TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com

Similar documents
Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys D Green. Catalogue 2017 AC/DC compatible coil contactors. schneider-electric.com

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors

AF40... AF96 3-pole contactors Technical data

Modular contactors and relays

Industrial Contactors CTX 3 3P 185A - 800A

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

3 - Protection components Motor circuit-breakers

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

C -5 to +55 (0.8 to 1.1Uc) Permissible o

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Low Voltage. EasyPact TVS. Motor starters from 6A to 630A. Catalog 2015

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

RUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

AE 9... AE 40 Contactors NE... Contactor Relays

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

XACA871 pendant control station XAC-A - 8 pushbuttons

K50H004UP cam changeover switch - 4-pole A - screw mounting

XACA871 pendant control station XAC-A - 8 pushbuttons

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K50F003UP cam changeover switch - 3-pole A - screw mounting

K63F003UP cam changeover switch - 3-pole A - screw mounting

Short form catalogue. Motor protection & control

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

Essential equipment for all your requirements

XMLB300D2C11 pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O

Square D General Purpose Relays

Description. Positive safety relays

ASL09..S 3-pole Contactors - Spring Terminals

RPF2AF7 power relay plug-in - Zelio RPF - 2 NO V AC - 30 A

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

Switches Unlimited Phone: * Fax:

XACA871 pendant control station XAC-A - 8 pushbuttons

XMLB020A2S13 pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O

Meta Solution. Contactors and Overload relays

LR9 F OVERLOAD RELAYS

TAE pole Contactors

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Auxiliary contact blocks - with spring terminals Accessories

DX³ RCCBs - ID 4P up to 100 A

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Micro Contactor MA Series

Page 2-4 Page 2-8. Page Page 2-13

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Low Voltage. TeSys B contactors. Variable composition contactors, new design. Catalogue

XMLA002A2C11 pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS

Manual Motor Starters. Meta-MEC

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

TX³ RCCBs 2P up to 100 A

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16

Meta Solution. Contactors and Overload relays

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

TeSys Enclosed Starters. Let TeSys ensure safety in your simple motor applications

Thermal Overload Relays

B Mini Contactor V Hz

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

About us. Switchgear Factory, Mumbai

Limit switches 3. Page 92. Page 92

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

Controls. CONTACTORS CWB Line (up to 40A)

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

For Info: Phone: Fax:

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Mini contactors B6, BC6 with 3 pole

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

XMLA160D2S11 pressure switch XMLA 160 bar - fixed scale 1 threshold - 1 C/O

AF series contactors (9 2650)

CI-TI Contactors and motor starters Types CI 61 - CI 98

Easy Choice for Energy Efficiency

CI-TI Contactors and Motor Starters Type CI 6-50

Pendant control stations 6

Star Series Motor protection & control


Screw limit switches XRBA and XR2. Catalogue

Transcription:

TeSys D, K Catalogue 2017 'S335' series contactors for electrodomestic applications schneider-electric.com

Presentation TeSys D, TeSys K TeSys D, TeSys K: S335 series Best-in-class contactors for electrodomestic applications Schneider Electric reliable control solutions for professionals 2

Presentation TeSys D, TeSys K Used in professional machines as electrical ovens, dishwashers, fridges, washing achines, driers, heating machines,high pressure cleaners, etc. TeSys D and TeSys K S335 series contactors are designed for machine power switching and controlling applications, while complying with the electrodomestic EN60335 standards. 3

Presentation TeSys D, TeSys K TeSys D, TeSys K: S335 series contactors, Schneider Electric introduces their best-in-class contactor ranges for easing electro-domestic machine certification. Made with dedicated plastic materials, TeSys D and TeSys K S335 series contactors are fully compliant with EN 60335-1 standard. They have been successfully submitted to: p Glow Wire Test at 850 C, p Ball Pressure Test at 125 C on all parts, p IRC test validation at 250 V, to resist to harshest electro-domestic environments. Naturally, the standard ranges advantages are fully preserved: p TeSys D longest electrical lifetime on the market, p TeSys K high compactness. 4

Contents TeSys D, TeSys K Presentation Page TeSys D S335 series 6 TeSys K S335 series 7 References TeSys D S335 series 8 TeSys K S335 series 10 Technical Data for Designers 11 TeSys D S335 series Characteristics 12 Dimensions and schemes 15 TeSys K S335 series Characteristics 16 Dimensions and schemes 20 5

Presentation - TeSys D TeSys D S335 series - Contactors for Electrodomestic applications PB108318.eps NEW TeSys D - S335 series Made of dedicated material, fully EN 60335 compliant, with unchanged commercial reference. Applications: p AC-3, up to 38 Amps p AC-1, up to 40 Amps p control circuits, up to 10 Amps. Reliable and long-lasting, TeSys D is the ultimate choice for demanding or wide power range applications Range of 20 contactors for motors (AC-3), resistive loads (AC-1), control circuits: 3P, 4P contactors: p AC-3 ratings / 3 poles: 9, 12, 18, 25, 32, 38 A p AC-1 ratings / 4 poles: 20, 25, 32, 40 A p 1 NO + 1 NC embedded auxiliary contact on all ratings Contactors for control circuits: p 5 NO or 3 NO + 2 NC p 10 A Common features: p connection by screw clamps terminal p 24 or 230 V AC coils See TeSys D S335 contactor selection tables for available combinations of features. 6

Presentation - TeSys K TeSys K S335 series - Contactors for Electrodomestic applications LP4K PB111997.eps NEW TeSys K - S335 series New range of EN 60335 compliant mini contactors: - width: 45 mm - height: 58 mm - depth: 57 mm - weight: 0.235 kg. Applications: p AC-3, up to 16 Amps p AC-1, up to 20 Amps p control circuits, up to 10 Amps. Simple, robust, and compact, TeSys K is optimized for common applications Range of 26 contactors for motors (AC-3), resistive loads (AC-1), control circuits: 3P, 4P contactors: p AC-3 ratings / 3 poles: 6, 9, 12, 16 A p AC-1 rating / 4 poles: 20 A p 1 NO or 1 NC embedded auxiliary contact Contactors for control circuits: p 4 NO or 2 NO + 2 NC or 3 NO + 1 NC p 10 A Common features: p connection by screw clamps terminal p 24 or 230 V AC coils See TeSys K S335 contactor selection tables for available combinations of features. 7

References - TeSys D TeSys D S335 series - Contactors for Electrodomestic applications 3-pole contactors for Motor control Standard power ratings of 3-phase motors 50-60 Hz in category AC-3 (q y 60 C) 220 V 230 V 380 V 415 V 415 V 440 V 500 V 660 V 690 V 1000 V Rated Instantaneous operational auxiliary current contacts in AC-3 440 V up to Commercial reference Replace dots by coil voltage code (see chart below) coil with surge suppressor (1) Weight PB108300.eps kw kw kw kw kw kw kw A kg 2.2 4 4 4 5.5 5.5 9 1 1 LC1D09ppS335 0.320 3 5.5 5.5 5.5 7.5 7.5 12 1 1 LC1D12ppS335 0.325 4 7.5 9 9 10 10 18 1 1 LC1D18ppS335 0.330 5.5 11 11 11 15 15 25 1 1 LC1D25ppS335 0.370 7.5 15 15 15 18.5 18.5 32 1 1 LC1D32ppS335 0.375 9 18.5 18.5 18.5 18.5 18.5 38 1 1 LC1D38ppS335 0.380 LC1D09 4-pole contactors Non inductive loads maximum current (q y 60 C) utilisation category AC-1 Number of poles Instantaneous auxiliary contacts Commercial reference Replace dots by coil voltage code (see chart below) coil with surge suppressor (1) Weight PB108318.eps A kg Contactors for Resistive load control 20 4 1 1 LC1DT20ppS335 0.365 25 4 1 1 LC1DT25ppS335 0.365 32 4 1 1 LC1DT32ppS335 0.425 40 4 1 1 LC1DT40ppS335 0.425 (1) A suppressor diode (Transil TM) in parallel with the coil prevents upstream sensitive components from damage by transient high voltage during the coil switching. LC1DT20 Coil voltage codes AC Volts 24 42 48 110 220 230 240 380 400 U 0.8 1.1 Uc at 50 Hz U 0.85 1.1 Uc at 60 Hz B7 - - - - P7 - - - Characteristics: pages 12 to 14 8 Dimensions, schemes: page 15

References - TeSys D TeSys D S335 series - Contactors for Electrodomestic applications PB114194.eps Contactors for control circuit Rated max operating current (Ie) Composition Commercial reference Replace dots by coil voltage code (see chart below) coil with surge suppressor A 5-pole contactors for control circuits 10 3 2 CAD32ppS335 5 CAD50ppS335 CAD32 Coil voltage codes AC Volts 24 42 48 110 220 230 240 380 400 U 0.8 1.1 Uc at 50 Hz U 0.85 1.1 Uc at 60 Hz B7 - - - - P7 - - - Characteristics: pages 12 to 14 Dimensions, schemes: page 15 9

References - TeSys K TeSys K S335 series - Contactors for Electrodomestic applications PB115725.eps 3-pole contactors for Motor control - connection by lugs Standard power ratings of 3-phase motors 50-60 Hz in category AC-3 220 V 230 V 380 V 415 V 440/500 V 660/690 V Rated operational current in AC-3 440 V up to Instantaneous auxiliary contacts Commercial reference Replace dots by coil voltage code (see chart below) Weight LC1K12 kw kw kw A kg 1.5 2.2 3 6 1 LC1K0610ppS335 0.235 1 LC1K0601ppS335 0.235 2.2 4 4 9 1 LC1K0910ppS335 0.235 1 LC1K0901ppS335 0.235 3 5.5 5.5 (y 440) 12 1 LC1K1210ppS335 0.235 4 (u 480) 1 LC1K1201ppS335 0.235 4 7.5 4 (y 440) 16 1 LC1K1610ppS335 0.235 5.5 (440) 1 LC1K1601ppS335 0.235 PB115726.eps 4-pole contactors - connection by lugs Non inductive loads Category AC-1 Maximum current at (q y 50 C) Number of poles Instantaneous auxiliary contacts Commercial reference Replace dots by coil voltage code (see chart below) LC1KT A 20 4 LC1KT20ppS335 0.235 2 2 LC1K098ppS335 0.235 PB115727.eps 4-pole contactors for Control circuit - connection by lugs Control circuit consumption Auxiliary contacts Commercial reference Replace dots by coil voltage code (see chart below) CAK Ith = 10 A 4 CAK40ppS335 0.235 3 1 CAK31ppS335 0.235 2 2 CAK22ppS335 0.235 Coil voltage codes AC Volts 24 42 48 110 220 230 240 380 400 U 0.8 1.15 Uc B7 - - - - P7 - - - Characteristics: pages 16 to 19 10 Dimensions, schemes: page 20

TeSys D, K Technical Data for Designers Contents TeSys D S335 series: Characteristics... 12 to 14 Dimensions and schemes...15 TeSys K S335 series: Characteristics...16 to 19 Dimensions and schemes... 20 11

Characteristics - TeSys D TeSys D S335 series - Contactors for Electrodomestic applications Environment Contactor type LC1 Rated insulation voltage (Ui) Conforming to IEC 60947-4-1, overvoltage category III, degree of pollution: 3 Rated impulse withstand voltage (Uimp) Conforming to IEC 60947 kv 6 D09 D18 DT20 and DT25 V 690 D25 D38 DT32 and DT40 Conforming to standards IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 60335-1 Product certifications IEC, CCC, EAC, UA, TR Degree of protection (front face) Conforming to IEC 60529 Power circuit connections Protection against direct finger contact IP20 Coil connection Protection against direct finger contact IP20 Protective treatment Conforming to IEC 60068-2-30 "TH" Ambient air temperature around the device Storage C -60 +80 Operation C -5... +60 C (or -40... +70 C at UC only) Maximum operating altitude Without derating m 3000 Operating positions (1) Without derating in the following positions (other positions: please contact us). DF510743.eps AC DF537812.eps 180 90 90 Flame resistance Conforming to UL 94 V0 Conforming to IEC 60695-2-1 C 850 Shock resistance (2) 1/2 sine wave = 11 ms Vibration resistance (2) 5 300 Hz Contactor open 10 gn 8 gn Contactor closed 15 gn 15 gn Contactor open 2 gn Contactor closed 4 gn 4 gn (1) When mounting on a vertical rail, use a stop. (2) Without modifying the contact states, in the most unfavourable direction (coil energised at Ue). References: pages 8 and 9 12 Dimensions, schemes: page 15

Characteristics - TeSys D TeSys D S335 series - Contactors for Electrodomestic applications Pole characteristics Contactor type Rated operational current (Ie) (Ue y 440 V) Rated operational voltage (Ue) Frequency limits Conventional thermal current (Ith) Rated making capacity (440 V) Rated breaking capacity (440 V) Permissible short time rating No current flowing for preceding 15 minutes with q y 40 C LC1D09 (3P) LC1DT20 (4P) LC1D12 (3P) LC1DT25 (4P) LC1D18 (3P) LC1DT32 (4P) LC1D25 (3P) LC1DT40 (4P) LC1D32 (3P) In AC-3, q y 60 C A 9 12 18 25 32 38 In AC-1, q y 60 C A 25 20 25 25 32 32 40 40 50 50 Up to V 690 690 690 690 690 690 Of the operational current LC1D38 (3P) Hz 25 400 25 400 25 400 25 400 25 400 25 400 q y 60 C A 25 20 25 25 32 32 40 40 50 50 Conforming to IEC 60947 Conforming to IEC 60947 A 250 250 300 450 550 550 A 250 250 300 450 550 550 For 1 s A 210 210 240 380 430 430 For 10 s A 105 105 145 240 260 310 For 1 min A 61 61 84 120 138 150 For 10 min A 30 30 40 50 60 60 Fuse protection Without type 1 A 25 40 50 63 63 63 against short-circuits thermal (U y 690 V) overload relay, gg fuse type 2 A 20 25 35 40 63 63 Average impedance At Ith and 50 Hz mw 2.5 2.5 2.5 2 2 2 per pole Power dissipation AC-3 W 0.20 0.36 0.8 1.25 2 3 per pole for the above operational currents AC-1 W 1.56 1.56 2.5 3.2 5 5 Control circuit characteristics, a.c. supply Rated control circuit voltage 50/60 Hz V 12 690 (Uc) Control voltage limits 50 or 60 Hz Operation coils Drop-out 50/60 Hz Operation 0.8 1.1 Uc on 50 Hz and 0.85 1.1 Uc on 60 Hz at 60 C coils Drop-out 0.3 0.6 Uc at 60 C Average consumption at 20 C and at Uc Heat dissipation a 50 Hz Inrush 50 Hz coil VA Cos j 0.75 50/60 Hz coil VA 70 Sealed 50 Hz coil VA Cos j 0.3 50/60 Hz coil VA 7 a 60 Hz Inrush 60 Hz coil VA Cos j 0.75 50/60 Hz coil VA 70 Sealed 60 Hz coil VA Cos j 0.3 50/60 Hz coil VA 7.5 50/60 Hz W 2 3 Operating time Closing "C" ms 12 22 Opening "O" ms 4 19 Mechanical durability 50 or 60 Hz coil in millions of operating 50/60 Hz coil on cycles 50 Hz 15 Maximum operating rate at ambient temperature y 60 C In operating cycles per hour 3600 References: pages 8 and 9 Dimensions, schemes: page 15 13

Characteristics - TeSys D TeSys D S335 series - Contactors for Electrodomestic applications Power circuit connections Screw clamp terminal connections Contactor type LC1 D09 D18 and D12 DT20 (3P) and DT25 D25 (3P) D32 D38 D18 and D25 (4P) DT32 and DT40 Tightening Screw clamp terminals Connector 2 inputs Flexible cable 1 conductor mm 2 1 4 1.5 6 2.5 10 2.5 10 without cable end 2 conductors mm 2 1 4 1.5 6 2.5 10 2.5 10 Flexible cable 1 conductor mm 2 1 4 1 6 1 10 2.5 10 with cable end 2 conductors mm 2 1 2.5 1 4 1.5 6 2.5 10 Solid cable 1 conductor mm 2 1 4 1.5 6 1.5 10 2.5 16 without cable end 2 conductors mm 2 1 4 1.5 6 2.5 10 2.5 16 Screwdriver Philips N 2 N 2 N 2 N 2 Flat screwdriver Ø Ø6 Ø6 Ø6 Ø6 Hexagonal key Tightening torque N.m 1.7 1.7 2.5 1.8 Control circuit connections Connection by cable (tightening via screw clamps) Flexible cable 1 conductor mm 2 1 4 1 4 1 4 1 4 1 4 without cable end 2 conductors mm 2 1 4 1 4 1 4 1 4 1 4 Flexible cable 1 conductor mm 2 1 4 1 4 1 4 1 4 1 4 with cable end 2 conductors mm 2 1 2.5 1 2.5 1 2.5 1 2.5 1 2.5 Solid cable 1 conductor mm 2 1 4 1 4 1 4 1 4 1 4 without cable end 2 conductors mm 2 1 4 1 4 1 4 1 4 1 4 Screwdriver Philips N 2 N 2 N 2 N 2 N 2 Flat screwdriver Ø Ø6 Ø6 Ø6 Ø6 Ø6 Tightening torque N.m 1.7 1.7 1.7 1.7 1.7 Characteristics of auxiliary contacts incorporated in the contactor Mechanically linked Conforming to IEC 60947-5-1 Each TeSys D NO/NC embedded auxilliary contacts are certified mechanicaly linked. contacts Mirror contact Conforming to IEC 60947-4-1 All TeSys D NC auxilliary contacts are miror certified and can be connected to a safety module. Rated operational voltage Up to V 690 (Ue) Rated insulation voltage (Ui) Conforming to IEC 60947-1 V 690 Conventional thermal current (Ith) For ambient temperature y 60 C A 10 References: pages 8 and 9 14 Dimensions, schemes: page 15

Dimensions, schemes - TeSys D TeSys D S335 series - Contactors for Electrodomestic applications LC1D09 D18 (3-pole) LC1D25 D38 (3-pole) 77 85 db425761.eps db425762.eps 86 45 92 45 LC1DT20, DT25 (4-pole) LC1DT32, DT40 (4-pole) 85 91 db425763.eps db425764.eps 92 45 99 45 Contactors 3-pole contactors LC1D09 to D38 4-pole contactors LC1DT20 to DT40 127266.eps A2 A1 2/T1 1/L1 4/T2 3/L2 6/T3 5/L3 14 13/NO 22 21/NC 127267.eps References: pages 8 and 9 Characteristics: page 12 to 14 15

90 Characteristics - TeSys K TeSys K S335 series - Contactors for Electrodomestic applications Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp and LPp K06 to K12 UL, CSA Operating positions Vertical axis Horizontal axis DF511522.eps 90 DF511523.eps 180 DF564970.eps 90 90 Without derating Without derating Contactor pull-in voltage: 0.85 Uc Connection Min. Max. Max. to IEC 60947 Screw clamp Solid conductor mm 2 1 x 1.5 2 x 4 1 x 4 + 1 x 2.5 terminals Flexible conductor mm 2 1 x 0.75 2 x 4 2 x 2.5 without cable end Flexible conductor with cable end mm 2 1 x 0.34 1 x 1.5 + 1 x 2.5 1 x 1.5 + 1 x 2.5 Tightening torque Terminal referencing Solder pins for printed circuit board Rated insulation voltage (Ui) of screw-clamp terminals only Philips head n 2 and Ø6 Conforming to standards EN 50005 and EN 50012 Conforming to IEC 60947 V 690 Conforming to VDE 0110 gr C V 750 Conforming to BS 5424, V 690 NF C 20-040 Conforming to CSA 22-2 n 14, UL 508 V 600 Rated impulse withstand voltage (Uimp) kv 8 With locating device between power and control circuits pins lenght 5 mm Recommended minimum width and thickness layer for power printed circuit board track : 4 mm x 35 microns N.m 0.8 Up to 5 contacts, depending on model Protective treatment Conforming to IEC 60068 "TC" (Klimafest, Climateproof) (DIN 50016) Degree of protection Conforming to VDE 0106 Protection against direct finger contact Ambient air temperature around the device Storage C -50 +80 Operation C -25 +50 Maximum operating altitude Without derating m 2000 Vibration resistance 5... 300 Hz Contactor open Contactor closed 2 gn 4 gn Flame resistance Conforming to UL 94 Self-extinguishing materials V1 Conforming to NF F 16-101 Conforming to requirement 2 and 16-102 Shock resistance (1/2 sine wave, 11 ms) Contactor open On X axis: 6 gn On Y and Z axes: 10 gn Contactor closed On X axis: 10 gn On Y and Z axes: 15 gn Safe separation of circuits Conforming to VDE 0106 and IEC 60536 SELV (Safety Extra Low Voltage), up to 400 V References: page 10 16 Dimensions, schemes: page 20

Characteristics - TeSys K TeSys K S335 series - Contactors for Electrodomestic applications Pole characteristics Type LCp K06 K09 K12 K16 Conventional thermal current (Ith) For ambient temperature y 50 C A 20 Rated operational frequency Hz 50/60 Frequency limits of the operational current Hz Up to 400 Rated operational voltage (Ue) V 690 Rated making capacity I rms conforming to NF C 63 110 and IEC 60947 A 110 110 144 160 Rated breaking capacity I rms conforming to NF C 63 110 and IEC 60947 220/230 V A 110 110 380/400 V A 110 110 415 V A 110 110 440 V A 110 110 110 110 500 V A 80 80 80 80 660/690 V A 70 70 70 70 Permissible short time rating In free air for a time t from cold state (q y 50 C) 1 s A 90 90 115 115 5 s A 85 85 105 105 10 s A 80 80 100 100 30 s A 60 60 75 75 1 min A 45 45 55 55 3 min A 40 40 50 50 u 15 min A 20 20 25 25 Short-circuit protection gg fuse U y 440 V A 25 (am fuse, see page 22009/2) Average impedance per pole At Ith and 50 Hz mw 3 Use in category AC-1 resistive circuits, heating, lighting (Ue y 440 V) Maximum rated operational current for a temperature y 50 C Maximum rated operational current for a temperature y 70 C Rated operational current limits in relation to the on-load factor and operating frequency A 20 A 16 for Ue only On-load factor 90 % 60 % 30 % A 300 operating cycles/hour 13 15 18 A 120 operating cycles/hour 15 18 19 A 30 operating cycles/hour 19 20 20 Increase in rated operational current by paralleling of poles Apply the following coefficients to the above currents; these coefficients take into account an often unbalanced distribution of current between the poles 2 poles in parallel: K = 1.60 3 poles in parallel: K = 2.25 4 poles in parallel: K = 2.80 Use in category AC-3 squirrel cage motors Operational power according to the voltage. Voltage 50 or 60 Hz 115 V single-ph. kw 0.37 0.55 220 V single-ph. kw 0.75 1.1 220/230 V 3-ph. kw 1.5 2.2 3 4 380/415 V 3-ph. kw 2.2 4 5.5 7.5 440/480 V 3-ph. kw 3 4 5.5/4 (480) 5.5/4 (480) 500/600 V 3-ph. kw 3 4 4 4 660/690 V 3-ph. kw 3 4 4 4 Maximum operating rate (in operating cycles/hour in relation to % of rated power) Op. cycles/h 600 900 1200 Power 100 % 75 % 50 % References: page 10 Dimensions, schemes: page 20 17

Characteristics - TeSys K TeSys K S335 series - Contactors for Electrodomestic applications Control circuit characteristics Rated control circuit voltage (Uc) V AC 24 or 230 Control voltage limits (y 50 C) single voltage coil Average consumption at 20 C and at Uc Operation 0.8 1.15 Uc (1) Drop-out u 0.20 Uc Inrush VA 30 Sealed VA 4.5 Heat dissipation W 1.3 Operating time at 20 C and at Uc Between coil energisation and: Between coil de-energisation and: opening of the N/C contacts ms 5 15 closing of the N/O contacts ms 10 20 opening of the N/O contacts ms 10 20 closing of the N/C contacts ms 15 25 Maximum immunity to microbreaks ms 2 Maximum operating rate In operating cycles per hour 3600 Mechanical durability at Uc In millions of operating cycles 50/60 Hz coil 10 (1) LC1K12, LC1K16... : 0.85 1.15 Uc. References: page 10 18 Dimensions, schemes: page 20

Characteristics - TeSys K TeSys K S335 series - Contactors for Electrodomestic applications Auxiliary contacts characteristics of contactors Number of auxiliary contacts On LCp K 1 Rated operational voltage (Ue) Up to V 690 Rated insulation voltage (Ui) Conforming to BS 5424 V 690 Conventional thermal current (Ith) Frequency of the operational current Minimum switching capacity Conforming to IEC 60947 V 690 Conforming to VDE 0110 group C V 750 Conforming to CSA C 22-2 n 14 V 600 For ambient temperature y 50 C A 10 Hz Up to 400 U min (DIN 19 240) V 17 I min ma 5 A 10 Short-circuit protection Conforming to IEC 60947 and VDE 0660, gg fuse Rated making capacity Conforming to I rms A 110 IEC 60947 Short-time rating Permissible for 1 s A 80 500 ms A 90 100 ms A 110 Insulation resistance MW > 10 Non-overlap distance mm 0.5 DF564971.eps Power broken in VA Operational power of contacts conforming to IEC 60947 16 000 a.c. supply, category AC-15 10 000 Electrical durability (valid for up to 3600 operating cycles/hour) on an inductive 8000 load such as the coil of an electromagnet: making current (cos j 0.7) = 10 times 6000 the power broken (cos j 0.4). 5000 4000 3000 2000 1000 800 600 500 400 300 200 100 80 60 40 2b 2c 24 48 110 220 120 Power broken in W 1 4 2a 380 500 440 690 V Operating cycles 110/ 220/ 380/ 600/ V 24 48 127 230 400 440 690 1 million operating cycles VA 48 96 240 440 800 880 1200 3 million operating cycles VA 17 34 86 158 288 317 500 10 million operating cycles VA 7 14 36 66 120 132 200 Occasional making capacity VA 1000 2050 5000 10000 14000 13000 9000 d.c. supply, category DC-13 Electrical durability (valid for up to 1200 operating cycles/hour) on an inductive load such as the coil of an electromagnet, without economy resistor, the time constant increasing with the load. Operating cycles V 24 48 110 220 440 600 1 million operating cycles W 120 80 60 52 51 50 3 million operating cycles W 55 38 30 28 26 25 10 million operating cycles W 15 11 9 8 7 6 Occasional making capacity W 720 600 400 300 230 200 DF564972.eps 250 200 140 100 50 20 1000 700 500 300 200 100 80 60 50 40 30 20 10 8 6 4 3 2a 2b 2c 12 24 48 110 220 440 600 V 1. Breaking limit of contacts valid for: b maximum of 50 operating cycles at 10 s intervals (power broken = making current x cos j 0.7). 2. Electrical durability of contacts for: b 1 million operating cycles (2a) b 3 million operating cycles (2b) b 10 million operating cycles (2c). 3. Breaking limit of contacts valid for: b maximum of 20 operating cycles at 10 s intervals with current passing for 0.5 s per operating cycle. 4. Thermal limit. References: page 10 Dimensions, schemes: page 20 19

Dimensions, schemes - TeSys K TeSys K S335 series - Contactors for Electrodomestic applications Contactors LC1K, LC1KT, CAK On panel 4xØ4 On mounting rail AM1 DP200 or AM1 DE200 (7 35 mm) DB419872.eps 57 58 = 50 = = 35 = 45 DF565023.eps 57 58 45 3-pole contactors 3 P + N/O 3 P + N/C 127355.eps A2 A1 T1/2 1/L1 T2/4 3/L2 T3/6 5/L3 T4/8 7/L4 A2 127356.eps A1 T1/2 1/L1 T2/4 3/L2 T3/6 5/L3 22 21/NC 4-pole contactors 4 P 2 P N/O + 2 P N/C A2 T1/2 T2/4 T3/6 T4/8 A2 2 R2 R4 4 127357.eps A1 1/L1 3/L2 5/L3 7/L4 127358.eps A1 1 R1 R3 3 CAK - 4 poles contactors for control circuits 4 N/O 3 N/O + 1 N/C 2 N/O + 2 N/C A2 14 24 34 44 A2 14 22 34 44 A2 14 22 32 44 DF533646.eps A1 13/NO 23/NO 33/NO 43/NO DF533647.eps A1 13/NO 21/NC 33/NO 43/NO DF533648.eps A1 13/NO 21/NC 31/NC 43/NO References: page 10 20 Characteristics: pages 16 to 19

Notes 21

Notes 22

Green Premium TM Endorsing eco-friendly products in the industry Schneider Electric s Green Premium ecolabel is committed to offering transparency, by disclosing extensive and reliable information related to the environmental impact of its products: Green Premium is the only label that allows you to effectively develop and promote an environmental policy whilst preserving your business efficiency. This ecolabel guarantees compliance with up-to-date environmental regulations, but it does more than this. RoHS Schneider Electric products are subject to RoHS requirements at a worldwide level, even for the many products that are not required to comply with the terms of the regulation. Compliance certificates are available for products that fulfil the criteria of this European initiative, which aims to eliminate hazardous substances. REACh Schneider Electric applies the strict REACh regulation on its products at a worldwide level, and discloses extensive information concerning the presence of SVHC (Substances of Very High Concern) in all of these products. Over 75% of Schneider Electric manufactured products have been awarded the Green Premium ecolabel Discover what we mean by green. Check your products! PEP: Product Environmental Profile Schneider Electric publishes complete set of environmental data, including carbon footprint and energy consumption data for each of the lifecycle phases on all of its products, in compliance with the ISO 14025 PEP ecopassport program. PEP is especially useful for monitoring, controlling, saving energy, and/or reducing carbon emissions. EoLI: End of Life Instructions Available at the click of a button, these instructions provide: Recyclability rates for Schneider Electric products. Guidance to mitigate personnel hazards during the dismantling of products and before recycling operations. Parts identification for recycling or for selective treatment, to mitigate environmental hazards/ incompatibility with standard recycling processes.

Schneider Electric Industries SAS 35, rue Joseph Monier CS 30323 92506 Rueil Malmaison Cedex France RCS Nanterre 954 503 439 Capital social 896 313 776 www.schneider-electric.com April, 2017 2017 - Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. Document reference: LVCATESDK335_EN This document has been printed on ecological paper. This document has been printed on recycled paper