breaker rotecting the motor against short circuit and overload. Indicator lights for: -Oeration and fault, os. 4. -Power on, os. 5. 1 TM1 7878 422 -Dry-running alarm, os. 6. -Overressure alarm, os. 6. -Faulty ressure switches at start/sto, os. 6. -Pressure switch oeration (dry running, overressure, start/sto), os. 7. In addition, the following are available as accessories. See "Accessories" age 19. Dry-running rotection by means of an additional ressure switch or level switch. Overressure rotection by means of an additional ressure switch. Potential-free contact for external alarm. Emergency oeration in case of damage of electronics. 13

Performance curves ydro Dome CV 2 [kpa] 1 8 1 8 CV 2-1 5 z ISO 996 Annex A 6 6 4 2 4 2 1 2 [kpa] 8 8 CV 2-8 6 6 4 4 2 2 1 2 [kpa] 8 8 CV 2-6 6 6 4 4 2 2 1 2 [kpa] 4 3 2 1 4 3 2 1 1 2 CV 2-5 1 2 3 4 5 6 7 8 Q [m³/h]..5 1. 1.5 2. Q [l/s] TM1 7819 49Performance curves, technical data CV 2 14

Technical data ydro Dome CV 2 CV 2 352 455 TM1 7847 422 Electrical data, dimensions and weights Motor P 1 /P 2 [W] I 1/1 [A] Pum tye 1~ 3~ 1~ 3~ 1~ 3~ 1~ 3~ 1~ 3~ CV 2-5 7/47 7/5 3.4 1.3 1 7.5 11 119 5.1 53.6 CV 2-6 87/6 86/62 4.1 1.5 11 7.5 11 119 51.8 55.6 CV 2-8 19/76 112/8 4.9 2. 12 11 11 119 55.4 58.8 CV 2-1 127/97 2.4 17 119 62.8 I st [A] [mm] Weight [kg] 15

Performance curves ydro Dome CV 4 [kpa] 1 8 6 4 2 [kpa] 8 6 4 2 [kpa] 8 6 4 2 [kpa] 4 3 2 1 [kpa] 4 3 2 1 8 6 4 2 8 6 4 2 8 6 4 2 4 3 2 1 4 3 2 CV 4-1 5 z ISO 996 Annex A 1 2 1 2 1 2 1 2 CV 4-8 CV 4-6 CV 4-5 CV 4-4 1 1 1 2 2 4 6 8 1 12 14 16 Q [m³/h] 1 2 3 4 Q [l/s] TM1 7818 49 16

Technical data ydro Dome CV 4 CV 4 352 455 TM1 7847 422 Electrical data, dimensions and weights Motor P 1 /P 2 [W] I 1/1 [A] Pum tye 1~ 3~ 1~ 3~ 1~ 3~ 1~ 3~ 1~ 3~ CV 4-4 95/66 95/66 4.4 1.7 11 7.5 11 119 51.2 53.4 CV 4-5 124/87 124/91 6. 2.3 21 17 11 119 57.2 6.6 CV 4-6 145/11 145/17 6.9 2.7 21 17 11 119 58. 61.4 CV 4-8 17/145 3.6 25 119 72.4 CV 4-1 25/168 3.9 25 119 74. I st [A] [mm] Weight [kg] 17

Technical data ydro Dome CV 4 Materials Pos. Comonent Number Material/ other information 1 Suction manifold (2") 1 Stainless steel AISI 34 2 Discharge manifold (2") 1 Stainless steel AISI 34 3 Base late 1 Stainless steel AISI 34 4 Stand 1 Stainless steel AISI 34 5 Controller 1 Single-hase: CS 21 Three-hase: CS 23b 6 CV um 2 See CV data booklet 7 Ball valve and non-return valve 1¼" 2 Brass, chrome lated 8 Isolating valve 2 Brass, chrome lated 9 Ball valve for tank connection 1" 2 Brass, chrome lated 1 Pressure switch 2 Telemecanique -12 bar 11 Pressure gauge ø63 1-1 bar 5 4 11 1 6 6 8 9 2 3 7 1 TM1 785 422 18

Accessories ydro Dome Dry-running rotection kit Dry-running rotection kit is to be installed on the suction side of the system. Descrition Dimensions/range Product no. Pressure switch kit includes: Pressure switch, cable, suort, ie and vane..4-1.2 bar 96 4 9 9 Level switch Maximum temerature : +5 C Pressure tank 5 m cable GF 25 38 1 m cable GF 25 39 2 m cable GF 25 4 The ressure tank must always be installed on the ressure side of the system. Descrition Caacity (litres) Product no. Diahragm tank 24 96 43 66 64 Bladder tank 24 96 43 66 38 Diahragm tank or bladder tank Other Please contact Grundfos Note: Two 24-litre tanks can be mounted on the discharge manifold. Tanks with other caacities can be mounted searately. Accessories for three-hase only Overressure rotection kit For rotecting the discharge ies against high ressure in case of malfunction of the um ressure switches. The overressure rotection kit is to be installed on the ressure side of the system. Descrition Dimensions/range Product no. Overressure switch kit includes: Pressure switch, cable, suort, ie and vane. 8-1 bar 96 4 9 8 Alarm Descrition Dimensions/range Product no. C.A.N. alarm Emergency oeration kit Emergency oeration kit Acoustic alarm with internal battery 91 19 93 51 Product Descrition Product no. By-ass the electronic module 96 4 9 1 19

Tank selection ydro Pack ydro Dome Pressure tanks To ensure stable oeration, the booster sets must be installed in combination with a diahragm or bladder tank. ydro Pack The five-way fitting has two R 1 threads. One is for the tank and one is for the discharge ie. An 8-litre tank is recommended but this caacity can be otimized according to the system conditions. ydro Dome The discharge manifold is equied with two 1 ball valves for installation of two 24-litre diahragm tanks, each of a maximum diameter of 33 mm. If this tye of installation is not used a bigger tank must be installed on the floor in combination with the booster set. The tank caacity can be calculated as follows: Caacity Q 1 ( 1 + ( Cut in) + ) V ------------------------------------------------------------------------------ 1 = -- 4 n max k V = Tank volume (litres). Q = Mean flow (m 3 /h) of one um only. = Difference between cut-in and cut-out ressure. Cut-in = Cut-in ressure (lowest) (bar). n max = Max starts/stos er hour : 1. k = Constant for diahragm tank re-charge ressure : k =.9. 2

21

22

23

Being resonsible is our foundation Thinking ahead makes it ossible Innovation is the essence V7 15 61 33 11 2 Rel. V7 15 61 33 5 1 GB Subject to alterations. GRUNDFOS A/S. DK-885 Bjerringbro. Denmark Telehone: +45 87 5 14. www.grundfos.com