References 4 Fuse carriers

Similar documents
3 - Protection components Motor circuit-breakers

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Modular contactors and relays

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Contactors. d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. References

Practical and completely safe

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors

Protection components

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

LR9 F OVERLOAD RELAYS

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

General data 5/37. Overview

C -5 to +55 (0.8 to 1.1Uc) Permissible o

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

AF40... AF96 3-pole contactors Technical data

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC

TeSys GS & DF Fuse protection

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors

Vistop TM isolating switches 63 to 160A

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Industrial Contactors CTX 3 3P 185A - 800A

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

TeSys contactors. Characteristics. Environment Rated insulation voltage 5/50. Contactor type LC1 D09 D18 DT20 and DT25. DT60A and DT80A.

Protection Equipment. 5/2 Introduction

TAE pole Contactors

Protection Equipment

Motor Starter Protectors

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

D509E. Manual Motor - Starters

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Essential equipment for all your requirements

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

Fuse holders and fuses

Low Voltage. EasyPact TVS. Motor starters from 6A to 630A. Catalog 2015

Meta Solution. Contactors and Overload relays

Motor Starter Protectors

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

AF series contactors (9 2650)

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Short form catalogue. Motor protection & control

AE 9... AE 40 Contactors NE... Contactor Relays

K50H004UP cam changeover switch - 4-pole A - screw mounting

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC

K30H001YP cam star-delta switch - 3-pole A - screw mounting

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Motor control The essential guide

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

1 Phase electronic contactor (SC 1)

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF series contactors (9 2650)

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Bulletin 100-D IEC Contactors

An innovative technology

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.

E 90 range of fuse disconnectors and fuseholders Uncompromising performance

ASL09..S 3-pole Contactors - Spring Terminals

Phase + Neutral, neutral on right side

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

Air-insulated switchgear UniGear type ZS1

Partnership that you can trust. LV Switchgear Motor Control Products.

10/97 N Our policy is one of continued research and development. We therefore reserve the right

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

SIRIUS 3RU2 Thermal Overload Relays

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

8WH2 Spring-Loaded Terminals

Ktec Contactors and thermal overloads

Phase + Neutral, neutral on left side

Stars or starlets? Competitor overview switching devices. Only for internal use. sirius IN COMPARISON

TeSys D Overload Relays

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Enclosed Starters. Contents. Motor nominal powers and current... 20/2. Panorama... 20/3. Starting of three-phase asynchronous motors...

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Thermal overload relays Type TA Class 10

fuses fuse holders CYLINDRICAL

3NP1 Fuse Switch Disconnectors up to 630 A

TeSys D Green. Catalogue 2017 AC/DC compatible coil contactors. schneider-electric.com

Capacitor Switching Contactors Type K3...-A, K3...-K

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

8WH2 Spring-Loaded Terminals

Transcription:

References components 000_ -pole basic blocks Rating Cartridge fuse size umber of early break contacts () Single-phase protection device () Reference () Connection by spring terminals A 0 x 8 () Without LS D 0.70 Connection by screw clamp terminals or connectors A 0 x 8 () Without LS D 0.00 0 A x Without GK EK 0.0 LS D With GK EV 0.70 Without GK ES 0.70 000_ With GK EW 0.0 A x 8 Without GK FK 0.80 With GK FV 0.900 Without GK FS 0.900 With GK FW 0.90 888 LS D -pole basic blocks Connection by screw clamp terminals or connectors A 0 x 8 () Without LS D + LA8 D () 0 A x Without GK EM 0.70 0.00 With GK EY 0.00 Without GK ET 0.0 With GK EX 0.0 GK FK A x 8 Without GK FM.090 With GK FY.0 000_ 000_ for the orth American market and 0 A basic blocks: please consult your Regional Sales Office. Without GK FT.0 With GK FX.0 LS D + LA8 D () With or early break contacts to be inserted in the contactor control circuit. () with single-phase protection device must be fitted with striker fuses. () LS D: clips directly onto a mm rail or screw fixing. GK: clips directly onto a mm rail or Telequick mounting plate. () Addition of add-on contact block, see page 07/. () Can be mounted on left-hand or right-hand side of the basic block. Selection : page 0/ Characteristics : page 0/ Dimensions : page 08/ Schemes : page 08/ 07-E_Ver.0.fm/

References components Operators and accessories Add-on contact blocks Description For use on Mounting Maximum number Type of contacts Sold in lots of Instantaneous LS D Front /O + /C 0 GV AE 0.00 auxiliary contacts (early break contacts) /O + /O 0 GV AE0 0.00 LS D Front /O + /C 0 GV AE 0.00 /O + /O 0 GV AE0 0.00 8088 Operators For fuse carrier For Reference Rating umber of poles mounting on Side handles A or Right-hand side GK AP07 0.00 Left-hand side GK AP08 0.00 Front handles () - 0 - A Fitted as standard GK FK + GK AP07 External handles A or Right-hand side LS D00 () 0.00 Left-hand side LS D00 0.00 0 A or Right-hand side GK AP0 0.80 Left-hand side GK AP0 0.80 A or Right-hand side GK AP07 0.00 Left-hand side GK AP08 0.00 Padlocking devices () For fuse carrier Reference Rating umber of poles Single-phase protection device A or Without integral 0 A Without GK AV07 0.00 With GK AV08 0.0 Without GK AV08 0.0 With GK AV09 0.070 Links Tubular links For fuse carrier Sold in Rating umber of poles lots of A or 0 DK CB9 () 0.007 0 A or 0 DK EB9 () 0.0 A or 0 DK FA9 () 0.00 () Fitted as standard on, 0 and A fuse carriers type GK. () Reference LS D00 replaces DK FB00. () For the A rating, use side handles GK AP07 or GK AP08. () For use on a neutral circuit, the tubular link can be interlocked with special device LA8 D90 (sold in lots of 0). () 0 and A fuse carriers type GK are fitted with an interlocked neutral tubular link as standard. Selection : page 0/ Characteristics : page 0/ Dimensions : page 08/ Schemes : page 08/ 07-E_Ver.0.fm/

07-E_Ver.0.fm/

References components Accessories Accessories for LS D (screw clamp terminals) Description Sold in lots of Plate for mounting LS D and contactor LC D09...D8 with front faces aligned Combination blocks Between LS D and contactor LC K or LP K Between LS D and contactor LC D09...D8 Between LS D mounted on LAD and contactor LC D09...D8 Description Pitch mm Sets of -pole A busbars LAD 0.00 0 GV AF0 0.00 0 GV AF 0.0 0 GV AF 0.0 Reference tap-offs GV G 0.0 GV G 0.08 7 GV G7 0.0 tap-offs GV G 0.08 GV G 0.00 tap-offs GV G 0.077 GV G 0.08 7 GV G7 0.09 tap-offs GV G 0.00 Description Sold in lots of Protective end cover For unused busbar outlets GV G0 0.00 Terminal blocks Connection from the top For supply to one or more GV G busbar sets GV G09 0.00 Cover for terminal block For mounting in modular panels 0 LA9 E07 0.00 Padlocking device For use with up to padlocks (not supplied) Ø mm shank max GV V0 0.09 Accessories for LS D (spring terminals) Description Reference Plate for mounting LS D and contactor LC D09...D8 with front faces aligned LAD 0.00 Description Extension by umber of starters Reference Power splitter box, A LAD p LAD 0.0 LAD 0.80 LAD 0.0 Description Kit contents Reference Assembly and power connection kit for LS D and LC D09...D LAD plate for mounting LS D LAD power connection modules - between LS D and power splitter box - between LS D and contactor Description Maximum capacity Upstream mm Power supply to or terminal block power splitter boxes Sold in lots of LAD 0.078 LAD B 0. Downstream mm Connection of motor cables LAD 0.00 terminal block Cable end reducer For connection of conductors from to. mm 0 LAD 99 07-E_Ver.0.fm/

Selection components Operation: safety The fuse carrier performs two basic functions: b it isolates the downstream circuit by means of a visible break and wide opening contacts, b it holds the cartridge fuses designed to protect the installation against shortcircuits. The type of cartridge fuse needed to protect the circuit must be determined before selecting the fuse carrier. Cartridge fuse selection (type, rating, size) Type Solution Solution b Motor protection. b Transformer protection. b am type fuses. These fuses are designed to withstand high current peaks of a very short duration. They must be combined with a thermal overload relay coupled with a contactor. b Lighting circuit protection. b Supply line protection. b Furnace protection. b gg type fuses, which are more widely used but whose limiting capacity is weaker than that of am type fuses. Rating gg fuses am fuses Size See standard F C -00. Table A paragraph -- and table C paragraph -. Motors x 0 V Motors x 00 V Cartridge fuses type am Fuse carrier P in P in Size Rating kw A kw A A 9 8. 0 x 8 LS D 9 x 0 GK EK 7 7 7 x 8 80 GK FK 0 0 0 x 8 GK FK Use the fuse characteristics table opposite to select the correct fuse size according to: b the nominal current of the circuit to be protected, b the operational voltage. Fuse carrier selection Solution Solution Isolation of a circuit for safety reasons only. The fuse carrier may be fitted with links. The maximum permissible current is indicated in the pole characteristics table opposite. Isolation of a circuit and its protection against short-circuits. Select a fuse carrier according to: b the type of cartridge fuse required, b the maximum permissible current in the fuse carrier poles (see pole characteristics table opposite). If the operational current is greater than the maximum permissible current in the poles of the fuse carrier corresponding to the cartridge fuse size selected, select the fuse carrier the next size up. The safety provided by using a fuse carrier can be increased by adding a padlocking device with up to three padlocks. Recommendations for use The fuse carrier conforms to utilisation category AC-A/A of standard IEC 097-. It is therefore recommended that the fuse carrier early break auxiliary contacts always be inserted in the coil circuit of the contactor with which it is in series. If the fuse carrier is not associated with a contactor, it is essential to ensure that it will be operated off-load. Characteristics : page 0/ References : pages 07/ and 07/ Dimensions : page 08/ Schemes : page 08/ 0-E_Ver7.0.fm/

Characteristics components Fuse carrier type LS D LS D GK Ep GK Fp Environment Conforming to standards F E 097- p p p IEC 097- p p p Product certifications BV, UR Protective treatment TH TC TC Ambient air temperature for operation with links without derating Maximum tilt in relation to normal vertical mounting plane Pole characteristics C - 0 + 70-0 + 70-0 + 70 ± ± ± Fuse size 0 x 8 0 x 8 x x 8 Rated operational voltage V 90 90 90 90 with links. a.c. supply Maximum continuous current at ambient temperature y 0 C () (Min. cable Ø/Ie) With tubular links mm /A / or / / or./ 0/0 or /0 / or /00 or./ With am fuses mm /A / or / / or./0 0/0 or / / or /00 or./0 With gg fuses mm /A / or./0 or././0 or./ 0/0 or / /00 or /80 Early break contact characteristics Rated operational voltage V a 0. c 0 a 0. c 0 a 00. c 0 a 00. c 0 Conventional thermal current A.. Cartridge fuse characteristics Fuse size 0 x 8 0 x 8 x x 8 Type am a 00 V A () 0 a 00 V A 0 0 0 80 a 0 V A 0 Type gg a 00 V A () 0 00 a 00 V A 0 80 a 0 V A 0 Maximum power dissipated by fuse W 8. 8 Cabling Connection by screw clamp terminals or connectors umber and c.s.a. of conductors Min. Max. Min. Max. Min. Max. Min. Max. Solid cable mm x x x. x x x 70 Flexible cable without cable end mm x. x x. x x x 0 Flexible cable with cable end mm x x x. x x x Connection Screw clamp Connector Connector terminals Tightening torque m.7 Connection by spring terminals umber and c.s.a. of conductors Min. Max. Min. Max. Min. Max. Min. Max. Solid cable mm x () x Flexible cable without cable end mm x. x () () For use in an installation with ambient temperature > C, apply a derating coefficient equivalent to 0 ambient temperature ------------------------------------------------------------------------ 80 () These values are for fuse carriers mounted side by side with a gap of 0 mm between them or mounted with sets of busbars GV p. If mounted side by side without a gap, use the following fuse sizes: am fuse: A and gg fuse: 0 A. () For cross-sections to. mm, the use of an LA9 D99 cable end reducer is recommended. Selection : page 0/ References : pages 07/ and 07/ Dimensions : page 08/ Schemes : page 08/ 0-E_Ver7.0.fm/

Dimensions, mounting components LS-D LS-D + LA8-D Mounting on rail AM-DP00 Mounting on panel Mounting on rail AM-DP00 Mounting of th pole On left-hand side On right-hand side 89 8 87 89 87,, 8, 0,8,, x Ø 0 7 7, 7, GK-EK, EM, ES, ET, EV, EW, EX, EY Mounting on rail AM-DP00 Mounting on pre-slotted plate AM-P GK-E + GK-AV (padlocking device) 8 9, 9 0, 0, 8 a 7, 7, a 7, 8,, a : with single-phase protection device. a : without single-phase protection device. External operator GK-AP0 right-hand, GK-AP0 left-hand Panel cut-out 70 GK- a a P P P P EK 88 EM ES 97 ET EV 0 EW External operator, right-hand or left-hand side f EX GK-EK, EM, ES, ET 9 EY GK-EV, EW, EX, EY 9 GK-Fp + GK-AP07 (internal right-hand control) Mounting on rail AM-DE or ED 70 0 Mounting on pre-slotted plate AM-PA a AF-EA f 8 0 7 0 00/0 a a GK-Fp P P P P 70 0 9 a a 8 7, a () 8 a Internal or external control GK-AP07 right-hand, GK-AP08 left-hand () Padlocking device (up to padlocks) Panel cut-out (for external control) GK- a a P P P P FK FM FS FT 7 FV FW External operator, right-hand or left-hand side f FX 8 GK-FK, FM, FS, FT FY 7 GK-FV, FW, FX, FY = = = = 8, = =, 0 f 8 0 Selection: page 0/ Characteristics: page 0/ References: pages 07/ and 07/ Schemes: page 08/ 08-E_Ver.0.fm/ Schneider Electric

Schemes components without single-phase protection device -pole LS-D, D LS-D, D + GV-AEp LS-D, D + GV-AE0p GK-EK -pole GK-ES GK-FK GK-FS LS-D + LA8-D -pole + eutral GK-EM GK-ET GK-FM GK-FT with single-phase protection device -pole GK-EV GK-EW GK-FV GK-FW -pole + eutral GK-EY GK-EX GK-FY GK-FX 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 8 7 Selection: page 0/ Characteristics: page 0/ References: pages 07/ and 07/ Dimensions: page 08/ Schneider Electric 08-E_Ver.0.fm/