LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

Similar documents
Illuminator Series CR NEMA 3R

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

EMEX. Central Battery Systems Emergency Lighting

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 10KW 33KW Systems

STL. Series. Emergency Lighting Inverter 3kW to 160kW Central System

GLX. Series. 1kW to 16kW Central System

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 40KW 55KW Systems

INTRODUCING THE NEW MINI INVERTERS BY READY-LITE

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

TECHNICAL GUIDE SPECIFICATIONS

RELIABILITY THROUGH TECHNOLOGY

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

POWER WAVE 1 SINGLE-PHASE, (3 TO 20 KVA) & (3 TO 17 KW) UL924 CENTRAL LIGHTING INVERTER

Crucial Power Products

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

systems Systems Emergency Lighting Inverter 120 or 277V 60 Hz Power

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Table of Contents. Pg. 2

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Aurora Single Phase Emergency Lighting Inverters

MINUTEMAN UPS Endeavor Series Product Specifications 5,000VA 10,000VA Single-Phase Uninterruptible Power Supply 1.0 GENERAL

DPP/3DPP. Digital ProcessPower UPS INDUSTRIAL PWM UNINTERRUPTIBLE POWER SUPPLY SYSTEM SINGLE PHASE THREE PHASE

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Lumencia. LLMPS SERIES Micro Power Systems. Multi-Unit Residential Lighting. Job Name: Type:

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Special Specification 6058 Battery Back-Up System for Signal Cabinets

Solar Inverter Manual

TECHNICAL DATA SHEET KVA UPS Systemss

PowerValue 11/31 T kva

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

MINUTEMAN POWER TECHNOLOGIES Endeavor LCD Series Product Specifications 1000VA 3000VA Single-phase Uninterruptible Power Supply 1.

Contractors Guide Central Inverter System Installation

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

TECHNICAL GUIDE SPECIFICATIONS

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Product Specifications

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

POWER kva

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III

Uninterruptible Power Systems

Illuminator System Series CIII

Options & service. Additional 9355 options. Proven warranty and support services. Extensive service options for enhanced reliability.

Technical Data Sheets

CEPS Series UL924 Emergency Lighting Inverters

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

POWER kva

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

Technical Data Sheets

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Alphapower HTU UPS. Some key features include:

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

D Series: UPS UPTO - 300KVA - Three / Three Phase

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

3 Uninterruptible Power Systems

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SURE-LITES LIFEWAY II SERIES

TRIMOD HE UPS. MODULAR THREE-PHASE UPS from 10 to 80 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Technical data sheets

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

PowerWAVE EL. (Single-phase 500 VA 30 kva. Three-phase kva)

Automatic DC Power Supply/Battery Charger

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

3 Uninterruptible Power Systems

On-line, Single Phase, Double Conversion UPS

Liebert GXT VA RT230 Rack-Tower model GUIDE SPECIFICATIONS 1.0 GENERAL

DLTC. lighting controls. transfer circuit for use with low-voltage down-lighting. features

Application. Battery. Public Grid GS HYBRID INVERTER

3 Uninterruptible Power Systems

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Technical Data Sheets

UPS. MODULAR from 10 to 60kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

Technical Data Sheets

MKN-DSP SERIES - THREE PHASE

Technical Data Sheets

Features and Benefits

Technical Data Sheets

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Transcription:

LiteMinder Fast Transfer System 1.0 to 18.75KVA LED Compatible Series Inverter Pure Sine Wave Modular Inverter Technology Modular AC System Evenlite s LiteMinder Central Inverter System provides an innovative Emergency Lighting solution for today s complex energy saving systems, light sources and maintenance requirements. The LiteMinder represents the pinnacle of engineering excellence with features not found in the traditional systems currently available: Modularity: LiteMinder features unique inverter modules available in increments from 1.0 to 18.75 KVA capacities(see ordering guide). Modules are interconnected to build the required system capacity, and can even be field upgraded to increase system sizes! Modules can be configured to provide Single Phase, Split Phase, and Three Phase outputs thereby eliminating costly, inefficient external transformers. Control Features: A keypad and LCD display provides user interface and extensive status diagnostics. Self-test, Self-Diagnostics in compliance with UL 924 is field configurable, and stores 1,000 Test, Event and Alarm logs thereby eliminating the need for costly manual test and data recording. Web Site Monitoring: unique web interface constantly monitors the system status and records all essential data. Users can log on, view, interact and download records as needed. The factory can also monitor, diagnose remotely. Diagnostics: In addition to Self-test, Self- Diagnostics, LiteMinder also includes unique startup diagnostics to aid in installation and maintenance: Eight individual startup alarms (Communications, Set-Up Conflict, Low Battery, Back-feed, Transfer/AC Fuse, Short/Overload, Miswire, Incorrect AC Input) eight individual Charger Alarms and eight individual Inverter Alarms. ARRA Compliant for Levels 1&2 Project name: Approved By: 2575 Metropolitan Drive, Trevose, PA 19053 USA TEL: (800) 872 0879 FAX:(215) 244 4208 Catalog No: Type No:

PWM MOSFET and IGBT ( Dependant) Inverter provide Pure Sine Wave output with less than 3% THD, and fully compatible with LED Lighting Loads Fast transfer for H.I.D. compatibility ensures smooth operation of combined lighting loads, transfers in less than 2 ms Modular inverter allows operation for single phase or three phase operation to order Less than 3% THD, load power factor 0.5 Lag to 0.5 Lead, 98% efficient in standby mode Automatic Low Voltage Disconnect (LVD) set at 1.67 VPC Automatic restart upon utility power return, no need to manually reset the system Input circuit breaker is provided sized to system rating Shorted circuit protected to 65KAIC tested and approved to UL 6180-5-1 standard UL924 compliant Self-Test/Self-Diagnostics are standard, with interactive LCD display Monthly and the annual 90 minute test can be programmed by the user for a specific date and time to ensure NFPA Code Compliance Up to 1000 events stored in the memory log on a FIFO basis, and is easily accessible thru the MMI MMI (Man-Machine Interface) consists of a 5 button keypad for easy menu navigation A 4x20 backlit White display with heads-up LED s allow for a quick diagnosis of the system status and alarms Five LED indicators provide the status of the Inverter, Charger, AC present, Ready, and Switched Load (if provided with Switched Output Circuit Breakers) An additional six LED indicators provide the alarm status for Alarm Summary, Bypass (if equipped with Maintenance Bypass option), CB Trip, Startup Fault, Charger Fault, and Inverter Fault A dedicated System Test button is provided for a user initiated 30 second on demand test An Alarm On/Off LED is provided to indicate that an audible alarm is present. A dedicated Alarm Silence On/Off push button allows the user the silence the audible alarm SD card slot allows the user to download all Test, Event and Alarm Logs The Meter Menu allows the user to access the Input and Output Voltages, Output Current, Output VA, Battery Voltage, Battery Current, Battery Power, Temperature, System Days, Inverter minutes and Inverter Events Crest factor >4 for high inrush demanding loads, overload 120 percent for 10 minutes, 400 percent for 500mS The inverter and battery cabinets are constructed from 14 gauge CRS and are powder painted with no visible outside bolts or hardware Internally the inverter has all galvanized or painted steel parts for all modules and shelves to resist corrosion and provide high durability Installer friendly front mounted battery terminals for easier and faster installation VRLA Maintenance Free Lead Calcium Battery s provide the required 90 minute minimum run time Battery recharge time is less than 24 hours, meets all UL 924 and NFPA101 Life Safety Code requirements Operating temperature 20 to 30 C Three Rate Charger circuit is fully temperature compensated for added reliability Brownout protection set for 85% of the nominal line voltage Electronics are warranted for 2 years and the VRLA batteries have a 10 year warranty, optional factory startup increases the warranty to 3 years Listed to UL924, and meets NFPA101 Life Safety Code, NFPA70-NEC and OSHA Requirements,1.0-2.8KVA models meet CSA C22.2 No. 141-10 Warranty: (For full warranty details see warranty data sheet CPS-WAR) Electronics: Evenlite Inc. warrants the series electronics assembly (except batteries) against defects in material and workmanship for a period of two years or three years with Factory Startup option. Battery: Evenlite Inc. warrants the LC series Lead Calcium batteries carry a 1 year full, 9 year pro-rated limited warranty. -MOD 10 /17

ORDERING GUIDE Single Phase VA Rating Phase Configuration Input Voltage Output Voltage Output Breaker Configuration s 1000 VA 1600 VA 2200 VA 2800 VA 3000 VA 4200 VA 5200 VA 6250 VA 8250 VA 10500 VA 12500 VA 1P Single Phase 120 or 277(L-N) IA IB 120V (L-N) 277V (L-N) OA 120V (L-N) OB 277V (L-N) *C(n) 20A Normally On Output Breaker *O(n) 20A Normally Off Output Breaker *S(n) 20A Switched Output Breaker (n) = Quanity Required BB Indicates Special Breaker Current Requirement, Contact Factory Quantity Limitations (Any combination of output types) 1000VA 8 x 20 A without TA option 4 x Normal Off With or Without TA 4 x Switched With or Without TA 5 x 20A with TA 1600-3000VA 12 x 20 A without TA option 4 x Normally off With or Without TA 4 x Switched With or Without TA 8 x 20A with TA 4200-12500VA 24 x 20 A without TA option 6 x Normally Off With or Without TA 6 x Switched With or Without TA 16 x 20A with TA *TA TB MB DT Z4 M(n) EW FS WM Trip Alarm for all circuit breakers 1 Summary / 2 programmable terminal block for form C dry contacts Maintenance Bypass Switch (make before break) Delayed Transfer, 60 ms Seismic Zone 4 certified Maintenance Plan, n= years (5 max.) Extended Warranty to 5 Years (EW requires FS) Startup commissioning on Site Wall Mount Kit (1KW only) *Maximum Number of Breaker Trip Alarms Dependant Example: -12500-1P-IB-OB-S4-TA-FS No of s Width Height Depth Weight Inverter *Weight Battery **Total Shipping Weight Max. BTU s/ Hr. at Full Load 1000 1 24 38 13 308 lbs. N/A 343 lbs. 68 1600 1 32 52 13.75 522 lbs. N/A 552 lbs. 109 2200 1 32 52 13.75 600 lbs. N/A 635 lbs. 150 2800 1 32 52 13.75 678 lbs. N/A 713 lbs. 190 3000 1 32 52 13.75 696 lbs. N/A 731 lbs. 209 4200 1 32 50 23 980 lbs. N/A 1,030 lbs. 286 5200 1 32 50 23 1,140 lbs. N/A 1,190 lbs. 355 6250 1 32 50 23 1,300 lbs. N/A 1,350 lbs. 426 8250 2 32 50 23 375 lbs. 1,570 lbs. 2,020 lbs. 563 10500 2 32 50 23 375 lbs 1,890 lbs. 2,340 lbs. 716 12500 2 32 50 23 375 lbs. 2,210 lbs. 2,660 lbs 852 * Battery cabinet weight is with batteries installed ** Total shipping weight includes pallets and packaging -MOD 10/17

ORDERING GUIDE Split & Two Phase VA Rating Phase Configuration Input Voltage Output Voltage Output Breaker Configuration s 2200 VA 4200 VA 5200 VA 6250 VA 8250 VA 10500 VA 12500 VA 1S 2P Split Phase Two Phase ID IC IE 120V/120V/240V L-N / L-N / L-L 3 Wire + Ground 120V/120V/208V 277V/277V/480V L-N / L-N / L-L 3 Wire + Ground OD 120V/120V/240V L-N / L-N / L-L 3 Wire + Ground OC 120V/120V/208V OE 277V/277V/480V L-N / L-N / L-L 3 Wire + Ground *C(n) 20A Normally On Output Breaker *O(n) 20A Normally Off Output Breaker *S(n) 20A Switched Output Breaker (n) = Quanity Required BB Indicates Special Breaker Current Requirement, Contact Factory Quantity Limitations (Any combination of output types) *TA TB MB DT Z4 M(n) EW FS Trip Alarm for all circuit breakers 1 Summary / 2 programmable terminal block for form C dry contacts Maintenance Bypass Switch (make before break) Delayed Transfer, 60 ms Seismic Zone 4 Certified Maintenance Plan, n= years (5 max.) Extended Warranty to 5 Years (EW requires FS) Startup commissioning on Site 4200-10500VA 24 x 20 A without TA option 6 x Normally Off With or Without TA 6 x Switched With or Without TA 16 x 20A with TA *Maximum Number of Breaker Trip Alarms Dependant Example: -12500-2P-ID-OD-S4-TA-Z4-FS No of s Width Height Depth Weight Inverter *Weight Battery **Total Shipping Weight Max. BTU s/ Hr. at Full Load 2200 2 24 38 13 180 lbs 420 lbs. 670 lbs. 150 4200 2 32 50 23 350 lbs. 680 lbs. 1,030 lbs. 286 5200 2 32 50 23 350 lbs. 840 lbs. 1,190 lbs. 355 6250 2 32 50 23 350 lbs. 1,000 lbs. 1,350 lbs. 426 8250 2 32 50 23 375 lbs. 1,570 lbs. 2,020 lbs. 563 10500 2 32 50 23 375 lbs 1,890 lbs. 2,340 lbs. 716 12500 2 32 50 23 375 lbs. 2,210 lbs. 2,660 lbs 852 * Battery cabinet weight is with batteries installed ** Total shipping weight includes pallets and packaging -MOD 10/17

ORDERING GUIDE Three Phase VA Rating Phase Configuration Input Voltage Output Voltage Output Breaker Configuration s 3000 VA 5200 VA 8250 VA 10500 VA 12500 VA 15750 VA 18750 VA 3P Three Phase 120/208 or 277/480 IF 120V/208 L-N//L-L IG 277V/480V L-N/L-L 4 wire + Ground OF 120V/208 L-N//L-L OG 277V/480V L-N/L-L 4 wire + Ground *C(n) 20A Normally On Output Breaker *O(n) 20A Normally Off Output Breaker *S(n) 20A Switched Output Breaker *(n) = Quantity Required BB Indicates Special Breaker Current Requirement, Contact Factory Quantity Limitations (Any combination of output types) 3000VA 6 x 20 A without TA option 3 x Switched With or Without TA 3 x 20A with TA 4200-5200VA 12 x 20 A without TA option 6 x Switched With or Without TA 8 x 20A with TA 8250-18750VA 24 x 20 A without TA option 6 x Switched With or Without TA 16 x 20A with TA *TA TB MB DT Z4 M(n) EW FS Trip Alarm for all circuit breakers 1 Summary / 2 programmable terminal block for form C dry contacts Maintenance Bypass Switch (make before break) Delayed Transfer, 60 ms Seismic Zone 4 Certified Maintenance Plan, n= years (5 max.) Extended Warranty to 5 Years (EW requires FS) Startup commissioning on Site *Maximum Number of Breaker Trip Alarms Dependant Example: -15750-3P-IG-OG-S6-TA-MB-FS No of s Width Height Depth Weight Inverter *Weight Battery **Total Shipping Weight Max. BTU s/hr. at Full Load 3000 2 24 38 13 218 lbs. 576 lbs. 820 lbs. 205 5200 2 32 50 23 565 lbs. 1,060 lbs. 1,890 lbs. 355 8250 2 32 50 23 565 lbs. 1,532 lbs. 2,210 lbs. 563 10500 2 32 50 23 565 lbs. 1,850 lbs. 2,530 lbs. 716 12500 3 32 50 23 565 lbs 2,161 lbs. 2,850 lbs. 853 15750 3 32 50 23 565 lbs. 2,908 lbs. 3,630 lbs. 1,074 18750 3 32 50 23 565 lbs. 3,380 lbs. 4,120 lbs. 1,279 * Battery cabinet weight is with batteries installed ** Total shipping weight includes pallets and packaging -MOD 10/17

Overall Mechanical Dimensions 1KVA Single 24 17.25 2.50 4x 2.50 16x dual knockout 1-1/8 and 7/8 dia. 2x 1.75 Top 24 AC Breaker Panel 3 feet minimum clearance in front of all units 13 6x 2.0 38 30.3 21.6 Man Machine Interface Panel Right Side 4x 1.75 24.5 38 Master Inverter 4.0 2.5 6.5 Bracket, Floor Mounting Inter-cabinet Battery Cable Ports for Vertical Mounting Mounting Slot See Detail.75 x 2.13 Slot for Floor Mounting 9.97 Knockout pattern identical to left side 1.38.31 Dia. holes for 1/4 hardware Floor Mounting Brackets and to Vertical Mounting Mounting Slot Detail 21.00 Floor Mounting Bolt Pattern 1.5 1.5 -MOD 10/17

Overall Mechanical Dimensions1.6-3.0 KVA Single 6x.88 and 1.13 knockouts for AC connection 2.50 32.00 27.00 2x 2.50 2x 1.75 2x 1.75 13.75 9.75 2.00 36.00 min. clearance in front of all units 12 Circuit Breaker Panel location 16.00 7.86 MMI Interface Panel 4x.88 and 1.13 knockouts each side of cabinet 45.00 55.00 45.87 35.53 6.50 4.00 1.50 29.00 4x.76 x 2.26 slot 2x 10,46 1.71 Floor Mounting Bolt Pattern -MOD 10/17

Overall Mechanical Dimensions 4.2 to 18.75KVA 23.0 36 Min. Clearance in front of all units 12 Circuit Breaker Panel location 32.0 MMI Interface Panel 50.0 36.3 Inverter 37.6 4.0 4200-6250 single phase uses a single cabinet for inverter and batteries 26.84 2.57 Battery Connection Knockout locations 23.0 36 Min. Clearance in front of all units 24 Circuit Breaker Panel location 32.0 MMI Interface Panel 32.0 2x 6.64 4.86 Floor Mounting Bolt Battery Pattern No. 1 2x 13.28 O.40 6x per cabinet mounting holes 32.0 Battery No. 2 50.0 37.6 28.3 Inverter 4.0 8250-12500 single phase requires two cabinets (inverter 5.16 and batteries) 3x 26.84 5200-12500 three phase requires two cabinets (inverter and batteries) Configuration Single Phase 16-24 Batteries - 1 Inverter cabinet, 1 Battery cabinet 15750-18750 three phase requires three cabinets (inverter and batteries) Three Phase 8-24 Batteries - 1 Inverter cabinet, 1 Battery cabinet Three Phase 30-36 Batteries - 1 Inverter cabinet, 2 Battery cabinets 2.57 2x 6.64 2x 13.28 Floor Mounting Bolt Pattern O.40 6x per cabinet mounting holes 4.86 -MOD 10/17