kyleave Surveillance to the Top

Similar documents
ThinkTop DeviceNetTM VDC DeviceNet is a Trademark of the Open DeviceNet Vendor Association, Inc. (ODVA).

Instruction Manual. ThinkTop DeviceNet TM VDC ESE00355-EN Patented Sensor System Registered Design Registered Trademark

Instruction Manual. ThinkTop D30 ESE02248-EN Patented Sensor System Registered Design Registered Trademark. Original manual _1

Instruction Manual. ThinkTop Digital, AS-Interface and DeviceNet ESE02952-EN Patented Sensor System Registered Design Registered Trademark

Instruction Manual. ThinkTop DeviceNet TM VDC ESE00355-EN The Top is identified by 4 fastening screws. Original manual TD800100_3

Instruction Manual. Unique PMO Plus Mix-Proof Valve. Unique PMO Plus -CP Mix-Proof Valve

Instruction Manual. Unique PMO Plus CP HT Series Sanitary Mixproof Valve Sizes 2½", 3", 4" & 6" ESE Effective 05/04/2012

Aseptomag Valve Technology Order Code. T.VIS Control top

Valve Manifolds Series

Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information

SMP-BCA Aseptic Mixproof Valve with PTFE Diaphragm

CONTROLS. Bray Pneumatic Actuators & Accessories. Technical Manual. A Division of BRAY INTERNATIONAL, Inc.

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. R-Series Models RP and RH DeviceNet Output.

kysimply Unique Unique 7000 Series

Unique RV-ST Regulating Valve

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

ARO EasyWire System Installation Guide

Temposonics. R-Series DeviceNet. Magnetostrictive Position Sensors. Intelligent Design. Temposonics RP and RH Measuring length mm SENSORS

Prism PI Intelligent features offer advanced performance

Lexium integrated drives

Series 905-IV16(E) CAN/CANopen Input Modules Installation and Operating Manual

Valves. Valves The Parkway, Peterborough, ON K9J 7K Fax:

kysimply Unique Single Seat

HIGH POWER SOLENOID DRIVER 1

REGAL-BELOIT SpinMaster AC Adjustable Speed Drives

kysimply Unique Regulating

VFD E Series. Features

kysimply Unique Unique 7000 Series Y-Body

HIPERDRIVE HDA70: Integrated positioning drive with absolute measurement system for format adjustment

+ = Angle-seat Valve System for continuous control. Type 8802/2300 electro-pneumatically operated angle-seat valve

kymanual or Automatic - it s your Choice

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

Lexium integrated drives

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

JUMO dtrans p35. Pressure Sensor with IO-Link. Application. Brief description. Customer benefits. Special features

PGS Gripper Double Blank Sensors

Encoder WDGA 58V CAN SAE J1939

kyproven Performance Alfa Laval i-bfv Automatic or Manual Butterfly Valve

Es cambiar entre cinco posiciones. Product line - double monitor M31. Valve Signalling Monitor. Sense 1

2005 / 2012 / 2035 Series

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

INTECH Micro 2300-RTD6

SX5 Series Smart I/O (General Information)

Paddle-wheel flow controller for On/Off control

M-VUE The Intelligent Valve Monitor

PUR (A, B, C, D) INSTRUCTION FOR VARIABLE SPEED WITH WIRING DIAGRAM FOR EMX P10 ROTOR SIZE

Positive displacement batch controller

Signet Pressure Transmitter

Electronic Pressure Switch EDS 3000

OPTISWITCH 6500 C Technical Datasheet

sinamics SINAMICS G110 Variable Speed Drives 0.12 kw to 3 kw SINAMICS G110 Short Form 2004

JC-VSD FP Series II Drives Product Bulletin 1

VSD Series II Variable Speed Micro Drives

MT50 & MT150 Electrical Multi-turn Valve Actuators

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

FT-10 Network Digital I/O Module Kits and

Series ITV1000/2000/3000

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

FIELDBUS ELECTRONICS 580 Electronics (Series : M7 to 1/2 (G or NPT) or with push-in fittings Ø4 to 10 mm)

Flow measurement FlexFlow PF20H Hygienic flow sensor

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

Technical Operation Manual. SI Unit Model No. : EX230-SDN1

Emergency lighting units EM powerled

APS & APIS ATEX AIRPOWER SWITCH BOXES FEATURES DESCRIPTION

kyalfa Laval Weighing Systems UltraPure with digital beam load cell

Proportional relief valves

PRODUCT USER MANUAL. SQ57 CANopen Motors. SMI21 CANopen. Important Notes

Proportional reducing valves

MCD Pump Application Module

IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Today Numatics is proud to be a part of the Industrial Automation Division of Emerson Electric Co.

SED2 VFD NEMA Type 3R and Type 3R Harsh Environment (3RHE) Bypass

Zone Safety Manifold. Fielbus Electronics Availability, design and specifications are subject to change without notice. All rights reserved.

825-P Modular Protection System for motors Specification Guide

Expansion Signal (XSIG) Card Installation Instructions

The Cleanest Design. SRC Sanitary Remote-Controlled Valve PD US

EB 80 SUMMARY EB 80 DISTRIBUTORS P EB 80 ELECTRO-PNEUMATIC SYSTEM PAGE 4 P EB 80 BASIC PAGE 13 P EB 80 - SIGNAL MODULES - S PAGE 16

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

2.7. IT system floor-standing distribution cabinet Series -IPS-F

Related vacuum products

Electronic Limit Switch Type

Control block VOFA with safety function

Paddle-wheel flow controller with optical principle for On/Off control

DeviceNet Interface For Series 75 Electric Valve Actuators

APV CU3 Valve-Net DeviceNet

HGM1750 Genset Security Module USER MANUAL Smartgen Technology

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Proportional pressure reducing valves type DHRZO direct operated, ISO 4401 size 06

DELTA SD4. double seal valves

Updated: October 2012

Signet Pressure Transmitter

BR Second Position Voltages. AA Fourth Position

CARRARO TRAX TLB2 Electronic Module Specification. 29/11/2006, Rev. 5

The Intelligent Valve Sensor. DeviceNet

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

Transcription:

HYGIENIC EQUIPMENT FOR FOOD & LIFE SCIENCES. kyleave Surveillance to the Top ThinkTop DeviceNet TM 11-25 VDC Application The ThinkTop is designed to ensure optimum valve control in conjunction with Alfa Laval sanitary valves and it is compatible with most PLC systems (Programmable Logic Controllers) with DeviceNet. It is for use in food, dairy and brewery installations and in biopharmaceutical applications. Working Principle The ThinkTop is a control head including indication units and solenoid valves to control all kinds of processing valves. It is used to control and supervise pneumatic valves and it is mounted on top of the valve. It receives signals from a PLC to control the valve and it sends feedback signals to the PLC to indicate when the valve is in a certain position. To adapt the sensor board to the specific valve and to the application, the user sets up the ThinkTop either by the local keys or by using the key pad (which is ordered separately). When using the key pad it is not necessary to dismantle the top unit. Sensor System Unique No Touch sensor system without any mechanical sensor adjustments. A magnet (indication pin) is mounted on the valve stem and the magnetic field (axial) is detected by sensor chips inside the sensor board. The measuring angle from each chip is used to locate the current position of the valve stem with an accuracy of ± 0.1mm. Note that the distance to the magnet can be 5 mm ± 3 mm.. Feedback Signals (class 4) The sensor system can be used for 4 feedback signals + 1 status signal = 5 feedback signals. 2 of the feedback signals can be external sensors if necessary. The status signal is used for detection of the following: - Set-up is in progress. - Internal error. - Maintenance is required (based on time and/or the self adjustment programme). - A conflict in the self adjustment programme. ThinkTop Standard Design The ThinkTop has a simple, modular and robust design which ensures a quick and easy assembly/disassembly. It consists of a base containing a sensor board with LEDs, an indication pin, terminals for internal electrical connection, solenoid valves and a shell. See also Fig. 1"BasicDesign". It is prepared for upgrading and is exchangeable. The design is hygienic and easy to clean. DEVICENET IS A TRADEMARK OF THE OPEN DEVICENET VENDOR ASSOCIATION, INC. (ODVA) The LEDs are constantly indicating the status of the unit: Valve position, solenoid energized, setup and local fault indication, maintenance and seat-lift.

Features Tolerance Programmes Individual tolerance programmes for all Alfa Laval sanitary valve types are part of the ThinkTop concept ensuring correct feedback to the PLC for open and closed valve position. If the function is disabled, the tolerance band will be ± 5 mm. Self Adjustment (SRC/ARC Aseptic valves only) The self adjustment feature is an exceptional aspect of the ThinkTop design. A programme can be activated to allow an adjustment of the tolerance band if the seals in the valve are being compressed or are worn. When the tolerance band of the unit has been adjusted 0.3 mm, an alert warning will appear in the form of a status signal and a flashing maintenance LED. After 0.5 mm adjustment an alarm warning appears: Loss of feedback signal, status signal and steady maintenance light indicating a minimum of seal left requiring a replacement of the seal. Built-in Maintenance Monitor The unit can be preset to indicate when the time for maintenance of the valve has been reached. A status signal and flashing maintenance LED can be programmed to return after 3, 6, 9 or 12 months or more. Special features (class 100) -TimeTOTAL...-TimeCLOSED -TimeOPEN...-Timetomaintenance -LastStrokeTime...-LastStrokeLength -CoilCount#1...-CLOSEDcount -CoilCount#2...-OPENcount -CoilCount#3...-Timeoflastmaintenance Other Features Another very important fact is that the setup is kept until programmed, even during failure in the power supply. The accurate sensor system enables indication of seat-lift to be integrated in the top unit. Materials Plasticparts:...NylonPA12Reinforced. Steelparts:...Stainlesssteel1.4301 (304) and 1.4404 (316). Gorevent.membrane...PBTplastic. Airfitting...Specialcoatedbrass(FDA approved). Seals:...Nitrile(NBR). Technical Data Sensor System: Sensor accuracy:......±0.1mm Distancetoindicationpin:...5±3mm Strokelength:...0.1-80mm DeviceNet interface The baud rates: 125k, 250K and 500K. I/O slave messaging as polling or change of state. Poll: 7 or 2 bytes. COS:2bytes,7bytesisnotsupported. * 2 bytes = Inputs/outputs and alarms (class 4) 7bytes=Inputs/outputs, alarms and class 4+100 attributes Changing from 7 bytes to 2 bytes: Remove jumper between terminals (#12 and #13). A power recycle is necessary when changing byte sizes. Node address Range: 0 63. Default slave address: 63. Node 0 is normally used by the DeviceNet scanner. Power supply The power supply to the complete unit is taken from the DeviceNet network. Supplyvoltage: Supplycurrent:...11 25VDC,asspecified for the DeviceNet...Max. 45mA(forsensor board alone) (excluding current to the solenoids and the external sensor). The fulfilling of the UL requirements in UL508 requires that the unit is supplied by an isolating source complying with the requirements for class 2 power units (UL1310) or class 2 and 3 transformers (UL1585). Feedback signals Input signals (produced by the sensor board) transmitted over the DeviceNet - class 4. DeviceNet FEATURES Device Type Generic Master/scanner Explicit peer to peer messaging No I/O Slave messaging supported by ThinkTop DeviceNet I/O peer to peer messaging No Bit strobe No Configuration consistency value No Polling Yes Faulted node recovery No Cyclic No Baud rates 125K, 250K, 500K Change of state (COS) Yes Configuration method EDS

External sensors The external switches are used for seatlift supervision when seatlift can not be internally detected. They get their supply voltage from the sensor board. They connect directly to the terminal strip on the sensor board. If the actual setup is for internal seatlift, the corresponding external signal is not used. Otherwise the external signal logically controls the corresponding feedback to the bus interface unit. Supplyvoltage:...Mustmatchthenetworkpower. Supplycurrent:...Max.15mApersensor. Typeofsensor:...3-wirePNP-type. Cablelength:...max. 3m. Solenoid valves: Up to 3 solenoid valves in each unit. Type...3/2or5/2valve(onlypossiblewithone5/2valve). Airsupply...300-900kPa(3-9bar). Filteredair,max.particlesordirt...5µm5-5mg/m 3. Max.flow...180l/min. Max.oilcontent...1mg/m 3. Max.watercontent...0.88g/m 3-20 o C compressed air. Throughput...ø2.5mm. Airrestriction(throttlefunction)airinlet/outlet...Yes. Manualholdoverride...Yes. Externalairtubeconnection...ø6mmor1/4". Silencer/filter...Connectionpossibleviaø6mmor1/4. (Filter recommended in tropical regions). Solenoid drive: Solenoidvalve...8VDC O/PVoltage...9VDC+/-5% Powerconsumption...0.75WMax. Currentconsumption(persolenoid)...30mAMax. PWMPull-inpulselength...150msMax. PWMdutycycle...40%+/-10% PWMfrequency...2kHz+/-10% PWM = Pulse width modulated Technical specifications aux. outputs Three aux. outputs can be used for external devices. The drivers are always NPN outputs and PWM mode is not possible. The number of aux. outputs for activation of external devices can be 0-3. Clarification: All 3 outputs can be activated at the same time but if solenoid 1 is in use, aux. 1 can not be used! If solenoid 1 and 2 are in use, aux. 1 and 2 can not be used! If solenoid 1, 2 and 3 are in use, no aux. can be used! A mix of solenoid and aux. outputs is possible. Output: NPN (sinking). Output voltage: 24 VDC ± 15%. Network power connection! User must ensure 24 VDC on the network (at the top) when these outputs are used. Load current: Max 75 ma. As these outputs drive constant current, using several node in this mode will reduce the number of node supported by a typical 8A network supply. The user must ensure that total network current consumption is less than the supply rating.

Typical power consumption Test conditions: One ThinkTop DeviceNet 11-25 VDC connected to the network with 1 input (on) and: Nosolenoidson...supplyvoltage25VDC20mA 1solenoidactive(PWM)...supplyvoltage25VDC28mA 2solenoidsactive(PWM)...supplyvoltage25VDC36mA 3solenoidsactive(PWM)...supplyvoltage25VDC44mA Nosolenoidson...supplyvoltage11VDC34mA 1solenoidactive(PWM)...supplyvoltage11VDC58mA 2solenoidsactive(PWM...supplyvoltage11VDC82mA 3solenoidsactive(PWM)...supplyvoltage11VDC106mA Note! If the Aux. Outputs are used instead of the solenoids for activation of external devices, the consumption is depending on the load current (see "Aux. Outputs"). Electrical connection, internal A. Internal connections to solenoid 1-3 ***) B. Bus connection C. Jumper **) D. PNP/NPN jumper ****) E. Incoming signals from external sensor *) 6. Aux. Common (+) 1. Power Bus V-(black) 7. Aux.1 (-) 2. CAN_L (blue) 8. Aux. 2 (-) 3. Drain (bare) 9. Aux. 3 (-) 4. CAN_H (white) 10.N/C 5. Power Bus V+ (red) 11.N/C 12. Jumper Earth 13. Jumper 20.Solenoid common brown 24. Seat-lift 1 upper *) 21.Solenoid 1, blue 25. Seat-lift 2 lower *) 22.Solenoid 2, blue 26. Supply + *) 23.Solenoid 3, blue 27. Supply - *) *) Note! Terminals 24, 25, 26 and 27 can be used for external seatlift sensors as well as for any digital input. They are associated with feedback signal 3 (seatlift 1) and 4 (seatlift 2). External sensor must always be a 8-30 VDC PNP 3 wire sensor. Connect (-) common on terminal 27, and (+) common on terminal 26. **) Note! Jumper present = 7 I/O bytes (Rx size 7 and Tx size 7) - standard. Changing from 7 bytes to 2 bytes: Remove jumper (#12 and #13). A power recycle is necessary when changing byte sizes. ***) Note! Three aux. outputs can be used for external devices. The drivers are always NPN outputs and PWM mode is not possible. The number of aux. outputs for activation of external devices can be 0-3. Clarification: All 3 outputs can be activated at the same time but if solenoid 1 is in use, aux. 1 can not be used! If solenoid 1 and 2 are in use, aux. 1 and 2 can not be used! If solenoid 1, 2 and 3 are in use, no aux. can be used! A mix of solenoid and aux. outputs is possible. Output: NPN(sinking). Output voltage: 24 VDC ± 15%. Network power connection! User must ensure 24 VDC on the network (at the top) when these outputs are used. Load current: Max 75 ma. As these outputs drive constant current, using several node in this mode will reduce the number of node supported by atypical 8A network supply. User must ensure that total net work current consumption is less than the supply rating. ****) Note! If using external sensor, the sensor must be activated when performing a configuration of the sensor board.

18 1. Shell 2. N/A 3. Screw 4. Washer 5. Sensor board 6. Solenoid valve* 7. PT screw 8. Base 9. Special X-ring, grey 10. Air fittings 11. Blow-off valve 12. Thread plug, PG7 13. Cable gland, PG11 14. Gore Vent. membrane 15. Adapter 16. Special X-ring, black 17. O-ring 18. Allen screw 19. Special X-ring 20. Indication pin 6b * 6a: Solenoid valve (3/2) * 6b: Solenoid valve (3/2 or 5/2). 6a TD 800-227 Fig. 1. Basic design, ThinkTop. W Note! This is the basic design. Recommended clearance around the ThinkTop Valve Type H W Unique SSV NC 225 250 SMP-SC/-BC/-TO 225 250 Unique Mixproof 225 250 MH 225 250 SBV 225 250 Unique SSV NO 225 320 LKLA-T 225 300 H 171.6 mm ø137 mm TD 800-205 Fig. 2. Dimensions.

Typical Power Consumption ThinkTop Test conditions = One ThinkTop connected with 1 feedback active (on) and: No solenoids on: Supply voltage 24 VDC 30 ma 1 solenoid active: Supply voltage 24 VDC 75 ma 2 solenoid active: Supply voltage 24 VDC 120 ma 3 solenoid active: Supply voltage 24 VDC 165 ma Note! "Power-on" current is higher. See power supply - DC. Micro environment demand specifications: Temperature Working: -20 C to +85 C IEC 68-2-1/2 Storage: -40 C to +85 C IEC 68-2-1/2 Temperature change: -25 C to +70 C IEC 68-2-14 Vibration 10-55 Hz, 0.7 mm IEC 68-2-6 55-500 Hz, 10g 3x30min,1octave/min Drop test IEC 68-2-32 Humidity Constant humidity: +40 C, 21 days, 93% R.H. IEC68-2-3 Cyclic humidity: +25 C/+55 C 12 cycles (working) 93% R.H. Protection class IP66 and IP67 IEC 529 Input treshold Voltage/current: Type 1 input requirements EN 61131-2 EMC Directive 2004/108/EF EN 61000-6-1, EN 61000-6-2 ODVA Approval DeviceNet v. 2.0 Conformance test version 14 UL Approval 8-30 VDC/AC, class 2 input, 45 ma max. output UL508-E203255 Options - Gore Vent. with adapter (Fig. 1 Basic Design pos. 14) for ThinkTop before November 2006; 9613-4315-01. Accessories - IR keypad. - External indication bracket for SMP-SC. - External indication bracket for Unique Mixproof. Ordering Please state the following when ordering: - DeviceNet. - Number of solenoid valves (0-3). - Type of solenoid valves (3/2 or 5/2). - Air connection ø6 mm or 1/4" - Please state if series 700 valves. - For ThinkTop used on SRC-LS Stop valve size 63.5-101.6 mm/dn 65-100: Special indication pin must be used; 9612-6370-01. - For ThinkTop used on Unique SSV-LS valves: special indication pin must be used; 9613-1581-01. - For ThinkTop used on Unique SSV High Pressure valve size 76.1-101.6 mm / DN 80-100: Special indication pin must be used; 9613-1581-01. Note! For further information: See also ESE000355. The ThinkTop has Patented Sensor System, Registered Design and Registered Trademark owned by Alfa Laval.

. ESE00299EN 1001 The information contained herein is correct at the time of issue, but may be subject to change without prior notice.