POWER GENERATORS POWER GENERATORS AIRMAN KVA PRIME RATED PRECISION ENGINEERED JAPANESE RELIABILITY COMPLETE AIR & POWER SOLUTIONS

Similar documents
PORTABLE DIESEL AIR COMPRESSORS

AIRMAN COMPRESSORS. Portable Diesel Air Compressors Engineered for Australian Conditions. 1.6 m3/mm m3/mm 55 cfm cfm

Sound Proof Diesel Generator. Welders

Engine GENERATOR SDG series. Engine GENERATOR SDG series OUR PLANTS ARE CERTIFIED RECOGNIZED AS BEING WORTHY OF ISO 9001/14001 CERTIFICATION.

LIGHTING TOWERS PERTH SYDNEY MELBOURNE BRISBANE ADELAIDE NEWCASTLE DARWIN MACKAY KALGOORLIE

WhisperWatt Generators

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

CERTIFIED SPECIFICATIONS DGK25B LOW-NOISE DIESEL-POWERED AC GENERATOR. SHINDAIWA Corporation

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

Engine GENERATOR SDG series

Commercial Mobile Generators. Pocket Guide

LOW-NOISE DIESEL-POWERED AC GENERATOR

GENERATORS - PORTABLE

PowerSource Generators. Product Range

Expert Design...Trusted Power

WPS10S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

PRO Rental Product Range. PRO150-1 (Fuel Optimised) PRO150-2 (EUIIIa Compliant) KEY FEATURES. Alternator. Rental Ready Features

FAC Series PORTABLE COMPRESSORS

PowerBox C1000 D2R and C1250 D2R. Reliable, flexible power systems engineered to provide cost-effective power even in the most remote environments

WPS137S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

Developing Technology for Tomorrow's Power Needs. Building the Future. Welders for the European Market

G10 G570 PowerSource Mobile Generators

RENTAL DIESEL GENERATOR SET

Rental Power QSB7 series engine

GE.PK.022/020.SS+0_all

400 Series 404D-22TA Industrial Open Power Unit 46.2 kw / rpm

400 Series 404D-22 Industrial Open Power Unit 37 kw / rpm

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Mobile Generator MMG25FHI Specifications

Magnum Mobile Generator MMG75 SS Specifications

GE.VO.360/325.SS+0_all

Industrial Diesel Generator Set KD1650-E 50 Hz - Emission Optimized EPA Tier 2 Compliant

Diesel generator set QSB7 series engine

Industrial Diesel Generator Set KD2500-F 50 Hz Fuel Consumption Optimized

Your site. Your light

BC DIESEL GENERATORS TECHNICAL DATA DIESEL GENERATING SET 60HZ

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

power made simple kva RANGE Performance I Durability I Serviceability

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

power moving forward KVA RANGE Performance I Durability I Serviceability

Rental Power 800 kw. Specification sheet. Description. Features. Options

customer driven unsurpassed value

Product of Singapore since Power, Performance, Peace of Mind.

Magnum Mobile Generator MMG125 Specifications

Innovative Reliability for Mobile Power Applications

60 Hz FEATURES. Exclusively from your Caterpillar dealer

Specifications. Cat XQP150 Rental Generator Set. Prime 120 kw, 150 kva 50/60 Hz Switchable EU Stage IIIA. Prime kw (kva)

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

Flexible, Reliable, Connected Power

1500 RPM DIESEL GENERATORS

Rental Power. Power Modules up to 1250 kva can be customised to meet rental customer s exact requirements.

HILIGHT RANGE. Your site. Your light.

AGi20P 2.2 L 20 kw Perkins Powered Diesel Generator AURORA GENERATORS INCORPORATED AURORA STANDARD FEATURES STANDBY POWER RATING 20 KW, 20 KVA, 60 HZ.

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

Magnum Mobile Generator MMG75 Specifications

-Large Capacity Fuel Tank -Low Noise and Vibration -Compact and Light Weight -ATS(AMF) Terminals

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

400 Series 403D-15 Industrial Open Power Unit 24.2 kw / 32.5 hp

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

Atlas Copco Generators

Rental Power QSL9 series engine

Mobile Generator MMG130 Specifications

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

Godwin Hush-Power Generators

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Diesel generator set QSK23 series engine

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

MORE THAN JUST POWER... FG WILSON INDIA KVA PRODUCT RANGE

Magnum Mobile Generator MMG235 Specifications

The power to evolve. QAS generators

SPECIFICATIONS. File _RDA150T3_SA200

Annex A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 400V (750KVA) DIESEL

REOZM SERIES GENERATORS. for Industrial Power Systems 835 kva 2500 kva 668 kw 2000 kw

500 KW / 625 KVA POWERED by

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Diesel Generator Set S3.8 Series Engine

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Generator Set Model - 3 Phase Prime* Standby*

TPD2250H6.3 TECHNICAL DATA

70 KW / 90 KVA POWERED by

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

EG5500CXS POWEREQUIPMENT.HONDA.COM.AU

MOBILAIR M 27/M 31. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 1.90 to 3.15 m³/min (67 to 110 cfm)

SPECIFICATIONS DGK150D/EPA3. File _DGK150D/EPA3_SA310

GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Generator Set Specifications 60 ekw (75 kva)

Bore mm 4.35 in Displacement 8.8 L 535 in³ Stroke mm 4.5 in Compression Ratio 10.1:1

DIESEL GENERATOR SETS POWER RANGE KVA 2015

HILIGHT RANGE. Your site. Your light.

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Rental Power Kubota V2403 series engine

Transcription:

POWER GENERATORS POWER GENERATORS AIRMAN 10.5-50 KVA PRIME RATED PRECISION ENGINEERED JAPANESE RELIABILITY COMPLETE AIR & POWER SOLUTIONS

EXCEPTIONAL PRODUCTIVITY STANDARD: 18 HOURS RUNTIME @ 75% LOAD (SDG25S-3B1N) ENVIRONMENTAL: 40 HOURS RUNTIME @ 75% LOAD (SDG25S-7B1N)

RELIABLE POWER. ON DEMAND. ONE OF JAPAN S LEADING GENERATOR MANUFACTURERS Airman products have been available in Australia for over 10 years, gaining a solid reputation for reliability in even the harshest regions of our country. Featuring superior engineering, Airman generators are ideal for rental and work site power applications as a prime power solution. Built tough and easy to use and maintain, Airman generators are the smart choice for a reliable source of energy. CAPS offer both the Airman standard range of generators and a near mine spec Environmental range. The Environmental range features the following: A much longer continuous operation than you would ever expect without having to refill, all in a portable and easily transportable package. Large capacity fuel tank equipped under the base frame as standard (fully bunded), allowing for continuous operation without an auxiliary fuel tank. with several days of operation possible without a refill. Up to 40 hour run times possible between refills on some models In the case of any water, oil or fuel spillage of over 50% of the bund capacity, a safety sensor will turn on a warning lamp on the control panel. SERVICE SUPPORT Experience the difference with CAPS expert industrial equipment servicing. Our factory-trained technicians will run a full diagnostic inspection on your machine to ensure it keeps running as it should. Using genuine spare parts and model-by-model technical knowledge, you can rest assured that your machine is in good hands.

A SMART INVESTMENT. SIX REASONS WHY 1 LEGENDARY JAPANESE QUALITY Airman generators are produced to the highest standards in a state-of-the-art Japanese factory using premium Japanese engines such as Kubota and Isuzu. 4 CATHODIC ELECTRODE COATING High quality painting process as used in the auto industry. This increases the rust resistance of the enclosure as well as increasing salinity tolerance in harsh environments such as mine sites and coastal areas. 2 SUPER QUIET Low noise engines fully equipped with highly attenuated muffler and exhaust system design. 57 db(a) @ 7m (equivalent of being 1m away from a usual conversation) 5 EASILY TRANSPORTABLE Lightweight and compact enough to be easily transferred on utes and service trucks using the centrally posiitoned lifting lug, allowing hassle-free transportation from one job site to the next. 3 LONG RUN TIMES A large capacity fuel tank and low fuel consumption engine allow the generators to run continuously for an extended period. The bunded Environmental series can run up to 40 hours @ 75% load on a single tank! 6 EASY MAINTENANCE Side doors give quick access to filters and facilitate easy coolant and oil level checks. Mounting and demounting fuel tank has been made simple by making the bottom floor entirely flat. The radiator can be cleaned by removing both side front covers.

FEATURES ENGINE STARTING EFFICIENCY An engine preheating system consisting of a quick heating glow plug to easily start up engine in low temperature conditions. ALL WEATHER CONSTRUCTION A specially designed air inlet port that reduces internal pressure and an insert type seal on the doors work together to prevent rain water penetration. SIMPLE OPERATION Analog control panel equipped with all the features you require to run and take care of your generator. Also features a cable terminal box to easily connect to a distribution board. AVR ALTERNATOR Protecting all your sensitive appliances from voltage variation. AUTOMATIC AIR BLEEDING SYSTEM Automatically bleeds air from the fuel line system. This eliminates the need to prime the fuel system again should the generator be shutdown due to running out of fuel. ELECTRONIC ENGINE GOVERNOR Easily measure and regulate the speed of the engine via a convenient switch. BETTER GENERATING PERFORMANCE Coupled to a low transient reactance alternator and reinforced damper coil. This increases the negative-phase-sequence current capability and minimises the output waveform distortion.

CUSTOM ENGINEERED OPTIONS. CAPS owns and operates an ISO9001 certified manufacturing facility that can modify Airman generators to suit your needs. Even the toughest mine site specifications can be met. Listed below are a number of custom modifications that can be applied to your generator on request. Ask our sales team for additional pricing: High dust filtration Fire extinguisher Lockable battery isolator Lockable starter motor isolator Safety release radiator cap 12v jump start Trailered options Environmental containment bases Custom graphics and safety labels 12v DC flashing light Externally mounted single and three phase IP65 rated switched sockets

PRODUCT SPECIFICATIONS. Model SDG13S SDG25S SDG45S SDG60S Series Identifier -3B1N -7B1N -3B1N -7B1N -3A8N -7A8N -3A6N -7A6N Std. Env. Std. Env. Std. Env. Std. Env. Generator Frequency Hz 50Hz Rated Output (at 50Hz) kva 10.5 20 37 50 Voltage V 50Hz : 400V or 415V Power Factor % 80 Class of Rating Continuous Exciting Method Brushless (with A. V. R.) No. of Phase 3-Phase, 4-Wire Diesel Engine Make and Model Kubota D1503-K3A Kubota V2403- Kubota V3800-DI- Isuzu BB-4BG1T K3A T-K2B No. of Cylinder 3 4 4 4 Type Swirl Chamber Direct Injection, Turbo Charged Total Displacement L 1.499 2.434 3.769 4.329 Rated output 15.6(11.5) 26(19.1) 51.7(38.0) 65.4(48.1) Speed rpm 1,500 Fuel Diesel Fuel Tank Capacity L 58 95 70 145 100 325 135 400 Fuel Consumption (50%/75% load) L/hr 1.8/2.4 3.0/4.0 4.4/6.4 6.0/8.6 Continuous Operation (50%/75%) Hrs 32/24 53/40 23/18 48/36 23/16 71/51 22/16 67/47 Lubricating Oil Capacity L 6.5 9.5 13.2 14 Cooling Water Capacity L 5.7 7 11 15 Battery (Capacity 5hrs) (Ah) 80D26R(55)x1 Dimensions & Weight Overall Length mm 1,480 1,550 1,870 2,090 Overall Width mm 650 700 860 860 Overall Height mm 950 1160 980 1240 1,220 1,590 1,220 1,630 Net Dry Mass kg 520 560 610 685 900 1050 1,120 1,290 Operating Mass kg 580 670 680 820 1,010 1,340 1,260 1,650 Sound Level Sound Pressure Level* db(a) 56 55 59 57 56 59 * At 7m in 4 directions at no load

POWER GENERATORS GET IN TOUCH. 24/7 SUPPORT: 1800 800 878 WEBSITE: CAPS.COM.AU SHOP: CAPSSHOP.COM.AU EMAIL: INFO@CAPS.COM.AU BRANCH LOCATIONS PERTH (HEAD OFFICE) KALGOORLIE MELBOURNE SYDNEY NEWCASTLE ADELAIDE BRISBANE MACKAY DARWIN SOLVING YOUR AIR AND POWER CHALLENGES. CAPS AUSTRALIA PTY LTD. ALL RIGHTS RESERVED. PRO-B05-AIRMAN-2018-V1