Data sheet chainflex CF885.PE

Similar documents
Data sheet chainflex CF886

Data sheet chainflex CF881

Data sheet chainflex CF886

Data sheet chainflex CF130.UL

Data sheet chainflex CF210.UL

Data sheet chainflex CF140.UL

Data sheet chainflex CF5

Data sheet chainflex CF240

Data sheet chainflex CF8821

Data sheet chainflex CF6

Data sheet chainflex CFSOFT1

Data sheet chainflex CF300.UL.D

Data sheet chainflex CF310.UL

Data sheet chainflex CF270.UL.D

Data sheet chainflex CF330.D

Data sheet chainflex CF340

Data sheet chainflex CF10

Data sheet chainflex CF9

14 HH EAC/CTP CE RoHS-II conform

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table)

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table)

Art.-Nr. CF220.UL.H1xx.XX.XX CF220.UL.H2xx.XX.XX

Data sheet chainflex CF113.D

CF270.UL.D.

Bus system Profibus Ethernet (CAT 5e / GigE / PoE) ASinterface Part. No. CF CF CF & CF mm

Art.-Nr. CF280.UL.H1xx.XX.XX.D CF280.UL.H2xx.XX.XX.D

CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems

Data sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant.

CFRIP - tear strip for faster stripping

Min. bending radius for fixed installation 7,5 x d 6,8 x d 4,0 x d 6,8 x d Torsion (at 1 m cable length) --- ±45 ±90 ±45

DNV-GL HH CE RoHS-II conform

CFBUS CFBUS.PVC.040 CFBUS.PUR.040 CFBUS.040 CF CAT5 CFBUS.041 CFBUS.044

CF11.LC / CF11.LC.D CF14.CAT5

chainflex cable Servo cables CF887 PVC 15 +5/ CF210.UL PVC 10 +5/ CF220.UL.H PVC 10 +5/

chainflex cable Servo cables Exclusive! chainflex guarantee guaranteed lifetime Selection table page 268 CF887 PVC 15 +5/

Cables up to CAT7.

Cables up to CAT7.

Cables up to CAT7.

us cables New! chainflex guarantee club Guaranteed lifetime Selection table page 154 CFBUS.PVC PVC 12,5-5/

Guarantee. Special cables

Special cables. Guarantee. Special cables

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications

Fibre optic cables. Guarantee. Fibre optic cables. Information about Fibre optic cables CFLK CFLG88 CFLG.LB.PUR CFLG.LB CFLG.G

chainflex cables with DNV-GL certification ndustry plastics for longer life

Chainflex cable. Bus cables. Exclusive! Chainflex guarantee guaranteed lifetime Selection table page 174. Information Chainflex Ethernet cables

chainflex cables with GERMANISCHER LLOYD certification ndustry plastics for longer life

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology

Technical Data Sheet Unshielded (YY) PVC Control Cable

Test-Order chainflex

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

Identification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR. Part-No

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities

Special cables. chainflex Typees. chainflex

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements

ÖLFLEX CLASSIC 110 H Info Benefits

INFORMATION. Hybrid cables. Description

H05 V-K PVC-Single Cores, fine wire stranded

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

Technical Data Sheet Shielded (CY) PVC Control Cable

ÖLFLEX CLASSIC 115 CY

ÖLFLEX CLASSIC 130 H - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL

ÖLFLEX CLASSIC 110 CY

Chemical resistance Accidental

chainflex type Fibre optic cables* Information fibre optic cables 154 CFLK** PUR 12,5-20/ CFLG.2H CFLG.LB*** TPE 5-40/

PRODUCT INFORMATION H07V-K

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY. industrieblick / Fotolia

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH

SPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia

USA: UL-listed (MTW), Canada: CSA (TEW), Europe: <HAR> H07V-K (depending on cross s.), tin-coated strands

Cables for Railway Technology

SAC-4P-M12MS/ 5,0-PUR SH

chainflex readycable Video-/vision-/bus technology (with camera reference list Page 280) FireWire Ready-made cable TPE 260

PRODUCT INFORMATION. UNITRONIC SPIRAL LiF2Y11Y. Info New: the unscreened spiral cables with small cross section High restoring forces PUR outer sheath

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free)

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332

(N)SSHÖU O/J, (N)SSHÖU 3E, (N)SSHÖU 3E + ST 0.6/1kV Cable

NICHIGOH S CABLE CONTENTS ROBOT CABLE CONTROL CABLE RO-FLEX RO-FLEX RCVV-S 9 VCT-F 11 VCTF 13 MVVS 15 DATA TRANSMISSION CABLE NFKVV-SB 18

PRODUCT INFORMATION. ÖLFLEX HEAT 180 SiF. Info Flexible fine-wire copper conductor

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5

PRODUCT INFORMATION. ÖLFLEX HEAT 180 SiF

N2XY IEC XLPE PVC 0.6/1kV Cable

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)

SAC-5P-3,0-PUR/M12FS SH

flame Retardant overall screened Instrumentation cables (Multicore)

PUR c-track cables For highest requirements

HIGH TEMPERATURE CABLES

SY PVC / BS EN Control Flexible Cable

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

Transcription:

1. Outer jacket: Pressure extruded PVC mixture 2. Core insulation: Mechanically high-quality PVC mixture 3. Conductor: Conductor consisting of bare copper wires For detailed overview please see design table Cable structure Conductor Conductor consisting of bare copper wires (according to DIN EN 60228). Core insulation Mechanically high-quality PVC mixture. Core identification Green-yellow Outer jacket Low-adhesion PVC mixture, adapted to suit the requirements in e-chains. Colour: Pastel orange (similar to RAL 2003) Printing: black 00000 m * igus chainflex M CF885.PE.--.--j ----k 600/1000V E310776 cяuus AWM Style 10107 VW-1 AWM I/II A/B 80 C 600V FT1 EAC/CTP CE RoHS-II conform www.igus.de +++ chainflex cable works +++ * Length printing: Not calibrated. Only intended as an orientation aid. j / k Cable identification according to Part No. (see technical table). Example:... chainflex... CF885.PE.25.01... 1G2.5... 600/1000V... 1 / 5

Dynamic information Bend radius e-chain linear minimum 15 x d flexible minimum 12 x d fixed minimum 8 x d Temperature e-chain linear +5 C up to +70 C flexible -5 C up to +70 C (following DIN EN 60811-504) fixed -15 C up to +70 C (following DIN EN 50305) v max. unsupported 3 m/s a max. 20 m/s² Travel distance Unsupported travel distances up to 10 m, Class 1 These values are based on specific applications or tests. They do not represent the limit of what is technically feasible. d service life according to guarantee conditions Double strokes 1 million 3 million 5 million Temperature, from/to [ C] R min. [factor x d] R min. [factor x d] R min. [factor x d] +5/+15 17.5 18.5 19.5 +15/+60 15 16 17 +60/+70 17.5 18.5 19.5 Minimum guaranteed service life of the cable under the specified conditions. The installation of the cable is recommended within the middle temperature range. Electrical information Nominal voltage 600/1000 V (following DIN VDE 0298-3) Testing voltage 4000 V (following DIN EN 50395) 2 / 5

Properties and approvals Flame retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1 Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 status 1992) UL/CSA Style 10107, 600 V, 80 C NFPA Following NFPA 79-2012, chapter 12.9 EAC Certificate No. RU C-DE.ME77.B.01561 (TR ZU) CTP Certificate No. C-DE.PB49.B.00450 (Fire protection) Lead-free Following 2011/65/EC (RoHS-II) CE Following 2014/35/EU Typical lab test setup for this cable series Test bend radius R approx. 75-225 mm Test travel S approx. 1-15 m Test duration minimum 2-4 million double strokes Test speed approx. 0.5-2 m / s Test acceleration approx. 0.5-1.5 m / s² 3 / 5

Typical application areas For flexing applications, Class 3 Especially for unsupported travels, Class 1 Without influence of oil, Class 1 No torsion, Class 1 Preferably indoor applications Wood/stone processing, Packaging industry, supply systems, Handling, adjusting equipment 4 / 5

Technical tables: Mechanical information Part No. Number of cores and conductor nominal cross section Outer diameter (d) max. Copper index Weight [mm²] [mm] [kg/km] [kg/km] CF885.PE.25.01 1G2.5 6.5 24 55 CF885.PE.40.01 1G4.0 7.0 39 75 CF885.PE.60.01 1G6.0 8.0 58 97 CF885.PE.100.01 1G10.0 9.5 96 147 CF885.PE.160.01 1G16.0 10.5 154 228 CF885.PE.250.01 1G25.0 12.0 240 328 Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core Electrical information Conductor nominal cross section Maximum conductor resistance at 20 C (following DIN EN 50289-1-2) [mm²] [Ω/km] [A] 2.5 7.98 26 4 4.95 34 6 3.3 44 10 1.91 61 16 1.21 82 25 0.78 108 Maximum current rating at 30 C (following DIN VDE 0298-4) The final maximum current rating depends among other things on the ambient conditions, the type of the installation and the number of loaded cores. 5 / 5