with Vacuum Circuit Breaker HAF

Similar documents
with Vacuum Circuit Breaker HAF

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

Metal-Clad Switchgear

Medium Voltage. ANSI C37.20 and NEMA SG-5

Ensuring excellent switching capability and high quality with various advantages

We build a better future!

HYUNDAI U-Series. Molded Case Circuit Breaker

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Contents. We build a better future! MCC HCB

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

Gas Insulated Switchgear

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

UniGear. Technical Guide

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

MESG 12 / 17.5 / 24 / 36 KV

NXPLUS C Single busbar. Maintenance-free for lifetime

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Benefits, typical uses

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

ATR-MIX. METAL ENCLOSED SWITCHGEAR kV A ka

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

Metal Clad Switchgears

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

DIRECT CONTACT. Switchgear Sales Team TEL : ~9 CHANGWON PLANT Switchgear Design Team TEL : ~9

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

PIX-H Metal-clad switchgear up to 17.5kV

Gas Insulated Metal-clad Switchgear, HMGS!

Extensible Unit - VCE2a

Air-insulated switchgear UniGear type ZS1

Metal Clad Air Insulated Switchgear

Power Systems PU. HYOSUNG Standard High-voltage Switchgear ProSWGR. Medium Voltage Metal-clad Switchgear

10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36

33KV INDOOR SWITCHGEAR

Power IT Air Insulated Cubicle Uniswitch

8DJ. Maintenance-free for lifetime

the safe, reliable, and efficient choice for MV switchgear

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

UniSafe 36. Medium voltage, arc-proof, air-insulated, metal-clad switchboard

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)

COMPACT SUBSTATION GUIDE

Total Solution. for Electrical Industry

HYUNDAI INVERTER Powerful Operation & High Performance

MEDIUM VOLTAGE SWITCHGEAR. DW-2, Primary switchgear, air insulated and metal clad.


CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

PC3.0/MNS R 690 V A Main low voltage distribution switchgear

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

Modular medium-voltage switchgear. NorMax

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

OVERVIEW DESCRIPTION AND CHARACTERISTICS APPARATUS AND TYPES AVAILABLE SWITCHGEAR CHARACTERISTICS INSTRUMENT TRANSFORMERS MEASUREMENT SENSORS

Valid for you. medium voltage switchgear

UP TO 17,5 kv LSC 2B PM (METAL-CLAD) WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

e 2 ALPHA Medium Voltage Switchgear K Catalogue EN

TECHNICAL SPECIFICATION. UP TO 36 kv METAL-CLAD. With WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Reliable medium-voltage switchgear for fail-safe operation, up to 24 kv siemens.com/simoprime-partner

Metal Clad VCBs ~ Mk1

CONTENT. EPE METALCLAD SWITCHGEARS AMS SERIES 12kV AMS METALCLAD SWITCHGEAR 24kV AMS METALCLAD SWITCHGEAR 40.5KV AMS METALCLAD SWITCHGEAR

MNS Light F. Low-voltage switchgear with fixed units. ABB LV Systems

CP Automatic capacitor bank

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Air-insulated medium voltage switchgear metal-enclosed type-tested factory-assembled withdrawable-unit design 12 kv / 24 kv

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear

Air Insulated Switchgear NXAirS, 40.5kV Answers for infrastructure and cities.

Key features. DESIGNS: - Conservator type - Hermetically sealed

CM5-03. Medium voltage air insulated arc proof metal clad Switchgears MINIVER/C

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

AIR INsULATeD switchgear >> PIX. up to 24 kv. Air-insulated switchgear with vacuum circuit-breaker. system configuration.

Gas Insulated Switchgear

Power/Vac OEM Express Switchgear

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

Unitole UP kv Primary substations Motor control centres

10-750kW / DOOSAN Engine Mounted Control Panel kW / MTU Engine Floor-Standing Control Panel

MCSG 12kV / A

MEDIUM VOLTAGE SWITCHGEAR

CPG.0 Single busbar gas-insulated cubicles

Powered by Safety Powell GIS Type G81 Switchgear

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Gas Insulated Switchgear

Content. Uniswitch. 1. Design philosophy Applications Switchgear construction Cubicle types... 9

Transcription:

M E T A L - C L A D S W I T C H G E A R Safety and Reliability with Vacuum Circuit Breaker HAF Flexible Design and Compact with Vacuum Circuit Breaker HVF Easy Installation and Maintenance

We build a better future! Hyundai medium voltage metal-clad switchgears models HMS-106 and HMS-108 with a drawable circuit breaker trucks are single-tier, factory-assembled and suitable for a rated voltage of 7.2kV to 24kV. The switchgears have been type tested in accordance with applicable IEC standards. C O N T E N T S General HMS-106 Construction Dimension HMS-108 Construction Dimension 03 06 08 11 13

HMS Medium Voltage Metal-clad Switchgear Design Concepts Applicable Standards HMS switchgears have been designed and manufactured in cooperation with our quality assurance program ensuring; - Maximum safety and reliability - A minimum of maintenance, with all parts easily accessible - A simple but flexible design - Easy installation HMS switchgears comply with the following international standards. - IEC 298 and 694 - BS 5227 - JEM 1425 Description of Protection Degree Degree Description of Protection IP2X Protection against entry to hazardous parts for a finger or other solid foreign objects of diameter greater than 12mm. No protection against water. IP4X Protection against entry to hazardous parts for wires of a diameter or strips of a thickness greater than 1.0mm. No protection against water. Recommended for power plants, offshore plants, substations and industrial plants. IP41 Same as IP4X, but vertically falling drop protection is added. IP51 Same as IP41, but dust protection is added. (The ingress of dust is not totally prevented, but dust shall not penetrate in a quantity sufficient to interfere with satisfactory operation) Recommended for coal mine plants. Degree of Protection Degree of protection for standard switchgears are as follows. The other degrees (IP41, IP51, etc.) are also available on request. - Degree of protection for the switchgear enclosure : IP4X - Degree of protection for the internal partition : IP2X 04 05

HMS Medium Voltage Metal-clad Switchgear Operating Conditions Enclosure Hyundai s switchgears are intended for use under the normal indoor operating conditions and special operating conditions. Normal indoor operating conditions - Ambient temperatures : 35 maximum for 24 hour average. 40 maximum value. - The altitude is not to exceed 1000M sea level. - Relative humidity : 95% maximum over a 24 hour average. 90% maximum one month average. The rigid outer enclosure of the switchgear consists of steel sheets with folded edges bolted together. The CNC machine and FMS(Flexible Manufacturing System) make extremely accurate dimensions possible, providing the best quality and savings in installation costs. The standard thicknesses of steel plates are as follows: Frame 2.3mm Front door 3.2mm Rear door(or plate) 2.3mm Bottom plate 2.3mm ~ 3.2mm Special operating conditions Others 1.6mm and above The following conditions are considered special operating conditions. - Different values from those specified in the normal indoor operating conditions. - Outdoor operation. - Heavy vibrations or shocks. - A hazardous area. - Seismic requirements for nuclear power plants. Name Plate Material : Laminated plastic, 2.0t (White background) Fixing Method : PVC locker(sealer) Routine Testing Finish The switchgear enclosure is cleaned, rust-proofed and painted through Hyundai's standard electrostatic powder coating procedure. The average thickness of the painted finish is 50 microns. Standard finish colours are Munsell no. 5Y7/1 and RAL7032 (Both are a light gray). Routine tests are conducted on each unit at Hyundai s factory to ensure that switchgears meet their specitications. - A power-frequency voltage test on the main circuit - A power-frequency voltage test on the auxiliary and control circuits - Resistance measurement for the main circuit - A mechanical operations test - A test of auxiliary electrical devices - Verification of correct wiring

HMS-106 HMS MEDIUM VOLTAGE METAL-CLAD SWITCHGEAR B A C A Circuit-breaker Compartment 1. Withdrawable breaker truck with 3AF circuit-breaker 2. Plug and socket for auxiliary circuit 3. Contact bushing 4. Metal shutter 5. Dummy stand D Construction The HMS-106 switchgear is divided into compartments by means of earthed metal partitions. - Circuit-breaker compartment - Low voltage compartment - Bus-bar compartment - Cable connection compartment Cable-connection Compartment The cable-connection compartment is accessible from a hinged rear door. (A bolted, removable cover plate is also available on request) Sufficient space is provided for the termination of power cables; as many as six cables per phase can be connected. B Low Voltage Compartment 6. Mounting plate for auxiliary devices C Bus-bar Compartment 7. Main bus-bar 8. Partition bushing 9. Fixed disconnecting contact Epoxy resin-insulated 3 voltage transformers(v.t.), mounted on withdrawable trucks, with high rupturing capacity fuses can be located in the upper/rear part of the compartment. An extension guide rail is provided for the maintenance of V.T. with the truck half-drawn out but still in the panel. D Cable Connection Compartment 10. Block-type current transformer 11. Withdrawable truck with voltage transformer 12. Shutter 13. Earthing switch 14. Shaft for earthing switch 15. Branch bus-bar 16. Epoxy insulator 17. Cable clamper 3 block-type current transformers (C.T.) can be mounted per panel, however, bushing-type C.T.s can be added to the line and load sides of the contact bushing. Zero phase current transformers and surge arresters are also located in the compartment. The earthing switch operated from the front of the panel has making capacity that can be switched onto live parts. The position indicator is provided at the front of the panel. 06 07

HMS-106 with Vacuum Circuit Breaker HAF Circuit-breaker Compartment Low Voltage(LV) Compartment The HMS-106 switchgear contains a withdrawable breaker truck incorporating a vacuum circuit breaker HAF. The LV compartment with a front-hinged door accommodates relays, measuring instruments, switches, terminal blocks, indicating lights, etc. The following locks are provided to ensure proper operation and personnel safety. - The withdrawal or engagement of a circuit breaker is impossible unless it is in the open position. - The operation of a circuit breaker is impossible unless it is in the service or test/disconnected positions. - Uncoupling the plug on an auxiliary circuit is impossible when the breaker truck is in the service position. - The operation of the earthing switch is impossible unless the associated breaker truck is in the test/disconnected position or removed from the panel. (A keyed lock is provided to ensure safe operation). Standard control wiring in the LV compartment is 2.0mm, 600V graded pvc insulated wire. PVC ducts make the wiring easy and simple. Interconnections between panels can be made through the openings on the side plates. The opening is shrouded with grommet to protect the wiring from damage. Each wire is identified by the wire number on the white vinyl tube at its end. A ring-type lug is provided for wiring. Bus-bar Compartment The track-resistant, flame-retardant polyester insulated contact bushing completely prevents the propagation of faults from the C.B. compartment to the bus-bar compartment and vice versa. The metal shutters, lockable in the closed position, automatically shield off the fixed disconnecting contacts when the breaker truck is drawn-out. Bus-bars braced with partition bushings (polyester) run through the bottom of the panel. No moving parts enter in the bus-bar compartment, making the bus-bar invulnerable. The bus-bar system has high dynamic and dielectric strength and can dissipate heat. The earthing bar is provided at the bottom of the compartment for earthing the breaker truck between the test/disconnected and the service positions. The 24 pin plugs and sockets on an auxiliary circuit remain connected in the test/disconnected position so that the circuit breaker can be tested. In a 15kV switchgear, a mechanically and electrically outfitted insulating bus-bar system is provided. The removable insulation cover (boot) is placed over the joints and secured in place. In 7.2 and 12kV switchgears, a bared bus-bar system is standard. Circuit-breaker Removed Circuit-breaker in the Service Position Cable-connection Compartment with Rear Door Open

HMS-106 HMS MEDIUM VOLTAGE METAL-CLAD SWITCHGEAR Special Tools and Accessories Special tools are supplied(standard) - A hand crank for breaker truck withdrawable - A manual charging handle for C.B.s - An operating handle for the earthing switch. - An extension guide rail for V.T. truck withdrawable - A trolly for the breaker truck Electrical Characteristic for HMS-106 Accessories - Auxiliary contacts for breaker trucks in the service position : 1No +1Nc supplied on request. - Auxiliary contact for breaker trucks in the test/disconnected position : 1No +1Nc supplied on request. - A heater(110v or 220V), if requested or for outdoor operation, will be supplied to the C.B. compartment. - A surge arrester - Zero phase current transformer Rated voltage (kv) Rated 1min power-frequency withstand voltage (kv rms) Impulse withstand voltage (kv peak) Rated current (A) (ka rms) Short-time withstand current for 1s (1) (ka peak) 7.2 20 60 1250, 2000 40 104 (2) 12 28 75 1250, 2000 40 104 (2) 15 36 95 1250, 2000 40 104 (2) (1) for duration > 1s, consult us (2) 100ka for 50Hz Cubicle Dimension for HMS-106 Rated voltage (kv) Rated current (A) Width (mm) Depth (mm) Height (mm) 7.2 1250, 2000 900 2000 2200 2300 12 1250, 2000 900 2000 2200 2300 15 1250, 2000 900 2000 2200 2300 08 09

HMS-106 with Vacuum Circuit Breaker HAF Outgoing Feeder Panel Bus Tie Panel Bus Riser Panel Recommended Anchoring Detail Side Frame Door HEX Bolt & Nut M12XL30 Base Frame 2nd Concrete Finishing Adjustment Plate for Level 1st Concrete Foundation Rail (: 100X50X7.5) not supplied by HHI

HMS-108 HMS MEDIUM VOLTAGE METAL-CLAD SWITCHGEAR B A D C A Circuit-breaker Compartment 1. Withdrawable breaker truck with HVF circuit-breaker 2. Plug and socket for auxiliary circuit 3. Screw for truck in and out 4. Guide for shutter operating mechanism 5. Metal shutter 6. Contact bushing B Low Voltage Compartment 7. Mounting plate for auxiliary devices C Bus-bar Compartment 8. Main bus-bar 9. Fixed disconnecting contact D Cable Connection Compartment 10. Block-type current transformer 11. Earthing switch 12. Shaft for earthing switch 13. Branch bus-bar 14. Epoxy insulator 15. Cable clamper LV Compartment 10 11

HMS-108 with Vacuum Circuit Breaker HVF Construction Circuit-breaker Compartment The HMS-108 switchgear is divided into compartments by means of earthed metal partitions. - Circuit-breaker compartment - Low voltage compartment - Bus-bar compartment - Cable connection compartment Cable-connection Compartment The cable-connection compartment is accessible from a hinged rear door.(a bolted, removable cover plate is also available on requet) Sufficient space is provided for the termination of power cables; as many as six cables per phase can be connected. For 7.2kV and 12kV switchgears, epoxy resin-insulated voltage transformers(v.t.) with high rupturing capacity fuses can be mounted on the upper/rear part of the compartment. 6 current transformers (2 per phase) can be mounted. Zero phase current transformers and surge arresters are also located in the compartment. The HMS-108 switchgear contains a withdrawable breaker truck incorporating a vacuum circuit breaker HVF, vacuum contactor(up to 12kV) and a SF 6 gas circuit-breaker can also be mounted on the truck by request. The following locks are provided to ensure proper operation and personnel safety. - The withdrawal or engagement of a circuit-breaker is impossible unless it is in the open position. - The operation of a circuit-breaker is impossible unless it is in the service or test/disconnected position. - Uncoupling the plug on an auxiliary circuit is impossible when the breaker truck is in the 'sevice' position. - The operation of the earthing switch is impossible unless the associated breaker truck is in the test/disconnected position or removed from the panel (A keyed lock is provided to ensure safe operation) The track-resistant, flame-retardant polyester insulated contact bushing completely prevents the propagation of faults from the C.B. compartment to the bus-bar compartment and vice versa. The metal shutters, lockable in the closed position, automatically shield off the fixed disconnecting contacts when the breaker truck is drawn-out. The earthing switch operated from the front of the panel has making capacity that can be switched onto live parts. The position indicator is provided at the front of the panel. The earthing bar is provided at the bottom of the compartment for earthing the breaker truck between the test/disconnected and the service positions. The ground bus located at the bottom runs the full range of panels. The 24 pin plugs and sockets on an auxiliary circuit remain connected in the test/disconnected position so that the circuit breaker can be tested.

HMS-108 HMS MEDIUM VOLTAGE METAL-CLAD SWITCHGEAR Low Voltage(LV) Compartment The LV compartment with a hinged door accommodates relays, measuring instruments, switches, terminal blocks indicating lights, etc. The control wiring in the LV compartment is 2.0mm 600V graded PVC insulated wire. PVC ducts make the wiring easy and simple. Interconnections between panels can be made through the openings on the side plates. The opening is shrouded with grommet to protect the wiring from damage. Each wire is identified by the wire number on the white vinyl tube at its end. A ring-type lug is provided for wiring. Circuit-breaker Removed Circuit-breaker in the Service Position Bus-bar Compartment Bus-bar Compartment Bus-bars supported by fixed disconnecting contacts run through the bottom of the panel. However, for 7.2kV and 12kV switchgears, partition bushings are also provided between adjacent panels to fortify the bus-bar against high dynamic stresses caused by high fault current. No moving parts enter in the bus-bar compartment, making the bus-bar invulnerable. The bus-bars are made of high-conductivity copper or copper-clad aluminium. Cable Connection Compartment In a 24kV switchgear, a mechanically and electrically outfitted insulating bus-bar system is provided. The removable insulation cover(boot) is placed over the joints and secured in place. In 7.2 and 12kV switchgears, a bared bus-bar system is standard. 12 13

HMS-108 with Vacuum Circuit Breaker HVF Electrical Characteristic for HMS-108 Rated voltage (kv) Rated 1min power-frequency withstand voltage (kv rms) Impulse withstand voltage (kv peak) Rated current (A) (ka rms) Short-time withstand current for 1s (1) (ka peak) 7.2 20 60 1250, 2000 40 104 (2) 12 28 75 1250, 2000 50 130 (3) 24 50 125 630, 1250 2000, 2500 25 65 (4) (1) for duration > 1s, consult us (2) 100ka for 50Hz (3) 125kA for 50Hz (4) 63kA for 50Hz Cubicle Dimension for HMS-108 Rated voltage (kv) Rated current (A) Width (mm) Depth (mm) Height (mm) 630, 1250 750 (1) 1600 7.2 2000 750 1600 2350 900 (2) 1800 630, 1250 750 (1) 1600 12 2000 750 1600 2350 900 (2) 1800 24 630, 1250 2000, 2500 800 1000 (3) 2000 2200 2350 (1) 650 for 25kA (2) 750 for Bus Riser Panel (3) 800 for Bus Riser Panel

HMS-108 HMS MEDIUM VOLTAGE METAL-CLAD SWITCHGEAR Special Tools and Accessories Special tools are supplied(standard) - A hand crank for breaker truck withdrawable - A manual charging handle for C.B.s - An operating handle for the earthing switch. - Alignments for breaker truck removal Accessories - Auxiliary contacts for breaker trucks in the service position : 1NO+1NC supplied on request. - Auxiliary contact for breaker trucks in the test/disconnected position : 1NO+1NC supplied on request - A heater(110v or 220V) by request will be supplied to the C.B. compartment - A surge arrester - Zero phase current transformer Typical Section Views Main Bus Located Bottom Side Main Bus Located Top Side Outgoing Feeder Panel Outgoing Feeder Panel 14 15

HMS-108 with Vacuum Circuit Breaker HVF Main Bus Located Bottom Side Main Bus Located Top Side Bus Tie Panel Bus Tie Panel Bus Riser Panel with Drawable V.T Truck Bus Riser Panel with Drawable V.T Truck

HHI-WC-SE-B04-02 2004.11 Designed by Design Korea www.hyundai-elec.com HEAD OFFICE 1. JEONHA-DONG, DONG-GU, ULSAN, KOREA TEL. 82-52-230-8101~12 FAX. 82-52-230-8100 SEOUL HYUNDAI B/D, 140-2, GYE-DONG, JONGNO-GU, SEOUL, KOREA (Sales & Marketing) TEL. 82-2-746-7579, 7524 FAX. 82-2-746-7648 / Domestic Sales TEL. 82-2-746-7613, 7622 FAX. 82-2-746-7647 ORLANDO 3452 LAKE LYNDA DRIVE, SUITE 110. ORLANDO, FLORIDA 32817 U.S.A. TEL. 1-407-249-7350 FAX.1-407-275-4940 LONDON 2ND FLOOR, THE TRIANGLE, 5-17 HAMMERSMITH GROVE LONDON, W6 0LG, UK TEL. 44-20-8600-7127 FAX.44-20-8741-5620, 4571 TOKYO 8TH FL., YURAKUCHO DENKI BLDG.1-7-1, YURAKU-CHO, CHIYODA-GU, TOKYO, JAPAN 100-0006 TEL. 81-3-3212-2076, 3215-7159 FAX. 81-3-3211-2093 CAIRO APARTMENT NO. 503, 5TH FL., BLDG. NO. 7 BLOCK 2, 9TH DIVISION, EL-NASR ROAD, NEW MAADI, CAIRO, EGYPT TEL. 20-2-520-0148~9 FAX. 20-2-754-7528 SOFIA 1271, SOFIA 41, ROJEN BLVD. BULGARIA TEL. 359-2-938-1068 FAX. 359-2-936-0742 YANGZHONG #109 EAST YANGZI ROAD, YANGZHONG CITY, JIANGSU, PROVINCE, CHINA. 212-200 JIANGSU HYUNDAI NANZI ELECTRIC CO.,LTD. TEL. 86-511-836-5576, 7166 FAX. 86-511-836-7596