VINCKE INDUSTRIAL HYDRAULIC VALVES INTRODUCTION

Similar documents
HYDRAULICS VINCKE INDUSTRIAL HYDRAULIC VALVES

Directional Control Valves, electrically operated Type WE 5 Huade América 1

Check-Q-meter type FD

PILOT OPERATED PRESSURE REDUCING VALVE TYPE DR

Pilot operated check valves, Types SV and SL...40B/ (new series) Huade América 1

Size 6 10 up to 31.5 MPa up to 120L/min

DIRECTIONAL CONTROL VALVES CETOP3

Double throttle/check valve Type Z2FS B/ (New Series) Huade América 1

DIRECTIONAL CONTROL VALVES CETOP3

Directional spool valves type SWPN

Directional Control Valve Series 4D01 (DENISON)

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Symbol RH F... GENERAL DESCRIPTION. 4/3- and 4/2- way directional control valves with solenoid operation, heavy duty construction

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid

4/2- and 4/3-way proportional directional valves, direct actuated, without electrical feedback, Type 4WRA. Huade América 1

4/3, 4/2 and 3/2 explosion-proof solenoid directional valve

LOGIC ELEMENTS SERIES 10 LC* LP* /103 ED CARTRIDGE VALVES ISO DIN COVERS FOR CARTRIDGE VALVES ND

Proportional Flow-Control Cartridges, Size 5

Examples 3/2-way valve A T NO: Symbol

PILOT OPERATED PRESSURE RELIEF VALVE TYPE DB/DBW

VINCKE INDUSTRIAL HYDRAULIC VALVES MODULAR VALVES SERIES

Directional cartridge valve tight on both sides type 2URED6 3

HFCETOP3NG6valves. CETOP 3 NG6 valves for hydraulic power packs and other hydraulic applications. HF CETOP 3 NG6 valves

Proportional flow control valve 2-way versiontype 2FRE 6...RC

Flow sharing control block in mono block / sandwich plate design M6-15

Flow sharing control block in mono block / sandwich plate design M6-22

Pressure reducing valve, pilot operated

Vickers Counterbalance Valve. CB Series Mainfold Mounting 315 Bar SAE Flange Mounting L/min Subplate Mounting

Hydraulic Solenoid Valves

Type of operation Depending on requirement either one or two dry DC-solenoid,

S.A. 193 Stefan Cel Mare str., 2400 Sibiu -Romania

Size 10 to 32 up to 35 MPa up to 1100 L/min

Proportional pressure reducing valve

RE / Check-Q-meter type FD, series 2X. Ordering details FD 2X / V * Symbols 1/8. Replaces: 03.92

D4E DIRECT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 41

Pressure relief valve, type DB/DBW...30B/

General Specifications DRV DRV-Exm DRV-Exd

Flow sharing control block in sandwich plate design M7-25

Compact Hydraulics. Compact Hydraulics GoTo Europe

Pressure relief valve, pilot operated

RC /

Pressure reducing valve, pilot operated Type DR

RPEW4-06. Functional Description HA /2005. Solenoid Operated Directional Control Valves with Wirebox 1/2 NPT 1/2 NPT. Replaces HA /2004

Pressure relief valves,type DB3U Huade América 1

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

DIRECTIONAL CONTROL VALVES CETOP 3/NG6

RSP 7-06 R S P FUNCTIONAL DESCRIPTION ORDERING CODE. DIRECTIONAL CONTROL VALVES KE /13 D n 06 p max 32 MPa Q max 80 dm 3 /min

MONOBLOCK DIRECTIONAL CONTROL VALVES

RPE2-04. Functional Description HA /2002. Solenoid Operated Directional Valves. Replaces HA /2000

Double throttle check valve Type Z2FS 10

Size10 to 32 up to 28/35 MPa up to 1100 L/min

Proportional Pressure Relief Valve Series RE*T

SOLENOID DIRECTIONAL VALVE

29 160/ Proportional Pressure Relief Valve Model DBE, (Series 5X) Ordering Code DBE 5X Y G24 1/ PSI (350 bar)

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V

HYDRAULIC PILOT CONTROL UNIT OF SANDWICH PLATE DESIGN

2/ VDMA (ISO ) 5/2-5/3-way CC CO CP. CATALOGUE > Release 8.8 CONTROL > Series 7 valves and solenoid valves GENERAL DATA

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

Pilot operated pressure relief valve

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Chapter 5: Flow Valves

Module 5: Valves. CDX Diesel Hydraulics. Terms and Definitions. Categories of Valves. Types of Pressure Control Valves

Check valve, pilot operated

Directional spool valve type WMM 16 hand lever operated

Proportional pressure reducing valve Types DRE and DREM

3-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Seated valves. Type WV700 NG 6 ISO up to 25 l/min, up to 700 bar. Features. Applications. Design. Technical data

ZRV. Direct Operated Check Valve Series ZRV (Denison)

LUDV control block of sandwich plate design

3/2 and 4/2 directional seat valves with solenoid actuation

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

Introduction. Pressure drops

3/2 Solenoid Cartridge Valve, Size 6

Cartridge Valves Technical Information Directional Valves DCV 03

Proportional pressure reducing valve, pilot operated

ISO 4401 size 07; 315 bar (4500 psi); up to 200 L/min (53 USgpm) General Description

PROPORTIONAL VALVES SERVO VALVES. Maximum operating pressure MPa {kgf/cm 2 } Model [Model No.]

RPEW4-10. Functional Description HA /2012. Solenoid Operated Directional Control Valves with Wirebox. Replaces HA /2006

VALVES RANGE FOR OPEN LOOPS T E C H N I C A L C A T A L O G

Proportional Pressure Reducing Valves Series PE*W (Parker), R4R (Denison)

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 10.05

Type C2 Seat Type Solenoid Pilot Valve

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

Pilot operated check valve

2/2-way poppet valves with solenoid operation Type KSDER1

DSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

5/2 and 5/3 Way Valves

Directional Controls

APV - load sensing VAlVe

Pump Safety Block Model DBA... / DBAW, Series 1X

DSE /117 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 11 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

Pressure Relief Valves

Proportional pressure reducing valve, pilot operated. Type DRE(M) and DRE(M)E. Features. Contents. RE Edition: Replaces: 11.

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

VINCKE HYDRAULIC PUMPS

Transcription:

INTRODUCTION 4 Introduction Hydraulic valves, in addition to the force density advantage of actuators, are what help make hydraulics unique in their control of force, torque and motion. Valves govern direction, pressure and flow of hydraulic fluid, enabling smooth, safe and controlled use of actuators. Every machine both requires and uses valves, varying vastly in execution from a few valves to dozens on one machine. Their use can be as simple as a relief valve to protect your pump and actuator, such as the relief valve built into the kick-off valve on a log splitter. Conversely, the complexity of a hydraulic circuit can be extensive, using a dozen valves per function as can be seen in manifolds, such as a pilot operated valve with dual counterbalance valves, dual flow controls, dual post-compensation and load sensing checks. Directional control valves are often described as the number of ways fluid can travel through itself, and also by the positions available to be shifted into. The ways are equal to the number of work ports, so a 4-way valve will have pressure, tank and A and B work ports. Positions are equal to the number of positional envelopes. For example, one would describe a double acting single-monoblock valve as 4-way, 3-position, or simply a "4/3 valve. Directional valves are available in monoblock or sectional valves, common to the mobilehydraulic industry, as well as subplate mounted industrial type valves such as ISO style installed into manifold blocks. Cartridge valve manufacturers offer many unique products, and allow high levels of creativity with limitless available valve combinations. Pressure valves are components designed to in some way limit pressure. Most pressure valves are based on a poppet being pushed against a seat with an adjustable spring. A relief valve controls maximum pressure for either the entire system or a sub-circuit of it, the lowest spring pressure being the one to open up first. Most other pressure valves are

5 Vincke solenoid valves is designed and tested under innovative concepts to satisfy the advanced needs of currents machines: versatility, reduced power absorbed and safety of use. Solenoid directional valves are used for changing flow direction in hydraulic systems. Technical characteristics Size/Type 6 10 working pressure Oil ports P,A,B 35 31.5 Mpa Oil ports T 16 16 Max. Flow L/min 80 120 Working fluid Mineral oil; phospate-ester Fluid Temperature C -20 70 Viscosity mm²/s 2.8..100 working voltage V DC 12 24 AC 110V/50Hz 220V/50Hz Max. Swich frequency T/h 15000 (DC) 7200 (AC) insulation grade IP65 Weight kg Single solenoid 1.45 DC 1.4 AC 5.1 DC 4.3 AC Double solenoid 1.95 DC 1.9 AC 6.7 DC 5.1 AC Cleanliness The maximum allowable cleanliness of the oil should be according to 9th degree of Standard Ordering code 4VNKSV 6 E OF DC24 4L 4 main ports Electrical Connection: Nominal size 6 Cetop 3 or 10 Cetop 5 4L= DIN connector+led Type of spool E,J,D,C,HA,E etc. 4X= DIN connector without led With spring return = no code DC 24 or DC12 Without spring return = O AC220 AC110 AC24 Without spring return with detent =OF

6 Code symbol 1)Example: Spool symbol H with spool A, ordering code HA Solenoid directional valves are used for changing flow direction in hydraulic systems.

7 CETOP 3 SIZE 6 SPECIFICATION PERFORMANCE CURVE Measured at v=41mm²/s and t=50 C Function Direction Code PDA PDB ADT BDT C 1 1 3 1 D 5 5 3 3 E 3 3 1 1 F 1 3 1 1 G 6 6 9 9 H 2 4 2 2 J 1 1 2 1 L 3 3 4 9 M 2 3 3 3 P 3 1 1 1 8. Spool symbol G in the neutral position PDT

8 Specification working limits With regard to the four-way valve, the normal flow data as show is get from the regular use of two directions of the flow. See tables. If only one flow direction is needed, the maximum flow may be very small in the serious condition. DC 24 12 110 AC 220 110 24, 50HZ Curve Symbol Curve Symbol 4 F P 14 F M 5 J 15 G 6 G H 16 H 7 L 17 E H/OF E/OF J M L 8 C D 18 C D 9 M 10 E H/OF E/OF

9 External dimensions Size of subplate oil port

10 CETOP 5 SIZE 10 SPECIFICATION PERFORMANCE CURVE Measured at v=41mm²/s and t=50 C Function Code Direction PDA PDB ADT BDT C D 2 2 3 3 E 2 2 4 4 F 2 3 3 5 G 3 3 4 6 H 1 1 4 5 L 1 1 4 5 M 1 1 5 1 P 3 2 5 3 4.Spool symbol G in neutral position PDT Specification working limits With regard to the four-way valve, the normal flow data as shown is get from the regular use of two directions of the flow (e.g. P to A, and simultaneous return flow from B to T). See tables, if only one flow direction is needed, for example: when a four port valve which is closed up port A or port B, used as a three-way valve, the maximum flow may be very small in the serious condition. Curve Symbol 1 C D H/OF E/OF M 2 E 4 L J H 6 G 7 F P (1) Return circuit (independent of area ratio)

11 110V 220V Curve Symbol 1 C D E/OF 2 E 3 L M 5 J 6 G 7 F P 8 H External dimensions 201,3 297 201,3 54,4 18,9

12 Size of subplate oil port 201,3 297 201,3 54,4 18,9