Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

Similar documents
Tactile Switch (Hinged Type)

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

Type Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g

Mechanical Key Switch

B3F. Miniature, Space-saving Switch

Subminiature Basic Switch

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

Ordering Information. Text Surface-Mounting Signal Relay G6K

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL.

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Model Number Structure

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Operation angle Return angle Output rating Operating voltage Model 40 to to VDC 2.4 to 3.6 VDC D6BN-1P

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

Safety-door Switch. Ordering Information

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Inductive Proximity Sensor

Model Number Structure

Ordering Information. Text PCB Power Relay G5LE

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

Lighted PushButton Switch

Solid State Relays G3NA. Model Number Structure. Model Number Legend

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

Model Number Structure

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption

MEMS Gauge Pressure Sensor

TURQUOISE STROKE SWITCHES

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

D2AW. Long stroke seal switch with high reliability and high insulation performance. Model Number Legend. Sealed Ultra Subminiature Basic Switch

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend

Turquoise Stroke Switches

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

Low-torque Basic Switch

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

D2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

Pressure sensor with built-in amplification and temperature compensation circuit

List of Models Short post on Long post on left left. Without posts Actuator Terminals Contact form

Manual Reset Limit Switch

D2SW. Sealed Subminiature Basic Switch. Ordering Information Model Number Legend D2SW-

Model Number Structure

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

Small Limit Switch D4V

PCB Relay. New G8P. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

Hinged Safety Door Switch

Safety Limit Switch

Switching Power Supply

Model Number Structure

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

0.6mm Pitch Stacking Height 3mm to 16mm Connectors

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

MCF3 DC86V11CT Inrush-withstand

0.6mm Pitch Stacking Height 3mm to 16mm Connectors

EVERLIGHT ELECTRONICS CO., LTD.

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

Subminiature Basic Switch

Metal Film MELF Resistors

D2MV. Highly reliable Miniature Basic Switch in spite of its Ultra-low Load action. Model Number Legend. List of Models.

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

Turquoise Stroke Mini Switches

Technical Information Solid State Relays. Glossary. Solid State Relays

MCF3 25CT Inrush-withstand

Model Number Structure

D4DL. Guard Lock Safety-door Switch. Model Number Structure

COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY

Ordering Information. Solid State Relay G3NA. New Models with 75-A and 90-A Output Join the Previous Models with 5- to 50-A Output.

Features. Emergency Stop Switch A165E. Separate Construction with Smallest Class of Depth in the World. Safety Lock Prevents Misuse

Transcription:

Tactile Switch A Wide Range of Models: 6 x 6 mm, 1 x 1 mm, Vertical, and High-force. A positive click action plus a long life equal to that of a no-contact switch. Radial models (taping specifications) that allow the use of general-purpose radial taping parts insertion machines have been added to the series. Ordering Information 6 x 6 mm Models Type Plunger Height Operating force (OF) Bags (1 Switches) Without ground With ground Horizontal (-1) Flat Projected 4.3 mm.98 N {1 gf} -1-11 1.47 N {15 gf} -1-11.55 N {6 gf} -15-115 4.9 N {5 gf} -16 (See note.) --- 5. mm.98 N {1 gf} -1-11 1.47 N {15 gf} -1-11.55 N {6 gf} -15-115 4.9 N {5 gf} -16 (See note.) --- 5. mm (7.5-mm pitch).98 N {1 gf} --- -111 7. mm.98 N {1 gf} -16 (See note.) --- 1.47 N {15 gf} -16 (See note.) --- 9.5 mm.98 N {1 gf} -17 (See note.) --- 1.47 N {15 gf} -17-N --- (See note.).55 N {6 gf} -175 (See note.) --- 7.3 mm.98 N {1 gf} -15-115 1.47 N {15 gf} -15-115.55 N {6 gf} -155-1155 4.9 N {5 gf} -156 (See note.) --- 8

Type Plunger Height Operating force (OF) Bags (1 Switches) Without ground With ground Vertical (-3) Flat Projected 3.15 mm.98 N {1 gf} --- -31 1.47 N {15 gf} --- -31.55 N {6 gf} --- -315 3.85 mm.98 N {1 gf} --- -31 1.47 N {15 gf} --- -31.55 N {6 gf} --- -315 6.15 mm.98 N {1 gf} --- -315 1.47 N {15 gf} --- -315.55 N {6 gf} --- -3155 Note: Switches are sold in units of 1 Switches. Orders must be made in multiples of 1 (the quantity per bag). 1 x 1 mm Models Type Plunger (or LED color) Height Operating force (OF) Bags (1 Switches) Without ground With ground Standard (-4) Long life expectancy (-5) High reliability gold-plated (-5) Flat 4.3 mm 1.7 N {13 gf} -4-41.55 N {6 gf} -45-415 Projected 7.3 mm 1.7 N {13 gf} -45-415.55 N {6 gf} -455-4155 Flat 4.3 mm 1.7 N {13 gf} -5-51 Projected 7.3 mm -55-515 Flat 4.3 mm 1.7 N {13 gf} -51-511 Projected 7.3 mm -551-5151 Note: Switches are sold in units of 1 Switches. Orders must be made in multiples of 1 (the quantity per bag). 6 x 6 mm Radial Models (Taping Specifications) Type Plunger Height Operating force:.98 N {1 gf} Radial models (-6) Without ground With ground Without ground Operating force: 1.47 N {15 gf} With ground Flat 4.3 mm -6-61 -6-61 5. mm -6-61 -6-61 Projected 7.3 mm -65-615 -65-615 Note: Switches are sold in units of 1, Switches. Orders must be made in multiples of 1,. Switches are not sold individually. Accessories (Order Separately) Special Key Tops are available for projected plunger models. See page 39. 9

Specifications Ratings/Characteristics Switching capacity 1 to 5 ma, 5 to 4 VDC (resistive load) Ambient temperature 5 C to 7 C (with no icing) Ambient humidity 35% to 85% Contact form SPST-NO Contact resistance 1 m max. (initial value) (rated: 1 ma, 5 VDC) Insulation resistance 1 M min. (at 5 VDC) Dielectric strength 5 VAC, 5/6 Hz for 1 min Bounce time 5 ms max. Vibration resistance Malfunction: 1 to 55 Hz, 1.5 mm double amplitude Shock resistance Destruction: 1, m/s {approx. 1G} max. Malfunction: 1 m/s {approx. 1G} max. Life expectancy -1, -3, -6: 1,, operations min (OF:.98 N) (-17: 5, operations min) 3, operations min (OF: 1.47 N) 1, operations min (OF:.55 N) 5, operations min (OF: 4.9 N) -4: 3,, operations min (OF: 1.8 N) 1,, operations min (OF:.55 N) -5: 1,, operations min. Weight 6 x 6 mm models: approx..5 g 1 x 1 mm models (standard types): approx..85 g Radial models: approx..5 g Operating Characteristics Item Operating force (OF) Operating force (OF) Releasing force (RF) -1, -3, -6-4, -5.98 N 1.47 N.55 N 4.9 N 1.7 N.55 N -1@@ -3@@ -6@@.98.9 N {1 3 gf} -1@@ -3@@ -6@@ 1.47.49 N {15 5 gf} -1@@5-3@@5.55.69 N {6 7 gf} -1@6 4.9 1. 47N {1 3 gf} -4@@ -5@@ 1.7.49 N {13 5 gf} -4@@5.55.69 N {6 7 gf}. N { gf} min..49 N {5 gf} min..49 N {5 gf} min..7 N {7 gf} min..9 N {3 gf} min..49 N {5 gf} min. Pretravel (PT).5 +. /.1 mm.3 +. /.1 mm Engineering Data Operating Force vs. Stroke (Typical) -1, -3, -6-4, -5 Operating force (N) 1.76 1.56 1.37 1.17 OF: 1.47 N Operating force (N).54.35.15 1.96 1.76 1.56 OF:.55 N OF: 1.7 N.98 1.37.78 1.17.98.58.78.39.19 OF:.98 N.58.39.19.1..3.4.5 Stroke S (mm).1..3.4.5 Stroke S (mm) 1

Dimensions Note: 1. All units are in millimeters unless otherwise indicated. Unless otherwise specified, a tolerance of.4 mm applies to all dimensions.. No numbers are indicated on the Switches. The numbers used for s in the following graphics are 3 4 indicated in the Bottom View diagram below. In this diagram, the Switch is rotated so that the s are on the 1 right and left-hand sides, and the OMRON logo appears the right way up. (Bottom View) 6 x 6 mm Models Horizontal, Flat Plunger Type(without Ground Terminal) -1, -1, -15, -16-1 (See note.), -1 (See note.), -15 (See note.), -16 (See note.) Horizontal, Flat Plunger Type(with Ground Terminal, Pitch: 6.5 mm) -11, -11, -115-11 (See note.), -11 (See note.) -115 (See note.) Four 1±.5 * * /Internal Connections Five, 1±.5 Connections * The height of -1, -1, -15, and -16 is 5±. mm. Horizontal, Flat Plunger Type (with Ground Terminal, Pitch: 7.5 mm) -111 * The height of -11, -11, and -115 is 5±. mm. Horizontal, Flat Plunger Type (without Ground Terminal) -16, -16 6±. 6±. 4.5±. 4.5±.1 Four, 1.±.5 1±.5 Connections 7±..5 max. 3.4 6.5±.1 /Internal Connections Four, 1±.5 3.5 6.5±.5 7.7±.5 (1.8).3.7.7 4 3 1 11

Horizontal, Flat Plunger Type (without Ground Terminal) -17, -17-N, -175 6±. Horizontal, Projected Plunger Type (without Ground Terminal) -15, -15-155, -156 6±. 4.5±. 4.5±.1 3 6.5±.1 Four, 1±.5.4.4±.1 Four, 1±.5 9.5 3.5 6.5±.5 7.7±.5.5 max. 3.4 (1.8).3.7.7 Connections 4 3 1 Connections Horizontal, Projected Plunger Type (with Ground Terminal) -115, -115, -1155 Vertical, Flat Plunger Type -31, -31, -315 Two, 1.5±.5 Two, 1±.5.4.4±.1 Five, 1±.5 Connections Connections Vertical, Flat Plunger Type (Height: 3.85 mm) -31, -31, -315 Two, 1.5±.5 Vertical, Projected Plunger Type -315, -315, -3155 Two, 1.5±.5 Two, 1±.5 Connections.4.4±.1 Two, 1±.5 Connections 1

1 x 1 mm Models Flat Plunger Type (without Ground Terminal) -4, -45, -5, -51 Two, 1.8±.5 (For positioning boss) Flat Plunger Type (with Ground Terminal) -41, -415, -51, -511 Two, 1.8±.5 (For positioning boss) 7.1 Four, 1.±.5 Connections 7.1 Five, 1.±.5 Connections Projected Plunger Type (without Ground Terminal) -45, -455, -55, -551 Two, 1.8±.5 (For positioning boss) Projected Plunger Type (with Ground Terminal) -415, -4155, -515, -5151 Two, 1.8±.5 (For positioning boss) 3.8 3.8±.1 7.1 Four, 1.±.5 3.8 3.8±.1 7.1 Connections Five, 1.±.5 Connections 13

6 mm 6 mm Radial Types (Taping Specifications): Sold in Units of 1, Switches Flat Plunger Type (without Ground Terminal) -6, -6 Surface A Surface B 6 6 max. Support tape PCB Mounting /Internal Connections 4±.3 Carrier tape +.1 Two, 1 Note: The tape is random between surface A and surface B. Flat Plunger Type (with Ground Terminal) -61, -61 6 6 max. Support tape PCB Mounting /Internal Connections 4±.3 Carrier tape +.1 Three, 1 Flat Plunger Type (without Ground Terminal) -6, -6 6±.3 6±.3 Surface A Surface B Support tape 6.35±1 6 6 1.7±1 9 3.4 5 +1 18 max. 5 3.4 6.9 +1 18.5.6 5±. PCB Mounting.3 /Internal Connections 4±.3 5±. 3.85±.5 1.7±.3 1.7±.3 Carrier tape +.1 Two, 1 5±.1 Note: The tape is random between surface A and surface B. 14

Flat Plunger Type (with Ground Terminal) -61, -61 6±.3 6±.3 6.35±1 6 6 1.7±1 max. 4.3 3.4.6 +.1 Three, 1 5±. 3.1 5±. PCB Mounting 5±.1 5±.1 5 3.4.9.3.6 /Internal Connections Support tape 4±.3 5±. 3.85±.5 1.7±.3 1.7±.3 11 6 ±.5 Carrier tape +1 18.5 Projected Plunger Type (without Ground Terminal) -65, -65 Surface A 6 6 max. Surface B.4.4 Support tape PCB Mounting /Internal Connections 4±.3 Carrier tape +.1 Two, 1 Note: The tape is random between surface A and surface B. Projected Plunger Type (with Ground Terminal) -615, -615.4.4 6 6 max. Support tape PCB Mounting /Internal Connections 4±.3 +.1 Three, 1 Carrier tape Key Tops B3-series Special Key Tops are available for projected plunger models. Refer to page 4 for details. Precautions Be sure to read the precautions common to all Tactile Switches on pages 5 to 7 for correct use. 15

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by.3937. To convert grams into ounces, multiply by.357. Cat. No. A7-E1-5 16

Tactile Switch Key Top B3 Key Top Designed Specially for Projected-plunger-type, S, and B3W Switches Available in a wide range of colors and sizes. RoHS Compliant (Refer to page 8 for details.) Ordering Information For, S, and B3W Switches Color 6 6 mm Switches (-1, -3, -6, B3W-1, S) 4 4 mm Key Top 6 mm Key Top D-type Key Top 9 9 mm Key Top 1 1 mm Switches (-4, -5, B3W-4) 1 1 mm Key Top 9.5-mm Light gray B3-1 B3- B3-1 B3-1 B3-13 B3-16 Black B3-11 B3-1 B3-11 B3-11 B3-131 B3-161 Orange B3-1 --- --- B3-1 B3-13 B3-16 Yellow B3-13 --- --- B3-13 B3-133 B3-163 Blue B3-14 --- --- B3-14 B3-134 --- White B3-16 --- --- B3-16 B3-136 --- Red B3-18 --- --- B3-18 B3-1388 --- Note: The minimum order unit is 1, Switches per package. Orders must be made in multiples of the minimum order unit. Specifications Characteristics Ambient operating temperature Ambient operating humidity 5 C to 7 C at 6% max. humidity (with no icing or condensation) 35% to 85% (at 5 to 35 C) 4

B3 B3 Dimensions Note: All units are in millimeters unless otherwise indicated. Unless otherwise specified, a tolerance of ±.4 mm applies to all dimensions. B3-1@ R. Reference Dimensions Cutout 5.5.8 1. to. 1. to. 4±.15 1.6 R.5.5 +.15.5 1.±.4 4 4. +.5 4. +.5.3.5 +.15.5 4±.15 8.85±. B3- B3-1 R. Reference Dimensions Cutout 1. to. 5.5±.1.8 1. to. 6.5 +.5 6±.1.5 1±.4 4 1.8.5 8.85±.4 B3-1 B3-11 R. Reference Dimensions Cutout 1. to. 5.5±.1 6±.1 6±.1.7 1.8 R.5.8 1±.4 1. to. 4 Two, R.75 +.5 6.5 +.5.95 +.5 Two, R1.5 +.5 R.5 +.5 6.5 +.5.5 8.85±.4 B3-1@ R. Reference Dimensions Cutout 5.5.8 1. to. R.5 1.±.4 9. +.5 9. +.5 9±.15 3.8±.1 3.8±.1 9±.15 43

B3 B3 B3-13@ R. Reference Dimensions Cutout 5.5.8 1. to. 1.8 R.5 1.±.4 1. +.5 1. +.5 1±.15 3.8±.1 3.5 3.8±.1 1±.15 B3-16@ Reference Dimensions Cutout 7.8 1. to. 9.7 +.5 9.5±. 11.5±.4 3.8±.1 3.55 3.8±.1 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by.3937. To convert grams into ounces, multiply by.357. Cat. No. A77-E1-4 44

Precautions Precautions Safety Precautions Precautions for Safe Use Use the Switch within the rated voltage and current ranges, otherwise the Switch may have a shortened life expectancy, radiate heat, or burn out. This particularly applies to the instantaneous voltages and currents when switching. Precautions for Correct Use Storage To prevent degradation, such as discoloration, in the s during storage, do not store the Switch in locations that are subject to the following conditions. 1. High temperature or humidity. Corrosive gases 3. Direct sunlight Handling 1. Operation Do not repeatedly operate the Switch with excessive force. Applying excessive pressure or applying additional force after the plunger has stopped may deform the disc spring of the Switch, resulting in malfunction. In particular, applying excessive force to Side-operated Switches may damage the caulking, which in turn may damage the Switch. Do not apply force exceeding the maximum (9.4 N for 1 minute, one time) when installing or operating Side-operated Switches. Be sure to set up the Switch so that the plunger will operate in a straight vertical line. A decrease in the life of the Switch may result if the plunger is pressed off-center or from an angle. Do not solder the Switch more than twice, including rectification soldering. An interval of five minutes is required between the first and second soldering.. Automatic Soldering Baths (, B3W, B3WN, B3M, B3J) Soldering temperature: 6 C max. Soldering time: 5 s max. for a 1.6-mm thick single-side PCB Preheating temperature: 1 C max. (ambient temperature) Preheating time: Within 6 s Make sure that no flux will rise above the level of the PCB. If flux overflows onto the mounting surface of the PCB, it may enter the Switch and cause a malfunction. 3. Reflow Soldering (Surface Mounting) Solder the s within the heating curve shown in the following diagram. B3S, B3SN, S Temperature ( C) Max. 5 18 PCB surface Flux surface Operating part Plunger 15 Preheating. Dust Protection Do not use Switches that are not sealed in dust-prone environments. Doing so may cause dust to penetrate inside the Switch and cause faulty contact. If a Switch that is not sealed must be used in this kind of environment, use a sheet or other measure to protect it against dust. PCBs The Switch is designed for a 1.6-mm thick, single-side PCB. Using PCBs with a different thickness or using double-sided, through-hole PCBs may result in loose mounting, improper insertion, or poor heat resistance in soldering. These effects will occur, depending on the type of holes and patterns of the PCB. Therefore, it is recommended that a verification test is conducted before use. If the PCBs are separated after mounting the Switch, particles from the PCBs may enter the Switch. If PCB particles or foreign particles from the surrounding environment, workbench, containers, or stacked PCBs become attached to the Switch, faulty contact may result. Soldering Incorrect Incorrect Correct Resin sheet Switch 1. General Precautions Before soldering the Switch on a multilayer PCB, test to confirm that soldering can be performed properly. Otherwise the Switch may be deformed by the soldering heat on the pattern or lands of the multilayer PCB. Note: The above heating curve applies if the PCB thickness is 1.6 mm. The peak temperature may vary depending on the reflow bath used. Confirm the conditions beforehand. Do not use an automatic soldering bath for surface-mounted Switches. The soldering gas or flux may enter the Switch and damage the Switch s push-button operation. 4. Manual Soldering (All Models) Soldering temperature: 35 C max. at the tip of the soldering iron Soldering time: 3 s max. for a 1.6-mm thick, single-side PCB Before soldering the Switch on a PCB, make sure that there is no unnecessary space between the Switch and the PCB. Washing Room temperature 6 to 1 1. Washable and Non-washable Models Max. 6 Time (s) Washable (sealed types) B3W, B3WN, B3S, B3SN Non-washable (standard types), S, B3M, B3J, B3DA, B3D Standard Switches are not sealed, and cannot be washed. Doing so will cause the washing agent, together with flux or dust particles on the PCB, to enter the Switch, resulting in malfunction. 5

Precautions Precautions. Washing Methods Washing equipment incorporating more than one washing bath can be used to clean washable models, provided that the washable models are cleaned for one minute maximum per bath and the total cleaning time does not exceed three minutes. 3. Washing Agents Apply alcohol-based solvents to clean washable models. Do not apply any other agents or water to clean any washable model, as such agents may degrade the materials or performance of the Switch. +.1 1.5 8±.1 4±.1 1.75±.1 5.5 1±.3 A Model S-1P S-1P A 3.9 mm B3SN 3.6 mm 4. Washing Precautions Do not impose any external force on washable models while washing. Do not clean washable models immediately after soldering. The cleaning agent may be absorbed into the Switch through respiration as the Switch cools. Wait for at least three minutes after soldering before cleaning washable models. Do not use Sealed Switches while submersed in water or in locations exposed to water. Switch Packaging (Taping Specification Models) Standards Package Heat resistance Conforms to JEITA. 3, Switches 5 C for 4 hours (without deformation) Note: Switches with ground s are packaged with the ground on the opposite side of the guide hole. S-11P () Label 1. Radial Types The tape is packaged by fan-folding into the box, as shown in the following diagram. Switches on taping Packaging box Reel (Made of paper) 13 33 Fan-folded tape C 1.5 +.1 1±.1 4±.1 1.75 (4.7) A B 7.5 16 Model A B C 5 mm 35 mm 75 mm B3WN 53 mm 36 mm 35 mm Do not apply any external force to the packaging box, or subject it to vibration. Doing so may deform the Switch s. Remove the tape slowly, making sure that the Switches are not entangled or caught. Otherwise the s may be deformed. Do not store the packaged Switches in locations subject to high temperatures or high humidity. The packaging boxes are sealed with paper tape and are not airtight. Storing the packaged Switches in locations with high temperature or high humidity may result in deterioration of the tape and Switches, and long-term storage under such conditions may cause discoloration of the Switch s.. Packaging Specifications for Embossed Taping (S-1P/-1P, B3SN) (18) Label Standards Package Heat resistance Conforms to JEITA. 1, Switches 6 C for 4 hours (without deformation) Reel 13 38± 6

Precautions Precautions S-15P () Label LEDs (B3J) Make sure that the polarity of the LEDs is correct. The polarity is not indicated on the Switch, but the positive pole is located on the back surface of the Switch on the side without the OMRON mark. Connect limiting resistors to the LEDs. The Switch does not have built-in limiting resistors, so satisfy the LED characteristics by obtaining the limiting resistance according to the following formula based on the voltage to be used. 13 Reel (made of paper) 38± Limiting resistance (R)= (Voltage used (E) LED forward voltage (VF)) LED forward current (IF) (Ω) +.1 1.5 1±.1 4±.1 1.75±.1 (8.1) R E VF IF 7.5 16±.3 Standards Package Heat resistance Conforms to JEITA. 1, Switches 6 C for 4 hours (without deformation) Forward current I F (ma) 5 4 3 Red Yellow/Green B3S 33 1.5 1 13 4 6 8 Ambient temperature Ta ( C) Reel +.1 1.5 1±.1 4±.1 Label 1.75 Forward current IF (ma) 5 3 1 5 Green Yellow 3 8.7 7 7.5 16 1 Red.6 9.4 1.5.4.5 1.5 1.6 1.7 1.8 1.9..1 Forward voltage V F (V) 4.7 Standards Package Heat resistance Conforms to JEITA. 1, Switches 5 C for 4 hours (without deformation) Note: Switches with ground s are packaged with the ground on the opposite side of the guide hole. 7