nipa63e1-a (1410) Type no. ILS Sensistor ILS500 Leak Detection System Sensistor ILS500 F Tracer Gas Filler

Similar documents
Deans Switch Microfluidics

Instruction of connection and programming of the VECTOR controller

Overview. References TEST SPECIFICATION FORT WORTH, TEXAS TROTTER CONTROLS REPORT X TS-0005 A MODEL ORDER TITLE BY CHK D. Tests

5000TOC Sensor Service Manual

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

3 Phase Smart Controller

Issue 2.0 December EPAS Midi User Manual EPAS35

Application Note. Monitoring Bearing Temperature with ProPAC

KEY. Gas. Air. Aspiration. High Voltage. Low Voltage. Data. Light. BWB-1 Parts Interconnect. Mixing Chamber. Nebuliser. Ignitor. Pump.

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 01

WATERFLUX 3070 Quick Start

ECONOMISER SERIES E2T USER MANUAL

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 03

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

Quick Start Guide TK3/TK4 Thermal System Assembly and Fan Shroud Assembly

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

CEMLINE CORPORATION P. O. BOX 55 CHESWICK, PENNSYLVANIA Phone: (724) FAX (724)

SAX Electronic Valve Actuator

Operation and Maintenance Manual

Cannondale Diagnostic Tool Manual

VECTRIX VX-2 SERVICE MANUAL. Version 1.0/May 2011 VECTRIX, LLC

Service manual. English. F5 Corpus

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

R and R Meritor WABCO Enhanced Easy-Stop Trailer ABS Replacement Kits for Easy-Stop ECU/Modulator Valve Assembly Part Number

Furnace Web Site FAQs. Pro Press 100 / Pro 100 / Pro 100 plus. Lift. Belt Noise

TABLE OF CONTENTS. Page 1

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

Installation Guide. Installing the FRK Hydraulic Compact Unit (HCU) with Parking Brake Valve on International School Buses


Begin to Use The New ESC: Before use the new ESC please carefully check every connections are correct or not. Yellow motor wire B Blue motor wire A

Bruker BioSpin NMR CASE. Installation Manual. Version. NMR Spectroscopy. think forward

Assembly Instructions

OPERATION MANUAL, POWER MODULE-CHARGER SYSTEM. Man Occup. Machine Occup. Cycle Time Setup Time Batch Qty. Equipment Manufacturer Qty

ADDENDUM TO THE STC PRO LOGGER II MANUAL

Steering Angle Sensor (SAS) Replacement on Vehicles Equipped with Electronic Stability Control (ESC)

CEMLINE CORPORATION P. O. BOX 55 CHESWICK, PENNSYLVANIA Phone: (724) FAX (724)

DESCRIPTION & OPERATION

DYNAMIC POWER STEERING (DPS)

Sentronic LP IO-Link CLASS A 617 Series. 617 Series IO-Link CLASS A with Display and Controls Installation Manual

Type 3360, Service Manual. Serviceanleitung Service Manuel

INDEX. 1.Safety Precautions and Warnings...3

EB Conveyor Maintenance Guide

Spray Height Controller

PROBLEM SOLVING GUIDE ELMECO SLUSH MACHINE MODEL FCM

TRITON ERROR CODES ERROR CODE MODEL SERIES DESCRIPTION RESOLUTION

EPAS Desktop Pro Software User Manual

P-600. Technical Manual. Troubleshooting Repairs Replacements

T21 Thermal Differential Switch

Installation Instructions

TECHNICAL SERVICE BULLETIN: TSB

LTX RF LEVEL SENSOR. Instruction Manual

Setup and Programming Manual

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

CEMLINE CORPORATION P. O. BOX 55 CHESWICK, PENNSYLVANIA Phone: (724) FAX (724)

Smart Wi-Fi Sprinkler Timer and Flow Meters

OPERATION INSTRUCTIONS GFA-W-150\300\500\1000

Kelly KDC Series/PM Motor Controller User s Manual

pplication Note (Revision A) Original Instructions Replacing the ST-125 Engine Control with an L-Series Speed Controller

CenterLine Filter Wheel

AQUIS Foam System. Installation, Operation, and Maintenance Instructions AQUIS 1.5, AQUIS 3.0, and AQUIS 6.0

PRESSURE SENSOR INSTRUCTIONS

ENGINE DISPLACEMENT 2000 NUMBER OF VALVES 16 ENGINE SET NUMBER

Read this document carefully before implementing the upgrade!

Installation Guide. Auxiliary Pressure Control Manifold on 6890 GC Accessory G1570A

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Motor Protection With The MonitorPro

REV F2.0. User's Manual. Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28

TIRE PRESSURE AND MONITORING SYSTEMS (DIAGNOSTICS)

Pendulum control & isolation valve with extended control range with Logic interface

Rosemount 402 and 402VP

Devices Supported: KEB48220 KEB48221 KEB48300 KEB48301 KEB48400 KEB48401 KEB48600 KEB48601 KEB72330 EB KEB72450 KEB EB KEB72600 KEB

MAGPOWR Spyder-Plus-S1 Tension Control

KeContact P20. User manual

LEAK TEST PROCEDURE APPLICABLE TO DC3 INTELLI-GRIP LIFTERS MODELS MRT4-DC3, MRTA8-DC3, MRTALP8-DC3 AND PC/P1-DC3 SERIES

Senior Swing Control Box. Table of Contents

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A

Additive Injectors. AccuPlus. Maintenance. The Most Trusted Name In Measurement

IVTM Installation Manual

Open Center Compact Valve Custom Installation Guide Rev A

Z TECHNICAL INSTRUCTIONS

Relay Retrofit Program Cutting Tool Safety Guide

C50254A PH3 AIR INTAKE SHUT-OFF VALVE DODGE 6.7L CUMMINS WITH POWERGUARD SMART OVERSPEED LIMITER

Table of Contents HAVE A QUESTION? WE RE HERE TO HELP. CALL US AT OR VISIT JACOINC.COM/SUPPORT

Section 55 Chapter 6

1.0 Features and Description

TT /17 INSTALLATION INSTRUCTIONS. Introduction. Required Tools and Equipment

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine

EVAP system, servicing

320iB Mark II/436LiB, 525iB/536LiB, 530iBX

1. INTRODUCTION AND SYSTEM DESCRIPTION BLOCK DIAGRAM GENERAL INFORMATION GLOSSARY... 7

Multi Wheel Bluetooth Tire Pressure Monitoring System User Manual Model: External

An ISO 9001:2008 Registered Company

WARNING Warnings are indicated when mishandling this product might result in death or serious injury to the user.

PRODUCT INFORMATION BULLETIN #3365 DIGITAL MOTOR CONTROL PLATTER SYSTEMS For Serial Number and After

T P M S. Multi Wheel Bluetooth. Tire Pressure Monitoring System. User Manual. Model: External

Periodic Maintenance 7-1

Barak5/3 Printer. Service Visit Identify problem, fix it and proceed to Maintenance Procedure. Maintenance Procedure. Under Warranty.

Maintenance Information

Transcription:

S E R V I C E M A N U A L Type no. ILS.210.306 Sensistor ILS500 Leak Detection System Sensistor ILS500 F Tracer Gas Filler 1

Content Safety During Service 1 General Information 7 1.1 About This Document 7 1.2 Versions 7 2 Components 8 2.1 Exploded View (ILS500) 8 2.2 Exploded View (ILS500 F) 10 2.3 Interior View ILS500 13 3 Troubleshooting 15 4 Service Instructions 16 4.1 Safety Equipment, Tools and Consumables 17 4.2 Open the Cover 18 4.3 Changing Fuses 19 4.4 Changing Power Supply 20 4.5 Changing Main PCB 21 4.6 Changing Pressure or Vacuum Sensor 22 4.7 Changing Venturi Pump 23 4.8 Changing Gas Valves 24 4.9 Changing Pilot Valves 25 4.10 Changing Valve Block 26 4.11 Changing PLC and AD Module 27 4.12 Changing Display 28 4.13 Changing ISH2000 29 4.14 Changing Panel Cover (ILS500 F Model) 30 4.15 Functional Verification 31 5 Software Update 41 5.1 Update the Software 41 5.2 Reset to Factory Configuration Parameters 41 5.3 Supported USB Memories 41 6 Drawings 42 3

4

Safety During Service Definitions of Warning, Caution and Notice Warning Indicates procedures that must be strictly observed to prevent hazards to persons. Caution Indicates procedures that must strictly be observed to prevent damage to or destruction of the instrument. Notice Indicates special requirements the user must comply with. Safety Instructions Failure to observe the following precautions could result in serious personal injury: Warning Pay attention to the Warnings, Cautions and Notices in the User Manual for the product before operation. Warning The ILS500 must never be introduced to pressures higher than that approved for the object to be tested and never beyond the ILS500 specification. Failure to observe the following precautions could result in damage to the equipment: Caution During service at the Service Center, all devices must be handled exclusively in an ESD Protected Area (EPA). Devices must be transported from one EPA to another only in ESD shielding packages. 5

Caution On Customers site, during exchange or maintenance of electronic card, the service personnel must wear a ESD coat and use disposable wristband. Caution Risk assessment is the sole duty of the person handling the ILS500. Notice Check that all relevant legislation and safety standards are complied with before putting ILS500 into service. 6

1 General Information 1.1 About This Document 1.1.1 Document History The Sensistor ILS500 is an all-in-one tracer gas leak detection system with all necessary functions integrated in one very compact housing. The Sensistor ILS500 F is a tracer gas filler. Please read this Service Manual carefully before performing service on the ILS500. When reading, please pay particular attention to the WARNINGS, CAUTIONS and NOTICES found throughout the text. This document is only intended for INFICON service personnel working with the ILS500 Leak Detection System. 1.2 Versions Revision Date Remark a 10-2014 First edition This manual applies to the product versions below. Unit Name Software version Leak Detector ISH2000 6 or higher Tracer Gas Filler ILS500 3 or higher Probe P50 2 or higher For more information about the latest software versions, please contact your local INFICON office. 7

2 Components 2.1 Exploded View (ILS500) 58 59 60 61 63 64 65 66 67 68 69 71 72 73 74 75 2 4 30 14 27 31 51 52 10 56 7 1 76 11 26 15 55 16 28 5 23 6 8 25 48 32 54 18 33 53 24 32 17 27 9 19 21 27 22 8

Pos Description Part No. Pos Description Part No. 1 Power supply ILS500 591-575 32 Torx screw M5x10 fzb 591-954 2 PLC FX3UC 591-718 33 Phillips screw M3x8 fzb 591-483 4 A/D CONVERTER BOARD 591-572 48 Cover plate 591-579 5 Valve ramp 591-565 51 Nut M6 591-586 6 Power inlet 591-576 52 Lock washer M6 591-587 7 DIN rail 35 mm, l=0,50m 591-580 53 Lock washer M5 591-609 8 Fuse holder 591-577 54 Lock washer M4 591-776 9 Hex nut M6M M4 A2 591-019 55 Front stand 591-573 10 Washer BRB 5,3x10x1 A2 591-108 56 Back stand 591-574 11 WEW 35/2 591-434 58 Contact for HMI-PLC 591-614 14 HMI-Panel* 599-027 59 CA51 operating panel cable 591-544 15 Sensistor ISH2000P* 599-073 60 CA52 ISH2000 RS232 cable 591-545 16 Weld box ILS500* 599-025 61 CA53 pilot valve cable 591-546 17 Valve block P510* 599-023 63 CA55 PLC I/O cable 591-548 18 Torx M4x8 fzb 591-260 64 CA56 PLC AIN cable 591-549 19 Pneumatical label 1 ILS500 598-073 65 CA57 PLC RS422 cable 591-550 20 Pneumatical label 2 ILS500 598-074 66 KB1022 printer cable 591-777 21 Electrical label ILS500 598-075 67 CA59 PLC power cable 591-552 22 ILS500 label 598-076 68 CA60 power cable 1 591-553 23 Nipple straight outer g1 591-561 69 CA61 power cable 2 591-554 24 Pneumatic coupling I straight 4 4 591-567 71 CA64 pressure gauge cable 591-571 25 Fuse 2A T 591-578 72 CA73 Rear probe cable 591-955 26 Torx screw M4x6 591-581 73 CA71 ISH2000 power cable 591-956 27 Torx screw M4x12 591-298 74 CA72 ISH2000 APC cable 591-957 28 Torx screw M4x20 591-583 75 PLC and software ILS500 591-845 30 Plastic washer M4 4.3x9x0.8 PA 591-584 76 Torx MC6S 5X25 FZB 591-289 31 ILS500 electronic board 591-603 * This spare part comprises several parts, for details see Component Details on page -12. 9

2.2 Exploded View (ILS500 F) 58 59 61 63 64 65 66 67 68 69 71 75 2 4 30 27 14 31 51 52 56 1 26 7 11 76 55 10 77 16 28 5 23 79 6 8 25 48 54 32 18 33 53 78 17 27 24 9 19 21 20 22 10

Pos Description Part No. Pos Description Part No. 1 Power supply ILS500 591-575 32 Torx screw M5x10 fzb 591-954 2 PLC FX3UC 591-718 33 Phillips screw M3x8 fzb 591-483 4 A/D CONVERTER BOARD 591-572 48 Cover plate 591-579 5 Valve ramp 591-565 51 Nut M6 591-586 6 Power inlet 591-576 52 Lock washer M6 591-587 7 DIN rail 35 mm, l=0,25m 591-580 53 Lock washer M5 591-609 8 Fuse holder 591-577 54 Lock washer M4 591-776 9 Hex nut M6M M4 A2 591-019 55 Front stand 591-573 10 Washer BRB 5,3x10x1 A2 591-108 56 Back stand 591-574 11 WEW 35/2 591-434 58 Contact for HMI-PLC 591-614 14 HMI-Panel* 599-027 59 CA51 Operating panel cable 591-544 16 Weld box ILS500* 599-025 61 CA53 Pilot valve cable 591-546 17 Valve block P510* 599-023 63 CA55 PLC I/O cable 591-548 18 Torx M4x8 fzb 591-260 64 CA56 PLC AIN cable 591-549 19 Pneumatical label 1 ILS500 598-073 65 CA57 PLC RS422 cable 591-550 20 Pneumatical label 2 ILS500 598-074 66 KB1022 Printer Cable 591-777 21 Electrical label ILS500 598-075 67 CA59 PLC power cable 591-552 22 ILS500 label 598-076 68 CA60 Power cable 1 591-553 23 Nipple Straight outer g1 591-561 69 CA61 Power cable 2 591-554 24 Pneumatic coupling I straight 4 4 591-567 71 CA64 Pressure gauge cable 591-571 25 Fuse 2A T 591-578 75 PLC och software ILS500 591-845 26 Torx screw M4x6 591-581 76 Torx screw MC6S 5X25 FZB 591-289 27 Torx screw M4x12 591-298 77 Panel cover ILS500 F 598-069 28 Torx screw M4x20 591-583 78 Torx screw M5x60 591-610 30 Plastic washer M4 4.3x9x0.8 PA 591-584 79 Plug 12 mm 591-976 31 ILS500 electronic board 591-603 * This spare part comprises several parts, for details see Component Details on page -12. 11

2.2.1 Component Details 1 2 3 4 Pos Description Part No. 1 HMI-Panel 599-027 2 Sensistor ISH2000P 599-073 3 Weld box ILS500 599-025 4 Valve block P510 599-023 12

2.3 Interior View ILS500 1 10 9 8 7 2 3 4 5 6 1 Venturi Pump (Ejector) 2 Evacuation Valve 3 Tracer Gas Fill Valve 4 Test Port Valve 2 5 Vacuum Sensor Control Valve 6 Pressure Sensor (HP model only) 7 Vacuum Sensor 8 Pressure Sensor 9 Pilot Valve 6 10 Pilot Valve 1 Pilot Valve Ramp Position Valve 5A+6A Main Air Valve 5B+6B Venturi Pump Supply 4A Evacuation Valve 4B Tracer Gas Fill Valve 3A Test Port 2 Valve 3B Sensor Protection Valve 2A Tooling Valve 1 2B Tooling Valve 2 1A Tooling Valve 3 1B Tooling Valve 4 13

1 6 2 3 4 5 1 Main PCB 2 PLC 3 AD Module 4 Fuse holder 5 Power Supply 6 USB 14

3 Troubleshooting Tested Unit Tested Feature Reason for Error Action Vacuum and Pressure Sensors Zero point Broken/disconnected cable. Wrong set A/D parameters. Broken vacuum or pressure sensor. Venturi Pump Maximum vacuum No signal to Venturi pilot valve. No signal to Evacuation pilot valve. Test Port 2 Valve Function No signal to pilot valve. Tracer Gas Fill Valve Function No signal to pilot valve. Evacuation Valve Function No signal to Evacuation pilot valve. Check cable of sensors. Check and adjust Analog Input settings. Replace sensor if m value needs more than 20% change. Replace sensor. Check Venturi Pump output. For more help, please contact INFICON. Check Evac Valve output. For more help, please contact INFICON. Check Test Port 2 output. For more help, please contact INFICON. Check Fill Valve output. For more help, please contact INFICON. Check Evac Valve output. For more help, please contact INFICON. Lamp Function No signal from PLC. Check PLC output. For more help, please contact INFICON. Tooling Valves Function No signal from PLC. Check PLC output. For more help, please contact INFICON. 15

4 Service Instructions Caution During service at the Service Center, all devices must be handled exclusively in an ESD Protected Area (EPA). Devices must be transported from one EPA to another only in ESD shielding packages. Caution On Customers site, during exchange or maintenance of electronic card, the service personnel must wear a ESD coat and use disposable wristband. 16

4.1 Safety Equipment, Tools and Consumables When performing service of the ILS500 the following equipment may be needed. 1 2 3 4 T20 T25 5 6 7 8 2400 9 577 Pos Description Comment 1 Allen Keys (hexagonal 3 and 4 mm) 2 Torx Key (T20 and T25) 3 Screwdriver (Philips 1 or Pozidriv 1) 4 Protective Eyewear When performing tooling output test. 5 Protective Ear Plugs When performing tooling output test. 6 Tracer Gas 7 Compressed Air (10 bar) 8 Loctite 2400 9 Loctite 577 17

4.2 Open the Cover A Disassemble 1 Unplug power supply. 2 Use a T25 key to remove the two screws holding the cover (A). 3 Slide the cover back and lift it off. Rock the rear end of the cover up and down a few times to loosen. Assemble 1 Reinstall the cover (A). 2 Reinstall and tighten the screws. 18

4.3 Changing Fuses Part Part No. Qty Consumables Fuse, 2A slow for Sensistor ISH2000 591-578 2 A Disassemble 1 Unplug power supply. 2 Remove the lid (A) containing the fuses. 3 Remove the fuses. Assemble 1 Install new fuses. 2 Reinstall the lid (A) containing the fuses. 19

4.4 Changing Power Supply Part Part No. Qty Consumables Power supply 591-575 1 A Disassemble 1 Unplug power supply. 2 Open the cover, see Open the Cover on page -18. 3 Unplug power supply. 4 Loosen all cables on the power supply (A). 5 Remove the power supply (A) by loosen the two screws in the bottom. Assemble 1 Install new power supply. 2 Reinstall and tighten the screws. 3 Reinstall all cables. 4 Reinstall the cover. 20

4.5 Changing Main PCB Part Part No. Qty Consumables Electronic board 591-603 1 A Disassemble 1 Unplug power supply. 2 Open the cover, see Open the Cover on page -18. 3 Unplug power supply. 4 Loosen all cables on the power supply. 5 Remove the power supply by loosen the two screws in the bottom. 6 Loosen all cables attached to the main PCB (A). 7 Remove the six screws holding the main PCB (A). Assemble 1 Install new PCB and tighten the screws. 2 Reinstall all cables attached to the main PCB. 3 Reinstall the screws holding the power supply. 4 Reinstall all cables attached to the power supply. 5 Reinstall the cover. 21

4.6 Changing Pressure or Vacuum Sensor Part Part No. Qty Consumables Valve block P510 included in 599-023 1 A Disassemble 1 Unplug power supply. 2 Open the cover, see Open the Cover on page -18. 3 Unplug power supply. 4 Loosen the cable from the contact. 5 Remove the Sensor contact using a wrench. Assemble 1 Install the new Sensor contact. 2 Reinstall the cable. 3 Reinstall the cover. 22

4.7 Changing Venturi Pump Part Part No. Qty Consumables Valve block P510 included in 599-023 1 A Disassemble 1 Unplug power supply. 2 Open the cover, see Open the Cover on page -18. 3 Remove the exhaust hose from the barbed hose fitting. 4 Unscrew and remove the barbed hose fitting and the plastic washer. 5 Use a 4 mm Allen key to remove the four screws holding the Venturi pump (A). 6 Remove the o-ring under the Venturi pump (A). Remove the hose from Venturi inlet. Push hose into connector and press orange ring down to release hose, then pull hose out. 7 Remove the hose fitting from the Venturi pump (A). Assemble 1 Install new Venturi or use compressed air jet and a cotton bud, pipe cleaner or small brush to clean the nozzles inside the Venturi. 2 Replace hose fitting on Venturi inlet. 3 Reconnect inlet hose. 4 Clean o-ring and install in groove on valve manifold. 5 Reinstall and tighten the four screws. 6 Put plastic washer inside Venturi outlet and reinstall barbed fitting. Tighten with spanner. 7 Reconnect the exhaust hose. 23

4.8 Changing Gas Valves 8 Run through the hardware test again to test that the Venturi delivers adequate max vacuum. 9 Reinstall the cover. Part Part No. Qty Consumables Valve block P510 included in 599-023 1 A Disassemble 1 Unplug power supply. 2 Open the cover, see Open the Cover on page -18. 3 Use a 3 mm Allen key to remove the four screws holding the valve (A) to be changed. 4 Lift out the old valve (A). Assemble 1 Install new valve. 2 Tighten the screws 2-3 mm (0.08-0.12 in.) at a time moving the key from screw to screw so that the valve doesn t tilt much. 3 Tighten the screws and replace the cover. 4 Run through the hardware test again to test that the changed/removed valve(s) perform as required. 5 Use hand probe to check that there is no external leakage (this part of Hardware Test is routine). 24

6 Reinstall the cover. 4.9 Changing Pilot Valves Part Part No. Qty Consumables Valve ramp 591-565 1 A Disassemble 1 Unplug power supply. 2 Open the cover, see Open the Cover on page -18. 3 Use small screw driver to loosen the screw holding the valve (A). You must back the screw all the way out until you feel it jumping in the thread entrance. 4 Push down on the LEDs while pressing the screw down until you feel the locking mechanism snap. 5 Lift the old valve (A) out from the coil side. If the valve does not come off, repeat steps 3 and 4 making sure the screw is completely backed out. Assemble 1 Push the screw in while inserting the new valve. Insert the end facing the screw first and then push the coil side down. 2 Tighten the screw. 3 Reinstall the cover. 25

4.10 Changing Valve Block Part Part No. Qty Consumables Valve block P510 included in 599-023 1 A Disassemble 1 Unplug power supply. 2 Open the cover, see Open the Cover on page -18. 3 Use a Torx screwdriver to loosen the three screws on the back. 4 Loosen the Pilot Valve cable, Vacuum Sensor cable and the Pressure Sensor cable from the Valve Block (A). 5 Lift the Valve Block (A) out and clean it from contamination. Assemble 1 Install the new Valve Block. 2 Reinstall all cables. 3 Reinstall and tighten the screws. 4 Reinstall the cover. 26

4.11 Changing PLC and AD Module Part Part No. Qty Consumables PLC FX3UC 591-718 1 A/D CONVERTER 591-572 1 BOARD A Disassemble 1 Unplug power supply. 2 Open the cover, see Open the Cover on page -18. 3 Loosen all cables attached to the PLC and AD Module (A). 4 Unlock the hooks on the back. 5 Remove the PLC and AD Module (A). Assemble 1 Install new PLC and AD Module. 2 Lock the hooks on the back. 3 Reinstall all cables. 4 Reinstall the cover. 27

4.12 Changing Display Part Part No. Qty HMI-Panel 599-027 1 Consumables A Disassemble 1 Unplug power supply. 2 Open the cover, see Open the Cover on page -18. 3 Remove both side covers. 4 Use a Torx screwdriver to remove the fours screws holding the display panel. 5 Carefully lift out the display panel. 6 Use a Torx to remove the four screws holding the display (A). 7 Remove the old display (A). Assemble 1 Install new display. 2 Reinstall and tighten the screws holding the display. 3 Reinstall and tighten the screws holding the panel. 4 Reinstall the cover. 28

Notice For information about how to replace lamps and buttons in the display panel, please contact INFICON. 4.13 Changing ISH2000 Part No. Qty Sensistor ISH2000P 599-073 1 Consumables Part A Disassemble 1 Unplug power supply. 2 Open the cover, see Open the Cover on page -18. 3 Remove both side covers. 4 Use a Torx screwdriver to remove the four screws holding the ISH2000 (A). 5 Carefully lift out the ISH2000 (A). 6 Loosen all cables attached to the ISH2000 (A). 7 Remove old ISH2000 (A). 29

Assemble 1 Install new ISH2000. 2 Reinstall all cables. 3 Reinstall and tighten the screws. 4 Reinstall the cover. 4.14 Changing Panel Cover (ILS500 F Model) Part Part No. Qty Consumables Panel cover ILS500 F 598-069 1 A Disassemble 1 Unplug power supply. 2 Open the cover, see Open the Cover on page -18. 3 Remove both side covers. 4 Use a Torx screwdriver to remove the two screws holding the Panel Cover (A). 5 Lift out the Panel Cover (A). 30

6 Remove old Panel Cover (A). Assemble 1 Install new Panel Cover. 2 Reinstall and tighten the screws. 3 Reinstall the cover. 4.15 Functional Verification 4.15.1 Perform Hardware Test Notice Before performing the hardware test, carefully check that your tracer gas and compressed air feed pressures are correct. Wrongly set pressure can cause erroneous test results. Hardware Test Press TEST OUTPUTS ILS500 plugged Vacuum: ILS500 + Object Pressure: 0.00 0.00 bar bar TEST STOP Report For troubleshooting and testing of the system, use Service menu. For remote troubleshooting, use Service Run menu. Venturi Pump and all Gas Valves can be tested automatically. The hardware test is a diagnostic tool helping you in preventive maintenance as well as service and repair. The test takes you through a number of steps testing all units that are subject to wear and should thereby help you to find almost any problem in the ILS500 system. Notice Run through the whole sequence to interpret the results correctly. You will need the reference table at the end of this section to help you interpret the test results correctly. Keep this manual at hand when performing the test. You can choose to test according to the limits of your specific application. 31

1 Setup all parameters for your test object (or load desired recipe) and connect a leak free sample. 2 Set test selection switch to ILS500 + Object for application specific hardware test. You can also test the ILS500 against factory specification. In this case you should plug both test ports using the plugs delivered with the units. 3 Remove ISO to NPT converters if installed. Set test selection switch to ILS500 plugged for factory specified hardware test. 4 The Continue button will be displayed at the end of each test step. Press Continue for next test step. Pressure and Vacuum Sensors Hardware Test Pressure and Vacuum Sensors Zero Points are OK Vacuum: Pressure: 0.00 0.00 bar bar CONTINUE STOP Report Zero points of pressure and vacuum sensors are tested. Possible results: Zero Points are OK Vacuum Zero Point not OK Offset zero point can result in: Incorrect gas filling Erroneous vacuum or pressure decay results Evacuation Valve Hardware Test Evacuation Valve No Internal Leakage Vacuum: Pressure: -0.03 0.00 bar bar CONTINUE STOP Report Evacuation valve is checked for internal leakage. Possible results: 32

No Internal Leakage Internal Leakage Internal leakage can result in: False vacuum decay rejects Increased tracer gas consumption Venturi Pump Hardware Test Venturi Pump Max Vacuum OK Vacuum: Pressure: -0.88 0.00 bar bar CONTINUE STOP Report Checking max vacuum of Venturi pump. Possible results: Max Vacuum OK Poor Max Vacuum Poor max vacuum can result in: Failed pre-evacuation Slower evacuation Manifold Tightness (gross) Hardware Test Manifold Tightness No Leakage from Outside Vacuum: Pressure: -0.82 bar 0.00 bar CONTINUE STOP Report The overall tightness of the manifold is tested using the vacuum raise method. Possible results: No Leakage from Outside Leakage from Outside 33

Leaks in the manifold can result in: False vacuum decay rejects Increased gas consumption Minor external leakage will be found later during the gas test step. Vacuum Sensor Valve Hardware Test Vacuum Sensor Valve Valve works! Vacuum: 0.00 bar Pressure: 0.00 bar CONTINUE STOP Report This checks that the valve shuts to protect vacuum sensor before filling. Possible results: Valve works Faulty! Malfunction can result in: Damage to vacuum sensor Failed pre-evacuation Tracer Gas Fill Valve Hardware Test Tracer Gas Fill Valve No Internal Leakage Vacuum: Pressure: 0.00 bar 0.00 bar CONTINUE STOP Report The step tests the gas fill valve for internal leakage by registering pressure rise behind the valve. Possible results: No Internal Leakage 34

Internal Leakage Internal leakage can result in: Erroneous pressure decay results False vacuum decay rejects increased gas consumption Test Port 2 Valve Hardware Test Test Port 2 Valve Valve works! Vacuum: 0.00 bar Pressure: 0.00 bar CONTINUE STOP Report Notice This test will fail if both test ports are connected to a test object. Proceed and then repeat the entire hardware test sequence with both ports plugged to perform this test step. This step tests Test Port 2 valve for internal leakage by registering pressure rise behind the valve. Possible results: No Internal Leakage Internal Leakage Internal leakage can result in: False blockage test accepts Tracer Gas Fill Valve Hardware Test Tracer Gas Fill Valve Valve works! Vacuum: 0.00 bar Pressure: 0.50 bar CONTINUE STOP Report This step tests that tracer gas fill valve opens to fill gas. Test will fail if tracer gas feed pressure is too low. If this is the case, adjust pressure and restart hardware test from beginning. 35

Possible results: Valve works Faulty! Malfunction will result in: Failed gas filling External Gas Leaks Hardware Test Check for Leaks with Hand Probe Vacuum: 0.00 bar Pressure: 0.50 bar CONTINUE STOP Report The ILS500 is now prepared for a manual test for external leakage. Use the hand probe to check for leakage 1 Start by checking all connections between the ILS500 and your test object. Follow each test line carefully and check every joint. 2 Proceed to check around the gas valves and manifold inside the ILS500. Manifold Tightness (gross) Hardware Test Manifold Tightness Internal Leakage Vacuum: 0.00 bar Pressure: 0.46 bar CONTINUE STOP Report The overall tightness of the manifold is tested using the pressure decay method. This is a complement to the gas test, revealing leakage out, through the exhaust etc. Possible results: No Internal Leakage Internal Leakage Internal leakage can result in: False pressure and vacuum decay rejects Increased tracer gas consumption 36

Evacuation Valve Hardware Test Evacuation Valve Valve works! Vacuum: 0.00 bar Pressure: 0.00 bar CONTINUE STOP Report This step tests that evacuation valve opens to release tracer gas to exhaust. Same test as previously but under pressure instead of vacuum. Possible results: Valve works Faulty! Malfunction will result in: Failure to terminate test cycle 37

Indicator Lamps Hardware Test Lamp in Start Button OK? Vacuum: 0.00 bar Pressure: 0.00 bar CONTINUE STOP Report Hardware Test Green Lamp (Top Left) OK? Vacuum: 0.00 bar Pressure: 0.00 bar CONTINUE STOP Report Hardware Test Red Lamp (Bottom Left) OK? Vacuum: 0.00 bar Pressure: 0.00 bar CONTINUE STOP Report This is a manual test. The ILS500 lights up one lamp at the time. Simply check that the right lamp comes on. 1 Check function of each lamp by pressing Continue. 2 Remember to check lamps on both touch panel and external control panel (if installed). 38

START and STOP buttons Hardware Test Press Start Button (Top Right) OK? Vacuum: 0.00 bar Pressure: 0.00 bar STOP Report Hardware Test Press Stop Button (Bottom Right) OK? Vacuum: 0.00 bar Pressure: 0.00 bar STOP Report This is a manual test. The test continues when the correct button is pressed. The test checks the activated START and STOP buttons only. Use INPUT menu under Service menu to check buttons that are turned off. 39

4.16 Hardware Error Messages Error Message Reason for Error Corrective Action* Detector Power Off Detector Error + Check Probe and Cable** Detector Error + Check Sensor, Voltage Error** Detector Error + Error [Driver name]** Hardware Error Vacuum Sensor Error Hardware Error Pressure Sensor Error No power to the Leak Detector. Probe cable disconnected. Gas sensor damaged. Active Probe error. No power to vacuum sensor. Sensor not connected to AD. Damaged vacuum sensor. No power to pressure sensor. Check the power cable to the detector (internal or external). Connect cable. Replace probe or sensor. Consult Active Probe Manual. Check cable to sensor. Check connection to AD. Send in for repair. Check cable to sensor. Sensor not connected to Check connection to AD. AD. Damaged pressure sensor. Replace sensor. Analog Inputs Power Off No power to AD module. Check power cable on left side of AD module. Emergency Stop Activated Emergency Stop not Reset. Pull out emergency Stop Button to reset. ISH2000 Comm. Error ISH2000 printer mode turned off manually. Restart system. ISH2000 serial cable disconnected. Connect cable (internal or external). * Contact your supplier if the suggested action does not clear the error. ** Error message on ISH2000 display. 40

5 Software Update 5.1 Update the Software 1 Turn the ILS500 on. 2 When the hourglass symbol disappears, press a finger on the screen and hold until the screen turns gray and following message appears: Tap anywhere on screen or touch calibrate will start in 10 seconds. 3 Lift the finger and press once again to enter the service menu. 4 Click Erase Project, then click Yes to delete the project. 5 Turn the ILS500 off. 6 Insert the USB memory with the new Software. 7 Turn the ILS500 on. 8 Wait for the Update project window. Click Yes to copy project from USB memory. The new updates will now be running, this may take a while. The ILS500 will automatically restart once the new software is loaded into the instrument. 9 Wait for the Project transfer window. Click Yes to download PLC program. 10Choose the program you want to run and click Yes. 11Update is completed and the ILS500 will start as usual. Notice If the update fails, repeat this procedure. 5.2 Reset to Factory Configuration Parameters Notice After updating the software in ILS500 INFICON recommends to do a system reset. 1 Click Menu >> Advanced Settings >> Service Menu >> System Reset. 2 Click Yes to reset the ILS500 to factory default. 5.3 Supported USB Memories The ILS500 supports USB 2.0 full speed 12 Mbps and is backwards compatible with USB 1.1. USB memories must be USB mass storage device class compatible and have a maximum power consumption of 200 ma when no external field buss module is mounted. 41

6 Drawings DB9F HMI (display) Front panel Buttons & LEDs U? A A MAN DB25M HMI DB37F KB1022 (replaces CA58) HMI adapter PCB CA70 (New!) DB37F CA51 PLC CA59 PLC RS232 Removed fromdesign Leak Detector DB9M CA57 PRINTER DB9M PLCIN CA52 CA55 PLC A/D B B ETHERNET AIN34 CA56 RJ45 Phoenix 10-pin Vacuum & pressure transmitters OPTIN2 Weid SLD, 5-pin OPTIN1 Weid SLD, 5-pin PLCOUT CA55 IDC 20-pin SAFETY Weid SLD, 6-pin CA53 SMC valve terminal C C CONTROL Weid SLD, 8-pin CA60 D D IL S500-PCB1- Rev5 (MAN and HMI connectors removed) ISH2000 AC inlet CA61 AC/DC supply 230VAC 24VDC Design IL S500 with ISH2000 INFICON AB Page Block diagram & internal cables Box 76 S-581 02 Linköping Size A3 Revision 01B Author DA Sweden Date 2013-05-22 Time 15:58:23 Sheet of File C:\Altium \MI SC\I L S500-ISH2000\blockdiagram\IL S500-ISH2000_block.SchDoc 1 1 2 2 3 3 4 4 5 5 6 6 7 7 1 1 8 8 DB25F V A LVES DB25M DB9M H2000 DB9M PL C ERELAY1 RS232 EREL AY2 PL CPWR HMI1 DB37F PRINTER1 DB9M Relay IDC 20-pin Driv ers STATUS Weid SLD, 6-pin TOOLING Weid SLD, 8-pin H2000APC DB25F APUNIT DB25F OPT1 Phoenix 4-pin SENSPWR Phoenix 4-pin DETPWR Phoenix 2-pin PWRIN Phoenix 3-pin CA72 (New! Updated CA62) CA64 CA71 (New! Updated CA54) CA73 LEMO (rear) A PC DB25F I L S500 (P510) PC B 1 R ev4 all connections not shown! C onnector s not mounted (New! Updated CA63) Headphone LEMO (front) LEMO (mounted on rear panel) 42

43

INFICON AB Westmansgatan 49, S-58216 Linköping, Sweden reach.sweden@inficon.com UNITED STATES TAIWAN JAPAN KOREA SINGAPORE GERMANY FRANCE UNITED KINGDOM HONG KONG Visit our website for contact information and sales offices worldwide. www.inficon.com Document: