Max 5 I/min - bar Featuring prefiltration by means of a magnetic column Extended element life time AN INNOVATIVE GREEN FILTER FEATURING LEIF LEIF The TTF Series features pre-filtration by means of a magnet column and a quick response bypass with low hysteresis. Maximum pressure bar. Maximum flow 5 l/min. A second return port is an available option as is a filling port in the filter cover. Contact Information: European Product Information Centre Freephone: 8 27 27 5374 (from AT, BE, CH, CZ, DE, EE, ES, FI, FR, IE, IT, PT, SE, SK, UK) filtrationinfo@parker.com Product Features: TTF features pre-filtration by means of a magnet column. Quick response bypass with low hysteresis. Maximum pressure bar. Maximum flow 5 l/min. Options include a filling port in the filter cover and second return port. Patented LEIF elements safeguard filtration quality. Flow from inside to out. www.parker.com/hfde 2 FDHB5UK/ETF FDHB5UK/TTF Geeve Hydraulics 26 Catalog 26 Hydraulic and Heavy Duty Filtration & Contamination Control 2
Features & Benefits Features bar rated filter Cast aluminium head LEIF elements Magnetic pre-filtration In-to-Out filtration High level of customisation Quick response bypass with low hysteresis Standard or customised funnel Advantages Can be utilised for severe return line applications Compact profile, lightweight and durable Element safeguards the use of genuine parts Removes ferrous particles, even during bypass conditions All captured contamination retains inside the element Dedicated system-matched solutions can be easily made available Reduction of bypass period due to low hysteresis Only a small part of the total flow is bypassing the element Ensures that oil enters the tank under the oil level Benefits Reduced downtime due to premature filter failures Less weight, smaller envelop and cleaner appearance Guaranteed quality of filtration Contributes to ISO 4 certification Improved fluid cleanliness levels Extended element life time No recontamination of system during change of elements Improved integration of filter in system combined with lower initial system costs Improved protection of system Significant reduction of oil foaming Typical Applications Waste management trucks Mobile cranes Power packs Wheeled loaders Drilling equipment The Parker Filtration TTF Series Return Line Filters TTF tank top mounted return line filters feature pre-filtration by means of a magnet column and a quick response bypass with low hysteresis. Thanks to the In-to-Out filter principle, contaminated oil cannot leak back into the system. TTF filters are available in versions capable of handling flow rates up to 5 l/min. They can operate up to a maximum working pressure of bar. Optional filling port in filter cover, second return port and customised diffusers can be specified. 22 FDHB5UK/TTF 22 Geeve Hydraulics 26 Catalog 26 Hydraulic and Heavy Duty Filtration & Contamination Control
Specification Operation pressure: Max. bar. Assembly: Tank top mounted. Connections: Threaded BSP ports. Flanged ports on request. Filter housing: Aluminium head and cover. Seal material:, fluoroelastomer, neoprene. Operation temperature range: Seal material : -4 to + C. Seal material Fluoroelastomer: -2 to +2 C. Bypass setting Opening pressure.8 /.5 or 2 bar. Other settings on request. Degree of filtration: Determined by multipass test according to ISO 6889. Flow fatigue characteristics: Filter media is supported so that the optimum fatigue life is achieved. Filtration media: Microglass III and Ecoglass III for LEIF elements. Also available µm cellulose and 4µm stainless steel mesh. Element burst rating: bar (ISO 294) Pressure indicator options: Setting.7 or.2 bar. Other settings on request. Visual pressure gauge. Electrical pressure switch. Options: Diffuser type P (straight pipe, no perforated plate area) (with closed diffuser end cap and with perforated plate area, recommended when oil entry in reservoir is close to the reservoir bottom or to ensure oil entry under the reservoir oil level) Magnetic pack: Standard. TTF4 and 5 are standard supplied without magnets Filling port in cover: (optional). Filter element: LEIF element with reusable metal element sleeve. Optional conventional style element with steel end caps. The LEIF element is patented and safeguards the use of genuine parts. Note: LEIF element can be used with mineral and HEES type oils. For other fluids consult Parker Filtration. LEIF contributes to ISO 4 quality standards. TTF 9a 9b 3 4 5 6 7 8 2 3 TTF sealkit: No. 4+7+2 Ref. No. Description 4 Flange nut 3 Cover 4 Cover-seal 5 Top-spring 6 Insert 7 Insert-seal 8 Element 9a - Indicator 9b -3 Plug Mx -3 Unit-ring Housing 2 Gasket 3 Sleeve 4 Funnel/diffuser 5 O-ring 6 Bypass set 4 5 6 23 FDHB5UK. FDHB5UK/EFT FDHB5UK/TTF Geeve Hydraulics 26 Catalog 26 Hydraulic and Heavy Duty Filtration & Contamination Control 23
MAX 5 I/min - bar TTF Lengths 2-5 Single port TTF length Type 2 TTF -6 3 TTF -9 4 TTF -2 5 TTF -5 Dimensions in mm Port option h h ØD ØD H H2 H3 b R R R2 K FP 3 9 9 75 9 9 G 3 /4, G 28 73 Ø9 Ø93 68 6 63 4xØ9 225 33 33 325 42 42 G /2 TTF Lengths 6- Single port TTF length Type 6 TTF 2-7 7 TTF 2-23 8 TTF 2-3 9 TTF 2-4 TTF 2-5 Dimensions in mm Port option h h ØD ØD H H2 H3 b R R R2 K FP 223 35 33 35 G¼, G½ 36 92 Ø32 Ø36 58 5 523 525 563 575 35 35 5 9 83 87.5 2 4xØ G¾ 525 575 24 FDHB5UK/TTF FDHB5UK/ETF 24 Geeve Hydraulics 26 Catalog 26 Hydraulic and Heavy Duty Filtration & Contamination Control
TTF Lengths 2-5 Dual port H2 H TTF length 2 3 4 4A 5 4B Type TTF -6 TTF -9 TTF -2 TTF -4 TTF -5 TTF -75 Port option A - B h h ØD ØD H H2 b R R R2 K FP 3 9 75 7 G - G 3 74 Ø88 Ø9 225 22 285 28 325 32 376 37 9 83 87.5 2 4xØ G /8 Dimensions in mm TTF Lengths 6- Dual port TTF length Type 6 TTF 2-7 7 TTF 2-23 8 TTF 2-3 9** TTF 2-4 ** TTF 2-5 Dimensions in mm Dual Port option A-B h h ØD ØD H H2 H3 R R R2 K FP 223 38 G /2 - G /2 G2 - G /2 SAE /2 - G /2 46 7 Ø32 Ø36 33 58 523 38 538 538 563 578 38 38 538 83 87.5 2 4xØ G 538 578 25 FDHB5UK/ETF FDHB5UK/TTF Geeve Hydraulics 26 Catalog 26 Hydraulic and Heavy Duty Filtration & Contamination Control 25
Pressure Drop Curves The recommended level of the initial pressure drop for low pressure filters is max.5 bar. If the medium used has a viscosity different from 32cSt, pressure drop over the filter can be estimated as follows: Dp = (Dp32 x viscosity of medium used) / 32cSt. TTF6 (Element length code 2) TTF9 (Element length code 3) 5 6 2 26 2 29 2Q.5 2.8.4.2 8 6 24 2Q 3 39 2.3 7.4 4.5 4.5 5Q Q.5 7.3 2Q 2 4 6 8.8.6.4 5Q Q.2 2Q 3 6 9 2 5.6 TTF2 (Element length code 4) TTF5 (Element length code 5) 8 6 24 3 39 47.4 2.3 2Q.2 7.4.4 6 3.2 47 2.3 2Q 7.4 4.5 4.5.8.6.4.2 5Q Q 2Q 3 6 9 2 5 8.6.8.6.6 5Q.4 Q.2 2Q 6 2 8 26 FDHB5UK/TTF FDHB5UK/ETF 26 Geeve Hydraulics 26 Catalog 26 Hydraulic and Heavy Duty Filtration & Contamination Control
Pressure Drop Curves (cont.) The recommended level of the initial pressure drop for low pressure filters is max.5 bar. If the medium used has a viscosity different from 32cSt, pressure drop over the filter can be estimated as follows: Dp = (Dp32 x viscosity of medium used) / 32cSt. TTF7 (Element length code 6) TTF23 (Element length code 7) 2.5 3 26 39 53 66 79 93 36.3 2.5 2Q 29 2.8 4.5 5Q.5 Q 7.3 2Q 5 5 2 25 3 35 TTF3 (Element length code 8) 3 26 39 53 66 79 92 6 9 4.5.9 2Q 3. 5Q.8.6.7.2.6.5 7.3 Q.4.3 4.4.2 2Q..5 5 5 2 25 3 35 4 45 TTF4 (Element length code 9).6 3 26 39 53 66 79 92 6 9 32 23.2.4 2Q 2.3.2 7.4 4.5.8.6 5Q.6.4.2 2Q Q 5 5 2 25 3 35 4 45 5 TTF5 (Element length code ).8 3 26 39 53 66 79 92 6 9 32 45 26..6 23.2.4 2Q 2.3.2 7.4 4.5.8.6 5Q.6.4.2 Q 2Q 5 5 2 25 3 35 4 45 5 55 3 26 39 53 66 79 92 6 9 32 45 59.6 23.2 2Q.4 2.3.2 7.4.8.6.4.2 5Q 2Q 4.5.6 Q 5 5 2 25 3 35 4 45 5 55 6 27 FDHB5UK/ETF FDHB5UK/TTF Geeve Hydraulics 26 Catalog 26 Hydraulic and Heavy Duty Filtration & Contamination Control 27
Pressure Drop Curves (cont.) TTF6 (Element length code 2) 4 8 2 6 2 24.2.74 TTF9 (Element length code 3) 8 6 24 3.2.74..8.6.4.2 C 4W.45.6.87.58.29..8.6.4.2 C 4W.45.6.87.58.29 5 3 45 6 75 9 TTF2 (Element length code 4) 3 6 9 2 TTF5 (Element length code 5) 8 6 24 3 39 47 56.4 2.3 C.2.74.2 8 6 24 3 39.74..45..8.6.4.2 4W.45.6.87.58.29.8.6.4.2 C 4W.6.87.58.29 3 6 9 2 5 8 2 3 6 9 2 5 TTF7 (Element length code 6) TTF23 (Element length code 7) 8 6 24 3 39 47 56.2.74 3 26 39 53 66 79.4 2.3..8.6.4 C 4W.45.6.87.58.2..8.6.4 C 4W.74.45.6.87.58.2.29.2.29 3 6 9 2 5 8 2 5 5 2 25 3 TTF3 (Element length code 8) 3 26 39 53 66 79 92 6.4 2.3.2. C.74.45.8.6.4.6.87 4W.58.2.29 5 5 2 25 3 35 4 28 FDHB5UK/TTF FDHB5UK/ETF 28 Geeve Hydraulics 26 Catalog 26 Hydraulic and Heavy Duty Filtration & Contamination Control
Indicator Options Indicator PS pressure switch Protective cap with dual cable duct for, 7-2, 3mm diameter cable Indicator PS NO/NC pressure switch Protective cover Normally open contacts 75 Amp 6.3x8 terminals 2 4 Switch 24 A/F 9 74 Normally closed contacts 58 27 A/F = COM. 2 = N.C. 4 = N.O. 9 55 Mx G /8 (BSP) Ø3.5 Ø28 Elec.rating Thread connection Elec.connection Protection TTF Specifications 42V / 4A Mx AMP 6.3x.8 terminals + protective cap IP65 (with cap) terminals IP FMUSEBMML (Switch) Indicator Connection / Filter Head Matrix Port(s) Filter head ISO 228-G 3 /4" (BSP) (TTF length 2,3,4 and 5) ISO 228-G" (BSP) ISO 228-G /4" (BSP) (TTF length 6 and larger) 2xISO 228-G /4" (BSP) (TTF length 6 and larger) ISO 228-G /2"(BSP) (TTF length 6 and larger) 2xISO 228-G /2"(BSP) (TTF length 6 and larger) /2" SAE-3 PSI (TTF length 6 and larger) /2" SAE-3 PSI (2nd port) + G /2" (TTF length 6 and larger) G2" (TTF length 6 and larger) G2" + G /2" (TTF length 6 and larger) Indicator Thread M M M G/8" M G/8" G/8" G/8" G/8" G/8" Specifications Elec.rating 42V / 2A Thread connection G /8 Elec.connection AMP terminal 6.3x.8 Protection IP65 (terminal IP) Switch type NO or NC FMUS2EBMG2L (NO switch) FMUS3EBMG2L (NC switch) Visual indicator.2 bar M: code FMUGEBPML G /8: code FMUG2EBPG2L Ordering Information Standard products table Part number Supersedes TTF3QLBP2EG2 TTF9-G 3 /4 TXWL3- B5 MM TTF32QLBP2EG2 TTF9-G 3 /4 TXWL3-2 B5 MM TTF5QLBP2EG6 TTF25-G TXWL3E- B5 MM TTF52QLBP2EG6 TTF25-G TXWL3E-2 B5 MM TTF6QLBP2EG23 TTF7-G /4 TXWL4- T B5 MM TTF62QLBP2EG23 TTF7-G /4 TXWL4-2 T B5 MM TTF8QLBP2EG243 TTF3-G /2 TXWL5A- T B5 MM TTF82QLBP2EG243 TTF3-G /2 TXWL5A-2 T B5 MM TTFQLBP2EG24A TTF5-G /2 TXWL5C- T B5 MM NMG TTF2QLBP2EG24A TTF5-G /2 TXWL5C-2 T B5 MM NMG Flow (l/min) 9 9 25 25 7 7 3 3 5 5 Model number Element length TTF9 Length 3 TTF9 Length 3 TTF25 Length 5 TTF25 Length 5 TTF7 Length 6 TTF7 Length 6 TTF3 Length 8 TTF3 Length 8 TTF5 Length TTF5 Length Media rating (µ) Note: Filter assemblies ordered from the product configurator on the next page are on extended lead times. Where possible, please make your selection from the table above. 2 2 2 2 2 Seals Indicator Bypass settings.5 Bar (22 Psi).5 Bar (22 Psi).5 Bar (22 Psi).5 Bar (22 Psi).5 Bar (22 Psi).5 Bar (22 Psi).5 Bar (22 Psi).5 Bar (22 Psi).5 Bar (22 Psi).5 Bar (22 Psi) Ports G 3 /4 G 3 /4 G G G /4 G /4 G /2 G /2 G /2 G /2 Included options None None None None Replacement elements 937878Q 937877Q 937852Q 937875Q 937853Q 937874Q 937855Q 937872Q 937857Q 93787Q Supersedes TXWL3- TXWL3-2 TXWL3E- TXWL3E-2 TXWL4- TXWL4-2 TXWL5A- TXWL5A-2 TXWL5C- TXWL5C-2 29 FDHB5UK/ETF FDHB5UK/TTF Geeve Hydraulics 26 Catalog 26 Hydraulic and Heavy Duty Filtration & Contamination Control 29
Ordering Information (cont.) Product configurator Configurator example of a TTF Series filter Box TTF Box 2 9 Box 3 5QL Box 4 V Box 5 S3 Box 6 H Box 7 L24 Box 8 Box TTF Box 2 Filter type Housing TTF -6 TTF -9 TTF -2 TTF -4 TTF -75 TTF -5 TTF 2-7 TTF 2-23 TTF 2-3 TTF 2-4 TTF 2-5 2 3 4 4A 4B 5 6 7 8 9 Box 3 Element media Disposable element LEIF element Cellulose Nom. rating C Degree of filtration Glass fibre Microglass III (for disposable elements) Ecoglass III (for Leif elements) 2Q 2QL 5Q 5QL Q QL 2Q 2QL Wire mesh Abs. rating 4W Box 4 Seal material Fluorelastomer Neoprene Box 7 ßx(c)=2 5.% 6 Seal type B V On request Box 5 Filter connection Ports ISO 228-G 3 /4" (BSP) (TTF length 2,3,4 and 5) ISO 228-G" (BSP) (TTF length 2,3,4 and 5) ISO 228-G /4" (BSP) (TTF length 6 and larger) ISO 228-G /2" (BSP) (TTF length 6 and larger) 2xISO 228-G /2" (BSP) (TTF length 6 and larger) /2" SAE-3 PSI (TTF length 6 and larger) /2" SAE-3 PSI (2nd port) + G /2" (TTF length 6 and larger) G2" (TTF length 6 and larger) G2" + G /2" (TTF length 6 and larger) Indicator Pressure gauge, setting.2 bar, Mx* Pressure gauge, setting.2 bar, G /8 for dual head ports Pressure switch 42V,.2 bar setting, NO/NC, Mx* Pressure switch 42V,.2 bar setting, NO with G /8 BSP* Pressure switch 42V,.2 bar setting, NC with G /8 BSP* Pressure switch 25V, NO/NC with G /8* Pressure switch 22V, NO/NC with M* No indicator, indicator ports not machined No indicator, indicator ports L + R plugged Other settings for indicators / gauges on request Note: * HEAD HAS PLUGGED INDICATOR CONNECTIONS L+R Note: Also see the table indicator Connection/Filter Head Matrix on page 29 Box 8 Degree of filtration Average filtration beta ratio ß (ISO 6889) / particle size µm [c] ßx(c)= ßx(c)=75 ßx(c)= ßx(c)=2 ßx(c)= % efficiency, based on the above beta ratio (ßx) 9.% 6 9% 4.5 8.5 7 99.% 5 9 8 99.5% 6 2 G2 G6 G2 G24 2G24 On request LD24 On request GM32 99.9% 4.5 7 2 22 Media code 2Q/2QL 5Q/5QL Q/QL 2Q/2QL 23 23 23 23 G G2 S S2 S3 S4 S5 On request P2 on request Options Options No diffuser required with perforated plate area Diffuser type P without perforated plate area Funnel with integrated hose connection for TTF lengths 2, 3 and 4 No magnets filling port and no magnets Diffuser type P and no magnets, no magnets, plugged filling port Diffuser type P, no magnets, plugged filling port Air tight diffuser type T Air tight diffuser type P Other combinations ATEX certified* (Category 2, non-electrical equipment) Box 6 Bypass valve Bypass valve.8 bar.5 bar 2. bar for TTF series Blocked bypass Other bypass settings 3 4 On request 5 8 A B C D G H on request Note : TTF size 2-4 and 2-5 are standard supplied without magnets. Note 2*: For ATEX classified filters add EX after the code. For ATEX classified filters with electrical indicator are available on request. Visual indicators are classified as Category 2, non electrical equipment. Filter assemblies with EX code will be supplied with a dedicated name plate. Pls consult Parker Filtration for any questions related to the classification of our products. EX Item is standard Item is standard green option Item is semi standard Item is non standard B E H X on request Highlights Key (Denotes part number availability) 3 FDHB5UK. FDHB5UK/TTF 3 Geeve Hydraulics 26 Catalog 26 Hydraulic and Heavy Duty Filtration & Contamination Control
Ordering Information (cont.) Supersedes Spare Element table (TXWL & PXWL replaced by 9 number) TTF6 TTF9 TTF2 TTF5 TTF7 TTF23 TTF3 TTF4 TTF5 TXWL2-2 937823Q TXWL3-2 937824Q TXWL3D-2 937825Q TXWL3E-2 937826Q TXWL4-2 937827Q TXWL5-2 937828Q TXWL5A-2 937829Q TXWL5B-2 93783Q TXWL5C-2 93783Q TXWL2-5 93788Q TXWL3-5 937879Q TXWL3D-5 93785Q TXWL3E-5 937849Q TXWL4-5 937848Q TXWL5-5 937847Q TXWL5A-5 937846Q TXWL5B-5 937845Q TXWL5C-5 937844Q TXWL2-93788Q TXWL3-937878Q TXWL3D- 93785Q TXWL3E- 937852Q TXWL4-937853Q TXWL5-937854Q TXWL5A- 937855Q TXWL5B- 937856Q TXWL5C- 937857Q TXWL2-2 937882Q TXWL3-2 937877Q TXWL3D-2 937876Q TXWL3E-2 937875Q TXWL4-2 937874Q TXWL5-2 937873Q TXWL5A-2 937872Q TXWL5B-2 93787Q TXWL5C-2 93787Q Supersedes Spare Element table (TXW & TXX replaced by 9 number) TTF6 TTF9 TTF2 TTF4 TTF5 TTF7 TTF75 TTF23 TTF3 TXX2--B 93772 TXX3--B 937722 TXX3D--B 937723 FC26.C.BS 83926- TXX3E--B 937724 TXX4--B 937725 TXX5--B 937726 TXX5A--B 937727 TXW2-2-B 93775Q TXW3-2-B 93775Q TXW3D-2-B 937749Q FC26.Q2.XS 937977Q TXW3E-2-B 937748Q TXW4-2-B 937747Q FC275.Q2.XS 937979Q TXW5-2-B 937746Q TXW5A-2-B 937745Q TXW2-5-B 937754Q TXW3-5-B 937755Q TXW3D-5-B 937756Q FC26.Q5.XS 937978Q TXW3E-5-B 937757Q TXW4-5-B 937758Q FC275.Q5.XS 93798Q TXW5-5-B 937759Q TXW5A-5-B 93776Q TXW2--B 937787Q TXW3--B 937786Q TXW3D--B 937785Q FC26.Q.XS 937956Q TXW3E--B 937784Q TXW4--B 937783Q FC275.Q.XS 93798Q TXW5--B 937782Q TXW5A--B 93778Q TXW2-2-B 93779Q TXW3-2-B 93779Q TXW3D-2-B 937792Q FC26.Q2.XS 937957Q TXW3E-2-B 937793Q TXW4-2-B 937794Q FC26.Q2.XS 937982Q TXW5-2-B 937795Q TXW5A-2-B 937796Q ST2-4-B 93782 ST3-4-B 93789 ST3D-4-B 93788 ST3E-4-B 93787 ST4-4-B 93786 ST5-4-B 93785 ST5A-4-B 93784 TTF Series Seal Kit TTF Filter connections Seal Kit Ports Part Number ISO 228-G 3 /4 (BSP) (TTF length 2,3,4 and 5) 2492 ISO 228-G (BSP) (TTF length 2,3,4 and 5) 2492 ISO 228-G /4 (BSP) (TTF length 6 and larger) 2493 2xISO 228-G /4 (BSP) (TTF length 6 and larger) 984535 ISO 228-G /2 (BSP) (TTF length 6 and larger) 2493 2xISO 228-G /2 (BSP) (TTF length 6 and larger) 984535 /2 SAE-3 PSI (TTF length 6 and larger) 984535 /2 SAE-3 PSI (2nd port) + G /2 (TTF length 6 and larger) 984535 G2 (TTF length 6 and larger) 984535 G2 + G /2 (TTF length 6 and larger) 984535 3 FDHB5UK. FDHB5UK/TTF Geeve Hydraulics 26 Catalog 26 Hydraulic and Heavy Duty Filtration & Contamination Control 3