Weighing Indicator TM701 Handrail scales

Similar documents
CS-250 Series. CHAIR SCALE SERVICE MANUAL (v1.06d)

Weighing Indicator. M503 Chair scales

T29 series. Wash Down S cale. Technical Manual. TotalcompR. Scales & Components

CITIZEN. series. Precision Balances

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

Compact Scales. Software Revision V1.25 & above

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

Before using the new scale, please take a little time to read the following safety instructions.

OPERATIONS MANUAL M-520. Please take the time to read these instructions before starting to use the scales. Page 1

Adam Equipment WBW & WBW-M SERIES. (P.N , Revision A2, November 2011)

seca 769 D GB F I E P

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Service manual Precision balance

1. Introduction Specifications Operation Guide Trouble shooting Note... 13

Full certification ISO 9001 ISO Model GB

OVERVIEW OF CONTROLS

Before using the new measuring rod, please take a little time to read the following safety instructions.

GRAVITY MEASUREMENT, INC.

WARRIOR SERIES USER MANUAL

Adam Equipment QT SERIES. ADAM EQUIPMENT CO. LTD. pn Rev. D1, July 2002

Adam Equipment CPW COMPACT SCALE

NPS Series. Pallet Jack Scale Operator s Guide (V1611)

User Instruction Manual Oxford Classic Digital Weigh Scale. To avoid injury, read user manual prior to use.

seca 954 D GB F I E Instruction manual and guarantee

ECONOMY COUNTING SCALE OPERATION & SERVICE MANUAL

Quick Guide. brite Advanced Retail scale

Virtual Measurements & Control. VC210 Operators Manual

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

Operating instructions Platform/floor scales

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

uline.com

GENERAL INFORMATION AVOID PLACING THE SCALE IN LOCATIONS THAT MAY AFFECT ACCURACY:

Defender 3000 Series Base Instruction Manual

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

SHS/SHSa SERIES. Adam Equipment. (P.N , Revision B November 2012) Software version S1.1/SA1.1

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

HM 200/201/210D Height Measurement USER MANUAL Please keep the instruction manual at hand all the time for future reference.

Adam Equipment LHS SERIES. (P.N , Revision A March 2012)

SCALIX MULTIPURPOSE SCALES SCALIX COMPACT SCALE FKS-600 FKS-6000 INSTRUCTION MANUAL

Operating manual Platform/floor scales

Charder. Medical scale. User instruction. Important information. This user instruction must be read before the medical scale is used.

SSP-Series Portable Balances Operation Manual

Catapult 1000 Series Instruction Manual

Electronic Crane Scale

MS-4200/4201/4202/4202L USER MANUAL

Model DS7060 Handrail Scale. User Manual

SC-Series. User Manual. American Weigh Scales. SC-501, SC-501A (500g x 0.01g) SC-2KG, SC-2KGA (2000g x 0.1g)

HS SERIES ELECTRONIC HANGING SCALE CONTENTS OPERATION MANUAL 1. OPERATING PRECAUTIONS 2. KEYBOARD LAYOUT AND DESCRIPTION 3. INSTRUCTIONS FOR USE

User s Guide. EZ-Bar Livestock Scale WEIGH BARS AND DIGITAL INDICATOR. WB-40 Weigh Bars TS-700 WB Digital Indicator. Guide version 1.

NCSA 20plus Service Manual

MARINER MODEL WPS12 WATERPROOF DIGITAL PORTION SCALE OWNER S MANUAL

The RCS-6V kit. Page of Contents. 1. This Book 1.1. Warning & safety What can I do with the RCS-kit? Tips 3

Valor 2000 Series Instruction Manual

HRS305. Hand Rail Scale

Model 3400KL / 3401KL / 3400KG / 3400KG-C Digital Wet Diaper / Lap Sponge / Organ Scale

LHS/LHSa SERIES. Adam Equipment. (P.N , Revision B November 2012) Software version L1.1/LA1.1

Operation and Service Manual WeighSouth WSI-600 Person Weigher

DIGITAL CRANE SCALE MODEL: OCS-SP USER MANUAL

Price Computing Scale D Series Operation Manual

This document is hosted by Old Will Knott Scales GBK and GFK Series

OCS-T High Resolution Digital Crane Scale

Weighing Scale IDS-802. User Manual

MULTI FUNCTION POWER PAK PLUS

SPC Series. Digital Scale. Operation Manual

Adam Equipment MIW-20 BABY SCALE. ADAM EQUIPMENT CO. LTD. p.n. 4295, Rev. B, March 2004

PTS SERIES With AE402 Indicator

DIGITAL CRANE SCALE MODEL: OCS-S9 USER MANUAL

American Weigh Scales LS-110. User Manual. LS-110 (110lb x 0.2lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 2.

INSTRUCTION MANUAL SPECIFICATIONS:

USER S MANUAL G SERIES USER S MANUAL. Ref.49-MG000EN08

Ohaus ES Series Bench Scale

OCS Series. High Resolution Digital Crane Scale. User Guide

ENGLISH SAFETY INSTRUCTIONS. Recommendations for safe operation. Operator safety. General warnings

SERVICE MANUAL Defender Bases Dry-use (B Series) Wet-use (V Series)

Adam Equipment CBK SERIES

Battery Charger. Series EASY Charger. User s manual

XK3190- A7. Weighing indicator USER MANUAL

Model 594KL Digital Chair Scale

BRAVER UPS. (Uninterruptible Power System) User s Manual

Model 8000XL OPERATOR MANUAL

b3c OPERATING MANUAL (GB) 9260(A) (A) 9360 Compacts scales 9260 (A) Ver 2014 EN September BC

Battery Charger Series EASY Charger

Operating Instructions Precision balance

PROFESSIONAL ELETTRONIC BARIATRIC BED SCALE MOD: PL-B (WU150)

PORT-A-WEIGH CRANE SCALES

Adam Equipment. GBK and GFK Series. (P.N , Revision D, August 2011)

Operation Instructions

Operation Instructions

PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL USA From outside US: +1 Tel: (561) Fax: (561)

Operator s Manual. Fairbanks FH Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 06/2017

EDGE. User Manual. EDGE-5K (5000g x 1g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 2.0

Operating instruction Compact balance

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

Benchmark HD Series Heavy Duty Bench Scale. Installation Manual

SAFETY GUIDE...4 PRECAUTION...4 PRODUCT CHARACTERISTICS...5 SPECIFICATION...5 MODEL...6 SIZE AND NET WEIGHT...7 OPERATION...8

Operation Instructions

Operating and Service Manual

Assembly instructions WAES

KILOTECH. KWD 500 Water tight. Portion/Weighing Scale

Price Computing Scale DS Series Operation Manual

Transcription:

Weighing Indicator TM701 Handrail scales REV: M1, September,01,2014 (v3.09-3.015)

- 2 -

CONTENTS 1. PRECAUTIONS..2 2. INTRODUCTION 3 3. SPECIFICATIONS...4 3.1Specifications...4 3.2 Load Cell Specification......5 4. INSTALLATION..6 5. DESCRIPTION...8 6. OPERATION..10 1. Power ON/OFF 10 2. Zero...10 3. Tare...10 4. Change unit...10 5. Hold function...11 6. Print and function..11 7. BMI function.11 8. Precision*10.. 11 7. PARAMETER.12 8. CALIBRATION..14 8.1 Calibration unit selection.. 14 8.2 Calibration.. 14 9. PRINT FORMAT....16 10. BATTERY OPERATION..17 11. MAINTENANCE 18 10.1 General..18 10.2 Error codes 19 10.3 Determine the Problem...19 10.4 Check the Load Cell 20 10.5 Check PCB Voltages...20 10.6 Trouble Shooting..21 12. DISPOSAL 23 13. WARRANTY 24-1 -

1. PRECAUTIONS WARNING DISCONNECT ALL POWER TO THIS UNIT BEFORE INSTALLING, CLEANING, OR SERVICING. FAILURE TO DO SO COULD RESULT IN BODILY HARM OR DAMAGE THE UNIT. CAUTION Permit only qualified persons to service the instrument Before connecting or disconnecting any components, remove the power. Failure to observe these precautions bodily harm or damage to or destruction of the equipment. Follow the instructions in the instructions for use. Keep the operating instructions and the declaration of conformity in a safe place. Ensure that the scale is standing firmly on a smooth, level surface. Do not drop the scale or subject it to violent shocks. When using the scale with a mains unit, ensure that the supply cable is routed in such a way as to exclude any type of tripping hazard. Use only the type of battery stated. Have scale serviced and re-calibrated on a regular basis. Have repairs carried out only by authorized persons. - 2 -

2. INTRODUCTION The TM701 series body scale, that amplifies signals from a load cell, converts it to digital data and displays it as a mass value. BMI with bar graph. Wheels at bottom, easy to move. Rubber mat on the surface of the platform. 25 mm LCD with white LED back light display 7 keypads are light touch switches Battery provide up to 22 hours of continues use (without backlight) Capacity up to 550lb - 3 -

3.1 Specifications TM701 Series Handrail Scales Technical Manual 3. SPECIFICATION Model TM701 Maximum Capacity 550lb Readability 0.1lb Resolution 1/5,500 Tare range -549.9lb Minimum Capacity 2lb Linearity ± 0.2lb Common Specifications Interface RS-232 Output Optional Stabilisation Time 2 Seconds typical Operating Temperature 0 C - 40 C / 32 F - 104 F Power supply (external) 12V/500mA AC power adapter or 2000mAh Ni-MH batteries (optional, size AA) Calibration Automatic External Calibration as per Directive 90/384/EEC Class III medical approval Medical product as per Directive 93/42/EEC Class I ADC Σ-Δ Display 25 mm high 6 digits LCD with auto backlight and loading bar graph Housing Aluminium pan and pole, ABS plastic indicator Pan Size 355x360mm Height measuring range From approx. 90cm to 200 cm (2'11'' to 6'8'') - 4 -

3.2 Load Cell Specifications Model No L6E Rated Capacity (kg) 2.5/3/5/6/8/10/15/20/30/35/40/50 Sensitivity 2.0±0.2 mv/v Excitation Voltage 5~12V Material Aluminum Cable 0.3~3m Φ 4mm Input Resistance 409Ω ±6Ω/1065Ω ±15Ω Out put Resistance 350Ω ±3Ω/1000Ω ±10Ω Temperature Range -35 C ~ +65 C Safe overload 150%F.S Ultimate overload 300%F.S Error ±0.0233%F.S Creep (20min) ±0.020%F.S Zero Balance 0±5%mV/V Max. Platform Size 250x350mm - 5 -

4. INSTALLATION Unpacking Carefully take the balance out of its package, make it sure its not damaged and all accessories are included. Remove the weighing scale from the carton. Remove the protective covering. Store the packaging and to use if you need to transport the scale later. Inspect the scale and terminal for damage. Make sure all components are included Accessories, 1. Balance 2. Adaptor 3. Product manual Level Adjusting Place the scale on a table. Check the water mark. If, bubble is not centre adjust the leveling feet until reach centre. Check the level when you change the location. Charging Battery To charge the battery insert the adaptor pin to jack, jack is locating rear side of the scale. Adaptor simply plug into the mains power. The scale no needs to be turned on. The battery should be charged for 12 hours for full capacity. In the display there is an indicator show the status of battery charging. When the scale is plugged into the mains power the internal battery will be recharged. If the indicator off, the battery has a full charge. If it is on, the battery is nearly discharged and if yellow, the battery is being charged. Do not use any other type of power adaptor than the one supplied with the scale. Verify that the AC power socket outlet is properly protected. Note: Please charge the battery before using the scale for the first time - 6 -

Installation USB Connecter (selectable) RS-232 Connecter (selectable) Calibration switch Adaptor Jack Place the scale on a table. Connect the adaptor pin in to the scale adaptor jack. Adaptor jack is locating, rear side of the scale. Adaptor connects into your AC power socket. Pluggable equipment must be installed near an easily accessible socket outlet with a protective ground/ earth contact. Display will show the version number and will start self checking. After self checking, display will be come to normal weighing mode. Warm-up time of 15 minutes stabilizes the measured values after switching on. Calibrate with exact calibration weights, minimum 1/3 of the scale capacity want to use for calibration. For calibration see details in parameter. Then you can start your operation - 7 -

5. DESCRIPTION Key Board Turns the scale power On / Off Set to hold mode Set to BMI mode Set pre-tare Change unit: kg / lb Sets display to Zero Subtracts weight of container - 8 -

Display DISPLAY STABLE ZERO TARE NET GROSS Cm/inch Lb/kg FUNCTION Indicator for Display stability Indicator for Zero display Indicator for Tare display Indicator for weighing capacity graph Indicator for Net weight Indicator for Gross weight Indicator for measuring units Indicator for weight units Indicator for Charging status of battery Voltage has dropped Low Voltage Fully Charged - 9 -

6. OPERATION Initial Start-up Warm-up time of 15 minutes stabilizes the measured values after switching on. 6.1 Power ON/OFF Switch on the scale by pressing. The display is switched on and the self test is started. If you want to switch off press the key again. 6.2 Zero Environmental conditions can lead to the balance exactly zero in spite of the pan not taking any strain. However, you can set the display of your balance to zero any time by pressing ensure that the weighing starts at zero. key and therefore 6.3 Tare You can tare the weight of any container by pressing key so that with subsequent weighing the net weight of the object being weighed is always displayed. Load weight on the pan. Press key. Zero is displayed, and tare is subtracted. Remove weight from the platform. Tared weight is displayed. It can set only one tare value. It can display with a minus value. Press key. Zero is displayed, tare weight is cleared. 6.4 Change unit In weighing condition, you can press to change the unit: kg / lb. If you want to change the unit of height measurement, please set it in parameter F5 stu. (page 13) - 10 -

6.5 Hold function Press before load at the pan, so HOLD is active now. "Hold " and "--- --" appeared at the display. After put load at the pan no indication until a stable non-zero weights is detected. During this period "----" is indicated. (no indication of unstable value).you will hear an acoustic beep, when stable weight (>20d)is detected. It will show calculated HOLD-value with small "HOLD" in display. After unloading the pan the value is indicated for 10 Seconds. After that normal weight displaying is resumed., while the HOLD-function is active, will cancel the HOLD- Pressing function. In hold function, you can t do ZERO and TARE operation. 6.6 Print function Press key to print the weight value, you can disable this function (see the parameter on Section 7) 6.7 BMI function Press key on the weighing mode, display will show the last height xxxxxx, use key to change digit, and press key to increase the value, press key confirm it, display will enter into the BMI mode, BMI indicator will be shown, people stand on the platform display will show the BMI value and the BMI bar, Press key will turn back to weighing mode. 6.8 Precision*10 If you want to see more accurate weight value, press and hold for 2 seconds, display will show one more decimal place, the last digit will twink for 5 seconds, then it will go back to normal weighing value automatically. - 11 -

7. PARAMETERS Enter the Menu Press during self checking(9--0), display will show Choose the Menu F1 off Press, it can choose menu block or options one by one. Enter the Selected Menu Press, it can confirm which will be shown displayed. Enter in to TECH Note: Before enter the tech menu, press calibration switch, which is locating below the scale When display showed Pi n, press and keys to enter the function Escape from the Menu Press key, it can escape from the menu to weighing mode. Parameter Block Menu Sub Menu F1 off 0/ 3/ 5/ 15/ 30 off Description To set the auto power-off time. Unit is minutes. If you select 0,it will not auto power-off. Disable print function. F 2 swt prt Enable print function. - 12 -

F3 prt Seire P prt P cont P auto ask P cnt2 Also send data continuous By pressing Print key, weighing value will be added to the memory and print the print out Send data continuous Automatic accumulation. Individual weighing values are automatically added ASK mode Command R: read data Command T: Tare Command Z: Zero Send data another continuous mode. P stab Send data when the weighing values is stable F4 bk Bl on Set the backlight always on. Bl off Set the backlight always off. Bl au Set the backlight automatically on. F5 stu cm Select unit cm F6 unit inch Kg on/ off Lb on/ off Select unit inch Enable/ disable unit kg Enable/ disable unit lb tch pin Enter the password P 1 spd Set A/D convert speed(7.5/15/30/60) P 2 Cal desc inc cap cal To set decimal points. Options: 0,0.0, 0.00, 0.000, 0.0000 To set increment Options: 1, 2, 5, 10, 20, 50 (kg) Options: 2, 5, 10, 20, 50, 100 (lb) Set capacity Enter into calibration P 3 pro tri Deprecated function count To show the scale internal count reset Reset the scale setgra Set the gravity value - 13 -

8. CALIBRATION 8.1 Calibration unit selection Turn on the scale. And during its self checking. Press key, display will show cal uni Press key,display will show the current calibration unit Press key to choose the required calibration unit Press confirm. And during its self checking. 8.2 Calibration Calibration Settings in the Parameter; Turn on the scale Press key during self checking, display will show Press key until to display Press key to confirm display will show Press and keys, display will show Press key to show display Press key to enter calibration, Display will show Press key until display show Press key into calibration, display will show When scale get stable, Press key, Display will be show last calibration weight, F1 off tch pin P1 spd P2 cal desc Cal unload 00100.0 If it s required, change calibration weight value by using and keys Press key to confirm the value Load - 14 -

Display will be show Place the test weight on the platform. After stable, press key confirm Display will be show Then will start self-test, unload test weight during the self test. Scale will come to normal display pass Note: the unit (kg / lb) is the same as the last displayed one. That is: before you restart the scale to do calibration, if you see the unit is kg, then in calibration, the unit is kg; if you want to change to lb, you need to press U key to change the unit before you restart it. Note: During the calibration end, when display shows pass and start self test, test weights should be want to unload before showing normal display for to avoid Err 19. Normal Calibration Turn on the scale During the self-test, press key unload Keep empty platform When scale get stable, Press key, Display will be show last calibration weight, 00100.0 If it s required, change calibration weight value by using and keys Press key to confirm the value Display will be show Place the test weight on the platform. After stable, press key confirm Display will be show Then will start self-test, unload test weight during the self test. Scale will come to normal display Load pass - 15 -

9. PRINT FORMAT PRT Print format 0 2012/08/09 11:00 60.0 kg 1 2012/08/09 11:00 60.0 kg 170.0cm 20.7BMI 2 60.0 kg 3 60.0 kg 170.0cm 20.7BMI Note: TPUP can t print out the date and time. - 16 -

10. BATTERY OPERATION The Medical Scales can be operated from the battery if desired. The battery life is 16 hours (backlight) and 22 hours (without backlight). When the battery needs charging a symbol on the weight display will turn on. The battery should be charged when the symbol is on. The scale will still operate for about several minutes after which it will automatically switch off to protect the battery. To charge the battery simply plug into the mains power. The scale does not need to be turned on. The battery should be charged for 12 hours for full capacity. Just under the quantity display is an LED to indicate the status of battery charging. When the scale is plugged into the mains power the internal battery will be charged. If the LED is green the battery has a full charge. If it is Red the battery is nearly discharged and yellow indicates the battery is being charged. As the battery is used it may fail to hold a full charge. If the battery life becomes unacceptable then contact your distributor. Note: useless battery should be recycled, not throw away as household refuse. - 17 -

11. MAINTENENCE WARNING DISCONNECT ALL POWER TO THIS UNIT BEFORE INSTALLING, CLEANING, OR SERVICING. FAILURE TO DO SO COULD RESULT IN BODILY HARM OR DAMAGE THE UNIT. CAUTION Permit only qualified persons to service the instrument Before connecting or disconnecting any components, remove the power. Failure to observe these precautions bodily harm or damage to or destruction of the equipment. 10.1. General If the scale does not operate properly, find out the problem as possible. Determine whether the problem is constant or alternate. Be aware that problems can be caused by mechanical or electrical influences. Check the following. Water Corrosive materials Vibrations or temperature or wind Physical damage Check the scale cables for damage, and check all connections and connecters for any loose contact or incorrect connection - 18 -

Cleaning Disconnect the power before cleaning. Use a cloth with mild suds and light cleaning agents. Make sure that fluid not able to get into the device. Use a clean and soft cloth for rub off. 10.2. Error Codes Error Code Description POSSIBLE CAUSES Err 4 Exceed manual zero range Goods on the platform Overload, when (pressing ) zeroing the scale. Improper calibration Load cell problem PCB problem Err 6 A/D Count out of the range Platform not installed Load cell problem PCB problem Err 19 Exceed Auto Zero range Goods on the platform When switch on the scale Improper calibration Load cell problem PCB problem 10.3. Determine the Problem Determine whether the problem is in the PCB or the Load Cell Remove power from the system, and disconnect the load cell connection from the PCB Connect the PCB to a load cell simulator Reapply power and test the PCB If problem goes away, its source is probably in the Load cell. Check the wiring, connecter, load cell and mechanical components of the load cell. If problem persists, its source is probably in the PCB. Check the PCB voltages, connecters, cables and function programs - 19 -

10.4. Check the Load cell Remove power from the system, and disconnect the PCB from the Load cell Check the moisture, or foreign material inside. Make sure all leads are connected and correctly. Check load cell for proper input and output resistances Load Cell Connections Signal + Green Supply + Red Signal - Black Supply - Shield White Measuring Points Resistance Red (+ Exc) to White ( Exc) 420 ±20Ω Green (+Sig) to Black ( Sig) 350Ω ±5Ω 10.5. Check PCB Voltages If the problem is in the PCB, use a multimeter to check the following voltages 10.5.1 AC Power Check the AC power socket out put voltage. Voltage must be a -20% and +10% of the normal AC voltage. 10.5.2 Adaptor Voltage Check the adaptor output cable connecter voltage Voltage must be minimum 9VDC and maximum 15VDC - 20 -

10.5.3 PCB Input Voltage Check the PCB input power connecter voltage Voltage must be minimum 9VDC in to the pin AD+ 10.5.4 Check Battery Voltage and Charging Voltage 1. Check the Battery Voltage, Voltage must be minimum 6VDC. If below the 6VDC connect the adaptor for charging The battery voltage below the 5.5VDC, replace the battery and install new 6V/3.4Ah battery. 2. Check the Battery Charging Voltage; Remove the battery connection terminals (Red and Black) from the battery. Connect the power and turn on the scale Voltage into the terminal minimum 6.5VDC 10.6 Trouble Shooting Problems Possible cause Common Solutions Display is blank. No self test Blank display after self test Mains power is turned off. Power supply faulty or not plugged. Internal battery is not charged. On/Off switch problem Pan not installed. Unstable weight, load cell damaged Check power is getting inside the scale and on/off switch is working. Verify the voltages, which is on the power labels. Check the pans are installed correctly. Try to turning on again. OL or ------- ------- or NULL displayed Maximum capacity exceeded. Load cell or mechanics damaged. Power supply faulty Weight is on the platform is below permissible limit. Pan not installed correctly. Power supply faulty. Load cell or mechanism faulty Check the platform is installed correctly. Try to turn on the scale again. Do the calibration again Check the platform is installed correctly. Try to turn on the scale again. Do the calibration again - 21 -

Display is unstable Weight value incorrect Can not use full capacity Platform Corner Weight different Battery not charging Goods touching somewhere. Air variation or any vibrations. Temperature changed. Load cell or connections faulty. Power supply faulty Calibration error. Platform of load cell touching somewhere. Wrong weighing unit Over load protection stoppers or transport locks are not removed. Parameters are set incorrectly. AD problem. Load cell or mechanism damaged Over load protection stoppers or transport locks are not removed. Load cell or mechanism damaged Mains voltage problem Charging circuit problem Battery Problem Check the scale is in acceptable location. Check the connecters and load cell. Check the power supply and battery Use accurate weight for to do the calibration Check the pan and load cell is installed proper and touching. Check the parameter settings. Check the load cell and connecters Check the stoppers and locks under the platform. Check the weighing unit and parameter settings. Check the load cell. Check the stoppers and locks under the platform. Use accurate weight for to do the calibration Check the load cell. Check the mains and adaptor. Check the battery. Check the charging circuit - 22 -

Disposing of the device TM701 Series Handrail Scales Technical Manual 12. DISPOSAL Do not dispose of the device in domestic waste. The device must be disposed of properly as electronic waste. Follow the national regulations which apply in your case. For further information, contact our service department at: service@taiwanscale.com Batteries Do not throw used batteries away in domestic waste. Dispose of batteries at collection points in the vicinity. When buying new batteries, select those low in harmful substances and containing no mercury (Hg), cadmium (Cd) or lead (Pb). - 23 -

13. WARRANTY A two-year warranty from date of delivery applies to defects attributable to poor materials or workmanship. All moveable parts batteries, cables, mains units, rechargeable batteries etc. are excluded. Defects which come under warranty will be made good for the customer at no charge on production of the receipt. No further claims can be entertained. The costs of transport in both directions will be borne by the customer should the equipment be located anywhere other than the customer s premises. In the event of transport damage, claims under warranty can be honoured only if the complete original packaging was used for any transport and the scale secured and attached in that packaging just as it was when originally packed. All the packaging should therefore be retained. A claim under warranty will not be honoured if the equipment is opened by persons not expressly authoried by T-scale to do so. We would ask our customers abroad to contact their local sales agent in the event of a warranty matter. - 24 -

The company was founded in Taiwan in 1967 as Taiwan Scale Mfg Co., Ltd in order to produce Mechanical Weighing Instrument. Today, this privately owned company is recognized worldwide as a leading Electronic Weighing Scale Manufacturer. The core business of TSCALE is the development, manufacture, worldwide sales/marketing and service of electronic weighing instruments. The TSCALE products Medical Scale Counting Scale Tabletop Scale Retail Scale Precision Scale Pallet Scale Weighing Indicator Crane Scale Floor and Pallet Scale Accessory Software TSCALE has its manufacturing unit in Kunshan, China, ISO 9001 certified company, ODM partner, more than 20 products have OIML certifications from Holland s NMI and Denmark s Delta. TScale Electronics Mfg. (Kunshan) Co., Ltd. 268, Zhujiawan Road, Kunshan, Jiangsu, China Tel : +86 512 57067900 / 57669080 Fax: +86 512 5769508 / 57669100 Taiwan Scale Mfg. Co., Ltd 282, Sec.3, Hoping W.Rd., Taipei, Taiwan Tel : +886 2 23068203 Fax: +886 2 23044354-25 -