Emergency lighting units EM powerled. EM powerled BASIC 15 W CLE Emergency lighting LED Driver

Similar documents
Emergency lighting units EM powerled. EM powerled BASIC CLE Emergency lighting LED Driver

Emergency lighting units EM powerled. EM powerled BASIC 15 W CLE Emergency lighting units LED

Emergency lighting units EM powerled. EM powerled BASIC CLE Emergency lighting LED Driver

Emergency lighting units EM powerled

Emergency lighting units EM powerled

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

Emergency lighting units EM powerled. EM powerled BASIC 4W Emergency lighting LED Driver

Emergency lighting units EM powerled

Emergency lighting units EM powerled

Emergency lighting units EM converterled

Emergency lighting units EM converterled

Emergency lighting units EM powerled

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM powerled

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Emergency lighting units EM powerled

Emergency lighting units EM powerled

Emergency lighting units EM series. EM BASIC lp-2, V BASIC version. Technical data. Ordering data. Article number

Emergency lighting units EM powerled

Emergency lighting units EM converterled

Emergency lighting units EM Inverter

Emergency lighting units LED series

Emergency lighting units EM converterled

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

Emergency lighting units EM series. EM BASIC, V BASIC version

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

Emergency lighting units EM converterled

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version

Emergency lighting units EM series. EM PRO EZ-3, V PRO version

Emergency lighting units EM series

Emergency lighting units EM powerled

Emergency lighting units EM INVERTER

Emergency lighting units PC COMBO

Emergency lighting units EM powerled

Emergency lighting units PC COMBO

Emergency lighting units EM LED Light Engines. EM ready2apply BASIC 1 2 W EM ready2apply

Emergency lighting units EM INVERTER

Emergency lighting units EM LED Light Engines

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

LED control gear Compact fixed output

LED Driver Linear / area fixed output

LED light engine / OLED LED compact. Umodule STARK CLE 360 CLASSIC EM STARK CLE

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE

EM BASIC V 50/60 Hz

PC T8 TEC, W PC TEC

Emergency lighting units EM powerled

FL ballasts Electronic fixed output PC T8 TEC, W PC TEC T8

FL ballasts Electronic fixed output. PC T5 TOP lp, W PC TOP T5

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

LED Driver Linear / area dimming

FL ballasts Electronic fixed output. PC TCL PRO, W PC PRO compact

LED Driver Compact fixed output

LED Driver Compact fixed output

FL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC

FL ballasts Electronic fixed output PC BASIC, 4 28 W PC BASIC

FL ballasts Electronic fixed output. PC TC PRO 1/2x9 70 W PC PRO compact

FL ballasts Electronic fixed output

Electronic ballasts for fluorescent lamps Professional electronic ballast

FL ballasts Electronic fixed output

FL ballasts Electronic fixed output PC T8 PRO, W PC PRO T8

Table of contents NLE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h 4

PC T8 PRO, W T8 fluorescent lamps

Electronic ballasts for fluorescent lamps Multi-lamp ECG. PC T5 PRO-M lp, W T5, T8, compact (CFL) and T5c circular fluorescent lamps

SLA DC. LED light engines ready2apply. Module SLA DC G2 50mm SNC Modules SLA ESSENCE

TrustSight LED Emergency Lighting

LED light engine / OLED LED linear / area. Module STARK LLE PREMIUM Modules LLE

LED light engine / OLED LED linear / area. Umodule STARK LLE-G CLASSIC STARK LLE

TrustSight LED Emergency Lighting

EM converterled BASIC Installation and wiring instructions

PHASED OUT. LED light engine / OLED LED linear / area. Umodule STARK LLE umodule LLE ADVANCED

Driver LC 17W mA flexc C EXC EXCITE series

PHASED OUT. LED light engine / OLED LED compact. Module STARK CLE , CLE CLASSIC Modules CLE

LED light engines LED linear / area. Module STARK QLE G3 SELECT Modules QLE EXCITE

LED light engines ready2apply. Engine SLA AC G2 50mm SNC Engine SLA ESSENCE

PHASED OUT. LED light engine / OLED LED compact. Module STARK CLE CLASSIC / CLE CLASSIC Modules CLE

Tunable White LED linear / area

LED light engine / OLED LED linear / area. Umodule STARK LLE-G CLASSIC EM STARK LLE

Emergency lighting units EM LED Light Engines. Module EM-ES 08/10/12 Mk2 EM LED linear / area

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule STARK QLE CLASSIC EM umodule STARK QLE PHASED OUT. Ordering data.

PHASED OUT. LED / OLED Light Engine LED linear / area. Umodule STARK LLE STARK LLE

LED light engine / OLED LED compact

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCD ECO, W Compact and T5c fluorescent lamps

LED Emergency Lighting

PHASED OUT. LED light engine / OLED LED compact. Module CLE G2 190mm 1500lm ADV EM Modules CLE

LED light engine / OLED LED compact

PHASED OUT. LED light engine / OLED LED linear / area. Module LLE G3 16x140mm 325lm ADV, LLE G3 16x280mm 650lm ADV Modules LLE ADVANCED

LED light engines LED linear / area

LED light engine / OLED LED linear / area

PHASED OUT. LED light engine / OLED LED linear / area. Module QLE G1 488x239mm 2500lm ADV-SE Modules QLE

ELEMENT. Product family datasheet. Constant Voltage Non dimmable

Emergency lighting units EM Batteries

LED modules LED linear / area

ROBUST LED DRIVERS. EasyLine Industry. EasyLine INDUSTRY , , , , , , ,

LED light engine / OLED LED linear / area. Module LLE PREMIUM CRI90 LLE PREMIUM

U LED modules, converters and systems SIGNAGE. Uengine IMAGE SELECT

LED light engine / OLED LED linear / area

Transcription:

E BASIC 15 W CE lighting ED Driver roduct description ED Driver for mains operation with integrated Simple CRRIDR FUCTI () and emergency lighting function for manual testing For luminaire installation For the use with STARK CE 1500 5 years guarantee roperties Constant current ED Driver with 470 ma output current Simple CRRIDR FUCTI () with 10 % light level Integrated 1 W emergency lighting unit for nonmaintained operation 3 h rated duration Constant current mode Green charge status display ED Electronic charge system olarity reversal protection for battery Deep discharge protection Shortcircuitproof battery connection SEV lighting EDs available ED module and sensor available Batteries Hightemperature cells imh / icd batteries Cs cells Blade terminals for simple connection 4year design life 1year guarantee È roduct matrix, page 4 Wiring diagrams and installation examples, page 6 66,5 79 Technical data Rated supply voltage 220 240 V Mains frequency 50 / 60 Hz Mains power in normal operation 18 W Mains power in operation 3.5 W Mains current in normal operation 0.11 A Mains current in operation 0.03 A Typ. λ (at 230 V 50 Hz, normal operation) 0.8 Typ. λ (at 230 V 50 Hz, operation) 0.5 Typ. efficiency (at 230 V 50 Hz, normal operation) 82 % Typ. efficiency (bei 230 V 50 Hz, operation) 49 % eakage current (E) 0 vervoltage protection 320 V (for 1 h) charging time 24 h charge current 120 ma discharge current see page 4 umber of cells 3 Max. permitted forward voltage ED 33 V Max. permitted forward voltage emergency ED 1 3.4 V Turn on time (at 230 V, 50 Hz, full load) 100 ms Ambient temperature ta 0... 55 C Max. casing temperature tc 75 C Dimensions xbxh 123 x 79 x 31 mm Mains voltage changeover threshold according to E 60598222 of protection I20 rdering data Article number carton pallet Weight per pc. 15W BASIC CE imh 89800174 10 pc(s). 560 pc(s). 0.126 kg 15W BASIC CE icd 89800176 10 pc(s). 560 pc(s). 0.125 kg Data sheet 09/150208 www.tridonic.com 1

Specific technical data Typ. output current utput current tolerance utput voltage range 1 Typ. output power ormal operation 15W BASIC CE imh 470 ma 5 % 22 33 V 14.25 W 15W BASIC CE icd 470 ma 5 % 22 33 V 14.25 W operation 15W BASIC CE imh 43 ma 15 % 22 33 V 1.12 W 15W BASIC CE icd 43 ma 15 % 22 33 V 1.12 W operation 15W BASIC CE imh 400 ma 5 % 2.5 3.4 V 1.32 W 15W BASIC CE icd 320 ma 5 % 2.5 3.4 V 1.06 W 1 The use of the emergency ED with a higher forward voltage then 3.4 V reduces the operating time. Typ. output voltage = 30 V Data sheet 09/150208 www.tridonic.com 2

ACCES SRIES Status indication green ED roduct description A green ED indicates that charging current is flowing into the battery rdering data Article number bag carton Weight per pc. ED green 89899605 25 pc(s). 200 pc(s). 0.011 kg ED green, ultra high brightness 89899756 25 pc(s). 800 pc(s). 0.012 kg roduct description Motion detector for luminaire installation Motion detection through glass and thin materials (except metal) For automatic on/off switching of electronic ballasts with corridor FUCTI Brightut function: luminaire is not switched on if there is adequate brightness Delay time, detection range and light value for the Brightut function can be set via 3 potentiometers Max. installation height 5 m Infinitely variable range (0.5 5.0 m) ACCES SRIES SWITCH Sensor HF 5B Automatic switching based on motion and light level rdering data Article number carton Weight per pc. SWITCH Sensor HF 5B 28000086 4 pc(s). 0,079 kg Data sheet 09/150208 www.tridonic.com 3

Standards E 55015 E 6100032 E 6100033 E 613471 E 61347213 E 61547 E 62384 according to E 60598222 according to E 50172 E 6134727 Further technical data discharge current Max. ED forward voltage (3,40 V) 15 W CE imh 500 ma 15 W CE icd 375 ma Technical data batteries AccuiCd Case temperature range to ensure 4 years design life 1.6 Ah Cs 5 C bis 50 C voltage/cell 1.2 V Capacity Cs 1.6 Ah Max. short term temperature (reduced lifetime) 70 C Max. number discharge cycles acking quantity 4 cycles per year plus 4 cycles during comissioning 5 pcs. per carton AccuiMh Case temperature range to ensure 4 years design life 2.0 Ah Cs 5 C to 55 C voltage 1.2 V Capacity 2.0 Ah Max. short term temperature (reduced lifetime) 70 C Max. number discharge cycles acking quantity 4 cycles per year plus 4 cycles during comissioning 5 pcs. per carton Storage of batteries Store batteries within the specified temperature range in low humidity conditions. ptimal storage conditions are: temperature: 5... 25 C humidity: 65 % ±5 % Avoid atmosphere with corrosive gas Disconnect batteries before store or delivery Avoid storage of discharged batteries A long term storage in open circuit leads to battery self discharge and deactivation of chemical components. It could be required to charge and discharge the batteries a few times to recover the initial performance. Batteries Connection method: 4.8 x 0.5 mm spade tag welded to end of cell For stick packs this connection is accessible after the battery caps have been fitted. To inhibit inverter operation disconnect the batteries by removing the connector from the battery spade tag. For battery data see separate data sheet. Mechanichal details Case manufactured from polycarbonate. Glowwire test according to E 605981 650 C and 850 C passed ED status indicator Green Mounting hole 6.5 mm dia ead length 1,000 mm leads Quantity: 1 red and 1 black ength: 1,000 mm Wire type: 0.5 mm 2 solid conductor Insulation rating: 90 C end termination ush on 4.8 mm receptacle to suit battery spade fitted with insulating cover Module end termination 8.0 mm stripped insulation selection 15 BASIC CE 15 BASIC CE imh 15 BASIC CE icd Technology and capacity icd 1.6 Ah Cscells icd 1.6 Ah CsCells imh 2 Ah CsCells Design umber of cells Article no. 89800174 89800176 Article no. Assignable batteries stick 1 x 3 AccuiCd C 3A 89899743 battery pack 3 ackicd 3C 89899676 stick 1 x 3 AccuiMH C 3A 89899744 Data sheet 09/150208 www.tridonic.com 4

Shortcircuit behaviour In case of a short circuit on the secondary side (ED) the ED ouput is switched off. After elimination of the short circuit the nominal operation is restored automatically. oload operation The ED Driver is not damaged in the noload operation. The max. output voltage can be obtained during noload operation. Expected lifetime ta = 45 C ta = 55 C 15W BASIC CE imh tc 65 C 75 C ifetime 100,000 h 50,000 h 15 W BASIC CE icd tc 65 C 75 C ifetime 100,000 h 50,000 h Storage conditions Humidity: 5 % up to max. 85 %, not condensed (max. 56 days/year at 85 %) Storage temperature: 40 C up to max. 80 C The devices have to be within the specified temperature range (ta) before they are operated. Maximum loading of automatic circuit breakers Automatic circuit breaker type B10 B13 B16 B20 Inrush current Installation Ø 1.5 mm 2 1.5 mm 2 1.5 mm 2 2.5 mm 2 I max time 15W BASIC CE imh 90 130 130 130 10 A 120 μs 15 W BASIC CE icd 90 130 130 130 10 A 120 μs Harmonic distortion in the mains supply (at 230 V / 50 Hz and full load) in % THD 3 5 7 15W BASIC CE imh 39 33 20 12 15 W BASIC CE icd 39 33 20 12 Ballast lumen factor in % BF EBF Corridor mode 15W BASIC CE imh 10 9.5 10 15 W BASIC CE icd 8 7.7 10 Data sheet 09/150208 www.tridonic.com 5

Wiring diagram with sensor Wiring diagram with sensor and testswitch Test switch* S IR input 15 W BASIC CE Indication ED ED ED STARK CE S IR input 15 W BASIC CE Indication ED ED ED STARK CE Sensor Sensor IR input 230 V * Use 230 V Test switch Switching behaviour S ED off off off off on off on off 10 % on on 100 % Wiring diagram Wiring diagram with testswitch Test switch* S IR input 15 BASIC CE Indication ED ED ED STARK CE S IR input 15 BASIC CE Indication ED ED ED STARK CE IR input 230 V The mains power must be removed before changing the ED load. Secondary switching of EDs is not allowed and may cause damage to the EDs. The hot plugin of EDs during normal operation may result in current peaks of up to 50% above the typical output current. * Use 230 V Test switch ote for manually tested emergency lighting with combined ED modules: For manually tested emergency applications when used with combined ED light modules for general and emergency lighting (e. g. modules STARK QE, STARK E24, STARK CE and t Spot 3xx) it is important that the normal supply of the mains ED Driver together with the permanent emergency supply is switched off prior to checking the operation of the emergency EDs. These combined ED modules use independent circuits for general an d emergency lighting. If this is not done, it may not be possible to see that the emergency EDs are operating. Use a similar circuit to that shown above. Data sheet 09/150208 www.tridonic.com 6

Wiring instructions Secondary leads should be separated from the mains connections and wiring for good C performance. The powered terminals, battery and indicator ED terminals are classified as SEV. Keep the wiring of the input terminals separated from the wiring of the SEV equivalent terminals or consider special wiring (double insulation, 6 mm creepage and clearance) when these connections should be kept SEV. Maximum lead length on the powered terminals is 3 m. For a good C performance keep the ED wiring as short as possible. Maximum lead length for the indicator ED connection is 1 m. The indicator ED wiring should be separated from the powered leads to prevent noise coupling. leads are specified with 0.8 mm cross section and a length of < 1 m Switched live and unswitched live supplies must be off the same phase. IDC interface solid wire with a cross section of 0.5 mm² according to the specification from WAG Horizontal interface solid wire with a cross section of 0.5 1.5 mm² according to the specification from WAG strip 7.5 8.5 mm of insulation from the cables to ensure perfect operation of the terminals wire preparation: 0.5 1.5 mm² 7.5 8.5 mm oosen wire Installation instruction Max. torque for the mounting screws: 0.5 m / M4. You must make sure that the ED is connected with the correct polarity. EDs that are connected to should have polarity reversal protection such as a Schottky diode. There may be irreversible damage if the ED is connected with the wrong polarity. The protection device must be capable of handling a load of more than 700 ma. Additional information Additional technical information at www.tridonic.com Technical Data Guarantee conditions at www.tridonic.com Services o warranty if device was opened. Data sheet 09/150208 www.tridonic.com 7