Specifications. 3406C Generator Set Electric Power

Similar documents
220 to Volts or 1800 RPM

220 to Volts or 1800 RPM

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

Voltage 220 to or 1800 RPM

3412C Generator Set Electric Power. Specifications. Benefits and Features

Voltage 208 to 600. Engine Specifications C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel Compression Ratio 16.5:1 Aspiration

220 to volts. Electronic unit injection

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

220 to volts. Engine Specifications 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel 170 mm (6.69 in) Compression Ratio 14.

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

Continuous, Prime, Standby, Mission Critical

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

400 to 11,000 Volts. Standby, Prime, Continuous

Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

Voltage 220 to or 1800 RPM. Engine Specifications C32 TA, V-12, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in)

Specifications. C13 Generator Set Electric Power

Generator Set Specifications 100 ekw (125 kva)

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

Generator Set Specifications 60 ekw (75 kva)

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

like mission critical Backed by the worldwide l provide the reliabi Mission Critical LEHE1075

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 600 Volts

STANDBY 400 ekw 500 kva

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

P R I M E e k W k V A 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

MISSION CRITICAL STANDBY. 50 Hz 1500 rpm Volts DIESEL GENERATOR SET FEATURES

including r installations. Backed by the worldwide l provide the reliabi Prime LEHE1073

MISSION CRITICAL 800 ekw 1000kVA 60 Hz 1800 rpm 480Volts

MISSION CRITICAL STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

PRIME 225 ekw 281 kva

STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

DIESEL GENERATOR SET FEATURES

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

Mission Critical Standby 1400 ekw 1750 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

Engine Specifications C32 ACERT TA, V-12, 4-stroke Water-cooled Diesel. Compression Ratio 15.0:1 Turbocharged Aftercooled.

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

Aftercooler (Separate Circuit) N/A N/A

Bore mm 4.35 in Displacement 8.8 L 535 in³ Stroke mm 4.5 in Compression Ratio 10.1:1

STANDBY 700 ekw 875 kva 60 Hz 1800 rpm 600 Volts

Bore mm 4.0 in Displacement 5.7 L 350 in³ Stroke 88.4 mm 3.48 in Compression Ratio 9.4:1

C32 ACERT Generator Set Electric Power

ESP 550 ekw 688 kva 60 Hz 1800 rpm 480 Volts

Cat C32 Diesel Generator Sets

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

Generator Set Specifications Rating (ekw) Rating (kva) Engine Specifications C32 ACERT TA, V-12, 4-stroke Water-cooled Diesel

Cat C32 Diesel Generator Sets

DIESEL FEATURES GENERATOR SET

Cat 3516B Diesel Generator Sets

Cat C Diesel Generator Sets

Cat C32 Diesel Generator Sets

Enclosures. Options Caterpillar yellow or white paint Integral dual wall fuel tank base for total fluid containment (fuel, oil and coolant)

Cat 3516C Diesel Generator Sets

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

Cat C Diesel Generator Sets

PRIME 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

Cat 3412 Diesel Generator Sets

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A

CONTINUOUS 728 ekw 910 kva 50 Hz 1500 rpm 400 Volts

STANDBY 2000 ekw 2500 kva 50 Hz 1500 rpm Volts

Standby 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

Cat 3512 Diesel Generator Sets

Standby 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

Hydraulic electronic unit injection

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 440 Volts

STANDBY 484 ekw 605 kva 50 Hz 1500 rpm 400 Volts

PRIME 910 ekw 1138 kva 60 Hz 1800 rpm 480 Volts

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

CONTINUOUS 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

Cat 3512 Diesel Generator Sets

PRIME 920 ekw 1150 kva 50 Hz 1500 rpm 400 Volts

3516B Generator Set Electric Power

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm Volts

Generator Set Specifications 320 ekw (400 kva)

Generator Set Specifications 480 ekw 600 KVA

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 220 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 1825 ekw 2281 kva 60 Hz 1800 rpm 480 Volts

Cat 3512B Diesel Generator Sets

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm Volts

Cat 3516B Diesel Generator Sets

STANDBY 250 ekw 313 kva 60 Hz 1800 rpm 208 Volts

CONTINUOUS 1230 ekw 1538 kva 60 Hz 1800 rpm 480 Volts

Transcription:

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications Generator Set Specifications Minimum Rating Maximum Rating Voltage Frequency Speed 275 ekw (275 kva) 400 ekw (400 kva) 220 to 480 Volts 50 or 60 Hz 1500 or 1800 RPM Generator Set Configurations Emissions/Fuel Strategy Low Fuel Consumption Engine Specifications Engine Model 3406C TA, I-6, 4-Stroke Water-Cooled Diesel Bore 137.2 mm 5.4 in Displacement 14.64 L 893.39 in3 Stroke 165.1 mm 6.5 in Compression Ratio 14.5:1 Aspiration TA Governor Type Hydra-mechanical Fuel System P&L SS-8428275-18321430-000 SS Page 1 of 8 Page: M-1 of M-5

Benefits And Features Cat Diesel Engine Reliable, rugged, durable design Field-proven in thousands of applications worldwide Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight Generator Matched to the performance and output characteristics of Cat engines Industry leading mechanical and electrical design Industry leading motor starting capabilities High Efficiency Cat EMCP Control Panel The EMCP controller features the reliability and durability you have come to expect from your Cat equipment. EMCP4 is a scalable control platform designed to ensure reliable generator set operation, providing extensive information about power output and engine operation. EMCP4 systems can be further customized to meet your needs through programming and expansion modules. Design Criteria The generator set accepts 100% rated load in one step per NFPA 110 and meets ISO 8528-5 transient response. UL 2200 / CSA - Optional UL 2200 listed packages CSA Certified Certain restrictions may apply. Consult with your Cat Dealer. Single-Source Supplier Fully prototype tested with certified torsional vibration analysis available World Wide Product Support Cat Dealers provide extensive post sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Cat SOSSM program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products. SS-8428275-18321430-000 SS Page 2 of 8 Page: M-2 of M-5

Standard Equipment Air Inlet Air Cleaner Cooling Package mounted radiator Exhaust Exhaust flange outlet Fuel Primary fuel filter with integral water separator Secondary fuel filter Fuel priming pump Generator Matched to the performance and output characteristics of Cat engines Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time IP23 Protection Power Termination Bus Bar Control Panel EMCP 4 Genset Controller Mounting Rubber vibration isolators Starting/Charging 24 volt starting motor Batteries General Paint - Caterpillar Yellow except rails and radiators gloss black SS-8428275-18321430-000 SS Page 3 of 8 Page: M-3 of M-5

Optional Equipment Exhaust Industrial, Residential, Critical Mufflers Generator Excitation: [ ] Permanent Magnet Excited (PM) [ ] Internally Excited (IE) Anti-condensation heater Oversize and premium generators Power Termination Circuit breakers, UL listed Circuit breakers, IEC compliant Control Panels EMCP (4.2) (4.3) (4.4) Local & remote annunciator modules Load share module Digital I/O module Remote monitoring software Starting/Charging Battery chargers Oversize batteries Jacket water heater Heavy-duty starting system Charging alternator General The following options are based on regional and product configuration: Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007 UL 2200 package EU Certificate of Conformance (CE) CSA Certification EEC Declaration of Conformity Narrow, Wide or Skid Base Sound attenuated, weather protective or high ambient weather protective enclosure Single or dual wall integral fuel tanks Single or dual wall sub-base fuel tanks Integral & sub-base UL listed dual wall fuel tanks Automatic transfer switches (ATS) SS-8428275-18321430-000 SS Page 4 of 8 Page: M-4 of M-5

The International System of Units (SI) is used in this publication. CAT, CATERPILLAR, their respective logos, ADEM, EUI, S O S, "Caterpillar Yellow" and the "Power Edge" trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission. SS-8428275-18321430-000 SS Page 5 of 8 Page: M-5 of M-5

ELECTRIC POWER - Technical Spec Sheet STANDARD 3406C 240 ekw/ 300 kva/ 50 Hz/ 1500 rpm/ 400 V/ 0.8 Power Factor Rating Type: STANDBY Fuel Strategy: LOW FUEL CONSUMPTION 3406C 240 ekw/ 300 kva 50 Hz/ 1500 rpm/ 400 V Image shown may not reflect actual configuration Metric English Package Performance Genset Power Rating with Fan @ 0.8 Power Factor 240 ekw Genset Power Rating 300 kva Aftercooler (Separate Circuit) 50.0 C 122.0 F Fuel Consumption 100% Load with Fan 69.4 L/hr 18.3 gal/hr 75% Load with Fan 53.9 L/hr 14.2 gal/hr 50% Load with Fan 38.5 L/hr 10.2 gal/hr 25% Load with Fan 24.6 L/hr 6.5 gal/hr Cooling System¹ Engine Coolant Capacity N/A N/A Inlet Air Combustion Air Inlet Flow Rate 17.7 m³/min 623.3 cfm Max. Allowable Combustion Air Inlet Temp 84 C 183 F Exhaust System Exhaust Stack Gas Temperature 578.8 C 1073.8 F Exhaust Gas Flow Rate 52.7 m³/min 1862.3 cfm Exhaust System Backpressure (Maximum Allowable) 6.7 kpa 27.0 in. water SS-8428275-18321430-000 SS Page 6 of 8 TSS-DM7523-01-GS-EPG-8428275.pdf Page 1 of 3

ELECTRIC POWER - Technical Spec Sheet STANDARD 3406C 240 ekw/ 300 kva/ 50 Hz/ 1500 rpm/ 400 V/ 0.8 Power Factor Rating Type: STANDBY Fuel Strategy: LOW FUEL CONSUMPTION Heat Rejection Heat Rejection to Jacket Water 159 kw 9017 Btu/min Heat Rejection to Exhaust (Total) 260 kw 14806 Btu/min Heat Rejection to Aftercooler 11 kw 635 Btu/min Heat Rejection to Atmosphere from Engine 52 kw 2938 Btu/min Heat Rejection to Atmosphere from Generator 19 kw 1058 Btu/min Alternator² Motor Starting Capability @ 30% Voltage Dip Current Frame Size Excitation Temperature Rise 586 skva 433 amps LC5014J SE 163 C Emissions (Nominal)³ NOx N/A N/A CO N/A N/A HC N/A N/A PM N/A N/A DEFINITIONS AND CONDITIONS 1. For ambient and altitude capabilities consult your Cat dealer. Air flow restriction (system) is added to existing restriction from factory. 2. UL 2200 Listed packages may have oversized generators with a different temperature rise and motor starting characteristics. Generator temperature rise is based on a 40 C ambient per NEMA MG1-32. 3. Emissions data measurement procedures are consistent with those described in EPA CFR 40 Part 89, Subpart D & E and ISO8178-1 for measuring HC, CO, PM, NOx. Data shown is based on steady state operating conditions of 77 F, 28.42 in HG and number 2 diesel fuel with 35 API and LHV of 18,390 btu/lb. The nominal emissions data shown is subject to instrumentation, measurement, facility and engine to engine variations. Emissions data is based on 100% load and thus cannot be used to compare to EPA regulations which use values based on a weighted cycle. SS-8428275-18321430-000 SS Page 7 of 8 TSS-DM7523-01-GS-EPG-8428275.pdf Page 2 of 3

ELECTRIC POWER - Technical Spec Sheet STANDARD 3406C 240 ekw/ 300 kva/ 50 Hz/ 1500 rpm/ 400 V/ 0.8 Power Factor Rating Type: STANDBY Fuel Strategy: LOW FUEL CONSUMPTION Applicable Codes and Standards: AS1359, CSA C22.2 No100-04, UL142,UL489, UL869, UL2200, NFPA37, NFPA70, NFPA99, NFPA110, IBC, IEC60034-1, ISO3046, ISO8528, NEMA MG1-22,NEMA MG1-33, 72/23/EEC, 98/37/EC, 2004/108/EC Note: Codes may not be available in all model configurations. Please consult your local Cat Dealer representative for availability. STANDBY:Output available with varying load for the duration of the interruption of the normal source power. Average power output is 70% of the standby power rating. Typical operation is 200 hours per year, with maximum expected usage of 500 hours per year. Ratings are based on SAE J1349 standard conditions. These ratings also apply at ISO3046 standard conditions Fuel Rates are based on fuel oil of 35º API [16º C (60º F)] gravity having an LHV of 42 780 kj/kg (18,390 Btu/lb) when used at 29º C (85º F) and weighing 838.9 g/liter (7.001 lbs/u.s. gal.). Additional ratings may be available for specific customer requirements, contact your Cat representative for details. For information regarding Low Sulfur fuel and Biodiesel capability, please consult your Cat dealer. www.cat-electricpower.com Performance No.: DM7523-01 Feature Code: 406DE2F Generator Arrangement: 2377184 Date: 06/10/2015 Source Country: CHINA The International System of Units (SI) is used in this publication. CAT, CATERPILLAR, their respective logos, ADEM, EUI, S O S, "Caterpillar Yellow" and the "Power Edge" trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission. SS-8428275-18321430-000 SS Page 8 of 8 TSS-DM7523-01-GS-EPG-8428275.pdf Page 3 of 3