for Power Generation Standby Applications with air-to-air charge air cooling

Similar documents
for Power Generation Standby Applications with water-to-air charge air cooling

for Power Generation Continuous/Prime/Peak Applications with air-to-air charge air cooling

for Power Generation Continuous/Prime/Peak Applications with water-to-air charge air cooling

Sales Program Gendrive

Sales Program Gendrive

Sales Program Oil & Gas Industry

Marine. Series 2000 Diesel Engines for Marine Applications

Commercial Marine. MTU Generator Sets. Power. Passion. Partnership.

DIESEL GENERATOR SET MTU 16V2000 DS1100

DIESEL GENERATOR SET MTU 16V2000 DS KVA

DIESEL GENERATOR SET MTU 16V2000 DS1000

DIESEL GENERATOR SET MTU 12V1600 DS660

DIESEL GENERATOR SET DG00660D5

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 20V4000 DS3250

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 20V4000 DS2650

DIESEL GENERATOR SET MTU 18V2000 DS1400

DIESEL GENERATOR SET MTU 10V1600 DS500

DIESEL GENERATOR SET DP03000D5S

POWER MODULE MTU 16V4000 DS2560

DIESEL GENERATOR SET MTU 12V4000 DS2250

DIESEL GENERATOR SET MTU 12V4000 DS1750

Marine Commercial, Yacht. MTU Series 4000 M05 IMO II/ IMO III/ EPA Tier 4. Power. Passion. Partnership.

DIESEL GENERATOR SET MTU 16V4000 DS2500

MTU Friedrichshafen. MTU Project No. - ENGINE DATA - Printout: (y-m-d) Sheet 1

DIESEL GENERATOR SET MTU 20V4000 DS4000

DIESEL GENERATOR SET MTU 12V4000 DS2000

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET MTU 20V4000 DS3100

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET MTU 20V4000 DS3600

2500 Prime 2100 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

DIESEL GENERATOR SET DS03200D5S

DIESEL GENERATOR SET MTU 12V4000 DS1650

DIESEL GENERATOR SET DS01650D5S

DIESEL GENERATOR SET MTU 12V4000 DS1650

DIESEL GENERATOR SET MTU 4R0113 DS80

Sales Program C&I, Agriculture, Mining

DIESEL GENERATOR SET DP01800D5S

DIESEL GENERATOR SET MTU 16V4000 DS2250

Technical data TAD1242GE. General

Technical data TAD1241GE. General

Ultra-low sulphur diesel (15 ppm sulphur)

Off-Highway engines by MTU. Tougher whatever the conditions. Series 1000 Series 1600 EU Stage IV/EPA Tier 4 final. Construction & Industrial, Mining

Diesel engine D 2866 LE20x Technical Data

DIESEL GENERATOR SET MTU 20V4000 DS3300

VIRTUS Diesel Gensets

A TOGNUM GROUP BRAND

PRODUCT PRESENTATION. MTU ONSITE ENERGY DIESEL GENERATOT SET kVA BASED SERIES MTU Onsite Energy GmbH All rights reserved

1000 Series 1004G Diesel Engine ElectropaK Belt-Driven Coolant Pump

Technical Sales Document

912. The Genset Engine.

2500 Prime 2200 Continuous

Technical Sales Document

Off-Highway engines by MTU. Tougher whatever the conditions. Series EU Stage IV/EPA Tier 4 final. Agriculture and Forestry

Generator set data sheet Prime. Fuel consumption. Engine Standby rating Prime rating Continuous rating. Fuel flow

1013ec. The engine for construction equipment.

1013. The engine for construction equipment.

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

POWERBLOCK GENERATION SYSTEMS

Power Rating Minimum Power 218 bkw 292 bhp Maximum Power 359 bkw 482 bhp mm (5.4 in) mm (6.5 in)

4000 Series TAG3A Diesel Engine ElectropaK rpm

See Note. 100% of rated load. Mechanical efficiency ISO3046/1 2,4,7 35.2% 34.8% 34.1% Electrical efficiency ISO3046/1 2,4,6,7 33.7% 33.4% 32.

See Note. 100% of rated load

VOLVO PENTA GENSET ENGINE TAD531GE

Réf GB / e ALTERNATORS. LSA Pole. Electrical and mechanical data

See Note. 100% of rated load

See Note. 100% of rated load

1100 Series 1103A-33TG2 Diesel Engine ElectropaK 67.5 kwm / rpm

PRODUCT PRESENTATION SERIES kva. MTU Onsite Energy Systems GmbH All rights reserved

1013. The engine for construction.

2000 Series 2206C-E13TAG2 Diesel Engine ElectropaK rpm

1012. The engine for construction equipment kw at min -1

See Note. 100% of rated load

Sales Program C&I, Agriculture, Mining

DEUTZ Engine Documentation Genset Manual. BF4M2012C (D2OC74,9) - 50 Hz 1/5 DEUTZ AG

1100 Series 1104A-44TG1 Diesel Engine ElectropaK 75.5 kwm / rpm

4000 Series 4008TAG2 Diesel Engine Electro Unit rpm net standby power

1135 Prime 1000 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2

7,15 436, Bore , ,12 Compression ratio. 17 Wet weight

MTU Friedrichshafen 3B

7,15 436, Bore , ,12 Compression ratio. 18 Wet weight

2800 Series 2806C-E18TAG1A Diesel Engine ElectropaK 598 kwm at 1800 rpm

60 Hz FEATURES. Exclusively from your Caterpillar dealer

2800 Series 2806A-E18TAG1A Diesel Engine ElectropaK

Bore mm 4.35 in Displacement 8.8 L 535 in³ Stroke mm 4.5 in Compression Ratio 10.1:1

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

Natural Gas Engine E 0836 E 302 Technical Data

Technical data TAD740GE

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

STANDBY 720 ekw 900 kva 50 Hz 1500 rpm 400 Volts

4000 Series TAG4 Diesel Engine ElectropaK rpm net standby power

Biogas Engine E 0836 LE 202 Technical Data for 60%-CH 4, 40%-CO 2

Standard equipment accessories on demand

See Note. 100% of rated load

1100 Series 4.4TW2GM Marine Auxiliary Engine kw (143.2 hp) gross prime 1800 rpm

Engine incl. cooling system and air filtration system Engine incl. cooling system, air filtration system, and frame. Standby Power

Transcription:

Gendrive Series 2000 Gx6 for Power Generation Standby Applications with air-to-air charge air cooling Dimensions and Masses Engine Dimensions (LxWxH) mm (in) Mass, dry kg (lbs) 2V 2086 x 522 x 470 (82 x 60 x 58) 2640 (5820) 6V 2436 x 570 x 420 (96 x 62 x 56) 300 (6834) 8V 26 x 572 x 420 (03 x 62 x 56) 3320 (739) All dimensions are approximate, for complete information refer to the installation drawing. Engine Model Bore/stroke mm (in) 35/56 (5.3/6.5) Cylinder configuration 90 V Displacement/cylinder l (cu in) 2.23 (36) Displacement, total l (cu in) 2V: 26.76 (633), 6V: 35.68 (277), 8V: 40.4 (2450) Fuel specification EN 590, Grade No.-D/2-D (ASTM D975-00) Application group Power definition Standardized Backup (3D) Emergency service, fuel stop power, Load factor: 85%, Operating hours: max. 500 h/year, IFN Overload: Fuel stop power (IFN) Prime Power for Emergency service, ICXN Load factor: 85%, Operating hours: max. 500 h/year, Stationary Emergency (3E) Overload: 0% capability (ICXN) Data Center Continuous (3F) Standby data center, Load factor: 00%, Operating hours: unrestricted, continuous power, ICXN Overload: 0% capability (ICXN) Power definition according to ISO 3046 (ratings also correspond to SAE J 995 and SAE J 349 standard conditions). Consult your MTU distributor/dealer for the rating that will apply to your specific application. Rated power is without fan drive. The power consumption of any fan drive has to be deducted during designing of a generator set. Power. Passion. Partnership.

Standardized Backup (3D) 24 3 36 TA-Luft (GB2098-204) 2V 2000 G76F 732 (982) x x x x 2V 2000 G86F 887 (89) x 6V 2000 G76F 979 (33) x x x x 6V 2000 G86F 00 (475) x 8V 2000 G76F 235 (656) x Engine Type Rated power kw (bhp) at 800 rpm (60Hz) Optimization 3 9 US EPA Stationary EMERG Tier 2 (40 CFR 60) (40 CFR 89) 8V 2000 G76S 37 (839) x x x 3 9 24 3 36 reference to emission level in price list 2 I Standby Applications

Prime Power for Stationary Emergency (3E) 24 3 36 TA-Luft (GB2098-204) 2V 2000 G6F 665 (892) x x x x x 2V 2000 G26F 709 (95) x x x x x 6V 2000 G6F 806 (08) x x x x x 6V 2000 G26F 890 (94) x x x x x 6V 2000 G36F 000 (34) x x x x x 8V 2000 G26F 02 (478) x x x x x 24 3 36 reference to emission level in price list 3 I Standby Applications

Data Center Continuous (3F) 24 3 36 TA-Luft (GB2098-204) 6V 2000 G26F 890 (94) x x x x x 8V 2000 G26F 02 (478) x x x x x 24 3 36 reference to emission level in price list 4 I Standby Applications

Standard Equipment Starting System Fuel System Lube Oil System Combustion Air System Cooling System Engine Mounting Engine Management electric starter (24 VDC/2-pole) Electronically controlled common-rail high-pressure injection system, dual engine mounted fuel filters Forced feed lubrication system with piston cooling, lube oil circulation pump, lube oil filter, lube oil heat exchanger 2 exhaust turbochargers, air-to-air intercooler integrated in radiator Coolant circulation pump and coolant thermostat for jacket water circuit, engine mounted fan drive, direct engine mounted radiator for jacket water and charge air cooling circuit with integrated expansion tank Set of engine mounting brackets for resilient mount Integrated electronic engine control and monitoring system ADEC, customer interface Smart Connect Subject to change. 323920 Edition 02/8 EPC 208-08. Optional Equipment Starting System Fuel System Combustion Air System Cooling System Engine Mounting Auxiliary Power Supply Reference conditions: Intake-air temperature: 25 C (77 F) Ambient air pressure: bar (4.5 psi) Altitude above sea level: 00 m (328 ft) Hydraulic, compressed air, redundant starting system: electric/electric; air/air; electric/air; electric/hydraulic; air/hydraulic Fuel pre-filter, special fuel pre-filter with water separator Heavy duty air filters Radiator for different ambient temperatures and duct requirements Resilient engine mounts (rubber elements), rigid engine mounting Battery charging alternator Subject to change without notice. Customization possible. Engines illustrated in this document may feature options not fitted as standard. For more information please contact your MTU dealer. MTU Friedrichshafen GmbH I MTU Asia Pte Ltd I MTU America Inc. Part of the Rolls-Royce Group www.mtu-online.com