DL1 Electrode Mountings (Durafet II ph Electrodes & Mountings for DL421 with and without Vario Pin Durafet Connectors) Pipeline Electrode Mounting (7758 Type) ph ORP Insertion Removal (7774 Type) Sanitary Mounting Tee not included 7777 Immersion Mounting 7777 Inline Mounting A dot ( ) denotes availability. Key Number I II III _ - _ - - Selection Availability Key Number - Mounting/Electrode Only - (Note 1) (Specify DL421 separately) U.S.$ ph Electrode/Mountings Electrode/Mountings for Durafet II ph version of DL421 DL1 TABLE I - INSTALLATION MOUNTING TYPE (Note 2) Insertion/Removal (7774) Ball Valve Assembly Material CPVC 741 1111 (Remote DL421 Mtg. Only) of Construction 316SS 742 1738 In-Line (7777) 1 in. (2,54 cm) Electrode Suitable Remote DL421 Mtg w/pwb connector 771 for 3/4" Pipe Tee Integral DL421 Mounting 772 Remote DL421 Mtg w/variopin connector 774 424 Immersion (7777) 1 in. (2,54 cm) Electrode Suitable Remote DL421 Mtg w/pwb connector 773 for Immersion Applications Remote DL421 Mtg w/variopin connector 775 424 1.5 in. (3,81cm) flange - 2.29 in. (5,82cm) immersion 941 Sanitary Durafet Shallow Insertion 2 in. (5,8 cm) flange - 2.83 in. (7,19 cm) immersion 942 Vario Pin Connector 3 in. (7,62 cm) flange - 2.53 in. (6,43 cm) immersion 943 (Remote DL421 Mtg Only ) 1.5 in. (3,81cm) flange - 2.91 in. (7,39cm) immersion 944 Deep Insertion 2 in. (5,8 cm) flange - 3.72 in. (9,45 cm) immersion 945 3 in. (7,62 cm) flange - 3.73 in. (9,47 cm) immersion 946 По вопросам продаж и поддержки обращайтесь: Астана +7(7172)727-132, Волгоград (844)278-3-48, Воронеж (473)24-51-73, Екатеринбург (343)384-55-89, Казань (843)26-1-48, Краснодар (861)23-4-9, Красноярск (391)24-63-61, Москва (495)268-4-7, Нижний Новгород (831)429-8-12, Новосибирск (383)227-86-73, Ростов-на-Дону (863)38-18-15, Самара (846)26-3-16, Санкт-Петербург (812)39-46-4, Саратов (845)249-38-78, Уфа (347)229-48-12 Единый адрес: hwn@nt-rt.ru www.honeywell.nt-rt.ru
TABLE II - OPTIONS Selection Availability U.S.$ Tagging None Linen Customer I.D. Tag - 3 lines, 22 characters per line LT 2 Stainless Steel Customer I.D. Tag - 3 lines, 22 characters per line SS 35 Calibration Certificate None Calibration & Conformance Certificate to be supplied w/shipment CC 55 TABLE III - FACTORY USE Factory Use Only Notes: 1. DL421 electronics module must be specified separately 2. Replacement electrodes for these mountings can be ordered as follows: 3. Users of the old card edge style Sanitary Durafet connector must upgrade their remote cable. Replacement Electrode Table I Selection Mounting Type Part Number 741 Insertion Removal - CPVC (7774) 5125554-52 742 Insertion Removal - 316 SS (7774) 5124976-51 771 In-Line Remote DL421 (7777) w/pwb connector 5125554-51 772 In-Line Integral DL421 (7777) w/pwb connector 515258-51 773 Immersion/ Remote DL421 (7777) w/pwb connector 5125554-52 774 In-Line Remote (7777) w/vario Pin connector 5145353-51 775 Immersion/ Remote (7777) w/vario Pin Connetor 5145353-55 941 1.5 in. (3,81 cm) flange, Shallow Immersion w/pwb connector 51453535-51 942 2 in. (5,8 cm) flange, Shallow Immersion w/pwb connector 51453535-53 943 3 in. (7,62 cm) flange, Shallow Immersion w/pwb connector 51453535-55 944 1.5 in. (3,81 cm) flange, Deep Immersion w/pwb connector 51453535-52 945 2 in. (5,8 cm) flange, Deep Immersion w/pwb connector 51453535-54 946 3 in. (7,62 cm) flange, Deep Immersion w/pwb connector 51453535-56
Low Cost DirectLine ph DL2 Electrode Mountings For Use With DL421 Modules 51-52-16-76 Issue 13 Combines measuring and reference electrodes, together with integral fast responding automatic temperature compensator Temperature range - 65 C (32-149 F) Pressure Spec - 7 psig Suitable for in-line and immersion applications See Product Spec 7-82-3-59 for detail specifications A dot ( ) denotes availability. No ( ) dot denotes not available. Key Number I II _ - _ - Key Number - Mounting/Electrode Only 1 (Specify DL421 separately) ph Electrode/Mountings Electrode/Mountings for Glass ph version of DL421 Selection Availability U.S.$ DL2 TABLE I - Mounting Type, Construction, Cable Length Mounting Type Construction Cable Length In-Line or Immersion Remote Mounting 2 2 feet SX1 21 TABLE II - Factory Use Future Use Future Use 1. DL421 electronics module must be specified separately 2. ph electrodes are supplied with a integral 6,1m (2 ft.) sensor cable which must be wired to the DL421 remote connector (ordered with DL421 Sensor Module).
DL3 Electrode Mountings for Meredian II ORP Electrodes with DL422 51-52-16-77 Issue 14 In-line Mounting (7777 Type) Immersion Mounting (7777 Type) Combines measuring and reference electrodes, Temperature range - 1 C (32-212 F) Suitable for in-line and immersion applications May be mounted in any position Mounting is FM approved, Intrinsically Safe for Class I, Group A, B, C, D areas when used with APT2 Transmitter See Product Spec 7-82-3-6 for detail A dot ( ) denotes availability. No ( ) dot denotes not available. Key Number I II III _ - _ - - Key Number - Mounting/Electrode Only 1 (Specify DL422 separately) Selection Availability U.S.$ ph Electrode/ Electrode/Mountings for Meredian II ORP version DL3 Mountings of DL422 TABLE I - Mounting Type, Construction, Electrode Material, Cable Length 2 Mounting Type Construction Electrode Cable Material Length In-Line Integral Mounting Platinum None 77 436 (7777) Remote Mounting Platinum 2 feet 774 52 Gold 2 feet 775 541 Immersion Remote Mounting Platinum 2 feet 778 52 (7777) Gold 2 feet 779 541 TABLE II - OPTIONS None Tagging Linen Customer I.D. Tag - 3 lines w/22 characters/line Stainless Steel Customer I.D. Tag - 3 lines w/22 characters/line Calibration None Certificate Calibration certificate to be supplied w/shipment LT 2 SS 35 CC 55 TABLE III- FACTORY USE Factory Use Only
Section 2 Page: DL-8 Effective Date: Januray 1, 213 1. DL422 electronics module must be specified separately 2. Replacement electrodes for these mountings can be ordered as follows: Table I Selection Mounting Type Material Replacement Electrode P/N 77 In-Line Integral Mounting (7777) Platinum 515659-52 774 In-Line Remote Mounting (7777) Platinum 5145134-54 775 In-Line Remote Mounting (7777) Gold 51451341-54 778 Immersion Remote Mounting (7777) Platinum 5145134-53 779 Immersion Remote Mounting (7777) Gold 51451341-53 По вопросам продаж и поддержки обращайтесь: Астана +7(7172)727-132, Волгоград (844)278-3-48, Воронеж (473)24-51-73, Екатеринбург (343)384-55-89, Казань (843)26-1-48, Краснодар (861)23-4-9, Красноярск (391)24-63-61, Москва (495)268-4-7, Нижний Новгород (831)429-8-12, Новосибирск (383)227-86-73, Ростов-на-Дону (863)38-18-15, Самара (846)26-3-16, Санкт-Петербург (812)39-46-4, Саратов (845)249-38-78, Уфа (347)229-48-12 Единый адрес: hwn@nt-rt.ru www.honeywell.nt-rt.ru