Electric amplifiers for proportional valves

Similar documents
Proportional pressure relief valve

Proportional pressure reducing valve, pilot operated

Proportional pressure relief valve, pilot operated

Proportional pressure relief valve with linear curve (Lvdt AC/AC)

Proportional pressure reducing valve, pilot operated, with inductive position transducer

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

Proportional flow control valve, with inductive position transducer

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC)

Servo solenoid valves with on-board electronics (OBE)

3-way servo solenoid valves, cartridge type, pilot operated, with inductive position transducer

Servo solenoid valves with on-board electronics (OBE)

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

4/3 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

Servo solenoid valves with electrical position feedback (Lvdt DC/DC) (ruggedized design)

Servo solenoid valves with positive overlap and on-board electronics

Servo solenoid valves with on-board electronics (OBE)

Servo solenoid valves with positive overlap Position feedback (Lvdt DC/DC ±10 V)

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

Servo solenoid valves with electrical position feedback (Lvdt DC/DC ±10 V)

Proportional pressure relief valve, direct operated, decreasing characteristic curve

3/3 servo directional control valve with mechanical position feedback

Servo solenoid valves with on-board electronics (OBE)

Servo solenoid valves with electrical position feedback (Lvdt AC/AC)

Proportional pressure reducing valve, pilot operated

Proportional flow control valve, 2-way version

Proportional pressure reducing valve, pilot operated

4/3 directional control valve, pilot operated, with electric position feedback and integrated electronics (OBE)

Proportional flow control valve. Type 2FRE. Features. Contents. RE Edition: Replaces: 02.07

Industrial Hydraulics FAQs

2-way proportional throttle valve for block installation

Throttle and throttle check valve

Proportional pressure reducing valve, 3-way variant, pilot operated

Proportional pressure reducing valve, pilot operated

Pressure relief valve, direct operated, with DC motor actuation. Type DBGT. Features. Contents. RE Edition:

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Supply pressure compensator, direct operated

4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

Proportional pressure relief valve, pilot operated

Proportional flow control valve, with integrated pressure compensator

4/3-way servo solenoid directional control valves, pilot operated, with electrical position feedback (Lvdt DC/DC ±10V)

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Directional servo-valve in 4-way design

Directional servo-valve of 4-way design

Electronic pressure switch with two switching outputs

Swivel angle sensor. Type ASSEMBLY KIT VT-SWA-LIN. Contents. Features. RE Edition: Replaces: 04.16

Proportional pressure relief valve, directly operated, rising characteristic curve

4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC)

Proportional pressure reducing valve, pilot operated. Type DRE(M) and DRE(M)E. Features. Contents. RE Edition: Replaces: 11.

4-way directional servo-valve

Mating connectors for controlling electrically operated valves and sensors

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

迅捷 PDF 编辑器. Supply pressure compensator, direct operated RE 29231/ Type ZDC

Servo solenoid valves with on-board electronics (OBE)

Proportional pressure reducing valve, pilot operated

3/2 directional spool valve, direct operated with solenoid actuation

Bourdon tube pressure switch with infinitely variable switching pressure differential

Proportional pressure reducing valve, in 3-way version

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRTE. Features.

Proportional directional valves, pilot operated, with electrical position feedback and integrated electronics (OBE)

Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6

Servo solenoid valves with positive overlap and on-board electronics (OBE)

Bourdon tube pressure switch with infinitely variable switching pressure differential

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRDE. Contents.

4-way directional servo valve Type 4WS.2E

Proportional directional valve, direct operated, with pq functionality

Differential pressure control, electrically adjustable

2-way flow control valve

Proportional pressure relief valve Types DBE(M) and DBE(M)E

Directional spool and seat valves with electrical actuation and M12x1 plug-in connection

4/3-way servo solenoid directional control valves, pilot operated, with electrical position feedback and on-board electronics

4/3-way servo solenoid directional control valves, pilot operated, with electrical position feedback and on-board electronics

2/2 directional seat valve, direct operated with solenoid actuation

Pressure reducing valve, pilot-operated. Type Z3DR. Contents. Features. RE Edition:

4/3 directional servo-valve with mechanical position feedback

Pressure reducing valve, pilot operated

4/2- and 4/3-way proportional directional valves, direct operated, without electrical position feedback, without/with integrated electronics (OBE)

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 05.11

Electro-Proportional Pressure Reducing and Relieving Cartridge Valves

4/3-way high response directional control valve pilot operated with electrical feedback and integrated electronics (OBE)

Pressure reducing valve, direct operated, with pressure monitoring

Closed-loop pressure and flow control system

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

Pressure relief valve, direct operated. Type ZDBY D, Z2DBY D. Features. Contents. RE Edition: Replaces: 01.09

Manifolds. Type HSR 10. Features. Contents. RE Edition: Replaces: 05.13

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

Pressure relief valve, pilot operated

Pressure relief valve, pilot operated

Sytronix Solutions with IndraDrive on Press Brakes. Technical Information. Contents. RE Edition:

Pressure relief valve, pilot operated

Pressure relief valve, directly operated

2-way flow control valve. Type 2FRM, 2FRH, 2FRW. Contents. Features. RE Edition: Replaces: 07.04

Check valve, pilot operated

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 10.05

Double throttle check valve Type Z2FS 10

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

Check valve. Type S. Contents. Features. RE Edition: Replaces:

Transcription:

Electric amplifiers for proportional valves RE 30109/07.05 1/6 Type VT-VSPA1 Unit series 1X List of contents Contents Page Features 1 Ordering data 2 Preferred types 2 Front panel 3 Circuit diagram 4 Technical data 5 Unit dimensions 6 Features Analog amplifier in Europe card format for installation in 19 subrack Differential input for setpoint voltage 0...+10 V Ramp generator with separate adjustment for up and down Zero potentiometer Closed-loop-controlled output stage LED display: Voltage supply On standby Ramp Off Solenoid current I M = 0 Testing and service equipment Test box type VT-PE-TB1, see RE 30063 Test adapter type VT-PA-3, see RE 30070

2/6 Bosch Rexroth AG Hydraulics VT-VSPA1 RE 30109/07.05 Ordering data VT V S P A 1 1X V0 RTP Hydraulic component For valves without electrical feedback = S RTP = Optional extras Ramp adjustment via potentiometer Valve type Proportional valve = P V0 = Customer version Catalog version Actuation Analog = A Unit series 1X = Unit series 10 to 19 Output stages 1 output stage = 1 Serial numbers for types 508 = 0.8 A solenoid 525 = 2.5 A solenoid Preferred types Type Material Number For valve types VT VSPA1 525 10/V0/RTP 0 811 405 079 see valve group A VT VSPA1 508 10/V0/RTP 0 811 405 081 see valve group B Valve group A DBETX... 25 DBE6X... 25 DRE6X... 25 DBE10Z... 25 DRE10Z... 25 2FREX6 2FREX10 3FREX6 3FREX10 4WRBA..EA Valve group B DBETX... 8 DBE6X... 8 DRE6X... 8 DBE10Z... 8 DRE10Z... 8

RE 30109/07.05 VT-VSPA1 Hydraulics Bosch Rexroth AG 3/6 Front panel

4/6 Bosch Rexroth AG Hydraulics VT-VSPA1 RE 30109/07.05 Circuit diagram with pin assignment

RE 30109/07.05 VT-VSPA1 Hydraulics Bosch Rexroth AG 5/6 Technical data Specifications P.C.B. format mm (100 x 160 x approx. 35)/(W x L x H) Europe card format with front panel with 7 modular spacings Plug connector Plug DIN 41612 F32 Ambient temperature C 0...+70, storage temperature min. 20; max. +70 Power supply 24 V DC nominal battery voltage 21...40 V, rectified AC voltage U eff = 21...28 V (single-phase, full-wave rectification) Current rating 0811 405079 max. 1.5 A (NG6)/max. 2.5 A (NG10) 0811 405081 max. 1.25 A Power consumption 0811 405079 max. 35 VA (NG6)/max. 60 VA (NG10) 0811 405081 max. 30 VA Setpoint potentiometer R L 1 kω Supply: b/z 32, +10 V/20 ma Input signals b10: +10 V z10: +10 V z16: +10 V Differential z18: Diff. 0 V } input External ramp shut-off b20: 6...40 V= (nom. 10 V DC) Ramp monitor signal z20: 0...10 V Cable lengths and cross-sections Solenoid: < 20 m 1.5 mm 2 Solenoid: 20...50 m 2.5 mm 2 Special features Short-circuit-proof inputs and outputs Clocked output stage Rapid energizing for fast response times LED displays Yellow: ramp OFF Yellow: solenoid current I M = 0 Green: U B ON Red: U B < U B min Valve response time 50 ms with 100 % signal change Valve hysteresis % < 4 Ramp times s 0.05...5 Adjustment possibilities Valve zero, sensitivity, ramp times, dither amplitude Caution! Power zero b2 and control zero b12 must be jumpered. If removing power pack, < 1 m directly to DIN plug. If removing > 1 m route control zero separately to ground. Notes for calibrating the P.C.B.s Zero: A setpoint U E 300 mv is set as default for calibration. Sensitivity (max.): A setpoint U E = 10 V is set as default for calibration. Notes on the use of ramps Ramp UP (accelerate) and ramp DOWN (decelerate) are each set by a trimming potentiometer. Ramp ON, if b20 open. Ramp OFF, if b20 U > 6 V, e.g. 10 V from b22. Ramp OFF interrupts a ramp in progress. There is an abrupt transition to the final signal value.

6/6 Bosch Rexroth AG Hydraulics VT-VSPA1 RE 30109/07.05 Unit dimensions (nominal dimensions in mm) Plug to DIN 41612 F32 Amplitude Dither Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Telefon +49 (0) 93 52 / 18-0 Telefax +49 (0) 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgement and verification. It must be remembered that our products are subject to a natural process of wear and aging.

RE 30109/07.05 VT-VSPA1 Hydraulics Bosch Rexroth AG Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Telefon +49 (0) 93 52 / 18-0 Telefax +49 (0) 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgement and verification. It must be remembered that our products are subject to a natural process of wear and aging.

Bosch Rexroth AG Hydraulics VT-VSPA1 RE 30109/07.05 Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Telefon +49 (0) 93 52 / 18-0 Telefax +49 (0) 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgement and verification. It must be remembered that our products are subject to a natural process of wear and aging.