A T E X - S O L U T I O N S F R O M A E R Z E N

Similar documents
A E R Z E N S C R E W C O M P R E S S O R S

A E R Z E N E R M A S C H I N E N F A B R I K G M B H G EN

A E R Z E N S C R E W C O M P R E S S O R S

POSITIVE DISPLACEMENT BLOWERS. for conveyance and compression of process gases

A E R Z E N S C R E W C O M P R E S S O R S

Drive systems & electrical energy production for construction, local government structures, large infrastructure and industrial projects

AERZEN BULK VEHICLE BLOWER

Installation instructions

DOUBLE OCTOMILL TM PRODUCT RANGE

BOLL Automatic Filter TYPE The Compact Design Two-Chamber Filter. BOLL & KIRCH Filterbau GmbH

AERZEN ALPHA BLOWER MODULAR SYSTEM FOR LARGE BLOWERS. Oil-free. Pressure range up to 2 bar (a). Volume flow from 9,600 m³/h to 77,000 m³/h

1. General company data

1. INTERNATIONAL OVERVIEW. 1.0 Area and population. population (1,000) area

AUSTRIA. Table 1. FDI flows in the host economy, by geographical origin. (Millions of US dollars)

Knife gate valve JTV. Data is only for informational purpose. All specifications are subject to change without notice issue 11

Over time consistency of PPP results in the OECD countries

Civil Dialogue Group on WINE Thursday April 19th, 2018

ACEA Report. Vehicles in use Europe 2017

This document is a preview generated by EVS

replacement parts 6.1 General 6.2 Ordering

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS TO ATEX

Stafsjö s ATEX solutions for category 1 D (Zone 20)

NEW ALTERNATIVE FUEL VEHICLE REGISTRATIONS IN THE EUROPEAN UNION 1 Q1 2015

ESAB Welding & Cutting Products Attn: Customer Service Dept. P.O. Box , 411 S. Ebenezer Road Florence, SC

Knife gate valve TV. Data is only for informational purpose. All specifications are subject to change without notice issue 9

NEW ALTERNATIVE FUEL VEHICLE REGISTRATIONS IN THE EUROPEAN UNION 1 Q2 2015

ROTARY LOBE COMPRESSORS Delta Hybrid. For intake volume flows from 110 m³/h to 9,000 m³/h

Pumps and Flow Measurement for the Polyurethanes Industry

ROTARY LOBE COMPRESSORS DELTA HYBRID. For intake volume flows from 110 m³/h to 9,000 m³/h

Single-acting pneumatic cylinder type ECS

Roll Up WireFree IR. Installation instructions

A-L O C COOLING SYSTEM OLAER COOLERS. Olaer A-LOC with integrated circulation pump for industrial hydraulic systems

NEW COMMERCIAL VEHICLE REGISTRATIONS EUROPEAN UNION 1. April 2017

P r e s s R e l e a s e. June 2007

MODERNISATION SOLUTIONS. MRM W Line. T I M E T O M A X I M I Z E YO U R S P A C E!

Photo courtesy of NZTA

SBS-Control. Table of contents. Operating Instructions BKS24-9A. Operating Instructions

KRACHT Singapore Marine Products

GEA charge air cooler. Innovations that put big things into motion. GEA Heat Exchangers GEA Maschinenkühltechnik

MODERNISATION SOLUTIONS. MRM W Line. TIME FOR A FACE-LIFT!

Knife gate valve WB. Data is only for informational purpose. All specifications are subject to change without notice issue 12

ACEA Report. Vehicles in use Europe 2018

MAINTENANCE OF SMOKE EXTRACTION MOTORS

ISO Interface. Large capacity. Light weight. Accommodates enclosure IP65. Solenoid Valve (with M Connector) Conforming to ISO

Total credit to the non-financial sector (core debt), % of GDP Table F1.1

ECO-DESIGN OF ELECTRIC MOTORS

EHP2 Stainless steel piston accumulator

SF-Plus Blower and vacuum systems

OECD unemployment rate down to 6.4% in March 2016

NEW COMMERCIAL VEHICLE REGISTRATIONS EUROPEAN UNION 1 February 2018

Status Review on Smart Metering

Infographics on Electromobility (January 2019)

NEW PASSENGER CAR REGISTRATIONS EUROPEAN UNION 1

A E R Z E N P O S I T I V E DISPLACEMENT BLOWERS

WLTP for fleet. How the new test procedure affects the fleet business

TOP SMART intelligent position monitor:

ADR: Accord Européen Relatif au Transport International des Marchandises Dangereuses par Route

Standard Product Program. AirLINE & AirLINE Quick Type 8640 & Type 8644

Rectangular photoelectric proximity switches

PREVIEW. Fieldbus System for Distributed I/O NEW PRODUCTS

June EU Countries NEW COMMERCIAL VEHICLE REGISTRATIONS. PRESS EMBARGO FOR ALL DATA: July 26, 2013, 8.00 A.M. (6.00 A.M. GMT)

The new STx chain hoist NEW. Sophisticated technology prepared for the future

EHP2 Carbon steel piston accumulator

MWA /MWB Roundline Cylinders

Production of heat by type Terajoules

STEEL INDUSTRY ELECTRIC ARC FURNACES REFRACTORY CONCEPT SOLUTIONS

STEEL INDUSTRY STEEL LADLES REFRACTORY CONCEPT SOLUTIONS

Labour Market Latest Trends- 1st quarter 2008 data 1

Knife gate valve WB. Data is only for informational purpose. All specifications are subject to change without notice issue 13

Spain s exports by oil product group and country of destination

OECD unemployment rate down to 6.5% in January 2016

Knife gate valve WB11

VINYL ROLLS. Allover effects / Acczent Excellence 80

Emissions per capita and GDP

Ceram 4-way Pneumatic Directional Control Valve Tough enough to survive, no matter where in the world you send it.

Potential Danger of Fire or Explosion Read this letter now!

Passenger cars in the EU

OECD unemployment rate falls to 6.0% in March 2017

Global Valuation Summary - SAMPLE PAGES

Extraction arms for every type of application

ErP Directive ErP Implementing Regulation 327/2011. The new minimum efficiencies for electrically powered blowers and the impact on Elektror devices

OECD unemployment rate stable at 5.8% in August 2017

5-door FRS-ID: Year of production Legend. Version 4.3b / Opel Automobile GmbH. High strength zone

BREXIT AND THE AUTO INDUSTRY: FACTS AND FIGURES

Mobile Hydraulics Solutions

Better sealing solutions for reciprocating compressors

NEW PASSENGER CAR REGISTRATIONS BY ALTERNATIVE FUEL TYPE IN THE EUROPEAN UNION 1 Quarter

EMS215ic, EMP215ic, EM215ic

September 2011 compared with August 2011 Industrial producer prices up by 0.3% in euro area Up by 0.4% in EU27

NEW COMMERCIAL VEHICLE REGISTRATIONS EUROPEAN UNION 1. December 2018

Made UNDER high pressure

NEW PASSENGER CAR REGISTRATIONS BY ALTERNATIVE FUEL TYPE IN THE EUROPEAN UNION 1 Quarter

STATISTISCHER ANHANG VORLÄUFIGE AUSGABE

PARTS MANUAL EMP 285ic 1ph & EMP 285ic 3ph

OECD unemployment rate stable at 5.3% in July 2018

BPW AFTERMARKET GROUP

Armaturenwerk Hötensleben GmbH. AWH-Connect

NEW COMMERCIAL VEHICLE REGISTRATIONS EUROPEAN UNION 1. November 2018

NEW COMMERCIAL VEHICLE REGISTRATIONS EUROPEAN UNION 1. October 2016

PSF 250, PSF 305, PSF 405, PSF 505, PSF 405 RS3 PSF 410W, PSF 510W, PSF 410W RS3, PSF 510W RS3,

Transcription:

A T E X - S O L U T I O N S F R O M A E R Z E N A E R Z E N E R M A S C H I N E N F A B R I K G M B H A1-020 03 EN 2000 9.2008

Customers benefit and ATEX-requirements Aerzener Maschinenfabrik has been manufacturing Positive Displacement blowers since 1868 and Screw compressors since 1943. It is one of the oldest and biggest manufacturers worldwide and is in some ranges the market leader in Europe. Technical competence, experienced employees and continuous dialogue with the customers are the basis for successful new developments from Aerzen. The connection between changing regulations as well as the ATEX-guideline and additional benefit for customers by innovative products for plant manufacturers and operators is also in the focus. Ranges of application and use DELTA BLOWER units made by Aerzener and DELTA SCREW compressor units made by Aerzener were designed for conveying air and neutral gases and are used in chemistry- and process technology, for pneumatic transport of bulk materials and in many other ranges of the present industrial technology. The installation of the European machine directive 94/9/ EG for explosive areas in all applications plays a more and more important role. The blower- and compressor units made by Aerzener are especially designed for the requirements in categories 2 and 3 for dust- as well as for gas zones and certified accordingly by the manufacturer. Machines for category 1 however must be subject to an EG-type test referring to the individual case. For certain individual projects this was already carried out successfully. For special conditions in industrial vacuum technology the High vacuum blowers and the new canned motor blowers were subject to a complete successful type test. These machines, used in pressure ranges up to 10-5 mbar (abs.), are approved for zone 0 (internal) and certified by an appointed authority. Example of machine labelling Ex II 2 (o) G E Ex c T4 Temperature class concerning gas, surface temperature conc. dust T4 = 135 C Type of ignition protection constructive safety Explosion protection European standards EN Ex-atmosphere (G = gas, D = combustible dust) Internal / external explosive atmosphere (i = internal, o = external) Category 2 Device group II Label for prevention of explosions 2

Measurements taken Aerzen DELTA BLOWER units: (suction from ex-zone) (suction from ex-zone) Overpressure Overpressure (ex-free suction) (ex-free suction) (suction from ex-zone) (suction from ex-zone) Negative pressure Negative pressure (ex-free suction) Measures zone zone zone zone 1 21 1 2 22 1 1 21 1 2 22 1 1 21 1 2 22 1 1 21 1 2 22 1 Gastight machine x - x - - - - - x - x - - - - - Explosion pressure proof accessories x - x - - - - - x - x - - - - - Additional strength test x - x - - - - - x - x - - - - - Disch. temperature monitoring x - - - x x - - x - - - x x - - Gas alarm device (at site) x - - - - - - - - - - - - - - - Starting strainer x - x - x(g 2 ) - x(g 2 ) - x - x - x - x - Intake sided filter (filter silencer) - - - x x(l 2 ) x x(g 2 ) x - - - - - - - - Intake sided filter (same design as zone separating filter but without suction valve, only DN 80-150) - x - - - - - - - - - - - - - - Intake sided filter (at site) x - x - x(g 2 ) - x(g 2 ) - x x x x x x x x Zone separating filter (only DN 80-150) - - - - - - - - - x - x - - - - Intake pressure monitoring by pressure switch - x - x - - - - - - - - - - - - p-monitoring via zone separating filter - - - - - - - - - x - x - - - - Protection via vacuum switch (suction valve not necessary) - - - - - - - - - - - - x x x x Vibration monitoring x - - - - - - - x - - - - - - - Electrical operating means Are always to be procured acc. to the corresponding zone Atex-certificate x x x x x x x x x x x x x x x x Additional label x x x x x x x x x x x x x x x x Additional operating manual x x x x x x x x x x x x x x x x 1 It must absolutely be avoided, that dust atmosphere develops inside the machine. In case of suction from a dust atmosphere or in case of suction-pneumatic applications a suitable filter is to be used acc. to the above chart. These Aerzen filters in connection with the corresponding monitoring facility serve as zone separating element. 2 G=gas-fuelled operation, L= air operation For zone 0-applications a type test by an appointed authority is necessary. For such machines a technical release is necessary. Aerzen DELTA SCREW compressor units: (ex-free suction) Measures zone zone zone zone 1 21 2 2 22 2 1 21 2 2 22 2 1 21 2 2 22 2 1 21 2 2 22 2 Convey. chamber gastight, connect oil demister to continuing pipe, or flare x - x - - - - - x - x - - - - - Additional strength test x - x - - - - - x - x - - - - - Disch. temperature monitoring x - - - x x - - x - - - x x - - Gas alarm device (at site) x - - - - - - - - - - - - - - - Coupling Is always to be procured acc. to the corresponding zone Starting strainer x - x - x(g) 4 - x(g) 4 - x - x - x x x x Suction-sided filter - x 3 - x x(l) 4 x x(l) 4 x - - - - - - - - Intake side filter (same design as zone separating filter but without suction valve (provided by - x - - - - - - - - - - - - - - customer) Intake sided filter (at site) x - x - x(g) 4 - x(g) 4 - x x x x x x x x Zone separating filter (provided by customer) - - - - - - - - - x - x - - - - Intake pressure monitoring by pressure switch - x - x - - - - - - - - - - - - p-monitoring via zone separating filter (provided by customer) - - - - - - - - - x - x - - - - Vibration monitoring x - - - - - - - x - - - - - - - Electrical operating means (driving motor, oil demister, instrumentation, Are always to be procured acc. to the corresponding zone electr. fan, etc.) Atex-certificate x x x x x x x x x x x x x x x x Additional label x x x x x x x x x x x x x x x x Additional operating manual x x x x x x x x x x x x x x x x 1 Is only possible for VM-machines (except VM 8R). Not possible for VML-machines. 2 It must absolutely be avoided, that dust atmosphere develops inside the machine. In case of suction from a dust atmosphere or in case of suction-pneumatic applications a suitable filter is to be used acc. to the above chart. These Aerzen filters in connection with the corresponding monitoring facility serve as zone separating element. 3 not for gearbox machines 4 G=gas-fuelled operation, L= air operation For zone 0-applications a type test by an appointed authority is necessary. For such machines a technical release is necessary. 3

Aerzen vacuum blowers series HV and CM: Vacuum pressure Measures zone zone 0 1 21 2 22 0 1 21 2 22 Strength test as spot check x x not applic. x not applic. not applic. - - - - Discharge temperature monitoring x x not applic. - not applic. not applic. x x - - Differential pressure monitoring * x - not applic. - not applic. not applic. - - - - Differential pressure monitoring - - not applic. - not applic. not applic. - - - - Starting strainer x x not applic. x not applic. not applic. - - - - Vibration monitoring (online) x - not applic. - not applic. not applic. - - - - Vibration monitoring (at intervals) - x not applic. - not applic. not applic. x x - - Bypass control not necessary, machine can be flown through via frequency converter and direct drive under atm. conditions Electrical equipment to be carried out acc. to corresponding zone Coupling with certificate - - not applic. - not applic. not applic. x x x x Atex certificate x x not applic. x not applic. not applic. x x x x Additional nameplate x x not applic. x not applic. not applic. x x x x Additional operating manual x x not applic. x not applic. not applic. x x x x * only necessary for zone 0, does not serve as monitoring unit, but controls the additional switching of the drive of the Roots pump when falling below 100 mbar, resp. as option with zone 0 the switching on /-off of monitoring units. Ex-protection for units acc. to ATEX guideline 137 The EU-directive 1999/92/EG (ATEX 137) fixes that employer (unit operator) fulfill certain requirements on the field of safety and health protection for employees who have to face the risks of explosive atmospheres. In the ex-proof document possible ignitian sources are analysed and technical (constructive) and preventive measures must be described. Prior to commissioning of new units this ex-proof document must be issued. Based on the ex-proof document the work halls need to be modified until 30th June 2006 according to the minimum regulations of EU-directive 1999/92/EG and to be documented correspondingly. Ex-protection in the pneumatic bulk material conveyance If combustible bulk material is conveyed pneumatically, in case of certain dust-/air concentrations inflammable gas mixtures may develop in the unit. Unit components are allocated to different zones. For example, silo content is declared with zone 21 as explosive atmosphere may be present continuously or for a longer period of time. The conveying piping is defined also as zone 21 as an explosive dust-/air mixture occurs only occasionally. For these two zones according to Atex guideline also in case of possible damages protection against explosion must be guaranteed. As zone 22 areas are marked where the explosive atmosphere hardly occurs or only for a short period of time. Diagrammatic section of pressure conveyance bulk material entrance bulk material entrance * Spark arrester * Spark arrester * Spark arrester can be omitted on use of Aerzener compressors Blower 4 * Spark arrester can be omitted on use of Aerzener blowers Compressor zone 20 zone 21 zone 22

External areas of constantly technically safe units are declared as zone-free, i.e. preferred installation place of blowers, compressors and pumps. The zone clarification and definition of temperature class are carried out by the unit operator. An aspect not being considered very often in the pneumatics is that in case of unusual failure the blower may produce sparks, these will then be blown into the conveying piping, where ingnition of the dust/air mixture may take place. In case of a bearing damage caused by e.g. insufficient maintenance, the consequence might be that the rotary pistons touch and ignition sparks develop. Organic dust/air mixtures are inflammable at temperatures between 200... 500 C. One ignition spark reaches a temperature between approx. 800 C and 1000 C, so that in such a case some resulting damage cannot be excluded. Unit manufacturer and operators who consider this would install additional spark stops causing investment and considerable installation costs as well as pressure losses. Certified Aerzen base support Aerzener Maschinenfabrik has faced this challenge and has worked on a solution which was certified by the TÜV Nord. Base is DELTA BLOWER units serving as discharge silencer. The sound developed is dampened in this especially designed base support without application of absorption material. In expensive practical tests artificial sparks had been produced and fed through the base support for several minutes with an air flow corresponding air inlet to the conveyed volume flow of a blower with the consequence that the sparks are deleted by internal deviations. Therefore, costly spark traps fitted in addition can be omitted in future. The secret of success is the innovation of Aerzen discharge silencer. The absorption material normally used which is combustible and not foodstuff-compatible is not necessary anymore. The certification of Aerzen blower units includes the nominal widths from DN 50 to DN 250 and was extended besides the current designs (Generation 5) onto the Delta Blower-designs supplied since 1994. A subsequent certification for units already supplied (series Delta Blower) for preparing the explosion protection document is thus possible. This ATEX certification was extended to the new compressor units Delta Screw Generation 5 for which the innovative discharge silencer takes the function of the spark arrester. air deviating air outlet discharge piping base support of blower: diagrammatic section 5

Special filter element for the suction pneumatic (for blowers only) Depending on the product and system configuration bulk goods are conveyed however not only in overpressure operation, but also by means of suction pneumatic transport. In suction operation it has to be ensured in case of a malfunction in the separation filter (e. g. filter fracture) that no combustible dust-air-mixture is sucked into the blower. For this reason normally an additional filter element (emergency filter) is provided by the plant manufacturer. Consequently an additional expenditure for project work, assembly and installation will occur. Therefore Aerzener Maschinenfabrik has developed a puncture-proof filter element which can be integrated in the suction silencer. The filter is monitored by a differential pressure measurement. Consequently the Aerzen special filter element replaces the previous additionally necessary emergency filter. Schematic description in case of suction conveyance (blowers) Separation filter Bulk material entrance Filter Separation filter Bulk material entrance Filter Emergency filter zone 20 zone 21 zone 22 Integrated emergency filter (option) Listing of customer benefit New puncture-proof Aerzen filter element (for blowers only) The innovative silencer operating without absorbent material realizes the spark arrester for the compressor. Subsequent certification of Aerzen units (series Delta Blower) for preparing the explosionprotection document is possible. With the innovative and certified Aerzen base support resp. discharge silencer unnecessary installations are avoided and consequently pressure- and energy loss prevented! Plant safety acc. to 1999/92/EC (explosion protection document) for the operator! Re-certification for Aerzen Blower Units (Delta Blower) possible in existing plants! Clear cost advantages by the new integrable Aerzen filter element (blowers). This replaces a costly external filter element. Aerzen Blower Units DELTA BLOWER (blower stage and pressure-containing accessories) can be designed to be pressure shock-proof up to an explosion overpressure of 13 bar (extra price). The acoustic hood ventilation is effected by a mechanically driven fan (Aerzen Standard for blowers and compressors). The costly electrical integration and monitoring of an explosion-proof motor for the necessary hood ventilation is not included. Thanks to optimized logistics attractive delivery dates as well as inexpensive additional documentation and marking! 6

ATEX-solutions for the vacuum technology The Aerzen Vacuum Blower series HV is designed for the conveyance of air and neutral gases and can specially be used in the industrial vacuum technology, for example, coating of glass and foils, in the packaging technology, the metallurgy and in many further applications. There are 19 blower sizes in the vacuum range covering suction flows from 180 m³/h up to 97.000 m³/h as well as pressure ranges (abs.) from 10-3 mbar up to 200 mbar. Specially in the chemical industry, but also in other applications, the ATEX-requirements increase constantly. Many manufacturers interpret the ATEX-guideline so that machines, which are used in a pressure range of below 800 mbar, are not subject to certification. However this is only partly correct, as the harmonized standard EN 13463-1:2001 (D) clearly supplements that in case of machines not within the range of validity of this standard, the suitability of the devices for possible application conditions have to be clearly shown and proven. Against this Aerzener Maschinenfabrik has decided, that the complete vacuum series is subject to a type testing acc. to guideline 94/9/EC to be able to offer the plant manufacturers and operators safe solutions corresponding to ATEX. Afterwards the Aerzen Vacuum Blower Series HV as well as the blowers with canned motor of the series CM were certified for zone 0 (internal), temperature class T3 (200 C) in April 2005. The blowers are externally admitted for zone 1, temperature class T4 (135 C). For zone 0 a temperature and vibration monitoring on the blowers is additionally to be provided. Materials of grey-cast iron or nodular cast iron can be used. A special advantage for the customer with the Aerzen ATEX-solution is that an extremely costly bypass - solution is omitted. The Aerzen ATEX-certification admits a so-called suction of the fore pump and a frequency converter operation at restricted speed of the Aerzen Vacuum Blowers. Sectional model GM 11.3 HV for the suction pneumatic Advantages for the customer Aerzen Vacuum Blowers external casing is designed for temperature class T4 guaranteeing safety for difficult applications! When using Aerzen Vacuum Blowers the application of an external bypass control is no longer necessary, causing a considerable cost saving in the plant manufacturing! The possible shutdown of the monitoring device below 50 mbar ensures process safety for the operator! Pressure shock resistance up to 13 bar! Inexpensive documentation! Conventional bypass pipe (marked in red) can be omitted in future!! Y ( ) TS+ PZS+ M M 7

A good address, everywhere Federal Republic of Germany Aerzener Maschinenfabrik GmbH. Reherweg 28 31855 Aerzen / Germany Tel. + 49 51 54 8 10 Fax + 49 51 54 8 11 91 Vertriebsbüro Nord Weißer Kamp 23 29683 Bad Fallingbostel Germany Tel. + 49 51 62 98 13-0 Fax + 49 51 62 98 13 20 Vertriebsbüro Ost Klosterstraße 8-9, 13581 Berlin / Germany Tel. + 49 30 36 75 84-6 Fax + 49 30 36 75 84 80 Außenstelle Taucha: August-Bebel-Str. 13c 04425 Taucha / Germany Tel. + 49 34 29 81 46 86 Fax + 49 34 29 81 46 87 Vertriebsbüro Mitte Erfurter Straße 2 63796 Kahl / Germany Tel. + 49 61 88 91 04-0 Fax + 49 61 88 91 04 20 Vertriebsbüro Süd Föhrenweg 1 89275 Elchingen / Germany Tel. + 49 73 08 96 08-0 Fax + 49 73 08 96 08 20 Vertriebsbüro West Taubenstraße 12 42551 Velbert / Germany Tel. + 49 20 51 98 54-0 Fax + 49 20 51 98 54 18 Außenstelle Nahlbach Meisenweg 13 66809 Nahlbach / Germany Tel. + 49 68 38 89 95 95 Fax + 49 68 38 98 58 78 Europe Aerzen-France S.A.S. 10, Avenue Léon Harmel 92168 Antony Cedex France Tel. + 33 1-46 74 13 00 Fax + 33 1-46 66 00 61 for France, Algeria, Morocco and Tunesia Aerzen Machines Ltd. Aerzen House, Langston Road Loughton, Essex, IG 103 SL United Kingdom Tel. + 44 20 85 02 81 00 Fax + 44 20 85 02 81 02 Aerzen Belgium NV Zone Guldendelle A. De Coninckstraat 11 3070 Kortenberg / Belgium Tel. + 32 2-7 57 22 78 Fax + 32 2-7 57 22 83 for Belgium and Luxembourg Aerzen Nederland B.V. Fotograaf 3 6921 RR Duiven The Netherlands Tel. + 31 26-311-26 41 Fax + 31 26-311-73 69 Aerzen Iberica S.A. c/urogallo 13 28946 Fuenlabrada / Spain Tel. + 34 91-6 42 44 50 Fax + 34 91-6 42 29 03 Aerzen Iberica S.A. Rua: Sacadura Cabral, 216, 7 B 2765-349 S. João do Estoril Portugal Tel. + 35 12 14 68 24 66 Fax + 35 12 14 68 24 67 Aerzen Svenska AB Östra Bangatan 20 19560 Arlandastad Sweden Tel. + 46 8-59 12 21 90 Fax + 46 8-59 11 72 09 Aerzen Finland Oy AB Teollisuustie 15 02880 Veikkola / Finland Tel. + 35 89-8 19 47 20 Fax + 35 89-4 77 22 25 Bran & Luebbe AS Sandviksveien 22 1363 Høvik / Norway Tel. + 47 67 83 26 50 Fax + 47 67 83 26 51 for Norway and Iceland Aerzen Svenska AB Nakskovvej 28 2500 Valby / Denmark Tel. + 45 36 16 40 48 Fax + 45 36 16 40 48 Aerzen Austria Handelsges. m.b.h. Gewerbepark Tresdorf II/1 2111 Tresdorf / Austria Tel. + 43 22 62 7 43 88 Fax + 43 22 62 7 43 99 Aerzen (Schweiz) AG Zürcherstrasse 300 8500 Frauenfeld Switzerland Tel. + 41 52-7 25 00 60 Fax + 41 52-7 25 00 66 for Switzerland and Liechtenstein Aerzen Italia SRL Via Vittor Pisani, 28 20124 Milano / Italy Tel. + 39 02-67 07 52 77 Fax + 39 02-67 07 50 03 MANGRINOX S.A. 14, Grevenon Str. 11855 Athens / Greece Tel. + 30 210-3 42 32 01-3 Fax + 30 210-3 45 97 67 Aerzen Makine Sanayi Ve Ticaret Ltd. Sti. Yukarı Dudullu Bostancı Yolu Cad. Keyap Sitesi A-2 Blok No:12 34775 Ümraniye - Istanbul Turkey Tel. + 90 420 00 32 Fax + 90 420 00 79 Aerzen Polska S.A. Ul. Marconich 9/17 02-954 Warszawa / Poland Tel. + 48 22 642 29 09 Fax + 48 22 642 33 08 Aerzen Slovakia S.R.O. Mariánska 17 90031 Stupava / Slowakia Tel. + 42 12 65 93 46 94 Fax + 42 12 65 45 71 01 Aerzen Hungária Kft. Bécsi ùt 52.III./4. 1036 Budapest / Hungary Tel. + 36 14 39 22 00 Fax + 36 14 39 19 22 Aerzen Cz s.r.o. Namesti TGM 729/7 69002 Breclav Czech Republic Tel. + 42 05 19 32 66 57 Fax + 42 05 19 32 66 58 HAFI Engineering & Consulting Gesellschaft m.b.h. Mühletorplatz 4-6 6800 Feldkirch / Austria Tel. + 43 55 22-7 79 24-0 Fax + 43 55 22-7 49 38 for the remaining countries in Eastern Europe Brasil, Mexico, USA, Canada and Asia Aerzen do Brasil Ltda. Rua Howard Archibaldi Acheson Jr. N 615 Jardim da Glória, Cep 06711 280 Cotia, SP / Brasil Tel. + 55 11-46 12 40 21 Fax + 55 11-46 12 02 32 Aerzen México Av. San Rafael 31 Fraccionamiento Industrial Lerma Lerma 52000 Estado de México (Toluca) / México Tel. + 52 72 82 82 55 08 Fax + 52 72 82 82 51 97 Aerzen USA Corporation 645 Sands Court Coatesville, PA 19320 / USA Tel. + 1 610-3 80 02 44 Fax + 1 610-3 80 02 78 Aerzen Canada Blowers Compressors Inc. 1995 Montée Labossière Vaudreuil, Quebec J7V8P2 Canada Tel. + 1 450-4 24-39 66 Fax + 1 450-4 24-39 85 Aerzen Asia Pte. Ltd. 38 Woodlands Industrial Park E1 #04-01 Singapore 757700 Tel. + 65 6254 5080 Fax + 65 6254 6935 Aerzen International Trading (Shanghai) Co. Ltd. No. 519 Tong Li Road Jiu Ting Town Song Jiang District 201615 Shanghai / P.R.China Tel. + 86 21 5109 7767 Fax + 86 21 5109 7768 Aerzen Machines (India) Private Limited 301-1 A Square Building 82-Urmi Society Productivity Road Vadodara - 390007 / India Tel. + 91 265 2324306 Tel. & Fax + 91 265 2324307 We would be pleased to provide the addresses of our representatives in the remaining continents, upon request. Aerzener Maschinenfabrik GmbH Reherweg 28. 31855 Aerzen / Germany P.O. Box 1163. 31849 Aerzen / Germany Phone ++ 49 51 54 / 8 10. Fax ++ 49 51 54 / 8 11 91. www.aerzen.com. info@aerzener.de