Data sheet chainflex CF886

Similar documents
Data sheet chainflex CF881

Data sheet chainflex CF885.PE

Data sheet chainflex CF886

Data sheet chainflex CF210.UL

Data sheet chainflex CF240

Data sheet chainflex CF140.UL

Data sheet chainflex CF8821

Data sheet chainflex CF6

Data sheet chainflex CF130.UL

Data sheet chainflex CF5

Data sheet chainflex CF270.UL.D

Data sheet chainflex CF310.UL

Data sheet chainflex CFSOFT1

Data sheet chainflex CF300.UL.D

Data sheet chainflex CF340

Data sheet chainflex CF10

Data sheet chainflex CF330.D

14 HH EAC/CTP CE RoHS-II conform

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table)

CF270.UL.D.

Art.-Nr. CF220.UL.H1xx.XX.XX CF220.UL.H2xx.XX.XX

Data sheet chainflex CF113.D

Bus system Profibus Ethernet (CAT 5e / GigE / PoE) ASinterface Part. No. CF CF CF & CF mm

Data sheet chainflex CF9

Art.-Nr. CF280.UL.H1xx.XX.XX.D CF280.UL.H2xx.XX.XX.D

CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table)

Data sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant.

CFBUS CFBUS.PVC.040 CFBUS.PUR.040 CFBUS.040 CF CAT5 CFBUS.041 CFBUS.044

Min. bending radius for fixed installation 7,5 x d 6,8 x d 4,0 x d 6,8 x d Torsion (at 1 m cable length) --- ±45 ±90 ±45

DNV-GL HH CE RoHS-II conform

CFRIP - tear strip for faster stripping

CF11.LC / CF11.LC.D CF14.CAT5

chainflex cable Servo cables CF887 PVC 15 +5/ CF210.UL PVC 10 +5/ CF220.UL.H PVC 10 +5/

chainflex cable Servo cables Exclusive! chainflex guarantee guaranteed lifetime Selection table page 268 CF887 PVC 15 +5/

Cables up to CAT7.

Cables up to CAT7.

Cables up to CAT7.

us cables New! chainflex guarantee club Guaranteed lifetime Selection table page 154 CFBUS.PVC PVC 12,5-5/

Guarantee. Special cables

Special cables. Guarantee. Special cables

Chainflex cable. Bus cables. Exclusive! Chainflex guarantee guaranteed lifetime Selection table page 174. Information Chainflex Ethernet cables

chainflex cables with DNV-GL certification ndustry plastics for longer life

Fibre optic cables. Guarantee. Fibre optic cables. Information about Fibre optic cables CFLK CFLG88 CFLG.LB.PUR CFLG.LB CFLG.G

Identification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR. Part-No

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology

chainflex cables with GERMANISCHER LLOYD certification ndustry plastics for longer life

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements

Special cables. chainflex Typees. chainflex

Test-Order chainflex

Technical Data Sheet Shielded (CY) PVC Control Cable

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities

Technical Data Sheet Unshielded (YY) PVC Control Cable

INFORMATION. Hybrid cables. Description

ÖLFLEX CLASSIC 115 CY

Technical Data Sheet Unshielded (YY) PVC Control Cable

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL

ÖLFLEX CLASSIC 110 CY

H05 V-K PVC-Single Cores, fine wire stranded

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

ÖLFLEX CLASSIC 110 H Info Benefits

chainflex type Fibre optic cables* Information fibre optic cables 154 CFLK** PUR 12,5-20/ CFLG.2H CFLG.LB*** TPE 5-40/

SAC-4P-M12MS/ 5,0-PUR SH

chainflex readycable Video-/vision-/bus technology (with camera reference list Page 280) FireWire Ready-made cable TPE 260

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY. industrieblick / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free)

PVC motor cables unshielded

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

Cables for Railway Technology

ÖLFLEX CLASSIC 130 H - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH

CABLED TWISTED PAIRS CONDUCTORS

CABLED SINGLE CONDUCTORS

Chemical resistance Accidental

Data sheet. Connection line M12 4-pole D-coded 1.0 m. Illustrations P/N 142M1D11010 EAN Product specification. Page 1/

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5

PRODUCT INFORMATION H07V-K

SY PVC / BS EN Control Flexible Cable

Data sheet Connection line M12-RJ45 4-pole D-coded AWG m

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

(N)SSHÖU O/J, (N)SSHÖU 3E, (N)SSHÖU 3E + ST 0.6/1kV Cable

SAC-5P-3,0-PUR/M12FS SH

PUR c-track cables For highest requirements

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

USA: UL-listed (MTW), Canada: CSA (TEW), Europe: <HAR> H07V-K (depending on cross s.), tin-coated strands

Data sheet Connection line M12-RJ45 4-pole D-coded AWG m

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

NICHIGOH S CABLE CONTENTS ROBOT CABLE CONTROL CABLE RO-FLEX RO-FLEX RCVV-S 9 VCT-F 11 VCTF 13 MVVS 15 DATA TRANSMISSION CABLE NFKVV-SB 18

RFOU 0.6/1kV Power Cable

Cable Assemblies according to Bosch Rexroth Standard

HIGH TEMPERATURE CABLES

Transcription:

1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Banding: Plastic foil 4. Core insulation: Mechanically high-quality PVC mixture 5. Conductor: Conductor consisting of bare copper wires For detailed overview please see design table Cable structure Conductor Conductor consisting of bare copper wires (according to DIN EN 60228). Core insulation Mechanically high-quality PVC mixture. Overall shield Braiding made of tinned copper wires. Coverage approx. 60 % optical Outer jacket Low-adhesion PVC mixture, adapted to suit the requirements in e-chains. Colour: Pastel orange (similar to RAL 2003) Printing: black 00000 m * igus chainflex M CF886.--.--j ----k 600/1000V E310776 cяuus AWM Style 10107 VW-1 AWM I/II A/B 80 C 600V FT1 EAC/CTP CE RoHS-II conform www.igus.de +++ chainflex cable works +++ * Length printing: Not calibrated. Only intended as an orientation aid. j / k Cable identification according to Part No. (see technical table). Example:... chainflex... CF886.15.04... (4G1.5)C... 600/1000V... 1 / 5

Dynamic information Bend radius e-chain linear minimum 15 x d flexible minimum 12 x d fixed minimum 8 x d Temperature e-chain linear +5 C up to +70 C flexible -5 C up to +70 C (following DIN EN 60811-504) fixed -15 C up to +70 C (following DIN EN 50305) v max. unsupported 3 m/s a max. 20 m/s² Travel distance Unsupported travel distances up to 10 m, Class 1 These values are based on specific applications or tests. They do not represent the limit of what is technically feasible. d service life according to guarantee conditions Double strokes 1 million 3 million 5 million Temperature, from/to [ C] R min. [factor x d] R min. [factor x d] R min. [factor x d] +5/+15 17.5 18.5 19.5 +15/+60 15 16 17 +60/+70 17.5 18.5 19.5 Minimum guaranteed service life of the cable under the specified conditions. The installation of the cable is recommended within the middle temperature range. Electrical information Nominal voltage 600/1000 V (following DIN VDE 0298-3) Testing voltage 4000 V (following DIN EN 50395) 2 / 5

Properties and approvals Flame retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1 Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 status 1992) UL/CSA Style 10107, 600 V, 80 C NFPA Following NFPA 79-2012, chapter 12.9 EAC Certificate No. RU C-DE.ME77.B.01561 (TR ZU) CTP Certificate No. C-DE.PB49.B.00450 (Fire protection) Lead-free Following 2011/65/EC (RoHS-II) CE Following 2014/35/EU Typical lab test setup for this cable series Test bend radius R approx. 75-225 mm Test travel S approx. 1-15 m Test duration minimum 2-4 million double strokes Test speed approx. 0.5-2 m / s Test acceleration approx. 0.5-1.5 m / s² 3 / 5

Typical application areas For flexing applications, Class 3 Especially for unsupported travels, Class 1 Without influence of oil, Class 1 No torsion, Class 1 Preferably indoor applications Wood/stone processing, Packaging industry, supply systems, Handling, adjusting equipment 4 / 5

Technical tables: Mechanical information Part No. Number of cores and conductor nominal cross section Outer diameter (d) max. Copper index Weight [mm²] [mm] [kg/km] [kg/km] CF886.160.01 11) (1x16)C 11.5 180 256 CF886.250.01 11) (1x25)C 13.0 271 361 CF886.350.01 11) (1x35)C 15.5 382 521 CF886.500.01 11) (1x50)C 17.5 535 692 CF886.700.01 11) (1x70)C 19.5 737 917 CF886.950.01 11) (1x95)C 21.0 977 1159 11) Phase-out model Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core Electrical information Conductor nominal cross section Maximum conductor resistance at 20 C (following DIN EN 50289-1-2) [mm²] [Ω/km] [A] 16 1.21 82 25 0.78 108 35 0.56 135 50 0.39 168 70 0.28 207 95 0.21 250 Maximum current rating at 30 C (following DIN VDE 0298-4) The final maximum current rating depends among other things on the ambient conditions, the type of the installation and the number of loaded cores. 5 / 5