Emergency lighting units LED series

Similar documents
Emergency lighting units EM series

Emergency lighting units EM powerled

Emergency lighting units EM powerled. EM powerled BASIC 4W Emergency lighting LED Driver

Emergency lighting units EM powerled

Emergency lighting units EM powerled

Emergency lighting units EM powerled

Emergency lighting units EM powerled

Emergency lighting units EM powerled

Emergency lighting units EM powerled

Emergency lighting units EM powerled

Emergency lighting units PC COMBO

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

Emergency lighting units EM converterled

Emergency lighting units EM powerled

Emergency lighting units EM powerled. EM powerled BASIC CLE Emergency lighting LED Driver

Emergency lighting units EM converterled

Emergency lighting units EM powerled

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units PC COMBO

Emergency lighting units EM series. EM PRO EZ-3, V PRO version

Emergency lighting units EM Inverter

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Emergency lighting units EM powerled. EM powerled BASIC 15 W CLE Emergency lighting units LED

Emergency lighting units EM series. EM BASIC lp-2, V BASIC version. Technical data. Ordering data. Article number

Emergency lighting units EM converterled

Emergency lighting units EM converterled

Emergency lighting units EM powerled. EM powerled BASIC 15 W CLE Emergency lighting LED Driver

Emergency lighting units EM powerled. EM powerled BASIC CLE Emergency lighting LED Driver

Emergency lighting units EM converterled

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

Emergency lighting units EM INVERTER

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version

Emergency lighting units EM series. EM BASIC, V BASIC version

Emergency lighting units EM powerled

Emergency lighting units EM INVERTER

EM BASIC V 50/60 Hz

Emergency lighting units EM powerled

Emergency lighting units EM LED Light Engines. EM ready2apply BASIC 1 2 W EM ready2apply

FL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC

Emergency lighting units EM LED Light Engines

Emergency lighting units EM LED Light Engines. Module EM-ES 08/10/12 Mk2 EM LED linear / area

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

Electronic ballasts for fluorescent lamps Professional electronic ballast

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

FL ballasts Electronic fixed output PC BASIC, 4 28 W PC BASIC

LED Driver Linear / area fixed output

LED light engine / OLED LED linear / area. Umodule STARK LLE-G CLASSIC EM STARK LLE

PC T8 TEC, W PC TEC

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

FL ballasts Electronic fixed output PC T8 TEC, W PC TEC T8

PC T8 PRO, W T8 fluorescent lamps

LED control gear Compact fixed output

Electronic ballasts for fluorescent lamps Multi-lamp ECG. PC T5 PRO-M lp, W T5, T8, compact (CFL) and T5c circular fluorescent lamps

FL ballasts Electronic fixed output. PC T5 TOP lp, W PC TOP T5

FL ballasts Electronic fixed output. PC TC PRO 1/2x9 70 W PC PRO compact

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Linear / area dimming

LED light engine / OLED LED linear / area. Module STARK LLE PREMIUM Modules LLE

FL ballasts Electronic fixed output

Emergency lighting units EM Batteries

FL ballasts Electronic fixed output

FL ballasts Electronic fixed output. PC TCL PRO, W PC PRO compact

PHASED OUT. LED light engine / OLED LED compact. Module CLE G2 190mm 1500lm ADV EM Modules CLE

LED light engine / OLED LED compact

TrustSight LED Emergency Lighting

EMERGENCY ONE-LED TM UNITY-LED TM LED MAINS/EMERGENCY DRIVER

PHASED OUT. LED light engine / OLED LED linear / area. Module LLE G3 16x140mm 325lm ADV, LLE G3 16x280mm 650lm ADV Modules LLE ADVANCED

LED light engines LED linear / area. Module STARK QLE G3 SELECT Modules QLE EXCITE

FL ballasts Electronic fixed output PC T8 PRO, W PC PRO T8

LED light engine / OLED LED compact. Umodule STARK CLE 360 CLASSIC EM STARK CLE

LED light engine / OLED LED compact. Umodule EOS P214-4 umodule EOS

EMERGENCY ONE-LED TM UNITY-LED TM LED MAINS/EMERGENCY DRIVER

LED light engine / OLED LED linear / area

PHASED OUT. LED light engine / OLED LED linear / area. Module QLE G1 488x239mm 2500lm ADV-SE Modules QLE

PHASED OUT. LED light engine / OLED LED compact. Module STARK CLE , CLE CLASSIC Modules CLE

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCD ECO, W Compact and T5c fluorescent lamps

PHASED OUT. LED light engine / OLED LED compact. Module STARK CLE CLASSIC / CLE CLASSIC Modules CLE

SLA DC. LED light engines ready2apply. Module SLA DC G2 50mm SNC Modules SLA ESSENCE

PHASED OUT. LED light engine / OLED LED linear / area. Umodule STARK LLE umodule LLE ADVANCED

TrustSight LED Emergency Lighting

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE

LED light engines LED linear / area

LED light engine / OLED LED compact

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

LED light engine / OLED LED linear / area. Umodule STARK LLE-G CLASSIC STARK LLE

EM converterled BASIC Installation and wiring instructions

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule STARK QLE CLASSIC EM umodule STARK QLE PHASED OUT. Ordering data.

Uengine COOL door for integration uengine COOL

Tunable White LED linear / area. Module LLE G2 PREMIUM LLE PREMIUM

LED light engines LED linear / area

LED light engines LED linear / area

LED modules LED linear / area

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

LED light engine / OLED LED linear / area. Module LLE PREMIUM CRI90 LLE PREMIUM

LED light engine / OLED LED linear / area

LED light engines LED linear / area

Transcription:

series EM power BASIC Emergency lighting supply units emergency lighting supply unit for manual testing Properties Mains and emergency operation Low-profile casing (21 x 30 mm cross-section) Constant current mode With either screw or clip fastening (clip-fix) 1, 2 or 3 h rated duration Selectable operating time (jumper) 1 or 2 W version Green charge status display Output power limitation Automatic restart after replacement Electronic multi-level charge system SELV classified (outputs power, battery, status, test ) Polarity reversal protection for battery Deep discharge protection Short-circuit-proof battery connection Emergency lighting s available Screw-fix Batteries High-temperature cells NiMH batteries Cs cells Blade terminals for simple connection Clip-fix without jumper position A È Standards, page 2 Wiring diagrams and installation examples, page 5 Screw-fix position B Clip-fix www.tridonic.com 1

series Technical data Rated supply voltage 220 240 V Mains frequency 50 / 60 Hz Mains current, 1 W device 30 ma Mains current, 2 W device 42 ma Power in mains operation, 1 W device 4 W Power in mains operation, 2 W device 6 W Maximum forward bias Vf 3.4 V Overvoltage protection 320 V (for 1 h) charging time 12 h Charge current, initial charge 125 ma Charge current, power charge 210 ma Charge current, trickle charge 50 ma discharge current See data sheet Leakage current (PE) < 0.5 ma Ambient temperature ta -25... +50 C Max. casing temperature tc 70 C Mains voltage changeover threshold according to EN 60598-2-22 Type of protection IP20 Protection class I Weight 0.073 kg Max. number of s Wattage Type Article number Screw fastening version 1 1.2 W EM power 1 W BASIC 89899858 2 2.0 W EM power 2 W BASIC 89899859 Clip fastening version 1 1.2 W EM power 1 W BASIC 89899865 2 2.0 W EM power 2 W BASIC 89899866 Packaging: 25 pieces/carton, 600 pieces/pallet Specific technical data Type current in emergency operation current in mains operation Number of cells / jumper 1 x 2 x 1 x 2 x 1 h / removed 2 h / position A 3 h / position B EM power 1 W BASIC 350 ma 350 ma 2 3 3 EM power 2 W BASIC 600 ma 350 ma 350 ma 350 ma 3 4 5 www.tridonic.com 2

series ACCES- SORIES Test EM2 For connection to the emergency lighting unit For checking the device function Type Article number Test EM 2 89805277 Packaging: 25 pieces/bag, 200 pieces/carton ACCES- SORIES Status indication green A green indicates that charging current is flowing into the battery Type Article number EM green 89899605 EM green, ultra high brightness 89899756 Packaging: 25 pieces/bag, 200 pieces/carton www.tridonic.com 3

series Standards ENEC CE gemäß EN 60598-2-22 gemäß EN 50172 Further technical data discharge current 1 W 2 W 1 1 2 1 h 790 ma 850 ma 830 ma 2 h 440 ma 610 ma 600 ma 3 h 440 ma 480 ma 480 ma The EM power has a unique power regulation circuit; this is designed to limit the total power drawn from the battery in the event of using s with excessively high forward voltages (Vf). In such cases the unit will reduce the current in order to maintain an acceptable drain current from the battery and hence meet the required duration time. This feature enables the EM power to have minimum battery count for a given range of s. Mechanical details Case manufactured from polycarbonate. status indicator Green Mounting hole 6.5 mm dia Lead length 1000 mm Test Mounting hole 7.0 mm dia Lead length 550 mm leads Quantity: 1 red and 1 black Length: 1 m Wire type: 0.5 mm 2 solid conductor Insulation rating: 90 C end termination Push on 4.8 mm receptacle to suit battery spade fitted with insulating cover Module end termination 8.0 mm stripped insulation Two-piece batteries are supplied with a 200 mm lead with 4.8 mm receptacles at each end and insulating covers to connect the separate sticks together. At a low charge state of the battery (<1.5 V at the 1 W driver and <3 V at the 2 W driver) the will not be driven in maintained mode via the ed line until the rated battery voltage levels are exceeded. Technical data Accu-NiMh case temperature range to ensure 4 years design life 0 C to +45 C storage life in temperate conditions 4 years battery voltage 1.2 V per cell capacity Cs 2.0 Ah Recommended fixing details for clip fixing 125,2 0,4 mm to 0,6 mm thick gear tray 122,4 0,6 mm to 1,1 mm thick gear tray Link positions for duration and cell count fixing slots 4,3 x 9,3 mm Storage Batteries should be stored within the specified temperature range in low humidity conditions. Optimal storage conditions are temperature: +5 C to +25 C humidity: 65 % ±20 % Avoid atmosphere with corrosive gas It is recommended to disconnect the battery before store or delivery Avoid to store the batteries discharged A long term storage in open circuit leads to battery self discharge and deactivation of chemical components. It could be required to charge and discharge the batteries a few times to recover the initial performance. Duration 1 hr 2 hr Link Position without jumper position A 1 W Power 2 W Power 2 cell 4 cell Service life Average service life 50,000 hours under rated conditions with a failure rate of less than 10 %. Average failure rate of 0.2 % per 1000 operating hours. Batteries Connection method: 4.8 x 0.5 mm spade tag welded to end of cell For stick packs this connection is accessible after the battery caps have been fitted. To inhibit inverter operation disconnect the batteries by removing the connector from the battery spade tag. For battery data see separate data sheet. 3 hr position B 5 cell Jumper selection Module supplied with jumper in 3 hours position (position B). The position of the link will only be read on first power up. If it is changed afterwards both the battery and mains supply must be disconnected for 10 seconds to enable the EM power to read the new link position on reconnection of the battery and mains. It will lead to a false battery failure indication if the link is changed after installation without this reset. www.tridonic.com 4

series Wiring type and cross section The wiring can be in flexible cable or solid. Strip 8.5 9.5 mm of insulation from the cables to ensure perfect operation of the push-wire terminals. Wiring mains (SL, N, L) ( +, ) wire preparation: 0.5 1.5 8.5 9.5 mm Maximum lead length status indication batteries 3 m 1 m 1 m Wiring batteries (Bat +, Bat ) test () status indication (status K, A) wire preparation: Ø 0.6 0.8 8.5 9.5 mm Max. lead insulation diameter Test Indicator Release of the wiring Press down the push button and remove the cable from front. Wiring diagram Wiring diagram for one or two in series Line in from Neutral Permanent line SL N L EM power BASIC status K status A + Bat Bat + pink orange Optional Test Switch + + Wiring diagram for multiple (3 12) in parallel Line in from Neutral Permanent line SL N L EM power BASIC status K status A + Bat Bat + pink orange Optional Test Switch + + + + Take care that the is connected with the right polarity. that are connected to the EM power devices should have a reverse polartity protection device such as a schottky diodes fitted, otherwise irreversible damage could occur if the is connected in reverse polarity. Any protection device must be capaple of handling in excess of 700 ma. Note: The Tridonic Emergency- is therefore fitted with a protection diode across the power. Wiring instructions The power terminals, battery, indicator and test terminals are classified as SELV. Keep the wiring of the input terminals separated from the wiring of the SELV equivalent terminals or consider special wiring (double insulation, 6 mm creepage and clearance) when these connections should be kept SELV. The output to the is DC but has high frequency content at 125 khz, which should be considered for good EMC compliance. power leads should be separated from the mains connections and wiring for good EMC performance. Maximum lead length on the power terminals is 3 m. For a good EMC performance keep the wiring as short as possible. Maximum lead length for the Test and Indicator connection is 1 m. The test and Indicator wiring should be separated from the power- leads to prevent noise coupling. leads are specified with 0.8 mm cross section and a length of < 1 m Switched live and uned live supplies must be off the same phase. i For comprehensive instructions consult the Tridonic website www.tridonic.com www.tridonic.com 5